Document Z44gYwKDYeDKbenvnbKQVMb7O

PLAINTIFF'S EXHIBIT ASA-678 The Ashestosis Research Council For Handling Asbestos Products Used in Thermal Insulation' ASARCO ELP 0002986 The Asbcstosis Research Council Present factory regulations recognise asbcstosis as an industrial disease which could arisefrom the inhalation of asbestos dust, and stipulate rules for the pro tection of work people engaged in the manufacture of certain types of asbestos products. No regulations have yet been introduced relating to the handling of asbestos productsfor thermal insulation, although it is accepted that to eliminate the risk of asbcstosis all practical steps should be taken to minimise the inhal ation of asbestos dust. For this reason The Asbcstosis Research Council set up a committee of doctors and engineers to considct whet steps should be taken for the protection of workers in this branch ofthe asbestos industry. As a result of its work, the Committee has recommended 'that the industry should adopt thefollowing code ofpractice. Recommended Code of Practice Where asbestos products arc used the following procedures should be adopted: (1) Wherever possible preformed material rather than site mixed material shjuld be used. (2) Working with loose lagging material should be done in the wet state wherever practicable, rather than in the dry. Methods of transporting pre mixed wet compounds from segregated mixing areas should be used wherever possible. (3) When dry mixing is being done respirators should be worn unless a machine with a properly designed ventilation system is available. Portable exhaust ventilation systems arc already in use in certain shipyards. Tin's procedure should be extended. (4) Where the cutting of material containing asbestos takes place it should be done whenever possible in a segregated area where there is a free circulation of air. If continuous cutting of insulation materials is being carried out a . . portable hopper should be used for die collection offall-out waste. Machines arc available for ensuring dust exhaust at a cutting bench. ` (5) In the ease ofspraying asbestos, the practice to be adopted will depend on the type of equipment used. The various types arc defined in the Appendix. In all eases the asbestos fibre must not be removed from the dust-proofsacks t . 1 ASARCO ELP 0002987 ia which it is supplied until it is fed into die machines in die prescribed maimer. Giro should be exercised in handling the sacks in order not to damage them.' (a) The use of effective pre-treatment reduces die concentration of dust to the level obtainable by an efficient exhaust ventilation system. Where pre-treated fibre is used, spraying with any type ofmachine may proceed without limitations save that the operators must, during spraying operadons and for a short period thereafter, wear approved masks. (b) Self-ventilating machines without pre-treatment equipment may be used in spaces where die volume ofair per spray gun in action is not less dian 25,000 cu ft provided that operators use approved masks during spraying and for 30 minutes thereafter.. Other tradesmen not supplied with masks may not enter die room until 30 minutes after spraying has ceased. Normal ventilation by open windows is permitted. Where rooms arc below 25,000 cu ft volume per gun mechanical ventila tion must be provided to give two air changes per hour, and operators must wear approved masks during spraying and for at least 30 minutes thereafter. Other trades must not enter whilst spraying is in progress and for one hour thereafter. (c) Non-vcndlatcd machines without pre-treatment equipment should only be used in spaces exceeding 50,000 cu ft volume pf: gun; operators and odicr workers approaching widiin 56 ft-of the machine and/or the gun must wear approved masks during spraying and for 15 minutes after wards. Normal ventilation by open windows is permitted." .(6) Stripping of Materials Containing Asbestos The area' in which stripping takes place should be classified as a segregated location and operatives engaged on such work should wear approved type respirators. (a) Where site location permits, protective sheeting (dust shccts/polythcnc shrouding etc.) should be used to localise or isolate the working area. (b) Wherever conditions permit i.c. on Inside work -- power stations, .ships' engine rooms, piping and ducting inside buildings, portable industrial vacuum cleaners should be used during stripping operations and for cleaning-up purposes in die working area. (c) Where the lagging is receptive to such treatment, wetting prior to and during the removal ofdie material should be carried out. (7) Where operations covering mixing, cutting and spraying are carried out and wherever dust can be inhaled, approved respirators should be used and maintained as set out below. '2 J ASARCO ELP 0002988 Use and Care of Respirators i Respirators should be worn by all employees at all times when: _ (r) Spraying asbestos and feeding hoppers on sprayed asbestos work. Respirators . should be worn by both operator and attendant during the full period that work is being carried out and by any employee remaining in the dusty atmosphere for a limited period after, spraying operations have terminated. (2) Carrying out die following operations which, wherever possible, should he carried out in open spaces where there is a free circulation ofair: (a) The mixing of any material containing asbestos. {This operation must be carried out in segregated areas if possible.) (b)Tiic mixing of compositions and self-setting cements which, have an asbestos content. (c) The cleaning and emptying of sacks or other containers which contain asbestos or an admixture of asbestos. Where the above operarfons arc being carried out in confined spaces adequate arrangements must be made for ventilation. (3) Carrying out die following operations: .. . (a) The cutting ofall insulation materials containing asbestos or xi admixture of asbestos by hand in confined spaces. (b) The cutting of materials containing asbestos or an admixture of asbestos by portable or other power-driven saws or similar tools. (c) The breaking, down for removal of lagging containing asbestos or an admixture ofasbestos. The approved respirator should, be carefully maintained and adequate servicing arrxigcmcnts should he made to ensure that this is done and that employees are not without respirators during maintenance. Medical Supervision of Workers (1) All employees should be examined clinically and radiologically before ' employment or as soon as possible afterwards, certainly within three months, to avoid the employment of men who may be particularly susceptible to the ! hazard. ` (2) Periodic examinations should be made thereafter, annually ifpossible. (3) Notes on the Medical Examination of Workers in the Asbestos Industry arc available as a guide to doctors concerned. . 3 ASARCO ELP 0002989 (4) New employees should be advised of the precautions necessary in die industry. (5) A system of recording th? employment history of workers ent me Thermal Insulation Industry or who have been employed in the"insutarioa contracting industry would be beneficial. 4 ASARCO ELP 0002990 Appendix Definitions . (a) Pre-treatment Equipment The pre-treatment equipment and media should be capable ofrestricting die amount ofdust in the atmosphere during spraying to a level approximating to that achieved in a modem asbestos textile plant. Pre-treatmentshould be carried out in a segregated area, the operator wearing an approved mask. The equipment may consist of a closed rotating drum which throws a measured quantity of fibre across a finely atomised water spray which is projected along the axis of the drum. The action, which is improved by the addition of a wetting agent to the water, takes place over a period of time sufficient to produce a uniform dampening of the asbestos fibres to which the finer" particles of asbestos adhere, even when passed through the spraymachine and ejected from the gun. Spraying is carried .out immediately after the dampening cycle is completed. (b) Self-ventilating Machine One in which the fan providing the air stream in which the fibre'is conveyed through the hose to the gun draws its air supply via a path from the fibre hopper charging aperture, the charging of the hopper being carried' out only whilst the spray machine fan is operating. (c) Non-vcutilatcd Machine ^ .. A machine in which the air stream for conveying the fibre is induced from a source outside the machine and which provides no air movement away from the operator's face when the machine is being charged with fibre. * December 1966 The Asbestosis Research Council - Secretary Dr S. Holmes P.O. Box No 40 Rochdale, Lancashire Telephone: Rochdale 47422 - " ] . ' 5 ASARCO ELP 0002991