Document YyMYkqXJMkReBY5zokLbB3ey
I ft
< <
n ,o
o o i3 -4
CD
REGULATED AREAS #1 #5
(conoco)
Interoffice Communication
tq J. A. De Bernard!
From p. L. Fetzer
Date
subject
December 18, 1979 Deregulation of Area I - East End of Block I
Shown below are the monthly averages of the daily average of the fixed
point monitors located in Regulated Area No. I. The data also shows the average value excluding sample point No.
All Sample Points
Excludinq Sample Point #1
March
April May
June (5-days) July August
September October November
1 .20 0.96 1.05 0.95
--
--
--
0.57 0.16
1.03 0.83 0.95 0.93
--
--
--
0.50 0.14
The data for the period March through June represents the values prior to correcting problems existing inthe calibration procedures. The data for October and November represents the exposure data after the corrected standardization and calibration procedures were initiated.
The earlier data showed the VCM exposure to be very near 1.0 ppm within the regulated area. Thirty-three percent of the daily average values exceeded 1.0 ppm. The most current average results are much lower, at or below 0.5 ppm VCM, while twelve percent of the individual daily average values exceeded 1.0 ppm.
This reduction in the current average exposure values indicates the likelihood of the earlier calibration procedure produced data that was biased on the high side as would be expected based on the problem found during the calibration of the instrumentation. The sample was analyzed at a higher loop pressure than the standard thus causing a larger sample to be analyzed for each sample point.
The personnel dosimeter VCM exposure data for the outside operators working within Regulated Area No. I are shown below.
VVC 000007729
J. A. De Bernard! December 18, 1979
Page 2
ppm VCM
0-0.5 0.5-1.0 1.0-2.0 2.0-3.0 Over 5.0
1979 Personnel Exposure Data
Normal Duties
Turnaround Duties
Block I
Block II
Block I
Block II
15 18 2 2 00
1 04 0 01 0 04
7 4
3 0 0
This data shows the 8-hour exposure values are in agreement with the average exposure value with Regulated Area No. I. One individual of the forty-six tested throughout the year while performing normal duties exceeded 1 ppm. This amounts to a 2.0% overexposure rate.
In summary, the average values for the fixed point monitoring system analyses show the VCM exposure to be at or below 0.5 ppm. This exposure also agrees with the personnel dosimeter data for those employees working this area of the plant. It is recommended that the Regulated Area No. I be deregulated.
PLF:1 ad
CC: GLF, WVH, HDG
WC 000007730
M>. s 4-_.^<L_y ^.
'hz=XA^(^,
(CA'As^--- . _ cAjLs\y-As@-y\jL~^
/ ` /'
^sA~Z^< CTYLS cAj^ _
Z*i~G^
_.^y /<s_
^-^.4^0 y7^-C<^r-v
ItJCs - ^p^AA
..
C<fA-*--'
l/#n
T-*4 ^
...j2-&icyis: 7"-.<S"Z .
V-^T" ^ ^^t^-T-Tv-' )f?/7 /
?--& z.
VVC 000007735
t-o /'JtQ
7~-o_ o?r$ /
T~-*o T-s/ Zzl:Z
#,2$
*/./*/ 3^<? ^2"
J^r^L*j
dfo-Aj~-ocL
~r-s-3
yyy^ yuLy^y!*/'
y/ s&'t-t-C'y yu?>- _
* ' _.-.
yL^fay&U-'
^-<^^zy-z ?^y<^
y^^tyl /V ^ ..yy-*^ #-- ^ ^