Document Yrq6Q574aB5RjYNawLwqR2KEO
RCRA Compliance Branch INSPECTION REPORT
Inspection Date(s):
6/12/2024
Inspection Announced: No
Facility or Site Name: Facility/Site Physical Location:
(city, state, zip code) Mailing address (if different from above):
(city, state, zip code) Facility/Site Contact:
Ducommun Aero Structures, Inc. 171 Stacey Road Coxsackie, NY 12051 see above
Mary McCoy mmccoy@ducommun.com (203) 300-7303
EHS Manager
RCRA ID Number:
NYR000219550
Facility/Site Personnel Participating in Inspection:
Mary McCoy
EHS Manager
Robert Hasenkopf
Center Director
Sunder Shelhamer
Maintenance Lead
Millage Howe
Value Stream Manager
mmccoy@ducommun.com rhasenkopf@ducommun.com sshelhamer@ducommun.com mhowe@dummon.com
Inspector(s):
Vince Damiano (ERG [EPA Contractor])
Vincent Damiano
Digitally signed by Vincent Damiano Date: 2024.08.15 14:33:08 -04'00'
8/15/2024
EPA Supervisor Derval Thomas (EPA Region 2)
DERVAL THOMAS
Digitally signed by DERVAL THOMAS Date: 2024.08.19 13:59:27 -04'00'
Inspection Report Authors: Vince Damiano
RCRA Compliance Branch INSPECTION REPORT
SECTION I - INTRODUCTION
Purpose of the Inspection Objective
EPA Region 2 identified Ducommun Aero Structures, Inc. ("Ducommun") as a target for a compliance evaluation inspection (CEI). The purpose of the inspection was to determine the facility's compliance with the Resource Conservation and Recovery Act (RCRA). The inspection was conducted by Vince Damiano (ERG).
Opening Conference
The inspector arrived at Ducommun at approximately 9:00 am on June 12th, 2024, for an unannounced RCRA inspection. Inspector Damiano first met with Robert Hasenkopf (Director), Sunder Shelhamer (Maintenance Lead), and Millage Howe (Value Stream Manager). Vince Damiano presented his RCRA inspector credentials to Mr. Hasenkopf, Mr. Shelhamer, and Mr. Howe and informed them that this was an EPA RCRA CEI that covered all RCRA regulations. Inspector Damiano inquired about any permitting requirements for the use of equipment that is not intrinsically safe in the process area and explained Ducommun's right to claim confidential business information (CBI). Ducommun indicated that no information included in this report was claimed as CBI. The inspection report and attachments present the results of the CEI.
Facility/Site Description
Ducommun produces structural and electronic components and subassemblies for commercial and military aircrafts. The facility receives sheet metal in bulk and performs "structural assemblies," primarily creating aircraft parts using techniques such as sheet metal cutting ("waterjet"), bending, cold-forming ("drop hammer"), stamping (punch and break presses), welding, assembling, coating (Everlube spray booths), etching and other operations. Ducommun began operations at this site in 2016 and employs approximately 230 employees. The facility consists of a 150,000 ft2 building sitting on a 20-acre plot.
Facility representatives said the sheet metal is first brought to the Blank Cell Area where it undergoes shearing and waterjet cutting for processing. After the sheet metal is cut, it is brought to the main process area. In this area, parts molds are stored in the Die Storage Area and then pre-heated in ovens. The heated dies are used in hydraulic and electric hot die presses in the Hot Form Press Area. Sheet metal is then bent using break form press machines in the Press Break Area and the Hot Break Form Area. Parts are cleaned in one of
2
RCRA Compliance Branch INSPECTION REPORT
five value streams using alkaline cleaners. Coating operations occur in the Everlube spray booths and then the final parts are painted in the paint booths.
The site is currently operating as a Large Quantity Generator (LQG) of hazardous waste. Most of the hazardous waste generated is nitric/hydrofluoric acid mix used to clean parts in their value streams and Alodine 600/1200 used as a protective coating. The nitric/hydrofluoric acid mix and Alodine coating both carry D002 and D007 hazardous waste codes. The site also generates hazardous waste from their painting and coating activities which carries D007, D011, and F003 hazardous waste codes. The hazardous waste is picked up by Veolia ES Technical Solutions (NJD080631369) and transferred to Freehold Cartage Inc. (NJD054126164). Freehold Cartage will then transport the waste to one of two designated disposal facilities - Veolia ES Technical Solutions (NJD980536593) in Flanders NJ or Stablex Canada (NYD98075615) in Blainville, QC, Canada. The site also generates Oakite 160 Solution which is a caustic aluminum coating for etching processes and carries a D002 hazardous waste code. Paint debris, used oil, spent acetone, and universal waste are also generated at the facility. Ducommun operates under a New York State Facility Air Permit (Registration ID: 4-1928-00219/00003) issued on October 19, 2017.
SECTION II - OBSERVATIONS
The inspector arrived at the Ducommun facility in Coxsackie on the morning of June 12th, 2024. Following the opening conference and a discussion of the facility processes, the inspection team conducted a walkthrough starting at approximately 9:30 am. The inspector observed the Blank Cell area, the value streams, paint booths, Everlube spray booths, central accumulation area (CAA), and several satellite accumulation areas (SAAs). The inspector ended the walkthrough at 11:00 am.
All photographs taken during the walkthrough are provided in Attachment 1. The photograph numbers in this report correspond to the numbers in Attachment 1. Further details regarding each of the areas observed during the walkthrough are discussed in the sections below.
Blank Cell Area
The inspection team observed the Blank Cell Area where bulk raw materials are stored and the sheet metal is cut using water and garnet. The wastewater from the cutting process is collected in sumps and sent to a series of underground settling tanks where spent garnet and water are collected. After the water is separated from the garnet, it is sent to a POTW to be treated and released. The inspector inquired about Ducommun having a permit or letter for approval to discharge wastewater to the Village of Coxsackie POTW, and Ms. McCoy provided correspondence with the POTW stating the facility is not a categorical
3
RCRA Compliance Branch INSPECTION REPORT pretreatment facility and a permit is not required (see Attachment 2). The inspector requested waste determinations for the wastewater being discharged, the garnet/water mix in the settling tanks, and the spent garnet following the inspection. The analytical results were provided by Ms. McCoy showing all three are non-hazardous (see Attachments 3, 4, and 5). The inspection team observed a 55-gallon drum and a 5-gallon container collecting used oil from the water-jet cutter which was not labeled as shown in Photograph 1 and 3. Ducommun personnel said the used oil is collected in the 5-gallon container and transferred to the 55-gallon drum once full.
View of unlabeled 55-gallon drum of used oil. {Photograph 1, Attachment 1}
4
RCRA Compliance Branch INSPECTION REPORT
View of unlabeled 5-gallon container of used oil. {Photograph 3, Attachment 1}
Value Streams and Everlube Spray Booth
The inspector observed two of the five value streams as each value stream is set up the same way. Each value stream processes parts based on size, with distinct value streams dedicated to small, medium, and large parts. Despite the size differences, all value streams serve the same purpose: bending, etching, heating, break forming, and cleaning parts before they are assembled. The parts are cleaned using a nitric/hydrofluoric acid mix. This mixture is kept circulating in open tanks and changed about once every two weeks. When changed, the used acid mix is transferred into a tote which is then stored in the CAA as hazardous waste. The inspection team also observed an Everlube spray booth where parts are coated in a protective coating to prevent damage when heated. A 35-gallon drum of acetone rags which was properly labeled as hazardous waste and closed was also observed in this area. No areas of concern were found at the value streams and Everlube spray booth.
Paint Booth
The inspector observed the VS3 paint booth where parts are painted before assembly. Two 55-gallon drums were observed in the paint booth's SAAs, one containing flammable enamel paint slow drain and the other flammable enamel paint quick drain (see Photographs 6 through 8, Attachment 1). Each 55-gallon drum was managed as a separate
5
RCRA Compliance Branch INSPECTION REPORT SAA. An acetone rag container was also present in the paint booth which was properly labeled as hazardous waste and closed. The inspection team found a red metal cabinet labeled as expired paint. The storage cabinet contained approximately 30 1-gallon expired paint cans as shown in Photograph 9. The facility stated in a follow-up email after the inspection that the expired paint is not considered waste because the facility uses it for training and troubleshooting purposes (see Attachment 6).
View of metal storage cabinet containing expired paint in VS3 Paint Booth. {Photograph 9, Attachment 1}
Waste Storage Areas
The inspector observed the CAA for the site, where totes of nitric/hydrofluoric acid mix from the value streams, drums of spilled acid debris, totes of paint waste, and totes of acetone rags are stored before being picked up for disposal. The CAA is a storage shed separated into three different bays. Inside the first bay was a half full tote of nitric /hydrofluoric acid mix labeled as hazardous waste with an accumulation start date of June 5, 2024. There was also a 35-gallon drum of acidic spill debris properly labeled with the same accumulation start date of June 5, 2024. Behind the tote of acid waste, the inspector observed a 5-gallon carboy labeled as hazardous waste containing hydrofluoric acid and chromic acid with an accumulation start date of September 11, 2023, as shown in Photograph 12. When asked if they knew it was past the 90-day storage period, the facility personnel stated the container was from a spill and they were unaware that the container was being stored in the CAA.
6
RCRA Compliance Branch INSPECTION REPORT
View of 5-gallon carboy containing hazardous corrosive waste stored past the 90-day storage period inside bay 1 of CAA. {Photograph 12, Attachment 1}
The inspector observed the second bay in the CAA which contained four lined cardboard totes labeled as hazardous waste. One of the totes contained acetone debris and did not have an accumulation start date or indication of hazards of its contents on the label. The tote contained a DOT placard indicating a miscellaneous hazard was contained inside the tote, but the facility ships acetone debris out with waste code D001 (flammable). Therefore, the DOT placard did not constitute an appropriate indication of hazards of the container's contents. The tote was also open at the time of the inspection with no sign of waste being added into the container(see Photographs 13-14, Attachment 1).
7
RCRA Compliance Branch INSPECTION REPORT
View of acetone debris tote stored with top opened inside the CAA. {Photograph 14, Attachment 1}
Another tote contained paint debris and did not have an accumulation start date or indication of the hazards of its contents on the label. The tote contained a DOT placard indicating a miscellaneous hazard was contained inside the tote, but the facility ships paint debris out with waste codes D001 (flammable) and D007 (chromium). Therefore, the DOT placard did not constitute an appropriate indication of hazards of the container's contents. The tote was also open at the time of the inspection with no sign of waste being added into the container (see Photograph 18, Attachment 1).
8
RCRA Compliance Branch INSPECTION REPORT
View of paint debris tote stored with top opened with no accumulation start date inside the CAA
{Photograph 18, Attachment 1} The remaining two totes were labeled as Adhesive/Sealant Debris; one of which did not have an accumulation start date, while the other had an accumulation start date of April 30, 2024. Neither of the totes contained an indication of hazards of their contents on the waste label (see Photographs 15, 16, and 19, Attachment 1). The facility stated in a followup email that these two totes were pending analysis and provided the inspector with analytical results on the Adhesive/Sealant debris proving that the waste was nonhazardous following the inspection (see Attachments 6 and 10). The third bay of the CAA was used to store drums of product and materials. The inspector also observed a working communication device, fire extinguisher, and spill kit in front of the CAA (see Photographs 23 and 24, Attachment 1). Ducommun provided a follow-up email responding to initial areas of concern found during the inspection. In this email the facility included photographs of the acetone debris tote and paint debris tote properly closed and labeled with an accumulation start date. They also included an image of a manifest for the hazardous carboy found stored past the accumulation time limit, stating it was shipped offsite on 6/18/2024. These photographs can be found in Attachment 7.
9
RCRA Compliance Branch INSPECTION REPORT
Universal Waste and Used Oil Storage
The inspector observed the universal waste and used oil storage areas. In the used oil storage area, there was one 55-gallon drum containing used oil designated by a sign and a 55-gallon drum for oily debris also designated by a sign, however the drum storing used oil did not contain a label or marking on the container (see Photograph 20, Attachment 1). In the universal waste storage area, the inspector observed a 5-gallon container of lead acid batteries, properly labeled with an accumulation start date of November 2, 2023; and two 5-gallon containers of aerosol cans properly labeled with accumulation start dates of September 24, 2023 and March 19, 2024 (see Photograph 21 and 22, Attachment 1).
Records Review
The inspector reviewed the following compliance documents as part of the records review:
Contingency Plan: In response to a request to provide the Contingency Plan, Ducommun provided a copy of their RCRA Contingency Plan which also includes emergency response procedures. The plan is dated with a last reviewed date of February 1, 2024. The RCRA Contingency Plan is provided in Attachment 8. Additionally, the facility provided several email correspondences with local emergency departments to coordinate dates so they can visit the site and become familiar with the layout and Ducommun's emergency response plans; this includes emails indicating local emergency responders have received a copy of their contingency plan, which can be found in Attachment 9.
The Contingency Plan provides lists of key management personnel and indicates that the EHS Manager is the Plan Administrator. The plan states that if more than 2.5 gallons of hazardous material is spilled the Fire Department will be called; and that for a spill less than 2.5 gallons, the high hazard chemical incidental spill response procedure will be implemented. The beginning of the Contingency Plan provides five individuals who can serve as the emergency coordinator and provides their contact information. The plan includes lists of names and types of hazardous wastes present on site.
Additionally, the contingency plan includes a list of emergency equipment and support including fire extinguishers, emergency PPE, eye wash stations, first aid kits, and spill containment kits. The location of these items can be found in the facility map in the beginning of the plan and the list outlines the capacity of each item. The Plan also includes location and directions for how to use their "Pump House" or fire pump system.
The inspector also requested documentation that the latest version of the Contingency Plan has been submitted to local emergency responders. Mary McCoy provided a list of tracking results from USPS, sent in October 2023. She also provided email correspondence from December 2023 between herself and the Village of Coxsackie Police Department, the County Sheriff's Office, Veolia Emergency Response, Albany Medical
10
RCRA Compliance Branch INSPECTION REPORT
Services, New York State Emergency Response Commission, and the local Fire department confirming the receipt of Ducommun's Contingency Plan; this documentation can be found in Attachment 9.
Training Records: Every Employee of Ducommun is required to take an initial RCRA training and refresher training every year. Training records were reviewed on site during the inspection, all records were up to date.
Waste Profiles: Ducommun provided the current waste profiles for the "Spent Garnet" dated June 14, 2024, and "Vault Sediment" dated June 14, 2024. The Spent Garnet is profiled as non-hazardous waste based on analytical TCLP results from 2018 being below regulatory detection limits for chromium and generator knowledge (see Attachment 5). The Vault Sediment from the underground settling tanks is profiled as non-hazardous waste based on 2023 analytical TCLP results (see Attachment 3).
Waste Analytical: Analytical testing for the adhesive sealants, spent garnet, vault sediment, and wastewater discharged to the POTW were provided by Ducommun at the request of the inspector. The analytical results from 6/17/2024 for the adhesive sealant showed that it was non-hazardous (see Attachment 10). At the time of the inspection, the two adhesive sealant totes were labeled as hazardous waste, but Ms. McCoy stated they were waiting for these analytical results to come back.
Analytical testing is conducted every year for the wastewater being sent to the POTW, Ducommun provided the 2023 results showing the wastewater is non-hazardous (see Attachment 4). The analytical results for non-hazardous Spent Garnet and Vault Sediment are attached to the waste profiles discussed above.
Manifests: The inspector reviewed hazardous and non-hazardous waste manifests provided by Ducommun and viewed on RCRAInfo. All hazardous waste is picked up by Veolia ES Technical Solutions (NJD080631369) and transferred to Freehold Cartage Inc. (NJD054126164). Freehold Cartage then transports the waste to one of two designated disposal facilities - Veolia ES Technical Solutions (NJD980536593) in Flanders, NJ or Stablex Canada (NYD98075615) in Blainville, QC, Canada. Example manifests are provided in Attachment 11.
Weekly CAA Inspections: Ducommun provided its year-to-date weekly CAA inspection log. The inspection log was reviewed on site during the inspection; the records were up to date and all weeks were accounted for.
11
RCRA Compliance Branch INSPECTION REPORT
SECTION III - AREAS OF CONCERN
The presentation of areas of concern does not constitute a formal compliance determination or violation.
Regulatory Concerns
1. 6 NYCRR 373-3.9(d)(1) states that "A container holding hazardous waste must always be closed during storage, except when it is necessary to add or remove waste. ". The inspector observed a tote used to accumulate hazardous acetone debris in the CAA. The top of the tote was completely open, such that it was open even when waste was not actively being added or removed (see Photograph 14, Attachment 1). Additionally, the inspector observed an open tote that was used to accumulate hazardous paint debris also stored in the CAA. The top of the tote was placed inside the totes, such that it was open even when waste was not actively being added or removed (see Photograph 18, Attachment 1).
2. 6 NYCRR 372.2(a)(8)(i)(2) states that "marks the containers with the words "Hazardous Waste" and with other words that identify the contents of the containers." The inspector observed two totes used to accumulate hazardous paint debris and acetone debris in the CAA. The totes were labeled as "hazardous waste" but did not contain an indication of the hazards of their contents (see Photograph 13 and 17, Attachment 1).
3. 6 NYCRR 372.2(a)(8)(ii) states that " ... the date upon which each period of accumulation begins must be clearly marked and visible for inspection on all containers." The inspector observed two totes used to accumulate hazardous paint debris and acetone debris in the CAA. The totes were labeled as "hazardous waste" but did not contain an accumulation start date (see Photograph 13 and 17, Attachment 1).
4. 6 NYCRR 372.2(a)(8)(ii) states that "... a generator may accumulate hazardous waste on-site of generation for a period of 90 days or less..." The inspector observed a 5-gallon carboy containing hazardous corrosive waste stored past the 90-day accumulation limit with an accumulation start date of 9/11/2023 inside the CAA (see Photograph 11, Attachment 1)
5. 6 NYCRR 374-2.3(c)(4)(i) states that "Every container and aboveground used oil tank used to store used oil at a generator facility must be clearly labeled or marked with the words "Used Oil"." The inspector observed a 55-gallon drum and a 5-gallon container storing used oil without a label or marking inside the Blank Cell Area; and one 55-gallon drum storing used oil in the used oil storage area without a label.
12
RCRA Compliance Branch INSPECTION REPORT
Closing Conference
The closing conference took place on June 12, 2024, at approximately 1:30 pm. Attending from the facility were Mary McCoy, Robert Hasenkopf, Sunder Shelhamer and Millage Howe. Inspector Damiano was in attendance for the closing conference. Inspector Damiano discussed preliminary areas of concern and reviewed the list of documents he requested as follow-up to the inspection. The closing meeting ended at approximately 2:00 pm on June 12, 2024.
List of Attachments
These attachments are referenced throughout this report: Attachment 1: Photolog Attachment 2: POTW Response Regarding Permit Attachment 3: Vault Sediment Waste Determination Attachment 4: Wastewater Analytical Attachment 5: Garnet Waste Determination Attachment 6: Facility Follow up Email to EPA Attachment 7: Facility Follow-up Photographs Attachment 8: RCRA Contingency Plan Attachment 9: Emergency Responders Receipts Attachment 10: Adhesives Sealant Waste Determination Attachment 11: Waste Manifest Examples
Post-Inspection Facility Correspondence
Following the inspection, ERG provided a file transfer protocol link to Ducommun to allow them to upload pending documents requested during the inspection. Documents were uploaded by the facility, with the final documents uploaded on June 18, 2024.
13
RCRA Compliance Branch INSPECTION REPORT
Attachment 01 Photographic Log
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #1 (DSCN7348)
Date: 06/12/2024 Time: 09:51
Taken by: Vince Damiano
Comments: View of 55-gallon used oil drum in Blank Cell Area missing the words `Used Oil' on the label.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #2 (DSCN7349)
Date: 06/12/2024 Time: 09:51
Taken by: Vince Damiano
Comments: View of 5-gallon container of used oil in Blank Cell Area which was unlabeled.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #3 (DSCN7350)
Date: 06/12/2024 Time: 09:51
Taken by: Vince Damiano
Comments: Another view of 5-gallon container of used oil in Blank Cell Area which was unlabeled.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #4 (DSCN73451)
Date: 06/12/2024 Time: 09:54
Taken by: Vince Damiano
Comments View of cardboard tote found on loading dock by CAA containing electronic waste, no areas of concern noted.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #5 (DSCN7352)
Date: 06/12/2024 Time: 09:54
Taken by: Vince Damiano
Comments: View of cardboard tote found on loading dock by CAA containing electronic waste, no areas of concern noted.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #6 (DSCN7353)
Date: 06/12/2024 Time: 10:04
Taken by: Vince Damiano
Comments: View of two 55-gallon drums containing hazardous paint waste at VS3 paint booth SAA.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #7 (DSCN7354)
Date: 06/12/2024 Time: 10:04
Taken by: Vince Damiano
Comments: Closeup view of label on flammable enamel slow drain 55-gallon drum in VS3 paint booth SAA.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #8 (DSCN7355)
Date: 06/12/2024 Time: 10:04
Taken by: Vince Damiano
Comments: Closeup view of label on flammable enamel quick drain 55-gallon drum in VS3 paint booth SAA.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #9 (DSCN7356)
Date: 06/12/2024 Time: 10:05
Taken by: Vince Damiano
Comments View inside of expired paint storage cabinet at VS3 paint booth, facility said paint is expired but not considered waste as it is used for training and troubleshooting purposes.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #10 (DSCN7357)
Date: 06/12/2024 Time: 10:05
Taken by: Vince Damiano
Comments: View of outside the expired paint storage cabinet at VS3 paint booth.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #11 (DSCN7358)
Date: 06/12/2024 Time: 10:11
Taken by: Vince Damiano
Comments: View of 5-gallon carboy containing hydrofluoric acid and chromic acid inside bay 1 of CAA with accumulation start date of 9/11/2023.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #12 (DSCN7359)
Date: 06/12/2024 Time: 10:11
Taken by: Vince Damiano
Comments: Another view of 5-gallon carboy containing hydrofluoric acid and chromic acid inside bay 1 of CAA with accumulation start date of 9/11/2023.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #13 (DSCN7360)
Date: 06/12/2024 Time: 10:15
Taken by: Vince Damiano
Comments: View of label on tote containing acetone debris inside bay 2 of CAA. The label did not contain an accumulation start date or indication of the hazards of its contents.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #14 (DSCN7361)
Date: 06/12/2024 Time: 10:15
Taken by: Vince Damiano
Comments: View of acetone debris tote seen in Photograph 13 stored with the top of the container open.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #15 (DSCN7362)
Date: 06/12/2024 Time: 10:16
Taken by: Vince Damiano
Comments: View of label on tote containing adhesive/sealant debris inside bay 2 of CAA. The label did not contain an accumulation start date or indication of hazards of its contents.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #16 (DSCN7363)
Date: 06/12/2024 Time: 10:16
Taken by: Vince Damiano
Comments: View of tote containing adhesive/sealant debris inside bay 2 of CAA. The label did not contain an accumulation start date or indication of hazards of its contents.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #17 (DSCN7364)
Date: 06/12/2024 Time: 10:17
Taken by: Vince Damiano
Comments: View of label on tote containing paint debris inside bay 2 of CAA. The label did not contain an accumulation start date or indication of hazards of its contents.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #18 (DSCN7365)
Date: 06/12/2024 Time: 10:17
Taken by: Vince Damiano
Comments: View of paint debris tote seen in Photograph 17 stored with the top of the container open.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #19 (DSCN7366)
Date: 06/12/2024 Time: 10:17
Taken by: Vince Damiano
Comments: View of second tote containing adhesive/sealant debris inside bay 2 of CAA. The label did not contain an indication of hazards of its contents.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #20 (DSCN7367)
Date: 06/12/2024 Time: 10:24
Taken by: Vince Damiano
Comments: View of 55-gallon drum of used oil and 55gallon drum of oily debris in used oil storage area.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #21 (DSCN7368)
Date: 06/12/2024 Time: 10:27
Taken by: Vince Damiano
Comments: View of one 5-gallon container of universal waste batteries and two 5gallon containers of universal waste aerosol cans.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #22 (DSCN7369)
Date: 06/12/2024 Time: 10:27
Taken by: Vince Damiano
Comments: View of labels on universal waste aerosol can containers with accumulation start dates 9/24/2023 and 3/19/2024.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #23 (DSCN7370)
Date: 06/12/2024 Time: 11:39
Taken by: Vince Damiano
Comments: View of communication device and fire extinguisher outside of CAA.
Photograph
Ducommun Aero Structures Inspection Photolog June 12, 2024
Identification/Notes Photo #24 (DSCN7371)
Date: 06/12/2024 Time: 11:40
Taken by: Vince Damiano
Comments: Signage for hazardous waste spill response area.
Photograph
RCRA Compliance Branch INSPECTION REPORT
Attachment 02 POTW Response Regarding Permit
McCoy, Mary
From: Sent: To: Subject:
Brock Juusola <bjuusola@delawareengineering.com> Friday, March 1, 2024 12:36 PM McCoy, Mary; David Varade RE: DAS NY Wastewater Permit
This email originated from outside Ducommun. Hover your mouse over any link to verify it. Do not click any links or open any attachments unless you trust the sender and know the content is safe.
Mary,
My understanding that is that at some point in the past your process was reviewed and at that time it was determined that you are not a "categorical pretreatment facility" and a permit was not required.
Thanks,
Brock Juusola, P.E. Partner
28 Madison Avenue Ext. | Albany, NY 12203 518.452.1290 x234 (office) 518.429.0087 (mobile) www.delawareengineering.com
From: McCoy, Mary <MMcCoy@ducommun.com> Sent: Friday, March 1, 2024 12:27 PM To: David Varade <wwtp2018@gmail.com>; Brock Juusola <bjuusola@delawareengineering.com> Subject: DAS NY Wastewater Permit
Greetings,
As per our conversation on February 28, DAS NY is not required to have a wastewater permit for the Village of Coxsackie at this time.
If you could reply back to confirm or clarify, that would be great.
Mary A. McCoy, PE EHS Manager Ducommun AeroStructures New York, Inc. 171 Stacey Road Coxsackie, NY 12051-2613 203.300.7303 cell
1
Attachment 2 Page 1 of 2
518.731.4650 office mmccoy@ducommun.com www.ducommun.com Safety Suggestions: EHSSupportNY@ducommun.com CONFIDENTIALITY NOTICE: This email transmission and any attachments to it may contain confidential information proprietary to Ducommun Incorporated and its subsidiaries or their customers. If you are not the intended recipient, a person responsible for delivering it to the intended recipient, or have received this transmission in error, please notify the sender and destroy the original transmission and its attachments without reading or saving.
2 Attachment 2 Page 2 of 2
RCRA Compliance Branch INSPECTION REPORT
Attachment 03 Vault Sediment Waste Determination
Form No.: Last Reviewed Date: Revision No.: Coxsackie, New York
F-00663 Hazardous Waste Determination Worksheet -
10/17/2023 A
Authorized By: WI-00216 Environmental Management System - Requirements
Page 1 of 2
DCO Site:
Coxsackie 171 Stacey Road Coxsackie, NY 12051-2613
EPA ID:
NYR 000 219 550
Date:
6/14/2024
By:
Mary McCoy
Waste Stream Common Name:
Vault sediment
Check one: RCRA Haz Waste
Non-RCRA Haz Waste
Not Haz Waste
RCRA Waste Codes:
NA
State Waste Codes:
NA
0
Source Code:
#N/A
Form Code:
#N/A
Management Method:
#N/A
(For California sites, if this waste is subject to 22 CCR 66266.1 and is not recycled, attach justification.)
UN#, Proper Shipping Name, Hazard Class, Packing Group: NA
ERG:
NA
Check one: Ongoing
RQ Threshold:
NA
Intermittent
One-time
Other information: The sediment from the settling vaults associated with the wastewater treatment plant ("pH Lab") is non-hazardous based on 2023 TCLP results. See attached.
Waste generation process (listed, characteristic); chemicals used; location within facility:
After pH neutralization at the pH Lab, the wastewater is discharge to the POTW via settling vaults. Sediment collects at the bottom of the vaults.
Attachment 3 Page 1 of 18
#=CL#
LIMS USE: FR - MARY MCCOY LIMS OBJECT ID: 70275899
December 27, 2023
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Mary McCoy Ducommun Aerostructures 171 Stacy Road Coxsackie, NY 12051
RE: Project: WASTEWATER TREATMENT SL 10/28 Pace Project No.: 70275899
Dear Mary McCoy: Enclosed are the analytical results for sample(s) received by the laboratory on October 31, 2023. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report.
The test results provided in this final report were generated by each of the following laboratories within the Pace Network: Pace Analytical Services - Melville
If you have any questions concerning this report, please feel free to contact me.
Sincerely,
Matthew T. Nemeth matthew.nemeth@pacelabs.com 516-370-6042 Project Manager
Enclosures
cc: Linda Barley, Ducommun Aerostructures Pedro Dumaua, Ducommun Aerostructures Eugenia Lighthouse, Ducommun Incorporated
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 2 of 18
Page 1 of 17
#=CP#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Project: Pace Project No.:
WASTEWATER TREATMENT SL 10/28 70275899
Pace Analytical Services Long Island 575 Broad Hollow Rd, Melville, NY 11747 Connecticut Certification #: PH-0435 Delaware Certification # NY 10478 Maryland Certification #: 208 Massachusetts Certification #: M-NY026 New Hampshire Certification #: 2987
CERTIFICATIONS
New Jersey Certification #: NY158 New York Certification #: 10478 Primary Accrediting Body Pennsylvania Certification #: 68-00350 Rhode Island Certification #: LAO00340 Virginia Certification # 460302
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 3 of 18
Page 2 of 17
#=AR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
ANALYTICAL RESULTS
Project: Pace Project No.:
WASTEWATER TREATMENT SL 10/28 70275899
Sample: VAULT
Lab ID: 70275899001 Collected: 10/27/23 09:00 Received: 10/31/23 08:00 Matrix: Solid
Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions.
Parameters
Results
Units
Report Limit DF
Prepared
Analyzed
CAS No.
6010 MET ICP
Arsenic Barium Cadmium Chromium Lead Selenium Silver 6010 MET ICP, TCLP
Chromium 7471 Mercury
Mercury Percent Moisture
Percent Moisture
Analytical Method: EPA 6010C Preparation Method: EPA 3050B Pace Analytical Services - Melville
3.0 <23.2
1.1 441 1.1 <1.2 <1.2
mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg
1.2 1 11/03/23 07:00 11/03/23 14:59 7440-38-2 23.2 1 11/03/23 07:00 11/03/23 14:59 7440-39-3 0.29 1 11/03/23 07:00 11/03/23 14:59 7440-43-9
1.2 1 11/03/23 07:00 11/03/23 14:59 7440-47-3 0.58 1 11/03/23 07:00 11/03/23 14:59 7439-92-1
1.2 1 11/03/23 07:00 11/03/23 14:59 7782-49-2 1.2 1 11/03/23 07:00 11/03/23 14:59 7440-22-4
Analytical Method: EPA 6010C Preparation Method: EPA 3005A Leachate Method/Date: EPA 1311; 12/15/23 22:20 Pace Analytical Services - Melville
<0.050
mg/L
0.050 1 12/19/23 07:06 12/19/23 17:39 7440-47-3
Analytical Method: EPA 7471B Preparation Method: EPA 7471B Pace Analytical Services - Melville
<0.063
mg/kg
0.063 1 11/07/23 07:00 11/07/23 14:23 7439-97-6
Analytical Method: ASTM D2216-05M Pace Analytical Services - Melville
43.3
%
0.10 1
11/01/23 08:04
Qual
Date: 12/27/2023 05:09 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 4 of 18
Page 3 of 17
#=AR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
ANALYTICAL RESULTS
Project: Pace Project No.:
WASTEWATER TREATMENT SL 10/28 70275899
Sample: CACO3 TI#2
Lab ID: 70275899002 Collected: 10/28/23 09:30 Received: 10/31/23 08:00 Matrix: Solid
Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions.
Parameters
Results
Units
Report Limit DF
Prepared
Analyzed
CAS No.
6010 MET ICP
Aluminum Cobalt Copper Iron Manganese Molybdenum Nickel Vanadium 6010 MET ICP, TCLP
Arsenic Barium Cadmium Chromium Lead Selenium Silver 7470 Mercury, TCLP
Mercury 7471 Mercury
Mercury Percent Moisture
Percent Moisture
Analytical Method: EPA 6010C Preparation Method: EPA 3050B Pace Analytical Services - Melville
28100 97.3 82.7 6240 317 18.4 1350 6500
mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg
88.5 1 11/03/23 07:00 11/03/23 15:02 7429-90-5 22.1 1 11/03/23 07:00 11/03/23 15:02 7440-48-4 11.1 1 11/03/23 07:00 11/03/23 15:02 7440-50-8 44.2 1 11/03/23 07:00 11/03/23 15:02 7439-89-6
6.6 1 11/03/23 07:00 11/03/23 15:02 7439-96-5 8.8 1 11/03/23 07:00 11/03/23 15:02 7439-98-7 17.7 1 11/03/23 07:00 11/03/23 15:02 7440-02-0 22.1 1 11/03/23 07:00 11/03/23 15:02 7440-62-2
Analytical Method: EPA 6010C Preparation Method: EPA 3005A Leachate Method/Date: EPA 1311; 10/31/23 23:09 Pace Analytical Services - Melville
<0.010 <0.20
<0.0025 0.027 0.029
<0.010 <0.010
mg/L mg/L mg/L mg/L mg/L mg/L mg/L
0.010 1 11/03/23 08:16 11/03/23 17:28 7440-38-2 0.20 1 11/03/23 08:16 11/03/23 17:28 7440-39-3
0.0025 1 11/03/23 08:16 11/03/23 17:28 7440-43-9 0.010 1 11/03/23 08:16 11/03/23 17:28 7440-47-3
0.0050 1 11/03/23 08:16 11/03/23 17:28 7439-92-1 0.010 1 11/03/23 08:16 11/03/23 17:28 7782-49-2 0.010 1 11/03/23 08:16 11/03/23 17:28 7440-22-4
Analytical Method: EPA 7470A Preparation Method: EPA 7470A Leachate Method/Date: EPA 1311; 10/31/23 23:09 Pace Analytical Services - Melville
<0.00020
mg/L
0.00020 1 11/06/23 06:00 11/06/23 13:33 7439-97-6
Analytical Method: EPA 7471B Preparation Method: EPA 7471B Pace Analytical Services - Melville
<0.034
mg/kg
0.034 1 11/07/23 07:00 11/07/23 14:24 7439-97-6
Analytical Method: ASTM D2216-05M Pace Analytical Services - Melville
<0.10
%
0.10 1
11/01/23 08:04
Qual
Date: 12/27/2023 05:09 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 5 of 18
Page 4 of 17
#=AR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
ANALYTICAL RESULTS
Project: Pace Project No.:
WASTEWATER TREATMENT SL 10/28 70275899
Sample: CACO3 TI#1
Lab ID: 70275899003 Collected: 10/28/23 09:45 Received: 10/31/23 08:00 Matrix: Solid
Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions.
Parameters
Results
Units
Report Limit DF
Prepared
Analyzed
CAS No.
6010 MET ICP
Aluminum Cobalt Copper Iron Manganese Molybdenum Nickel Vanadium 6010 MET ICP, TCLP
Arsenic Barium Cadmium Chromium Lead Selenium Silver 7470 Mercury, TCLP
Mercury 7471 Mercury
Mercury Percent Moisture
Percent Moisture
Analytical Method: EPA 6010C Preparation Method: EPA 3050B Pace Analytical Services - Melville
24000 116 191
8890 688 83.3
3510 6360
mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg
93.6 1 11/03/23 07:00 11/03/23 15:05 7429-90-5 23.4 1 11/03/23 07:00 11/03/23 15:05 7440-48-4 11.7 1 11/03/23 07:00 11/03/23 15:05 7440-50-8 46.8 1 11/03/23 07:00 11/03/23 15:05 7439-89-6
7.0 1 11/03/23 07:00 11/03/23 15:05 7439-96-5 9.4 1 11/03/23 07:00 11/03/23 15:05 7439-98-7 18.7 1 11/03/23 07:00 11/03/23 15:05 7440-02-0 23.4 1 11/03/23 07:00 11/03/23 15:05 7440-62-2
Analytical Method: EPA 6010C Preparation Method: EPA 3005A Leachate Method/Date: EPA 1311; 10/31/23 23:09 Pace Analytical Services - Melville
<0.010 <0.20
<0.0025 0.066 0.017
<0.010 <0.010
mg/L mg/L mg/L mg/L mg/L mg/L mg/L
0.010 1 11/03/23 08:16 11/03/23 17:30 7440-38-2 0.20 1 11/03/23 08:16 11/03/23 17:30 7440-39-3
0.0025 1 11/03/23 08:16 11/03/23 17:30 7440-43-9 0.010 1 11/03/23 08:16 11/03/23 17:30 7440-47-3
0.0050 1 11/03/23 08:16 11/03/23 17:30 7439-92-1 0.010 1 11/03/23 08:16 11/03/23 17:30 7782-49-2 0.010 1 11/03/23 08:16 11/03/23 17:30 7440-22-4
Analytical Method: EPA 7470A Preparation Method: EPA 7470A Leachate Method/Date: EPA 1311; 10/31/23 23:09 Pace Analytical Services - Melville
<0.00020
mg/L
0.00020 1 11/06/23 06:00 11/06/23 13:35 7439-97-6
Analytical Method: EPA 7471B Preparation Method: EPA 7471B Pace Analytical Services - Melville
<0.034
mg/kg
0.034 1 11/07/23 07:00 11/07/23 14:26 7439-97-6
Analytical Method: ASTM D2216-05M Pace Analytical Services - Melville
1.1
%
0.10 1
11/01/23 08:05
Qual
Date: 12/27/2023 05:09 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 6 of 18
Page 5 of 17
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
WASTEWATER TREATMENT SL 10/28 70275899
QC Batch: QC Batch Method:
326524 EPA 7470A
Associated Lab Samples: 70275899002, 70275899003
Analysis Method: Analysis Description: Laboratory:
EPA 7470A 7470 Mercury TCLP Pace Analytical Services - Melville
METHOD BLANK: 1669310 Associated Lab Samples: 70275899002, 70275899003
Mercury
Parameter
Units mg/L
Matrix: Water
Blank Result
<0.00020
Reporting Limit
0.00020
Analyzed 11/06/23 13:22
Qualifiers
METHOD BLANK: 1668811 Associated Lab Samples: 70275899002, 70275899003
Mercury
Parameter
Units mg/L
Matrix: Water
Blank Result
<0.00020
Reporting Limit
0.00020
Analyzed 11/06/23 13:25
Qualifiers
LABORATORY CONTROL SAMPLE: 1669311
Mercury
Parameter
Units mg/L
Spike Conc.
0.001
LCS Result
0.00098
LCS % Rec
98
% Rec Limits
80-120
Qualifiers
MATRIX SPIKE SAMPLE:
Mercury
Parameter
1669312
Units mg/L
70276359002 Result
<0.00020
Spike Conc.
0.001
MS Result
0.00099
MS % Rec
98
% Rec Limits
75-125
Qualifiers
SAMPLE DUPLICATE: 1669313
Mercury
Parameter
Units mg/L
70276359002 Result
<0.00020
Dup Result
<0.00020
RPD
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 12/27/2023 05:09 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 7 of 18
Page 6 of 17
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
WASTEWATER TREATMENT SL 10/28 70275899
QC Batch:
326642
Analysis Method:
QC Batch Method: EPA 7471B
Analysis Description:
Laboratory:
Associated Lab Samples: 70275899001, 70275899002, 70275899003
EPA 7471B 7471 Mercury Pace Analytical Services - Melville
METHOD BLANK: 1669937
Matrix: Solid
Associated Lab Samples: 70275899001, 70275899002, 70275899003
Parameter
Units
Blank Result
Reporting Limit
Mercury
mg/kg
<0.039
0.039
Analyzed 11/07/23 14:13
Qualifiers
LABORATORY CONTROL SAMPLE: 1669938
Mercury
Parameter
Units mg/kg
Spike Conc.
0.2
LCS Result
0.19
LCS % Rec
99
% Rec Limits
80-120
Qualifiers
MATRIX SPIKE SAMPLE:
Mercury
Parameter
1669939
Units mg/kg
70275895001 Result
0.050
Spike Conc.
0.22
MS Result
0.28
MS % Rec
106
% Rec Limits
80-120
Qualifiers
SAMPLE DUPLICATE: 1669940
Mercury
Parameter
Units mg/kg
70275895001 Result
0.050
Dup Result
0.049
RPD
Qualifiers
2
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 12/27/2023 05:09 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 8 of 18
Page 7 of 17
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
WASTEWATER TREATMENT SL 10/28 70275899
QC Batch:
326198
Analysis Method:
QC Batch Method: EPA 3050B
Analysis Description:
Laboratory:
Associated Lab Samples: 70275899001, 70275899002, 70275899003
EPA 6010C 6010 MET Pace Analytical Services - Melville
METHOD BLANK: 1667298
Matrix: Solid
Associated Lab Samples: 70275899001, 70275899002, 70275899003
Parameter
Units
Blank Result
Reporting Limit
Aluminum Arsenic Barium Cadmium Chromium Cobalt Copper Iron Lead Manganese Molybdenum Nickel Selenium Silver Vanadium
mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg
<10.5
10.5
<0.52
0.52
<10.5
10.5
<0.13
0.13
<0.52
0.52
<2.6
2.6
<1.3
1.3
<5.2
5.2
<0.26
0.26
<0.79
0.79
<1.0
1.0
<2.1
2.1
<0.52
0.52
<0.52
0.52
<2.6
2.6
Analyzed
11/03/23 14:21 11/03/23 14:21 11/03/23 14:21 11/03/23 14:21 11/03/23 14:21 11/03/23 14:21 11/03/23 14:21 11/03/23 14:21 11/03/23 14:21 11/03/23 14:21 11/03/23 14:21 11/03/23 14:21 11/03/23 14:21 11/03/23 14:21 11/03/23 14:21
Qualifiers
LABORATORY CONTROL SAMPLE: 1667299
Parameter
Aluminum Arsenic Barium Cadmium Chromium Cobalt Copper Iron Lead Manganese Molybdenum Nickel Selenium Silver Vanadium
Units
mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg
Spike Conc.
7210 79
314 145 209 218 130 12800 241 502 191 316 118 51.6 80.1
LCS Result
7370 76.9 321 152 232 234 130 11300 245 506 198 337 117 50.6 84.1
LCS % Rec
102 97
102 105 111 107 100
88 102 101 104 107
99 98 105
% Rec Limits
47-153 82-118 80-120 79-121 80-121 80-120 83-118 61-139 82-118 79-121 79-121 79-121 78-123 78-122 77-123
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 12/27/2023 05:09 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 9 of 18
Page 8 of 17
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
WASTEWATER TREATMENT SL 10/28 70275899
MATRIX SPIKE SAMPLE:
Parameter
Aluminum Arsenic Barium Cadmium Chromium Cobalt Copper Iron Lead Manganese Molybdenum Nickel Selenium Silver Vanadium
1667880
Units
mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg
70275895001 Result
9400 9.5
38.1 0.12J
11.8 4.3 11.0 11000 31.6 222 0.45J 8.6 <0.55 <0.55 21.3
Spike Conc.
719 28.8 28.8 28.8 28.8 28.8 28.8 288 28.8 28.8 57.5 28.8 28.8 14.4 28.8
MS Result
12900 35.6 77.6 27.4 43.4 31.9 38.9
12900 61.0 266 54.8 37.4 25.5 14.7 52.7
MS % Rec
493 91
138 95 110 96 97
681 102 153
94 100
89 102 109
% Rec Limits
Qualifiers
75-125 M1 75-125 75-125 M1 75-125 75-125 75-125 75-125 75-125 M1 75-125 75-125 M1 75-125 75-125 75-125 75-125 75-125
SAMPLE DUPLICATE: 1667879
Parameter
Aluminum Arsenic Barium Cadmium Chromium Cobalt Copper Iron Lead Manganese Molybdenum Nickel Selenium Silver Vanadium
Units
mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg
70275895001 Result
9400 9.5
38.1 0.12J
11.8 4.3 11.0 11000 31.6 222 0.45J 8.6 <0.55 <0.55 21.3
Dup Result
10300 8.9
41.7 <0.14
14.0 5.1
16.9 12900
32.3 239 <1.1 9.7 <0.55 <0.55 23.6
RPD
Qualifiers
9 6 9
17 17 43 D6 16
2 7
11
10
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 12/27/2023 05:09 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 10 of 18
Page 9 of 17
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
WASTEWATER TREATMENT SL 10/28 70275899
QC Batch: QC Batch Method:
326310 EPA 3005A
Associated Lab Samples: 70275899002, 70275899003
Analysis Method: Analysis Description: Laboratory:
EPA 6010C 6010 MET TCLP Pace Analytical Services - Melville
METHOD BLANK: 1667890 Associated Lab Samples: 70275899002, 70275899003
Arsenic Barium Cadmium Chromium Lead Selenium Silver
Parameter
Units
mg/L mg/L mg/L mg/L mg/L mg/L mg/L
Matrix: Water
Blank Result
<0.010 <0.20
<0.0025 <0.010
<0.0050 <0.010 <0.010
Reporting Limit
0.010 0.20
0.0025 0.010
0.0050 0.010 0.010
Analyzed
11/03/23 16:55 11/03/23 16:55 11/03/23 16:55 11/03/23 16:55 11/03/23 16:55 11/03/23 16:55 11/03/23 16:55
Qualifiers
METHOD BLANK: 1666667 Associated Lab Samples: 70275899002, 70275899003
Arsenic Barium Cadmium Chromium Lead Selenium Silver
Parameter
Units
mg/L mg/L mg/L mg/L mg/L mg/L mg/L
Matrix: Water
Blank Result
<0.010 <0.20
<0.0025 <0.010
<0.0050 <0.010 <0.010
Reporting Limit
0.010 0.20
0.0025 0.010
0.0050 0.010 0.010
Analyzed
11/03/23 18:00 11/03/23 18:00 11/03/23 18:00 11/03/23 18:00 11/03/23 18:00 11/03/23 18:00 11/03/23 18:00
Qualifiers
LABORATORY CONTROL SAMPLE: 1667891
Arsenic Barium Cadmium Chromium Lead Selenium Silver
Parameter
Units
mg/L mg/L mg/L mg/L mg/L mg/L mg/L
Spike Conc.
0.5 0.5 0.5 0.5 0.5 0.5 0.25
LCS Result
0.48 0.50 0.50 0.51 0.51 0.48 0.24
LCS % Rec
96 99 100 102 101 96 97
% Rec Limits
80-120 80-120 80-120 80-120 80-120 80-120 80-120
Qualifiers
MATRIX SPIKE SAMPLE:
Arsenic
Parameter
1667893
Units mg/L
70276026001 Result
<0.010
Spike Conc.
0.1
MS Result
0.091
MS % Rec
91
% Rec Limits
75-125
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 12/27/2023 05:09 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 11 of 18
Page 10 of 17
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
WASTEWATER TREATMENT SL 10/28 70275899
MATRIX SPIKE SAMPLE:
Barium Cadmium Chromium Lead Selenium Silver
Parameter
1667893
Units
mg/L mg/L mg/L mg/L mg/L mg/L
70276026001 Result
<0.20 <0.0025
<0.010 0.17
<0.010 <0.010
Spike Conc.
0.1 0.1 0.1 0.1 0.1 0.05
MS Result
<0.20 0.094 0.098
0.26 0.088 0.045
MS % Rec
90 94 97 90 88 90
% Rec Limits
75-125 75-125 75-125 75-125 75-125 75-125
Qualifiers
SAMPLE DUPLICATE: 1667892
Arsenic Barium Cadmium Chromium Lead Selenium Silver
Parameter
Units
mg/L mg/L mg/L mg/L mg/L mg/L mg/L
70276026001 Result
<0.010 <0.20
<0.0025 <0.010 0.17 <0.010 <0.010
Dup Result
<0.010 <0.20
<0.0025 <0.010 0.17 <0.010 <0.010
RPD
Qualifiers
1
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 12/27/2023 05:09 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 12 of 18
Page 11 of 17
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
WASTEWATER TREATMENT SL 10/28 70275899
QC Batch: QC Batch Method:
331233 EPA 3005A
Associated Lab Samples: 70275899001
Analysis Method: Analysis Description: Laboratory:
EPA 6010C 6010 MET TCLP Pace Analytical Services - Melville
METHOD BLANK: 1697319 Associated Lab Samples: 70275899001
Chromium
Parameter
Units mg/L
Matrix: Water
Blank Result
<0.010
Reporting Limit
0.010
Analyzed 12/19/23 17:34
Qualifiers
METHOD BLANK: 1669849 Associated Lab Samples: 70275899001
Chromium
Parameter
Units mg/L
Matrix: Water
Blank Result
<0.050
Reporting Limit
0.050
Analyzed 12/19/23 17:52
Qualifiers
LABORATORY CONTROL SAMPLE: 1697320
Chromium
Parameter
Units mg/L
Spike Conc.
0.5
LCS Result
0.48
LCS % Rec
96
% Rec Limits
80-120
Qualifiers
MATRIX SPIKE SAMPLE:
Chromium
Parameter
1697322
Units mg/L
70275899001 Result
<0.050
Spike Conc.
0.5
MS Result
0.48
MS % Rec
95
% Rec Limits
75-125
Qualifiers
SAMPLE DUPLICATE: 1697321
Chromium
Parameter
Units mg/L
70275899001 Result
<0.050
Dup Result
<0.050
RPD
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 12/27/2023 05:09 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 13 of 18
Page 12 of 17
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
WASTEWATER TREATMENT SL 10/28 70275899
QC Batch:
325952
Analysis Method:
QC Batch Method: ASTM D2216-05M
Analysis Description:
Laboratory:
Associated Lab Samples: 70275899001, 70275899002, 70275899003
ASTM D2216-05M Dry Weight/Percent Moisture Pace Analytical Services - Melville
SAMPLE DUPLICATE: 1665498
Parameter Percent Moisture
Units %
70275896001 Result
7.1
Dup Result
7.0
RPD
Qualifiers
1
SAMPLE DUPLICATE: 1665499
Parameter Percent Moisture
Units %
70276026001 Result
0.82
Dup Result
0.84
RPD
Qualifiers
2
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 12/27/2023 05:09 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 14 of 18
Page 13 of 17
#=QL#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALIFIERS
Project: Pace Project No.:
WASTEWATER TREATMENT SL 10/28 70275899
DEFINITIONS
DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot.
ND - Not Detected at or above adjusted reporting limit.
TNTC - Too Numerous To Count
J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit.
MDL - Adjusted Method Detection Limit.
PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values.
LCS(D) - Laboratory Control Sample (Duplicate)
MS(D) - Matrix Spike (Duplicate)
DUP - Sample Duplicate
RPD - Relative Percent Difference
NC - Not Calculable.
SG - Silica Gel - Clean-Up
U - Indicates the compound was analyzed for, but not detected. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes.
TNI - The NELAC Institute.
BATCH QUALIFIERS
Batch: 326352
[1]
The post digestion spike for sample 70276026001 (PDS 1668164) did not meet acceptance criteria for Silver.
Batch: 326357
[1]
The serial dilution for sample 70275895001 (SD 1668171) did not meet acceptance criteria for Arsenic, Calcium, Iron,
Sodium, Tin, and Zinc.
[2]
The post digestions spike for sample 70275895001 (PDS 1668172) did not meet acceptance criteria for all analytes
except for Potassium.
ANALYTE QUALIFIERS
D6
The precision between the sample and sample duplicate exceeded laboratory control limits.
M1
Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.
Date: 12/27/2023 05:09 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 15 of 18
Page 14 of 17
#=CR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA CROSS REFERENCE TABLE
Project: Pace Project No.:
WASTEWATER TREATMENT SL 10/28 70275899
Lab ID
70275899001 70275899002 70275899003
70275899001
70275899002 70275899003
70275899002 70275899003
70275899001 70275899002 70275899003
70275899001 70275899002 70275899003
Sample ID
VAULT CACO3 TI#2 CACO3 TI#1
VAULT
CACO3 TI#2 CACO3 TI#1
CACO3 TI#2 CACO3 TI#1
VAULT CACO3 TI#2 CACO3 TI#1
VAULT CACO3 TI#2 CACO3 TI#1
QC Batch Method
EPA 3050B EPA 3050B EPA 3050B
EPA 3005A
EPA 3005A EPA 3005A
EPA 7470A EPA 7470A
EPA 7471B EPA 7471B EPA 7471B
ASTM D2216-05M ASTM D2216-05M ASTM D2216-05M
QC Batch
326198 326198 326198
331233
326310 326310
326524 326524
326642 326642 326642
325952 325952 325952
Analytical Method
EPA 6010C EPA 6010C EPA 6010C
EPA 6010C
EPA 6010C EPA 6010C
EPA 7470A EPA 7470A
EPA 7471B EPA 7471B EPA 7471B
Analytical Batch
326357 326357 326357
331269
326352 326352
326544 326544
326729 326729 326729
Date: 12/27/2023 05:09 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 3 Page 16 of 18
Page 15 of 17
Attachment 3 Page 17 of 18
Page 16 of 17
Attachment 3 Page 18 of 18
Page 17 of 17
Attachment 04 Wastewater Analytical
#=CL#
LIMS USE: FR - MARY MCCOY LIMS OBJECT ID: 70266147
August 30, 2023
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Mary McCoy Ducommun Aerostructures 171 Stacy Road Coxsackie, NY 12051
RE: Project: SEMI ANNUAL 8/8 Pace Project No.: 70266147
Dear Mary McCoy: Enclosed are the analytical results for sample(s) received by the laboratory on August 08, 2023. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report.
The test results provided in this final report were generated by each of the following laboratories within the Pace Network: Pace Analytical Services - Melville Pace Analytical Services - Greensburg
If you have any questions concerning this report, please feel free to contact me.
Sincerely,
Matthew T. Nemeth matthew.nemeth@pacelabs.com 516-370-6042 Project Manager
Enclosures
cc: Linda Barley, Ducommun Aerostructures Pedro Dumaua, Ducommun Aerostructures Eugenia Lighthouse, Ducommun Incorporated
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 1 of 30
Page 1 of 30
#=CP#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
Pace Analytical Services Pennsylvania 1638 Roseytown Rd Suites 2,3&4, Greensburg, PA 15601 ANAB DOD-ELAP Rad Accreditation #: L2417 ANABISO/IEC 17025:2017 Rad Cert#: L24170 Alabama Certification #: 41590 Arizona Certification #: AZ0734 Arkansas Certification California Certification #: 2950 Colorado Certification #: PA01547 Connecticut Certification #: PH-0694 EPA Region 4 DW Rad Florida/TNI Certification #: E87683 Georgia Certification #: C040 Guam Certification Hawaii Certification Idaho Certification Illinois Certification Indiana Certification Iowa Certification #: 391 Kansas Certification #: E-10358 Kentucky Certification #: KY90133 KY WW Permit #: KY0098221 KY WW Permit #: KY0000221 Louisiana DHH/TNI Certification #: LA010 Louisiana DEQ/TNI Certification #: 04086 Maine Certification #: 2023021 Maryland Certification #: 308 Massachusetts Certification #: M-PA1457 Michigan/PADEP Certification #: 9991
Pace Analytical Services Long Island 575 Broad Hollow Rd, Melville, NY 11747 Connecticut Certification #: PH-0435 Delaware Certification # NY 10478 Maryland Certification #: 208 Massachusetts Certification #: M-NY026 New Hampshire Certification #: 2987
CERTIFICATIONS
Missouri Certification #: 235 Montana Certification #: Cert0082 Nebraska Certification #: NE-OS-29-14 Nevada Certification #: PA014572023-03 New Hampshire/TNI Certification #: 297622 New Jersey/TNI Certification #: PA051 New Mexico Certification #: PA01457 New York/TNI Certification #: 10888 North Carolina Certification #: 42706 North Dakota Certification #: R-190 Ohio EPA Rad Approval: #41249 Oregon/TNI Certification #: PA200002-015 Pennsylvania/TNI Certification #: 65-00282 Puerto Rico Certification #: PA01457 Rhode Island Certification #: 65-00282 South Dakota Certification Tennessee Certification #: TN02867 Texas/TNI Certification #: T104704188-22-18 Utah/TNI Certification #: PA014572223-14 USDA Soil Permit #: 525-23-67-77263 Vermont Dept. of Health: ID# VT-0282 Virgin Island/PADEP Certification Virginia/VELAP Certification #: 460198 Washington Certification #: C868 West Virginia DEP Certification #: 143 West Virginia DHHR Certification #: 9964C Wisconsin Approve List for Rad
New Jersey Certification #: NY158 New York Certification #: 10478 Primary Accrediting Body Pennsylvania Certification #: 68-00350 Rhode Island Certification #: LAO00340 Virginia Certification # 460302
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 2 of 30
Page 2 of 30
#=SA#
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
Lab ID 70266147001
Sample ID EFFLUENT
70266147002 EFFLUENT
70266147003 TRIP BLANK PACE-MV = Pace Analytical Services - Melville PASI-PA = Pace Analytical Services - Greensburg
SAMPLE ANALYTE COUNT
Method EPA 608.3 EPA 608.3 EPA 200.7 SM22 3500-Cr B EPA 300.0 EPA 350.1 EPA 625.1 EPA 624.1 SM22 4500-H+B EPA 335.4 EPA 624.1
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Analysts
CGTA CGTA JWT DJM RESE BNK RP1 TJD NAA CMT TJD
Analytes Reported
Laboratory
9 PACE-MV 22 PACE-MV
7 PACE-MV 1 PACE-MV 1 PACE-MV 1 PACE-MV 62 PACE-MV 39 PACE-MV 2 PACE-MV 1 PASI-PA 39 PACE-MV
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 3 of 30
Page 3 of 30
#=AR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
ANALYTICAL RESULTS
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
Sample: EFFLUENT
Lab ID: 70266147001
Parameters
Results
Units
Collected: 08/08/23 11:30 Received: 08/08/23 16:00 Matrix: Water
Report Limit DF
Prepared
Analyzed
CAS No.
Qual
608.3 GCSV PCB
PCB-1016 (Aroclor 1016) PCB-1221 (Aroclor 1221) PCB-1232 (Aroclor 1232) PCB-1242 (Aroclor 1242) PCB-1248 (Aroclor 1248) PCB-1254 (Aroclor 1254) PCB-1260 (Aroclor 1260) Surrogates Tetrachloro-m-xylene (S) Decachlorobiphenyl (S)
608.3 GCSV Pesticides
Aldrin alpha-BHC beta-BHC delta-BHC gamma-BHC (Lindane) Chlordane (Technical) 4,4'-DDD 4,4'-DDE 4,4'-DDT Dieldrin Endosulfan I Endosulfan II Endosulfan sulfate Endrin Endrin aldehyde Heptachlor Heptachlor epoxide Methoxychlor Mirex Toxaphene Surrogates Tetrachloro-m-xylene (S) Decachlorobiphenyl (S)
200.7 Metals, Total
Cadmium Chromium Copper Lead Nickel Silver Zinc
Analytical Method: EPA 608.3 Preparation Method: EPA 608.3 Pace Analytical Services - Melville
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
1.0 1 08/15/23 13:08 08/16/23 19:27 12674-11-2 1.0 1 08/15/23 13:08 08/16/23 19:27 11104-28-2 1.0 1 08/15/23 13:08 08/16/23 19:27 11141-16-5 1.0 1 08/15/23 13:08 08/16/23 19:27 53469-21-9 1.0 1 08/15/23 13:08 08/16/23 19:27 12672-29-6 1.0 1 08/15/23 13:08 08/16/23 19:27 11097-69-1 1.0 1 08/15/23 13:08 08/16/23 19:27 11096-82-5
76
%
30
%
10-152 1 08/15/23 13:08 08/16/23 19:27 877-09-8 10-124 1 08/15/23 13:08 08/16/23 19:27 2051-24-3
Analytical Method: EPA 608.3 Preparation Method: EPA 608.3 Pace Analytical Services - Melville
<0.050
ug/L
<0.050
ug/L
<0.050
ug/L
<0.050
ug/L
<0.050
ug/L
<1.0
ug/L
<0.10
ug/L
<0.10
ug/L
<0.10
ug/L
<0.10
ug/L
0.21
ug/L
<0.10
ug/L
<0.10
ug/L
<0.10
ug/L
<0.10
ug/L
<0.050
ug/L
<0.050
ug/L
<0.50
ug/L
<0.10
ug/L
<5.0
ug/L
0.050 1 08/15/23 13:08 08/16/23 19:21 309-00-2
0.050 1 08/15/23 13:08 08/16/23 19:21 319-84-6
0.050 1 08/15/23 13:08 08/16/23 19:21 319-85-7
0.050 1 08/15/23 13:08 08/16/23 19:21 319-86-8
0.050 1 08/15/23 13:08 08/16/23 19:21 58-89-9
1.0 1 08/15/23 13:08 08/16/23 19:21 57-74-9
L1
0.10 1 08/15/23 13:08 08/16/23 19:21 72-54-8
0.10 1 08/15/23 13:08 08/16/23 19:21 72-55-9
0.10 1 08/15/23 13:08 08/16/23 19:21 50-29-3
0.10 1 08/15/23 13:08 08/16/23 19:21 60-57-1
0.050 1 08/15/23 13:08 08/16/23 19:21 959-98-8
0.10 1 08/15/23 13:08 08/16/23 19:21 33213-65-9
0.10 1 08/15/23 13:08 08/16/23 19:21 1031-07-8
0.10 1 08/15/23 13:08 08/16/23 19:21 72-20-8
0.10 1 08/15/23 13:08 08/16/23 19:21 7421-93-4
0.050 1 08/15/23 13:08 08/16/23 19:21 76-44-8
0.050 1 08/15/23 13:08 08/16/23 19:21 1024-57-3
0.50 1 08/15/23 13:08 08/16/23 19:21 72-43-5
0.10 1 08/15/23 13:08 08/16/23 19:21 2385-85-5
5.0 1 08/15/23 13:08 08/16/23 19:21 8001-35-2
82
%
32
%
10-152 1 08/15/23 13:08 08/16/23 19:21 877-09-8 10-124 1 08/15/23 13:08 08/16/23 19:21 2051-24-3
Analytical Method: EPA 200.7 Preparation Method: EPA 200.7 Pace Analytical Services - Melville
<2.5
ug/L
39.9
ug/L
<25.0
ug/L
<5.0
ug/L
<40.0
ug/L
<10.0
ug/L
<20.0
ug/L
2.5 1 08/10/23 07:26 08/10/23 14:21 7440-43-9 10.0 1 08/10/23 07:26 08/10/23 14:21 7440-47-3 25.0 1 08/10/23 07:26 08/10/23 14:21 7440-50-8
5.0 1 08/10/23 07:26 08/10/23 14:21 7439-92-1 40.0 1 08/10/23 07:26 08/10/23 14:21 7440-02-0 10.0 1 08/10/23 07:26 08/10/23 14:21 7440-22-4 20.0 1 08/10/23 07:26 08/10/23 14:21 7440-66-6
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 4 of 30
Page 4 of 30
#=AR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
ANALYTICAL RESULTS
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
Sample: EFFLUENT
Lab ID: 70266147001
Parameters
Results
Units
Collected: 08/08/23 11:30 Received: 08/08/23 16:00 Matrix: Water
Report Limit DF
Prepared
Analyzed
CAS No.
Qual
Chromium, Hexavalent Chromium, Hexavalent 300.0 IC Anions 28 Days Fluoride 350.1 Ammonia Nitrogen, Ammonia
Analytical Method: SM22 3500-Cr B Pace Analytical Services - Melville
<0.020
mg/L
0.020 1
Analytical Method: EPA 300.0 Pace Analytical Services - Melville
12.1
mg/L
0.20 2
Analytical Method: EPA 350.1 Pace Analytical Services - Melville
<0.10
mg/L
0.10 1
08/11/23 00:41 18540-29-9 H1 08/22/23 09:35 16984-48-8 08/13/23 13:30 7664-41-7
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 5 of 30
Page 5 of 30
#=AR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
ANALYTICAL RESULTS
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
Sample: EFFLUENT
Lab ID: 70266147002
Parameters
Results
Units
Collected: 08/08/23 11:36 Received: 08/08/23 16:00 Matrix: Water
Report Limit DF
Prepared
Analyzed
CAS No.
Qual
Field Chlorine and pH
Field Temperature Field pH
625.1 MSSV
Acenaphthene Acenaphthylene Anthracene Benzidine Benzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(g,h,i)perylene Benzo(k)fluoranthene 4-Bromophenylphenyl ether Butylbenzylphthalate 4-Chloro-3-methylphenol bis(2-Chloroethoxy)methane bis(2-Chloroethyl) ether 2-Chloronaphthalene 2-Chlorophenol 4-Chlorophenylphenyl ether Chrysene Dibenz(a,h)anthracene 3,3'-Dichlorobenzidine 2,4-Dichlorophenol Diethylphthalate 2,4-Dimethylphenol Dimethylphthalate Di-n-butylphthalate 4,6-Dinitro-2-methylphenol 2,4-Dinitrophenol 2,4-Dinitrotoluene 2,6-Dinitrotoluene Di-n-octylphthalate bis(2-Ethylhexyl)phthalate Fluoranthene Fluorene Hexachloro-1,3-butadiene Hexachlorobenzene Hexachlorocyclopentadiene Hexachloroethane Indeno(1,2,3-cd)pyrene Isophorone Naphthalene Nitrobenzene
Analytical Method: Pace Analytical Services - Melville
25.0
deg C
1
6.94 Std. Units
1
08/08/23 11:36
N3
08/08/23 11:36
N3
Analytical Method: EPA 625.1 Preparation Method: EPA 625.1 SF Pace Analytical Services - Melville
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<4.8
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<4.8
ug/L
<0.96
ug/L
<0.96
ug/L
<4.8
ug/L
<4.8
ug/L
<4.8
ug/L
<4.8
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<4.8
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
0.96 1 08/11/23 22:56 08/14/23 22:42 83-32-9 0.96 1 08/11/23 22:56 08/14/23 22:42 208-96-8 0.96 1 08/11/23 22:56 08/14/23 22:42 120-12-7
4.8 1 08/11/23 22:56 08/14/23 22:42 92-87-5 0.96 1 08/11/23 22:56 08/14/23 22:42 56-55-3 0.96 1 08/11/23 22:56 08/14/23 22:42 50-32-8 0.96 1 08/11/23 22:56 08/14/23 22:42 205-99-2 0.96 1 08/11/23 22:56 08/14/23 22:42 191-24-2 0.96 1 08/11/23 22:56 08/14/23 22:42 207-08-9 0.96 1 08/11/23 22:56 08/14/23 22:42 101-55-3 0.96 1 08/11/23 22:56 08/14/23 22:42 85-68-7 0.96 1 08/11/23 22:56 08/14/23 22:42 59-50-7 0.96 1 08/11/23 22:56 08/14/23 22:42 111-91-1 0.96 1 08/11/23 22:56 08/14/23 22:42 111-44-4 0.96 1 08/11/23 22:56 08/14/23 22:42 91-58-7 0.96 1 08/11/23 22:56 08/14/23 22:42 95-57-8 0.96 1 08/11/23 22:56 08/14/23 22:42 7005-72-3 0.96 1 08/11/23 22:56 08/14/23 22:42 218-01-9 0.96 1 08/11/23 22:56 08/14/23 22:42 53-70-3 0.96 1 08/11/23 22:56 08/14/23 22:42 91-94-1 0.96 1 08/11/23 22:56 08/14/23 22:42 120-83-2 0.96 1 08/11/23 22:56 08/14/23 22:42 84-66-2
4.8 1 08/11/23 22:56 08/14/23 22:42 105-67-9 0.96 1 08/11/23 22:56 08/14/23 22:42 131-11-3 0.96 1 08/11/23 22:56 08/14/23 22:42 84-74-2
4.8 1 08/11/23 22:56 08/14/23 22:42 534-52-1 4.8 1 08/11/23 22:56 08/14/23 22:42 51-28-5 4.8 1 08/11/23 22:56 08/14/23 22:42 121-14-2 4.8 1 08/11/23 22:56 08/14/23 22:42 606-20-2 0.96 1 08/11/23 22:56 08/14/23 22:42 117-84-0 0.96 1 08/11/23 22:56 08/14/23 22:42 117-81-7 0.96 1 08/11/23 22:56 08/14/23 22:42 206-44-0 0.96 1 08/11/23 22:56 08/14/23 22:42 86-73-7 0.96 1 08/11/23 22:56 08/14/23 22:42 87-68-3 0.96 1 08/11/23 22:56 08/14/23 22:42 118-74-1 4.8 1 08/11/23 22:56 08/14/23 22:42 77-47-4 0.96 1 08/11/23 22:56 08/14/23 22:42 67-72-1 0.96 1 08/11/23 22:56 08/14/23 22:42 193-39-5 0.96 1 08/11/23 22:56 08/14/23 22:42 78-59-1 0.96 1 08/11/23 22:56 08/14/23 22:42 91-20-3 0.96 1 08/11/23 22:56 08/14/23 22:42 98-95-3
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 6 of 30
Page 6 of 30
#=AR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
ANALYTICAL RESULTS
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
Sample: EFFLUENT
Lab ID: 70266147002
Parameters
Results
Units
Collected: 08/08/23 11:36 Received: 08/08/23 16:00 Matrix: Water
Report Limit DF
Prepared
Analyzed
CAS No.
625.1 MSSV
2-Nitrophenol 4-Nitrophenol N-Nitrosodimethylamine N-Nitroso-di-n-propylamine N-Nitrosodiphenylamine 2,2'-Oxybis(1-chloropropane) Pentachlorophenol Phenanthrene Phenol Pyrene 1,2,4-Trichlorobenzene 2,4,5-Trichlorophenol 2,4,6-Trichlorophenol Surrogates 2-Fluorophenol (S) Phenol-d5 (S) Nitrobenzene-d5 (S) 2-Fluorobiphenyl (S) 2,4,6-Tribromophenol (S) p-Terphenyl-d14 (S) 1,2-Dichlorobenzene-d4 (S) 2-Chlorophenol-d4 (S)
624.1 Volatile Organics
1,1,1-Trichloroethane 1,1,2,2-Tetrachloroethane 1,1,2-Trichloroethane 1,1-Dichloroethane 1,1-Dichloroethene 1,2-Dichlorobenzene 1,2-Dichloroethane 1,2-Dichloropropane 1,3-Dichlorobenzene 1,4-Dichlorobenzene 2-Chloroethylvinyl ether Acrolein Acrylonitrile Benzene Bromodichloromethane Bromoform Bromomethane Carbon tetrachloride Chlorobenzene Chloroethane Chloroform
Analytical Method: EPA 625.1 Preparation Method: EPA 625.1 SF Pace Analytical Services - Melville
<4.8
ug/L
<9.6
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<4.8
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
<0.96
ug/L
4.8 1 08/11/23 22:56 08/14/23 22:42 88-75-5 9.6 1 08/11/23 22:56 08/14/23 22:42 100-02-7 0.96 1 08/11/23 22:56 08/14/23 22:42 62-75-9 0.96 1 08/11/23 22:56 08/14/23 22:42 621-64-7 0.96 1 08/11/23 22:56 08/14/23 22:42 86-30-6 0.96 1 08/11/23 22:56 08/14/23 22:42 108-60-1 4.8 1 08/11/23 22:56 08/14/23 22:42 87-86-5 0.96 1 08/11/23 22:56 08/14/23 22:42 85-01-8 0.96 1 08/11/23 22:56 08/14/23 22:42 108-95-2 0.96 1 08/11/23 22:56 08/14/23 22:42 129-00-0 0.96 1 08/11/23 22:56 08/14/23 22:42 120-82-1 0.96 1 08/11/23 22:56 08/14/23 22:42 95-95-4 0.96 1 08/11/23 22:56 08/14/23 22:42 88-06-2
34
%
22
%
73
%
72
%
74
%
71
%
61
%
57
%
4-79 1 08/11/23 22:56 08/14/23 22:42 367-12-4 5-55 1 08/11/23 22:56 08/14/23 22:42 4165-62-2 45-110 1 08/11/23 22:56 08/14/23 22:42 4165-60-0 43-114 1 08/11/23 22:56 08/14/23 22:42 321-60-8 23-146 1 08/11/23 22:56 08/14/23 22:42 118-79-6 27-144 1 08/11/23 22:56 08/14/23 22:42 1718-51-0 32-100 1 08/11/23 22:56 08/14/23 22:42 2199-69-1 37-96 1 08/11/23 22:56 08/14/23 22:42 93951-73-6
Analytical Method: EPA 624.1 Pace Analytical Services - Melville
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
3.7
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
34.5
ug/L
1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1
08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02 08/09/23 16:02
71-55-6 79-34-5 79-00-5 75-34-3 75-35-4 95-50-1 107-06-2 78-87-5 541-73-1 106-46-7 110-75-8 107-02-8 107-13-1 71-43-2 75-27-4 75-25-2 74-83-9 56-23-5 108-90-7 75-00-3 67-66-3
Qual
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 7 of 30
Page 7 of 30
#=AR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
ANALYTICAL RESULTS
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
Sample: EFFLUENT
Lab ID: 70266147002
Parameters
Results
Units
Collected: 08/08/23 11:36 Received: 08/08/23 16:00 Matrix: Water
Report Limit DF
Prepared
Analyzed
CAS No.
Qual
624.1 Volatile Organics
Chloromethane Dibromochloromethane Dichlorodifluoromethane Ethylbenzene Methylene Chloride Tetrachloroethene Toluene Trichloroethene Trichlorofluoromethane Vinyl chloride Xylene (Total) cis-1,2-Dichloroethene cis-1,3-Dichloropropene trans-1,2-Dichloroethene trans-1,3-Dichloropropene Surrogates 4-Bromofluorobenzene (S) Toluene-d8 (S) 1,2-Dichloroethane-d4 (S)
4500H+ pH, Electrometric
pH
Temperature, Water (C)
335.4 Cyanide, Total
Cyanide
Analytical Method: EPA 624.1 Pace Analytical Services - Melville
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1
08/09/23 16:02 74-87-3
08/09/23 16:02 124-48-1
08/09/23 16:02 75-71-8
v3
08/09/23 16:02 100-41-4
08/09/23 16:02 75-09-2
08/09/23 16:02 127-18-4
08/09/23 16:02 108-88-3
08/09/23 16:02 79-01-6
08/09/23 16:02 75-69-4
08/09/23 16:02 75-01-4
08/09/23 16:02 1330-20-7
08/09/23 16:02 156-59-2
08/09/23 16:02 10061-01-5
08/09/23 16:02 156-60-5
08/09/23 16:02 10061-02-6
101
%
97
%
91
%
73-122 1 75-122 1 80-120 1
08/09/23 16:02 460-00-4 08/09/23 16:02 2037-26-5 08/09/23 16:02 17060-07-0
Analytical Method: SM22 4500-H+B Pace Analytical Services - Melville
6.8 Std. Units
10.0
deg C
0.10 1 0.10 1
08/17/23 10:31 08/17/23 10:31
H3,H6, N3 H3,H6
Analytical Method: EPA 335.4 Preparation Method: EPA 335.4 Pace Analytical Services - Greensburg
<0.010
mg/L
0.010 1 08/22/23 08:28 08/22/23 11:51 57-12-5
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 8 of 30
Page 8 of 30
#=AR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
ANALYTICAL RESULTS
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
Sample: TRIP BLANK
Lab ID: 70266147003
Parameters
Results
Units
Collected: 08/08/23 00:00 Received: 08/08/23 16:00 Matrix: Water
Report Limit DF
Prepared
Analyzed
CAS No.
Qual
624.1 Volatile Organics
1,1,1-Trichloroethane 1,1,2,2-Tetrachloroethane 1,1,2-Trichloroethane 1,1-Dichloroethane 1,1-Dichloroethene 1,2-Dichlorobenzene 1,2-Dichloroethane 1,2-Dichloropropane 1,3-Dichlorobenzene 1,4-Dichlorobenzene 2-Chloroethylvinyl ether Acrolein Acrylonitrile Benzene Bromodichloromethane Bromoform Bromomethane Carbon tetrachloride Chlorobenzene Chloroethane Chloroform Chloromethane Dibromochloromethane Dichlorodifluoromethane Ethylbenzene Methylene Chloride Tetrachloroethene Toluene Trichloroethene Trichlorofluoromethane Vinyl chloride Xylene (Total) cis-1,2-Dichloroethene cis-1,3-Dichloropropene trans-1,2-Dichloroethene trans-1,3-Dichloropropene Surrogates 4-Bromofluorobenzene (S) Toluene-d8 (S) 1,2-Dichloroethane-d4 (S)
Analytical Method: EPA 624.1 Pace Analytical Services - Melville
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
<1.0
ug/L
1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1 1.0 1
101
%
98
%
92
%
73-122 1 75-122 1 80-120 1
08/09/23 15:39 71-55-6
08/09/23 15:39 79-34-5
08/09/23 15:39 79-00-5
08/09/23 15:39 75-34-3
08/09/23 15:39 75-35-4
08/09/23 15:39 95-50-1
08/09/23 15:39 107-06-2
08/09/23 15:39 78-87-5
08/09/23 15:39 541-73-1
08/09/23 15:39 106-46-7
08/09/23 15:39 110-75-8
08/09/23 15:39 107-02-8
08/09/23 15:39 107-13-1
08/09/23 15:39 71-43-2
08/09/23 15:39 75-27-4
08/09/23 15:39 75-25-2
08/09/23 15:39 74-83-9
08/09/23 15:39 56-23-5
08/09/23 15:39 108-90-7
08/09/23 15:39 75-00-3
08/09/23 15:39 67-66-3
08/09/23 15:39 74-87-3
08/09/23 15:39 124-48-1
08/09/23 15:39 75-71-8
v3
08/09/23 15:39 100-41-4
08/09/23 15:39 75-09-2
08/09/23 15:39 127-18-4
08/09/23 15:39 108-88-3
08/09/23 15:39 79-01-6
08/09/23 15:39 75-69-4
08/09/23 15:39 75-01-4
08/09/23 15:39 1330-20-7
08/09/23 15:39 156-59-2
08/09/23 15:39 10061-01-5
08/09/23 15:39 156-60-5
08/09/23 15:39 10061-02-6
08/09/23 15:39 460-00-4 08/09/23 15:39 2037-26-5 08/09/23 15:39 17060-07-0
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 9 of 30
Page 9 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
QC Batch: QC Batch Method:
315737 EPA 200.7
Associated Lab Samples: 70266147001
METHOD BLANK: 1607022 Associated Lab Samples: 70266147001
Cadmium Chromium Copper Lead Nickel Silver Zinc
Parameter
Units
ug/L ug/L ug/L ug/L ug/L ug/L ug/L
QUALITY CONTROL DATA
Analysis Method: Analysis Description: Laboratory:
EPA 200.7 200.7 Metals, Total Pace Analytical Services - Melville
Matrix: Water
Blank Result
<2.5 <10.0 <25.0
<5.0 <40.0 <10.0 <20.0
Reporting Limit
2.5 10.0 25.0
5.0 40.0 10.0 20.0
Analyzed
08/10/23 13:10 08/10/23 13:10 08/10/23 13:10 08/10/23 13:10 08/10/23 13:10 08/10/23 13:10 08/10/23 13:10
Qualifiers
LABORATORY CONTROL SAMPLE: 1607023
Cadmium Chromium Copper Lead Nickel Silver Zinc
Parameter
Units
ug/L ug/L ug/L ug/L ug/L ug/L ug/L
Spike Conc.
500 500 500 500 500 250 500
LCS Result
496 486 498 508 495 242 503
LCS % Rec
99 97 100 102 99 97 101
% Rec Limits
85-115 85-115 85-115 85-115 85-115 85-115 85-115
Qualifiers
MATRIX SPIKE SAMPLE:
Cadmium Chromium Copper Lead Nickel Silver Zinc
Parameter
1607025
Units
ug/L ug/L ug/L ug/L ug/L ug/L ug/L
70266024006 Result
<2.5 <10.0 <25.0
<5.0 <40.0 <10.0 <20.0
Spike Conc.
500 500 500 500 500 250 500
MS Result
518 505 521 528 493 197 523
MS % Rec
104 101 104 106
98 79 104
% Rec Limits
70-130 70-130 70-130 70-130 70-130 70-130 70-130
Qualifiers
SAMPLE DUPLICATE: 1607024
Cadmium Chromium Copper
Parameter
Units
ug/L ug/L ug/L
70266024006 Result
<2.5 <10.0 <25.0
Dup Result
<2.5 <10.0 <25.0
RPD
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 10 of 30
Page 10 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
SAMPLE DUPLICATE: 1607024
Lead Nickel Silver Zinc
Parameter
Units
ug/L ug/L ug/L ug/L
QUALITY CONTROL DATA
70266024006 Result
<5.0 <40.0 <10.0 <20.0
Dup Result
<5.0 <40.0 <10.0 <20.0
RPD
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 11 of 30
Page 11 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
QC Batch: QC Batch Method:
315676 EPA 624.1
Associated Lab Samples: 70266147002, 70266147003
METHOD BLANK: 1606546 Associated Lab Samples: 70266147002, 70266147003
Parameter
1,1,1-Trichloroethane 1,1,2,2-Tetrachloroethane 1,1,2-Trichloroethane 1,1-Dichloroethane 1,1-Dichloroethene 1,2-Dichlorobenzene 1,2-Dichloroethane 1,2-Dichloropropane 1,3-Dichlorobenzene 1,4-Dichlorobenzene 2-Chloroethylvinyl ether Acrolein Acrylonitrile Benzene Bromodichloromethane Bromoform Bromomethane Carbon tetrachloride Chlorobenzene Chloroethane Chloroform Chloromethane cis-1,2-Dichloroethene cis-1,3-Dichloropropene Dibromochloromethane Dichlorodifluoromethane Ethylbenzene Methylene Chloride Tetrachloroethene Toluene trans-1,2-Dichloroethene trans-1,3-Dichloropropene Trichloroethene Trichlorofluoromethane Vinyl chloride Xylene (Total) 1,2-Dichloroethane-d4 (S) 4-Bromofluorobenzene (S) Toluene-d8 (S)
Units
ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L
% % %
Analysis Method: Analysis Description: Laboratory:
EPA 624.1 624.1 MSV Pace Analytical Services - Melville
Matrix: Water
Blank Result
<1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0
90 100
97
Reporting Limit
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 80-120 73-122 75-122
Analyzed
08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14 08/09/23 12:14
Qualifiers v3
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 12 of 30
Page 12 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
LABORATORY CONTROL SAMPLE: 1606547
Parameter
1,1,1-Trichloroethane 1,1,2,2-Tetrachloroethane 1,1,2-Trichloroethane 1,1-Dichloroethane 1,1-Dichloroethene 1,2-Dichlorobenzene 1,2-Dichloroethane 1,2-Dichloropropane 1,3-Dichlorobenzene 1,4-Dichlorobenzene 2-Chloroethylvinyl ether Acrolein Acrylonitrile Benzene Bromodichloromethane Bromoform Bromomethane Carbon tetrachloride Chlorobenzene Chloroethane Chloroform Chloromethane cis-1,2-Dichloroethene cis-1,3-Dichloropropene Dibromochloromethane Dichlorodifluoromethane Ethylbenzene Methylene Chloride Tetrachloroethene Toluene trans-1,2-Dichloroethene trans-1,3-Dichloropropene Trichloroethene Trichlorofluoromethane Vinyl chloride Xylene (Total) 1,2-Dichloroethane-d4 (S) 4-Bromofluorobenzene (S) Toluene-d8 (S)
Units
ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L
% % %
QUALITY CONTROL DATA
Spike Conc.
20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 60
LCS Result
18.1 17.3 19.3 19.8 18.1 18.8 19.9 19.6 18.6 18.9 21.5 20.4 17.7 19.8 18.3 17.1
9.3 18.2 19.7 19.0 20.0 14.0 20.3 17.7 18.2 10.9 19.6 19.9 16.6 20.0 19.7 17.0 19.4 19.9 17.1 59.1
LCS % Rec
91 87 96 99 91 94 100 98 93 94 107 102 89 99 91 86 47 91 98 95 100 70 102 88 91 54 98 100 83 100 99 85 97 99 85 99 90 103 96
% Rec Limits
Qualifiers
70-130 60-140 70-130 70-130 70-130 65-135 70-130 35-165 70-130 65-135 10-225 60-140 60-140 65-135 65-135 70-130 15-185 IH 70-130 65-135 40-160 70-135 10-205 62-135 25-175 70-135 10-146 v3 60-140 60-140 65-135 70-130 70-130 50-150 65-135 50-150
5-195 73-123 80-120 73-122 75-122
MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 1606706
MS
70266147002 Spike
Parameter
Units
Result Conc.
1,1,1-Trichloroethane
ug/L
<1.0
20
MSD Spike Conc.
1606707
MS Result
20
18.5
MSD Result
17.5
MS % Rec
92
MSD % Rec
88
% Rec Limits
RPD
70-130
5
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Qual
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 13 of 30
Page 13 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 1606706
MS
70266147002 Spike
Parameter
Units
Result Conc.
1,1,2,2-Tetrachloroethane 1,1,2-Trichloroethane 1,1-Dichloroethane 1,1-Dichloroethene 1,2-Dichlorobenzene 1,2-Dichloroethane 1,2-Dichloropropane 1,3-Dichlorobenzene 1,4-Dichlorobenzene 2-Chloroethylvinyl ether Acrolein Acrylonitrile Benzene Bromodichloromethane Bromoform Bromomethane Carbon tetrachloride Chlorobenzene Chloroethane Chloroform Chloromethane cis-1,2-Dichloroethene cis-1,3-Dichloropropene Dibromochloromethane Dichlorodifluoromethane Ethylbenzene Methylene Chloride Tetrachloroethene Toluene trans-1,2-Dichloroethene trans-1,3-Dichloropropene Trichloroethene Trichlorofluoromethane Vinyl chloride Xylene (Total) 1,2-Dichloroethane-d4 (S) 4-Bromofluorobenzene (S) Toluene-d8 (S)
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
3.7
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
34.5
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
20
ug/L
<1.0
60
%
%
%
MSD Spike Conc.
1606707
MS Result
20
17.1
20
19.2
20
19.9
20
17.9
20
18.3
20
19.3
20
18.8
20
18.3
20
18.2
20
18.3
20
21.1
20
17.7
20
19.7
20
21.3
20
15.7
20
4.3
20
18.4
20
19.3
20
17.8
20
53.0
20
10.2
20
20.2
20
16.5
20
17.1
20
7.5
20
19.5
20
21.3
20
16.7
20
20.6
20
22.3
20
15.9
20
19.6
20
18.1
20
14.2
60
59.5
MSD Result
16.5 18.5 18.3 17.3 18.5 18.4 18.1 18.4 18.3 14.6 25.9 16.8 18.9 20.7 15.3
5.1 17.0 18.3 16.5 50.8 10.0 18.9 15.7 16.4
7.1 18.8 20.6 16.4 19.6 20.7 14.6 18.8 17.3 12.9 56.9
MS % Rec
85 96 100 90 92 97 94 92 91 91 106 89 98 88 78 22 92 96 89 93 51 101 83 85 37 98 106 84 103 112 79 98 91 71 99 90 103 96
MSD % Rec
82 93 91 87 92 92 90 92 91 73 129 84 94 85 77 25 85 91 83 81 50 94 78 82 35 94 103 82 98 103 73 94 87 64 95 90 101 96
% Rec Limits
RPD
Qual
60-140 70-130 70-130 70-130 65-135 70-130 35-165 70-130 65-135 10-225 60-140 60-140 65-135 65-135 70-130 15-185 70-130 65-135 40-160 70-135 10-205 62-135 25-175 70-135 10-146 60-140 60-140 65-135 70-130 70-130 50-150 65-135 50-150
5-195 73-123 80-120 73-122 75-122
3 4 9 3 1 5 4 1 0 22 20 6 4 3 2 16 IH 7 5 7 4 2 7 5 4 6 v3 4 3 2 5 8 8 4 5 9 4
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 14 of 30
Page 14 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
QC Batch: QC Batch Method:
316402 EPA 608.3
Associated Lab Samples: 70266147001
METHOD BLANK: 1610595 Associated Lab Samples: 70266147001
Parameter
PCB-1016 (Aroclor 1016) PCB-1221 (Aroclor 1221) PCB-1232 (Aroclor 1232) PCB-1242 (Aroclor 1242) PCB-1248 (Aroclor 1248) PCB-1254 (Aroclor 1254) PCB-1260 (Aroclor 1260) Decachlorobiphenyl (S) Tetrachloro-m-xylene (S)
Units
ug/L ug/L ug/L ug/L ug/L ug/L ug/L
% %
QUALITY CONTROL DATA
Analysis Method: Analysis Description: Laboratory:
EPA 608.3 608.3 GCSV PCB Pace Analytical Services - Melville
Matrix: Water
Blank Result
<1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0
83 79
Reporting Limit
1.0 1.0 1.0 1.0 1.0 1.0 1.0 10-124 10-152
Analyzed
08/16/23 18:49 08/16/23 18:49 08/16/23 18:49 08/16/23 18:49 08/16/23 18:49 08/16/23 18:49 08/16/23 18:49 08/16/23 18:49 08/16/23 18:49
Qualifiers
LABORATORY CONTROL SAMPLE & LCSD: 1610596
Parameter
PCB-1016 (Aroclor 1016) PCB-1260 (Aroclor 1260) Decachlorobiphenyl (S) Tetrachloro-m-xylene (S)
Units
ug/L ug/L
% %
Spike Conc.
5 5
1610597
LCS
LCSD
Result Result
LCS LCSD % Rec % Rec
3.7
3.9 73 78
3.9
3.9 78 78
64 66
74 75
% Rec Limits
50-140 8-140
10-124 10-152
RPD
6 1
Max RPD
30 30 30 30
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 15 of 30
Page 15 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
QC Batch: QC Batch Method:
316401 EPA 608.3
Associated Lab Samples: 70266147001
METHOD BLANK: 1610590 Associated Lab Samples: 70266147001
Parameter
4,4'-DDD 4,4'-DDE 4,4'-DDT Aldrin alpha-BHC beta-BHC Chlordane (Technical) delta-BHC Dieldrin Endosulfan I Endosulfan II Endosulfan sulfate Endrin Endrin aldehyde gamma-BHC (Lindane) Heptachlor Heptachlor epoxide Methoxychlor Mirex Toxaphene Decachlorobiphenyl (S) Tetrachloro-m-xylene (S)
Units
ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L
% %
QUALITY CONTROL DATA
Analysis Method: Analysis Description: Laboratory:
EPA 608.3 608.3 GCSV Pesticides Pace Analytical Services - Melville
Matrix: Water
Blank Result
ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 103 87
Reporting Limit
0.10 0.10 0.10 0.050 0.050 0.050
1.0 0.050
0.10 0.050
0.10 0.10 0.10 0.10 0.050 0.050 0.050 0.50 0.10
5.0 10-124 10-152
Analyzed
08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13 08/16/23 18:13
Qualifiers
LABORATORY CONTROL SAMPLE & LCSD: 1610591
Parameter
4,4'-DDD 4,4'-DDE 4,4'-DDT Aldrin alpha-BHC beta-BHC delta-BHC Dieldrin Endosulfan I Endosulfan II Endosulfan sulfate Endrin Endrin aldehyde
Units
ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L
Spike Conc.
0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4
1610592
LCS
LCSD
Result Result
LCS LCSD % Rec % Rec
0.30
0.28 76 70
0.26
0.25 65 62
0.24
0.20 61 50
0.25
0.24 63 60
0.26
0.25 66 62
0.29
0.27 72 68
0.31
0.29 78 73
0.30
0.28 74 71
0.24
0.23 60 57
0.28
0.27 70 66
0.31
0.30 78 74
0.32
0.30 79 75
0.37
0.36 94 90
% Rec Limits
31-141 30-145 25-160 42-140 37-140 17-147 19-140 36-146 45-153 10-202 26-144 30-147 23-163
RPD
8 4 20 5 6 6 6 5 5 5 5 6 4
Max RPD
30 30 30 30 30 30 30 30 30 30 30 30 30
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Qualifiers
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 16 of 30
Page 16 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
LABORATORY CONTROL SAMPLE & LCSD: 1610591
Parameter
gamma-BHC (Lindane) Heptachlor Heptachlor epoxide Methoxychlor Mirex Decachlorobiphenyl (S) Tetrachloro-m-xylene (S)
Units
ug/L ug/L ug/L ug/L ug/L
% %
Spike Conc.
0.4 0.4 0.4 0.4 0.4
1610592
LCS
LCSD
Result Result
LCS LCSD % Rec % Rec
0.30
0.28 75 71
0.26
0.24 64 60
0.30
0.29 74 72
<0.50 <0.50 74 64
0.20
0.19 51 48
80 76
65 61
% Rec Limits
32-140 34-140 37-142 59-151 40-160 10-124 10-152
RPD 6 7 3
5
Max RPD
30 30 30 30 30 30 30
Qualifiers
LABORATORY CONTROL SAMPLE: 1610593
Parameter
Toxaphene Decachlorobiphenyl (S) Tetrachloro-m-xylene (S)
Units
ug/L % %
Spike Conc.
20
LCS Result
18.6
LCS % Rec
93 102
87
% Rec Limits
41-140 10-124 10-152
Qualifiers
LABORATORY CONTROL SAMPLE: 1610594
Parameter
Chlordane (Technical) Decachlorobiphenyl (S) Tetrachloro-m-xylene (S)
Units
ug/L % %
Spike Conc.
0.1
LCS Result
<1.0
LCS % Rec
151 104
86
% Rec Limits
Qualifiers
30-150 L1 10-124 10-152
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 17 of 30
Page 17 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
QC Batch: QC Batch Method:
316106 EPA 625.1 SF
Associated Lab Samples: 70266147002
METHOD BLANK: 1609131 Associated Lab Samples: 70266147002
Parameter
1,2,4-Trichlorobenzene 2,2'-Oxybis(1-chloropropane) 2,4,5-Trichlorophenol 2,4,6-Trichlorophenol 2,4-Dichlorophenol 2,4-Dimethylphenol 2,4-Dinitrophenol 2,4-Dinitrotoluene 2,6-Dinitrotoluene 2-Chloronaphthalene 2-Chlorophenol 2-Nitrophenol 3,3'-Dichlorobenzidine 4,6-Dinitro-2-methylphenol 4-Bromophenylphenyl ether 4-Chloro-3-methylphenol 4-Chlorophenylphenyl ether 4-Nitrophenol Acenaphthene Acenaphthylene Anthracene Benzidine Benzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(g,h,i)perylene Benzo(k)fluoranthene bis(2-Chloroethoxy)methane bis(2-Chloroethyl) ether bis(2-Ethylhexyl)phthalate Butylbenzylphthalate Chrysene Di-n-butylphthalate Di-n-octylphthalate Dibenz(a,h)anthracene Diethylphthalate Dimethylphthalate Fluoranthene Fluorene Hexachloro-1,3-butadiene
Units
ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L
Analysis Method: Analysis Description: Laboratory:
EPA 625.1 625.1 MSSV Pace Analytical Services - Melville
Matrix: Water
Blank Result
ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND
Reporting Limit
1.0 1.0 1.0 1.0 1.0 5.0 5.0 5.0 5.0 1.0 1.0 5.0 1.0 5.0 1.0 1.0 1.0 10.0 1.0 1.0 1.0 5.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
Analyzed
08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 18 of 30
Page 18 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
METHOD BLANK: 1609131 Associated Lab Samples: 70266147002
Parameter
Hexachlorobenzene Hexachlorocyclopentadiene Hexachloroethane Indeno(1,2,3-cd)pyrene Isophorone N-Nitroso-di-n-propylamine N-Nitrosodimethylamine N-Nitrosodiphenylamine Naphthalene Nitrobenzene Pentachlorophenol Phenanthrene Phenol Pyrene 1,2-Dichlorobenzene-d4 (S) 2,4,6-Tribromophenol (S) 2-Chlorophenol-d4 (S) 2-Fluorobiphenyl (S) 2-Fluorophenol (S) Nitrobenzene-d5 (S) p-Terphenyl-d14 (S) Phenol-d5 (S)
Units
ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L
% % % % % % % %
QUALITY CONTROL DATA
Matrix: Water
Blank Result
ND ND ND ND ND ND ND ND ND ND ND ND ND ND 59 73 65 69 35 75 91 26
Reporting Limit
1.0 5.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 5.0 1.0 1.0 1.0 32-100 23-146 37-96 43-114 4-79 45-110 27-144 5-55
Analyzed
08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02 08/14/23 14:02
Qualifiers
LABORATORY CONTROL SAMPLE & LCSD: 1609132
Parameter
1,2,4-Trichlorobenzene 2,2'-Oxybis(1-chloropropane) 2,4,5-Trichlorophenol 2,4,6-Trichlorophenol 2,4-Dichlorophenol 2,4-Dimethylphenol 2,4-Dinitrophenol 2,4-Dinitrotoluene 2,6-Dinitrotoluene 2-Chloronaphthalene 2-Chlorophenol 2-Nitrophenol 3,3'-Dichlorobenzidine 4,6-Dinitro-2-methylphenol 4-Bromophenylphenyl ether 4-Chloro-3-methylphenol 4-Chlorophenylphenyl ether 4-Nitrophenol
Units
ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L
Spike Conc.
25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25
1609133
LCS
LCSD
Result Result
LCS LCSD % Rec % Rec
17.4
16.6 69 66
19.6
16.7 78 67
22.4
19.9 89 80
19.8
18.8 79 75
18.9
19.2 76 77
14.6
14.9 58 60
26.5
25.5 106 102
23.0
21.8 92 87
20.6
19.8 82 79
20.3
17.6 81 70
16.9
15.7 68 63
18.3
18.7 73 75
24.7
23.9 99 95
26.4
25.8 106 103
21.5
21.0 86 84
20.5
20.0 82 80
22.1
19.8 89 79
10.0 <10.0 40 39
% Rec Limits
57-130 63-139 61-120 52-129 53-122 42-120 10-173 48-127 68-137 65-120 36-120 45-167
8-213 53-130 65-120 41-128 70-130 13-129
RPD
5 16 12
5 1 2 4 6 4 14 7 2 4 2 2 3 11
Max RPD
30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Qualifiers
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 19 of 30
Page 19 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
LABORATORY CONTROL SAMPLE & LCSD: 1609132
Parameter
Acenaphthene Acenaphthylene Anthracene Benzidine Benzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(g,h,i)perylene Benzo(k)fluoranthene bis(2-Chloroethoxy)methane bis(2-Chloroethyl) ether bis(2-Ethylhexyl)phthalate Butylbenzylphthalate Chrysene Di-n-butylphthalate Di-n-octylphthalate Dibenz(a,h)anthracene Diethylphthalate Dimethylphthalate Fluoranthene Fluorene Hexachloro-1,3-butadiene Hexachlorobenzene Hexachlorocyclopentadiene Hexachloroethane Indeno(1,2,3-cd)pyrene Isophorone N-Nitroso-di-n-propylamine N-Nitrosodimethylamine N-Nitrosodiphenylamine Naphthalene Nitrobenzene Pentachlorophenol Phenanthrene Phenol Pyrene 1,2-Dichlorobenzene-d4 (S) 2,4,6-Tribromophenol (S) 2-Chlorophenol-d4 (S) 2-Fluorobiphenyl (S) 2-Fluorophenol (S) Nitrobenzene-d5 (S) p-Terphenyl-d14 (S) Phenol-d5 (S)
Units
ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L ug/L
% % % % % % % %
Spike Conc.
25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25
1609133
LCS
LCSD
Result Result
LCS LCSD % Rec % Rec
20.0
18.7 80 75
22.1
20.1 89 80
23.3
22.5 93 90
26.8
25.9 107 104
22.4
22.2 90 89
23.9
23.4 96 94
21.1
21.2 85 85
24.2
22.8 97 91
21.7
22.2 87 89
18.7
18.8 75 75
17.1
15.4 68 62
22.5
21.4 90 86
21.6
21.0 87 84
22.1
21.6 88 86
23.4
23.4 94 93
22.5
22.8 90 91
25.3
23.9 101 96
22.6
21.0 90 84
22.3
20.4 89 82
23.3
23.6 93 94
23.1
20.7 93 83
17.5
15.7 70 63
22.1
21.9 88 87
11.3
9.6 45 38
17.3
15.1 69 60
23.2
22.5 93 90
19.1
18.6 76 74
18.8
16.8 75 67
11.2
10.5 45 42
23.0
22.0 92 88
18.0
16.7 72 67
19.5
17.3 78 69
20.7
19.3 83 77
23.6
22.2 94 89
8.5
8.4 34 34
21.2
20.2 85 81
70 60
96 90
69 63
81 75
34 30
77 68
85 80
27 27
% Rec Limits
60-132 67-115 43-120 10-194 42-133 32-148 42-140 10-195 25-146 49-165 43-126 29-137 10-140 44-140 8-120 19-132 10-200 10-120 10-120 43-121 70-120 38-120 8-142 10-106 55-120 10-151 47-180 14-198 25-72 68-124 36-120 54-158 38-152 65-120 17-120 70-120 32-100 23-146 37-96 43-114
4-79 45-110 27-144
5-55
RPD
7 10
3 3 1 2 0 6 2 1 10 5 3 2 0 1 6 7 9 1 11 11 1 16 13 3 3 11 6 4 7 12 7 6 1 5
Max RPD
Qualifiers
30 30 30 30 v1 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 20 of 30
Page 20 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
QC Batch: QC Batch Method:
315938 SM22 3500-Cr B
Associated Lab Samples: 70266147001
METHOD BLANK: 1608147 Associated Lab Samples: 70266147001
Parameter Chromium, Hexavalent
Units mg/L
LABORATORY CONTROL SAMPLE: 1608148
Parameter Chromium, Hexavalent
Units mg/L
MATRIX SPIKE SAMPLE:
Parameter Chromium, Hexavalent
1608149
Units mg/L
SAMPLE DUPLICATE: 1608150
Parameter Chromium, Hexavalent
Units mg/L
QUALITY CONTROL DATA
Analysis Method: Analysis Description: Laboratory:
SM22 3500-Cr B Chromium, Hexavalent by 3500 Pace Analytical Services - Melville
Matrix: Water
Blank Result
<0.020
Reporting Limit
0.020
Analyzed 08/11/23 00:40
Qualifiers
Spike Conc.
0.2
LCS Result
0.20
LCS % Rec
98
% Rec Limits
85-115
Qualifiers
70265372022 Result
<0.020
Spike Conc.
0.2
MS Result
0.20
MS % Rec
98
% Rec Limits
Qualifiers
75-125 H3
70265372022 Result
<0.020
Dup Result
<0.020
RPD
Qualifiers H3
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 21 of 30
Page 21 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
QC Batch: QC Batch Method:
316718 SM22 4500-H+B
Associated Lab Samples: 70266147002
SAMPLE DUPLICATE: 1612298
Parameter
pH Temperature, Water (C)
Units
Std. Units deg C
QUALITY CONTROL DATA
Analysis Method: Analysis Description: Laboratory:
SM22 4500-H+B 4500H+B pH Pace Analytical Services - Melville
70265582001 Result
7.5 7.2
Dup Result
7.6 7.6
RPD
Qualifiers
0 H3,H6,N3 5 H3,H6
SAMPLE DUPLICATE: 1612299
Parameter pH Temperature, Water (C)
Units
Std. Units deg C
70266798004 Result
7.0 6.5
Dup Result
7.0 6.5
RPD
Qualifiers
1 H3,H6,N3 0 H3,H6
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 22 of 30
Page 22 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
QC Batch: QC Batch Method:
316844 EPA 300.0
Associated Lab Samples: 70266147001
METHOD BLANK: 1613045 Associated Lab Samples: 70266147001
Fluoride
Parameter
Units mg/L
LABORATORY CONTROL SAMPLE: 1613046
Fluoride
Parameter
Units mg/L
MATRIX SPIKE SAMPLE:
Fluoride
Parameter
1613048
Units mg/L
MATRIX SPIKE SAMPLE:
Fluoride
Parameter
1613050
Units mg/L
SAMPLE DUPLICATE: 1613049
Fluoride
Parameter
Units mg/L
SAMPLE DUPLICATE: 1613051
Fluoride
Parameter
Units mg/L
QUALITY CONTROL DATA
Analysis Method: Analysis Description: Laboratory:
EPA 300.0 300.0 IC Anions Pace Analytical Services - Melville
Matrix: Water
Blank Result
<0.10
Reporting Limit
0.10
Analyzed 08/18/23 22:43
Qualifiers
Spike Conc.
1
LCS Result
1.0
LCS % Rec
102
% Rec Limits
90-110
Qualifiers
70265613001 Result
<0.10
Spike Conc.
1
MS Result
0.94
MS % Rec
93
% Rec Limits
90-110
Qualifiers
70266798004 Result
<0.10
Spike Conc.
1
MS Result
0.89
MS % Rec
87
% Rec Limits
Qualifiers
90-110 M1
70265613001 Result
<0.10
Dup Result
<0.10
RPD
Qualifiers
70266798004 Result
<0.10
Dup Result
<0.10
RPD
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 23 of 30
Page 23 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
QC Batch: QC Batch Method:
610176 EPA 335.4
Associated Lab Samples: 70266147002
METHOD BLANK: 2969629 Associated Lab Samples: 70266147002
Cyanide
Parameter
Units mg/L
QUALITY CONTROL DATA
Analysis Method: Analysis Description: Laboratory:
EPA 335.4 335.4 Cyanide, Total Pace Analytical Services - Greensburg
Matrix: Water
Blank Result
<0.010
Reporting Limit
0.010
Analyzed 08/22/23 11:44
Qualifiers
METHOD BLANK: 2969631 Associated Lab Samples: 70266147002
Cyanide
Parameter
Units mg/L
Matrix: Water
Blank Result
<0.010
Reporting Limit
0.010
Analyzed 08/22/23 11:50
Qualifiers 1j
LABORATORY CONTROL SAMPLE: 2969630
Cyanide
Parameter
Units mg/L
Spike Conc.
0.2
LCS Result
0.21
LCS % Rec
103
% Rec Limits
90-110
Qualifiers
MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2969632
MS
30612666001 Spike
Parameter
Units
Result Conc.
Cyanide
mg/L 0.0069J
0.1
MSD Spike Conc.
2969633
MS Result
0.1 0.094
MSD Result
0.098
MS % Rec
88
MSD % Rec
91
% Rec Limits
RPD
Qual
90-110
3 ML
MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2969634
MS
30613517006 Spike
Parameter
Units
Result Conc.
Cyanide
mg/L
ND
0.1
MSD Spike Conc.
2969635
MS Result
0.1
0.11
MSD Result
0.11
MS % Rec
101
MSD % Rec
103
% Rec Limits
RPD
90-110
2
Qual
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 24 of 30
Page 24 of 30
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
QC Batch: QC Batch Method:
316148 EPA 350.1
Associated Lab Samples: 70266147001
METHOD BLANK: 1609366 Associated Lab Samples: 70266147001
Parameter Nitrogen, Ammonia
Units mg/L
LABORATORY CONTROL SAMPLE: 1609367
Parameter Nitrogen, Ammonia
Units mg/L
MATRIX SPIKE SAMPLE:
Parameter Nitrogen, Ammonia
1609368
Units mg/L
MATRIX SPIKE SAMPLE:
Parameter Nitrogen, Ammonia
1609370
Units mg/L
SAMPLE DUPLICATE: 1609369
Parameter Nitrogen, Ammonia
Units mg/L
SAMPLE DUPLICATE: 1609371
Parameter Nitrogen, Ammonia
Units mg/L
QUALITY CONTROL DATA
Analysis Method: Analysis Description: Laboratory:
EPA 350.1 350.1 Ammonia Pace Analytical Services - Melville
Matrix: Water
Blank Result
ND
Reporting Limit
0.10
Analyzed 08/13/23 13:15
Qualifiers
Spike Conc.
1
LCS Result
0.91
LCS % Rec
91
% Rec Limits
90-110
Qualifiers
70266163001 Result
17.4
Spike Conc.
10
MS Result
27.8
MS % Rec
105
% Rec Limits
90-110
Qualifiers
70266332006 Result
15.1
Spike Conc.
10
MS Result
25.8
MS % Rec
107
% Rec Limits
90-110
Qualifiers
70266163001 Result
17.4
Dup Result
16.0
RPD
Qualifiers
8
70266332006 Result
15.1
Dup Result
14.2
RPD
Qualifiers
7
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 25 of 30
Page 25 of 30
#=QL#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALIFIERS
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
DEFINITIONS
DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot.
ND - Not Detected at or above adjusted reporting limit.
TNTC - Too Numerous To Count
J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit.
MDL - Adjusted Method Detection Limit.
PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values.
LCS(D) - Laboratory Control Sample (Duplicate)
MS(D) - Matrix Spike (Duplicate)
DUP - Sample Duplicate
RPD - Relative Percent Difference
NC - Not Calculable.
SG - Silica Gel - Clean-Up
U - Indicates the compound was analyzed for, but not detected. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes.
TNI - The NELAC Institute.
ANALYTE QUALIFIERS
1j
pH was adjusted to >12 from unpreserved bottle at bench
H1
Analysis conducted outside the EPA method holding time.
H3
Sample was received or analysis requested beyond the recognized method holding time.
H6
Analysis initiated outside of the 15 minute EPA recommended holding time.
IH
This analyte exceeded secondary source verification criteria high for the initial calibration. The reported results should be
considered an estimated value.
L1
Analyte recovery in the laboratory control sample (LCS) was above QC limits. Results for this analyte in associated
samples may be biased high.
M1
Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.
ML
Matrix spike recovery and/or matrix spike duplicate recovery was below laboratory control limits. Result may be biased
low.
N3
Accreditation is not offered by the relevant laboratory accrediting body for this parameter.
v1
The continuing calibration verification was above the method acceptance limit. Any detection for the analyte in the
associated samples may have a high bias.
v3
The continuing calibration verification was below the method acceptance limit. Any detection for the analyte in the
associated samples may have a low bias.
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 26 of 30
Page 26 of 30
#=CR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA CROSS REFERENCE TABLE
Project: Pace Project No.:
SEMI ANNUAL 8/8 70266147
Lab ID 70266147002 70266147001 70266147001 70266147001 70266147002 70266147002 70266147003 70266147001 70266147002 70266147001 70266147002 70266147001
Sample ID EFFLUENT EFFLUENT EFFLUENT EFFLUENT EFFLUENT EFFLUENT TRIP BLANK EFFLUENT EFFLUENT EFFLUENT EFFLUENT EFFLUENT
QC Batch Method
EPA 608.3 EPA 608.3 EPA 200.7 EPA 625.1 SF EPA 624.1 EPA 624.1 SM22 3500-Cr B SM22 4500-H+B EPA 300.0 EPA 335.4 EPA 350.1
QC Batch 315921 316402 316401 315737 316106 315676 315676 315938 316718 316844 610176 316148
Analytical Method EPA 608.3 EPA 608.3 EPA 200.7 EPA 625.1
EPA 335.4
Analytical Batch 316515 316511 315800 316118
610216
Date: 08/30/2023 04:15 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 4 Page 27 of 30
Page 27 of 30
Attachment 4 Page 28 of 30
Page 28 of 30
Attachment 4 Page 29 of 30
Page 29 of 30
Attachment 4 Page 30 of 30
Page 30 of 30
Attachment 05 Garnet Waste Determination
Form No.: Last Reviewed Date: Revision No.: Coxsackie, New York
F-00663 Hazardous Waste Determination Worksheet -
10/17/2023 A
Authorized By: WI-00216 Environmental Management System - Requirements
Page 1 of 2
DCO Site:
Coxsackie 171 Stacey Road Coxsackie, NY 12051-2613
EPA ID:
NYR 000 219 550
Date:
6/14/2024
By:
Mary McCoy
Waste Stream Common Name:
Spent Garnet
Check one: RCRA Haz Waste
Non-RCRA Haz Waste
Not Haz Waste
RCRA Waste Codes:
NA
State Waste Codes:
NA
0
Source Code:
#N/A
Form Code:
#N/A
Management Method:
#N/A
(For California sites, if this waste is subject to 22 CCR 66266.1 and is not recycled, attach justification.)
UN#, Proper Shipping Name, Hazard Class, Packing Group: NA
ERG:
NA
Check one: Ongoing
RQ Threshold:
NA
Intermittent
One-time
Other information: Spent garnet is not a RCRA hazardous waste. 2018 TCLP analytical results for chromium was below detection limits (see attached). Generator knowledge analysis of operations indicates that material is non-hazardous. The waterjet operations utilizes 200,000+ pounds of garnet every year. The non-hazardous portion of the waste streams is quite significant.
Waste generation process (listed, characteristic); chemicals used; location within facility: Waterjet operations
Attachment 5 Page 1 of 8
#=CL#
LIMS USE: FR - STEVE CZARNECKI LIMS OBJECT ID: 7071555
November 29, 2018
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 (631)694-3040
Steve Czarnecki Ducommun Aerostructures 171 Stacy Road Coxsackie, NY 12051
RE: Project: CHROME 11/19 Pace Project No.: 7071555
Dear Steve Czarnecki: Enclosed are the analytical results for sample(s) received by the laboratory on November 20, 2018. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNI/NELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report.
If you have any questions concerning this report, please feel free to contact me.
Sincerely,
John D. Stanton john.stanton@pacelabs.com (631)694-3040 Project Manager
Enclosures
cc: Eugenia Lighthouse, Ducommun Incorporated
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 5 Page 2 of 8
Page 1 of 7
#=CP#
Project: Pace Project No.:
CHROME 11/19 7071555
Long Island Certification IDs 575 Broad Hollow Rd, Melville, NY 11747 New York Certification #: 10478 Primary Accrediting Body New Jersey Certification #: NY158 Pennsylvania Certification #: 68-00350 Connecticut Certification #: PH-0435
CERTIFICATIONS
Maryland Certification #: 208 Rhode Island Certification #: LAO00340 Massachusetts Certification #: M-NY026 New Hampshire Certification #: 2987
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 (631)694-3040
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 5 Page 3 of 8
Page 2 of 7
#=AR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 (631)694-3040
ANALYTICAL RESULTS
Project: Pace Project No.:
CHROME 11/19 7071555
Sample: USED GARNET
Lab ID: 7071555001 Collected: 11/19/18 10:35 Received: 11/20/18 09:45
Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions.
Matrix: Solid
Parameters
Results
Units
Report Limit DF
Prepared
Analyzed
CAS No.
6010 MET ICP, TCLP Chromium
Analytical Method: EPA 6010C Preparation Method: EPA 3005A Leachate Method/Date: EPA 1311; 11/27/18 22:35
<0.50
mg/L
0.50 1 11/29/18 08:01 11/29/18 13:44 7440-47-3
Qual
Date: 11/29/2018 02:46 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 5 Page 4 of 8
Page 3 of 7
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 (631)694-3040
Project: Pace Project No.:
CHROME 11/19 7071555
QC Batch:
92948
QC Batch Method: EPA 3005A
Associated Lab Samples: 7071555001
METHOD BLANK: 429089 Associated Lab Samples: 7071555001
Chromium
Parameter
Units mg/L
LABORATORY CONTROL SAMPLE: 429090
Chromium
Parameter
Units mg/L
MATRIX SPIKE SAMPLE:
Chromium
Parameter
429092
Units mg/L
SAMPLE DUPLICATE: 429091
Chromium
Parameter
Units mg/L
QUALITY CONTROL DATA
Analysis Method: Analysis Description:
EPA 6010C 6010 MET TCLP
Matrix: Water
Blank Result
<0.50
Reporting Limit
0.50
Analyzed 11/29/18 13:42
Qualifiers
Spike Conc.
.25
LCS Result
<0.50
LCS % Rec
85
% Rec Limits
80-120
Qualifiers
7071555001 Result
<0.50
Spike Conc.
.25
MS Result
<0.50
MS % Rec
90
% Rec Limits
75-125
Qualifiers
7071555001 Result
<0.50
Dup Result
<0.50
RPD
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 11/29/2018 02:46 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 5 Page 5 of 8
Page 4 of 7
#=QL#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 (631)694-3040
QUALIFIERS
Project: Pace Project No.:
CHROME 11/19 7071555
DEFINITIONS
DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute.
Date: 11/29/2018 02:46 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 5 Page 6 of 8
Page 5 of 7
#=CR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 (631)694-3040
QUALITY CONTROL DATA CROSS REFERENCE TABLE
Project: Pace Project No.:
CHROME 11/19 7071555
Lab ID 7071555001
Sample ID USED GARNET
QC Batch Method EPA 3005A
QC Batch 92948
Analytical Method EPA 6010C
Analytical Batch
92950
Date: 11/29/2018 02:46 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.
Attachment 5 Page 7 of 8
Page 6 of 7
Attachment 5 Page 8 of 8
Page 7 of 7
Attachment 06 Facility Follow up Email to EPA
McCoy, Mary
From: Sent: To: Cc: Subject: Attachments:
McCoy, Mary Tuesday, June 18, 2024 12:37 PM Vince Damiano Dumaua, Pedro; Gutierrez, Jennette; Hasenkopf, Robert RE: Follow-up From EPA Visit on 6/12 Manifest Bonderite.JPG; Profiles Lab Results.zip; ER services Corres.zip; Manifests TSDF copies.zip; POTW corres - no permit.pdf; Debris pictures.zip; F-00713 Daily Waste Shed Inspection Form - EMS Rev A.xlsx
Hi Vince,
Here are the documents that I owe you:
Contingency plan - this is huge, so I will overnight a thumb drive to you. Although I'm willing to try, it will be likely because of security that I won't be able to upload to an FTP site. Is your address 14555 Avion Pkwy #200, Chantilly, VA 20151?
Correspondence regarding emergency services to visit facility and become familiar with layout o See "ER services Corres.zip"
Signed manifests with the following manifest numbers: 002353387 VES 002353236 VES 002353002 VES 002236882 VES 002236763 VES 001914991 VES
o See Manifests for TSDF copies Correspondence from POTW stating you do not qualify for a disposal permit
o See POTW corres - no permit.pdf Waste determination
Waste determination on spent garnet from water jets Waste determination on material accumulating in UST Waste determination (2023 results) on water being sent to POTW o See "Profiles Lab Results.zip"
Follow up to your comments while you were here onsite:
The 5-gallon container of hazardous waste with the accumulation date of September 2023 was shipped offsite on today, 6/18/24. It was placed in an area normally obscured by a 300-gallon intermediate bulk container, which is why the 5-gallon container was not seen during weekly inspections. We have created a small container area in the LT-90 to prevent this in the future. See Manifest Bonderite.
To address the open and undated containers, we started daily inspections of the LT-90 to make following up on deficiencies easier and more timely. See attached inspection form. This form is not the same as the weekly inspection form, which is more comprehensive.
The acetone debris and paint containers are now labeled and closed. See attached photographs. Regarding the expired paint in the cabinet, although expired paint cannot be used in production, which
is why they're segregated, they still can be used on occasion for training, troubleshooting, etc.; hence, paint in that cabinet is not a waste.
I don't see where containers of universal waste aerosol cans must be closed. See the attached fact sheet, which can be found here: https://dec.ny.gov/environmental-protection/wastemanagement/hazardous-waste/universal-waste
1
Attachment 6 Page 1 of 3
The adhesive/sealant waste that did not have an accumulation date was not a RCRA hazardous waste - see attached waste determination. That material was pending determination, and the lab issued the final report on June 12, 2024.
M
Mary A. McCoy, PE 203.300.7303 cell
Safety Sugges ons: EHSSupportNY@ducommun.com
From: McCoy, Mary Sent: Friday, June 14, 2024 11:07 AM To: Vince Damiano <Vince.Damiano@erg.com> Subject: RE: Follow-up From EPA Visit on 6/12
Hi Vince,
It was nice to meet you.
I'll have something for you shortly.
M
Mary A. McCoy, PE 203.300.7303 cell
Safety Sugges ons: EHSSupportNY@ducommun.com
From: Vince Damiano <Vince.Damiano@erg.com> Sent: Wednesday, June 12, 2024 3:58 PM To: McCoy, Mary <MMcCoy@ducommun.com>; Howe, Millage <MHowe@ducommun.com>; sshelhammer@ducommun.com; Hasenkopf, Robert <RHasenkopf@ducommun.com> Subject: Follow-up From EPA Visit on 6/12
Hello All, I am following up with a list of items requested from our inspection today. Contingency plan Correspondence regarding emergency services to visit facility and become familiar with layout Signed manifests with the following manifest ZjQcmQRYFpfptBannerStart
This Message Is From an External Sender
This message came from outside your organization.
ZjQcmQRYFpfptBannerEnd
Hello All,
I am following up with a list of items requested from our inspection today.
Contingency plan Correspondence regarding emergency services to visit facility and become familiar with layout Signed manifests with the following manifest numbers:
o 002353387 VES o 002353236 VES o 002353002 VES o 002236882 VES o 002236763 VES o 001914991 VES
2 Attachment 6 Page 2 of 3
Correspondence from POTW stating you do not qualify for a disposal permit Waste determination on spent garnet from water jets Waste determination on material accumulating in UST Waste determination (2023 results) on water being sent to POTW Again, thank you for taking the time out of your day to meet with me. Please let me know if you have any questions or concerns. Any follow-up can be sent to myself or uploaded to the secure FTP site which I will share with you shortly. Thanks, Vince
Vince Damiano
Chemical Engineer, Chantilly Office Cell: (570) 956-1468 Vince.Damiano@erg.com
3 Attachment 6 Page 3 of 3
Attachment 07 Facility Follow-up Photographs
Shipping manifest for 5-gallon container of hazardous waste with the accumulation date of September 2023 was shipped off site 6/18/24
Attachment 7 Page 1 of 3
Acetone debris tote closed and dated as of 6/18/2024
Attachment 7 Page 2 of 3
Paint debris tote closed and dated as of 6/18/2024
Attachment 7 Page 3 of 3
Attachment 08 RCRA Contingency Plan
WI-00237 RCRA Contingency Plan
Ducommun AeroStructures New York Coxsackie, NY
Appendix 7.1 - Emergency Contact Information (F-00639)
Appendix 2.1 - Immediate Emergency Procedures
RCRA Contingency Plan
Appendix 3.c)i) - High Hazard Chemical Incidental Spill Response Procedure (WI-00241 )
Appendix 2-4)b)iii) - Start of Fire Pump (WI-00250)
Appendix 2.4 - Utility Shutoffs (WI-00240)
Appendix 3.1 - Emergency Equipment (F-00637)
Appendix 4.1.5.1 - Chemical Line Tank Concentrations
Appendix 7.3 - Supporting Personnel
I I
10
I
11
'
Appendix 2-1)a) - Shelter In Place (Tornado) (WI-00242) Appendix 2-1)b) - Medical Emergency (WI-00251)
Appendix 9.4.4.2 - Agreement with Veolia
Appendix 4.2 - Safety Data Sheets
6 0300 '
Coxsackie, New York
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Last Reviewed Date: 2/1/2024 Revision No.: D
Title Page
Page: 31 of 33
RCRA Contingency Plan
Ducommun AeroStructures New York Coxsackie, NY
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 12 of 33
Map - 2' x 3' to be posted at the front of the plan
A EXPANDED LOT C, ADDED LOT D
B AREAS 13 AND 14 ADDED EMERGENCY EVACUATION C LAYOUT UPDATE TO INCLUDE ADDED VS5
9/27/2016 10/4/2016 07/29/19
RMP RMP ML
Muster Point 2 EXIT
*VS4 Passivation/Alodine Line
w/ spill kit
PARKING LOT D
EXIT
1
DROPHAMMER
EXIT
1
EXIT
Receiving Door Blank Cell
*RCRA
hazarous
waste storage
area LT-90
EXIT
6 1
*Raw
chemical
storage
VS3 Cleaning Line
w/ spill kit
EXIT
High Risk Spill Kit
pH Lab
4
RECEIVING
1
SHIPPING
WOMENS
1
MENS
BREAK ROOM
2
45
VS4 WELD ASSEMBLY
1
VS4 GENERAL ASSEMBLY
A.P.E. LINE
2 4
VS4 WELD ASSEMBLY
1
VS4 MFG OFFICE
VS3 MFG OFFICE
PAINT
VS3 ASSEMBLY
VS2 ASSEMBLY
5
VS3 CLEAN LINE
4
1 LAB
1
QUALITY CLINIC
NDT VS2 MFG OFFICE
1
1
VS2 FABRICATION
1 VS1 ASSEMBLY
BOX BUILD AREA SHOP PATTERN
VS1 MFG/ENG OFFICE
EXIT
EXIT
High Risk Spill Kit
PARKING LOT A
1
VS4 FABRICATION
1
1 1 Spill Kit (oil)
1 2
2 VS3 FABRICATION 1
1
1
4
5
EXIT
1 5
BLANKING
1
VS5 CLEAN LINE
VS5 FABRICATION
PAINT
1 1
VS2 FABRICATION
MSDS 4
1 VS1 FABRICATION
5 VS1 CLEAN LINE
7
1
1
MAINT.
COMPRESSOR ROOM
2
ROOM 1
1
EXIT
VS5 FABRICATION
EH&S
DCC
1
1 1
1
FILE ROOM
MENS IPT 7
CONF
ROOM
WOMENS MENS
"OAKWOOD" CONF ROOM
4 31
1 1
1
CAFETERIA
RECEPTION
1
1
"WELCOME"
CONF ROOM
GM
OFFICE
*VS1 Cleaning Line
w/ spill kit
EXIT
PARKING LOT B
EXIT
Spill Kit
*VS5 Cleaning Line
w/ spill kit
PARKING LOT C
KEY
1
FIRE EXTINGUISHER, ABC
2
FIRE EXTINGUISHER, CLASS D
3
AED
4
FIRST AID
5
EYE WASH STATION
6
EMERGENCY PHONE
7
SHELTER IN PLACE AREA
8
EMERGENCY EVACUATION AREA
9
CHEMICAL STORAGE AREAS
10
Catch Basins
Muster Point 1
F-00646 Site Safety Map - EMS Authorized by: WI-00237 RCRA Contingency Plan - EMS
Last Reviewed Date: 10/24/23
Rev A
Front view Scale: 1:400
Hot ovens/presses >1000F in western half of the building
DAS ENGINEERING DRAWING
AeroStructures-New York
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 26 of 33
Appendix 7.1 - Emergency Contact Information (F-00639) - to be posted at the front of the plan
Coxsackie, New York Last Reviewed Date: 3/25/24
UNIVERSAL EMERGENCY NUMBER
Form No.: F-00639 Emergency Response Contact Information
Authorized by: WI-006216 RCRA Contingency Plan
Revision No.: B
Page: 1 of 3
Facility Phone: 9911
Cell Phone: 911
EMERGENCY COORDINATORS
MAINTENANCE LEAD
Primary
First Alternate
Second Alternate
Sunder Shelhamer
Mary McCoy
Millage Howe
Paul Bradt
CELL: (518) 935-
CELL: (203) 300-7303
CELL: (518) 764-8278 CELL: (518) 944-7956 7023
Alt cell: (860) 578-4008
Alt cell: (979) 221-8885
Third Alternate
Fourth Alternate
George Johnson
Rob Moore
CELL: (848) 888-2291 CELL: (518) 755-0227
EMERGENCY RESPONSE ORGANIZATIONS (NON-EMERGENCY NUMBERS - CALL 911 FOR EMERGENCIES)
Primary Fire Department & Spill Village of Coxsackie Fire Department Fire Chief-Shawn Burdick firechief@villageofcoxsackie.com (518) 242-0032
Fire Department Earlton Fire House 1561 New York 81 Earlton, NY 12058 (518) 731-6683
Ambulance Town of Coxsackie Ambulance Nadine Erceg-Myrdycz, Chief of EMS (518) 731-3687 emschief@coxsackie.org
Hospital Columbia Memorial Hospital 71 Prospect Ave Hudson, NY 12534 (518) 828-7601
Law Enforcement New York State Police Troop F Zone 1 Coxsackie Station c/o SP Catskill South Cairo, NY 12482 (518) 731-2333 Poison Control 800-222-1222
Law Enforcement Greene County Sheriffs Office 45 Haverly Mem Dr Coxsackie, NY 12051 (518) 943-3300
Urgent Care EmUrgentCare 11835 State Rt. 9W West Coxsackie, NY 12192 (518) 731-9000
Spill Veolia 9+1-800-354-2382 Dial "1"
Hospital St. Peter's Hospital 315 South Manning Blvd., Albany, NY 518-525-1550
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York Last Reviewed Date: 3/25/24
Form No.: F-00639 Emergency Response Contact Information
Authorized by: WI-006216 RCRA Contingency Plan
Revision No.: B
Page: 2 of 3
OTHER ORGANIZATIONS
NYDEC Spill Hotline
National Response OSHA - (800) 321-6742
800-457-7362
Center (use their 24-
hour toll free number
9+800-424-8802)
Central Hudson
(For electrical and outages)
(845) 452-2700
FIRST AID RESPONDERS - USE THE PA SYSTEM - "CODE 3 [VALUE STREAM AND AREA]"
Natural Gas Central Hudson Gas & Electric 800-942-8274
Name
Phone
Shift
Name
Phone
Shift Name
Phone Shift
Mary McCoy
4650
1
Curt Abretske
Page
2 Jessica Sturner
Page
3
Philip Moritz
Page
1
George Johnson Page
2 Charlie Buccino Page
3
Maximus Kelly
Page
1
Lindsay Wexler Page
2 Robert Moore
Page
3
Joseph McGiffert Page
1
Josh Benoit
Page
2
Orland Perkins
Page
1
Travis Knott
Page
2
DUCOMMUN HAZMAT TEAM - USE THE PA SYSTEM - "HAZMAT [VALUE STREAM AND AREA]"
Name
Phone
Shift
Name
Phone
Shift Name
Mike Hogan
Page
1
George Johnson Page
2 Jessica Sturner
Kris Hogan
Page
1
Curt Abretske
Page
2 Charlie Buccino
Mike Czyzewski Page
1
Travis Knott
Page
2
Mary McCoy
4650
1
Phone Shift
Page
3
Page
3
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Form No.: F-00639 Emergency Response Contact Information
Authorized by: WI-006216 RCRA Contingency Plan
Coxsackie, New York Last Reviewed Date: 3/25/24
Revision No.: B
Page: 3 of 3
Posting for RCRA hazardous waste storage area phone
IN CASE OF AN EMERGENCY, 9911 AND notify the following personnel:
EMERGENCY COORDINATORS
MAINTENANCE LEAD
Primary Mary McCoy CELL: (203) 300-7303 Alt cell: (860) 578-4008 Alt cell: (979) 221-8885
First Alternate Millage Howe CELL: (518) 764-8278
Second Alternate Paul Bradt CELL: (518) 944-7956
Third Alternate George Johnson CELL: (848) 888-2291
Fourth Alternate Rob Moore CELL: (518) 755-0227
Sunder Shelhamer CELL: (518) 9357023
OUTSIDE EMERGENCY PERSONNEL TO BE NOTIFIED, IF REQUIRED:
[Coxsackie] Police Department
9+911
[State] Police Information Desk
9+(518)-622-8600
[Coxsackie] Fire Department
9+(518) 731-6510
For a spill inside the facility, the Emergency Coordinator or designee should call Veolia 9+1-800-3542382 Dial "1".
If the Person-in-Charge determines that the facility has had a release, fire, or explosion which could threaten human health, or the environment, outside the facility, they must:
1. If the assessment indicates that evacuation of local areas may be advisable, immediately notify appropriate local authorities (9+911).
2. Notify:
2.1 Veolia 9+1-800-354-2382 Dial "1"
2.2 NYSDEC 9+ 1-800-457-7362
2.3 National Response Center (use their 24-hour toll free number 9+800-424-8802).
The reports made for these incidents shall include the following:
Your name and telephone number
Name and address of the facility:
Time and type of incident (for example, release, fire);
Name and quantity of material(s) involved, to the extent known:
The extent of injuries, if any; and
The possible hazards to human health, or the environment, outside the facility.
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 13 of 33
Appendix 2.1 - Immediate Emergency Procedures - to be posted at the front of the plan
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Coxsackie, New York
Last Reviewed Date: 2/1/24
Revision No.: D
Page: 14 of 33
1) For Shelter in Place (tornado) or Medical Emergency, go to Appendices 2-1)a) and 2-1)b) In the event of a fire, explosion or spill at the facility, personnel will execute the following steps: 2) Discovering personnel will:
a) Tell a supervisor or manager immediately b) If they deem the situation dangerous enough, personnel are empowered to:
i) Initiate evacuation of the facility. See Section 4)e) of this section. ii) Call 9-911 3) All team leads, supervisors, managers and emergency coordinators1 must: a) Assess emergency situations b) If there is sufficient immediate threat to human health and the environment i) Initiate evacuation of the facility. See Section 4)e) of this section. ii) Call 9-911 c) Immediately notify the emergency coordinator or designee who will implement the Contingency Plan in the following situations: i) Any spill of the materials listed in Section 4)c)i) of this section ii) A fire that cannot be extinguished with one extinguisher iii) Any explosion iv) Any other situation involving a RCRA hazard waste that poses a threat to human health or the
environment 4) The Emergency Coordinator or designee will:
a) Injuries i) Summon trained personnel to render first aid ii) Call 9-911 and summon EMS for more severe injuries
b) Explosions and fires that cannot be extinguished with one attempt: i) Initiate evacuation. See Section e) of this section ii) Summon the fire department iii) Verify that Maintenance personnel will start the operation of the fire pump. The instructions on how to turn on the Fire Pump is posted at the Fire Pump House. See Appendix 2-4)b)iii)
1 See Section 7 of the main body of the Contingency Plan on page 6
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Coxsackie, New York
Last Reviewed Date: 2/1/24
Revision No.: D
Page: 15 of 33
iv) Inform the fire department that: (1) There are ovens and presses at temperatures greater than 1000F in the western half of the building (2) A water reactive material, Molten Salt Bath also known as "Caustic" and "ALKO-N", which is a potassium-based material, is located in the chemical lines at VS 1, 3 and 5. (3) There are chemical and waste storage sheds on the east side of the building by the back gate (4) There are drums of flammable liquids [acetone (99% - 100%), IPA (99%), and waste paint] in the Paint areas, next to VS4 Passivation/Alodine Line, and near Receiving Door #5 at Blank Cell.
c) Spills i) If more than 2.5 gallons of these material has spilled, contact the Fire Department via 911. For less than 2.5 gallons, use WI-00241 High Hazard Chemical Incidental Spill Response Procedure. Only personnel who are hazmat trained are authorized to clean up the following material. See Appendix 4)c)i). (1) Hydrofluoric acid (2) Nitric acid (3) Nitric-hydrofluoric acid mix (4) Sulfuric acid (5) Sodium hydroxide (pH Lab "caustic") (6) Bonderite/Alodine raw material
d) For other spills, if safe to do so: i) Stop the spill at the source ii) Contain the spill by laying down booms and pads iii) Clean up spills with sorbents and pads iv) Label waste containers
e) Evacuation i) Evacuation is initiated by pulling a fire alarm, which are located by each pedestrian door exit ii) The primary rally locations are as follows: (1) Muster Point 1: the grassy area at the north corner of the facility property at the end of Parking Lot C closest to the front gate. (2) Muster Point 2: the east end of Parking Lot D near the gate iii) The EC or designee will instruct personnel to stay out of the way of emergency response vehicles.
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Coxsackie, New York
Last Reviewed Date: 2/1/24
Revision No.: D
Page: 16 of 33
iv) If the wind is blowing smoke towards a muster point or other unfavorable condition, the EC or designee will instruct personnel to report to an upwind muster point.
v) The EC or designee will direct two personnel to stand at each gate to direct emergency vehicles and incoming personnel if the event happens during a shift change
vi) The team leads or EC designee will take a head count and report to the EC and the fire department if there are any personnel missing
vii) Personnel will remain at the rally points until dismissed by the EC or designee, manager or team lead
viii) Cold weather evacuation:
(1) Personnel will be advised to maintain extra clothing in their cars during cold weather months in the event of evacuation
(2) When evacuation is initiated, personnel are to report to and remain at their muster point until they are cleared by the EC or designee to go to their cars to retrieve the extra clothing
(3) Team leads and managers should allow personnel to proceed to their cars two at a time or in some other orderly fashion
f) Supporting Personnel and Duties
(1) Dispatch supporting personnel to execute their duties listed in Appendix 7.3. See Section 7.3 of the Contingency Plan for more information.
Coxsackie, New York
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Last Reviewed Date: 2/1/24
Revision No.: D
Title Page
Page: 32 of 33
RCRA Contingency Plan
Ducommun AeroStructures New York Coxsackie, NY
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 1 of 33
Contents
1. Introduction........................................................................................................................................................2 2. Emergency Procedures.......................................................................................................................................2 3. Emergency Equipment .......................................................................................................................................4 4. Chemicals............................................................................................................................................................5 5. Site Safety Map...................................................................................................................................................5 6. Post Emergency Actions .....................................................................................................................................6 7. Responsibilities ...................................................................................................................................................6 8. Copies of contingency plan.................................................................................................................................7 9. Arrangements with Authorities ..........................................................................................................................7 10. Amendment of the Contingency Plan ............................................................................................................. 10 11. Training ............................................................................................................................................................ 10 Map - 2' x 3' to be posted at the front of the plan................................................................................................. 12 Appendix 2.1 - Immediate Emergency Procedures - to be posted at the front of the plan ................................... 13 Appendix 2-1)a) - Shelter In Place (Tornado) (WI-00242)....................................................................................... 17 Appendix 2-1)b) - Medical Emergency (WI-00251) ................................................................................................ 18 Appendix 2-4)b)b)iii) - Start Fire Pump (WI-00250)................................................................................................ 19 Appendix 2.4 - Utility Shutoffs (WI-00240).............................................................................................................. 20 Appendix 3.c)i) - WI-00241 High Hazard Chemical Incidental Spill Response Procedure........................................ 21 Appendix 3.1 - Emergency Equipment (F-00637) .................................................................................................... 22 Appendix 4.1.5.1 - Chemical Line Tank Concentrations .......................................................................................... 23 Appendix 4.2 - Safety Data Sheets - to be posted at the end of the plan .............................................................. 25 Appendix 7.1 - Emergency Contact Information (F-00639) - to be posted at the front of the plan...................... 26 Appendix 7.3 - Supporting Personnel ..................................................................................................................... 27 Appendix 9.4.4.2 - Agreement with Veolia.............................................................................................................. 30
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Coxsackie, New York
Last Reviewed Date: 2/1/24
Revision No.: D
Page: 2 of 33
1. Introduction
1.1. Because the facility is a Large Quantity Generator (LQG) of RCRA hazardous waste, Ducommun AeroStructures New York, Inc. (DASNY) located at 171 Stacey Road, Coxsackie, New York, is subject to Title 6 New York Codes, Rules and Regulations 373-3.3 [preparedness and prevention] and 373-3.4 [contingency plans and emergency procedures].
1.2. This Contingency Plan (plan) is designed to minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to air, soil, or surface water.
1.3. This plan describes the actions facility personnel will take to comply with 6 CRR NY 373-3.3 and 3733.4 in response to fires, explosions, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to air, soil, or surface water at the facility.
1.4. This plan also incorporates actions for emergencies not related to hazardous waste that include fires, spills, explosions and excludes shelter in place emergencies such as a tornado as well as responses to medical emergencies other than summoning emergency response services.
1.5. DASNY personnel will immediately implement the provisions of this plan whenever there is a fire, explosion, or release of hazardous waste or hazardous waste constituents which could threaten human health or the environment or a Shelter In Place or Medical Event. See Appendix 2.1.
2. Emergency Procedures
2.1. The immediate emergency procedures, which will be executed by the Emergency Coordinator or Emergency Coordinator Designee during the off shift, are located in Appendix 2.1, Immediate Emergency Procedures, which will be posted in the front of the plan for ease of reference.
2.2. The Emergency Coordinator will also:
2.2.1.Notify other appropriate State or local agencies with designated response roles if their help is needed.
2.2.2.Whenever there is a release, fire, or explosion, immediately identify the character, exact source, amount, and areal extent of any released materials. They may do this by observation or review of facility records or manifests and, if necessary, by chemical analysis.
2.2.3.Concurrently, assess possible hazards to human health or the environment that may result from the release, fire, or explosion. This assessment must consider both direct and indirect effects of the release, fire, or explosion (e.g., the effects of any toxic, irritating, or asphyxiating gases that are generated, or the effects of any hazardous surface water run-offs from water or chemical agents used to control fire and heat-induced explosions).
2.2.3.1. If the emergency coordinator determines that the facility has had a release, fire, or explosion which could threaten human health, or the environment, outside the facility, they must report their findings as follows:
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Coxsackie, New York
Last Reviewed Date: 2/1/24
Revision No.: D
Page: 3 of 33
2.2.3.1.1.
If their assessment indicates that evacuation of local areas may be advisable, they
must immediately notify appropriate local authorities. They must be available to help
appropriate officials decide whether local areas should be evacuated; and
2.2.3.1.2.
They must immediately notify either the government official designated as the
on-scene coordinator for that geographical area, or the National Response Center (using
their 24-hour toll free number 800/424-8802). The report must include:
2.2.3.1.2.1. Name and telephone number of reporter;
2.2.3.1.2.2. Name and address of facility;
2.2.3.1.2.3. Time and type of incident (e.g., release, fire);
2.2.3.1.2.4. Name and quantity of material(s) involved, to the extent known;
2.2.3.1.2.5. The extent of injuries, if any; and
2.2.3.1.2.6. The possible hazards to human health, or the environment, outside the facility.
2.2.4.During an emergency, take all reasonable measures when it is safe to do so necessary to ensure that fires, explosions, and releases do not occur, recur, or spread to other hazardous waste at the facility. These measures must include, where applicable, stopping processes and operations, collecting and containing released waste, and removing or isolating containers.
2.2.5.If the facility stops operations in response to a fire, explosion or release, must monitor for leaks, pressure buildup, gas generation, or ruptures in valves, pipes, or other equipment, wherever this is appropriate and safe to do so.
2.3. Evacuation
2.3.1.See Section 4)e) of Appendix 2.1
2.4. Utility Shutoffs
2.4.1.WI-00240 provides the instructions on the Utility Shutoffs, which is included in Appendix 2.4 of this plan.
2.5. Reportable Spills
2.5.1.The Emergency Coordinator or a supporting Emergency Coordinator must implement the reporting requirements of this section as soon as an emergency is stabilized.
2.5.2.Reportable spills include:
2.5.2.1. The following materials spilled or leaked into the environment in the quantities listed below or greater that cannot be recovered (cleaned up):
NAME
Acetone Sodium hydroxide
CAS/313 Category Codes 67-64-1 1310-73-2
Reportable Quantity
Air Land/water
5000
1
1000
100
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Coxsackie, New York
Last Reviewed Date: 2/1/24
Revision No.: D
Page: 4 of 33
Hydrofluoric acid (conc. 50% or greater) Sulfuric acid
Nitric acid
Chromic acid
7664-39-3
7664-93-9 7697-37-2 7738-94-5
100
100
1000
100
1000
100
10
10
2.5.2.2. The National Response Center (NRC) (800-424-8802) within 15 minutes and the NYS Spill Hotline (1-800-457-7362) within 2 hours of discovery must be contacted in the event of a reportable spill listed above.
2.5.2.3. Petroleum:
2.5.2.3.1.
EPA/National Response Center
2.5.2.3.1.1. EPA has established requirements to report spills to navigable waters or adjoining shorelines. EPA has determined that discharges of oil in quantities that may be harmful to public health or the environment must be reported to the Natural Response Center (800-424-8802) within 15 minutes and include those that:
2.5.2.3.1.2. Violate applicable water quality standards;
2.5.2.3.1.3. Cause a film or "sheen" upon, or discoloration of the surface of the water or adjoining shorelines; or
2.5.2.3.1.4. Cause a sludge or emulsion to be deposited beneath the surface of the water or upon adjoining shorelines.
2.5.2.3.2.
All petroleum spills that occur within New York State (NYS) must be reported to
the NYS Spill Hotline (1-800-457-7362) within 2 hours of discovery, except spills which
meet all of the following criteria:
2.5.2.3.2.1. The quantity is known to be less than 5 gallons; and
2.5.2.3.2.2. The spill is contained and under the control of the spiller; and
2.5.2.3.2.3. The spill has not and will not reach the State's water or any land; and
2.5.2.3.2.4. The spill is cleaned up within 2 hours of discovery.
2.5.2.3.2.5. A spill is considered to have not impacted land if it occurs on a paved surface such as asphalt or concrete. A spill in a dirt or gravel parking lot is considered to have impacted land and is reportable.
3. Emergency Equipment
3.1. Form F-00637 Emergency Equipment List - EMS, which is included in Appendix 3.1 provides a list of all emergency equipment related to hazardous waste at the facility (such as fire extinguishing systems, spill control equipment, communications and alarm systems (internal and external), and decontamination equipment), where this equipment is required. This list will be kept up to date. This
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Coxsackie, New York
Last Reviewed Date: 2/1/24
Revision No.: D
Page: 5 of 33
list also includes the location and a physical description of each item on the list, and a brief outline of its capabilities. 3.2. A bin located at the Pump House that contains emergency equipment such as radios, flashlights with wands, a copy of the Contingency Plan, and safety data sheets of high-risk chemicals are located inside the Pump House. 4. Chemicals 4.1. Chemicals onsite include but is not limited to: 4.1.1.Raw chemical storage sheds: 4.1.1.1. Hydrofluoric acid 4.1.1.2. Nitric acid 4.1.1.3. Acetone (99% - 100%) 4.1.2.Receiving Door #5 at Blank Cell 4.1.2.1. Acetone (99% - 100%) 4.1.2.2. Isopropyl Alcohol (99%) 4.1.3.Hazardous waste storage shed: 4.1.3.1. Spent nitric-hydrofluoric acid mix 4.1.3.2. Spent Bonderite solution 4.1.3.3. Spent Alodine solution 4.1.4.pH Lab 4.1.4.1. Sulfuric acid 4.1.4.2. Sodium hydroxide 4.1.5.Chemical lines. 4.1.5.1. Chemical line chemicals and their concentrations in the tanks are listed in Appendix 4.1.5.1. 4.2. Safety data sheets for the chemicals listed in this section are included in Appendix 4.2. 4.3. The facility contains other chemicals including 55-gallon drums of acetone and waste paint. 5. Site Safety Map F-00646 provides the Site Safety Map, which will be posted in the front of the plan (two copies), which shows the location of: 5.1. Chemical storage areas 5.2. Evacuation points
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Coxsackie, New York
Last Reviewed Date: 2/1/24
Revision No.: D
Page: 6 of 33
5.3. Other information including:
5.3.1.Fire extinguishers 5.3.2.AEDs 5.3.3.First aid 5.3.4.Eye wash stations 5.3.5.Emergency phone 5.3.6.Shelter-in-place 5.3.7.General location of hot ovens and presses
6. Post Emergency Actions 6.1. Immediately after an emergency, the emergency coordinator must provide for treating, storing, or disposing of recovered waste, contaminated soil or surface water, or any other material that results from a release, fire, or explosion at the facility.
6.2. The emergency coordinator must ensure that, in the affected area(s) of the facility:
6.2.1. No waste that may be incompatible with the released material is treated, stored, or disposed of until cleanup procedures are completed; and
6.2.2. All emergency equipment listed in the contingency plan is cleaned and fit for its intended use before operations are resumed.
6.2.3. The owner or operator must note in the operating record the time, date, and details of any incident that requires implementing the contingency plan.
6.2.4. Within 15 days after the incident, he must submit a written report on the incident to the Regional Administrator if the Contingency Plan is invoked for an incident related to RCRA hazardous waste. The report must include:
6.2.4.1. Name, address, and telephone number of the owner or operator;
6.2.4.2. Name, address, and telephone number of the facility;
6.2.4.3. Date, time, and type of incident (e.g., fire, explosion);
6.2.4.4. Name and quantity of material(s) involved;
6.2.4.5. The extent of injuries, if any;
6.2.4.6. An assessment of actual or potential hazards to human health or the environment, where this is applicable; and
6.2.4.7. Estimated quantity and disposition of recovered material that resulted from the incident.
7. Responsibilities 7.1. Emergency contact information is included on F-00639 Emergency Response Contact Information, which is included in Appendix 7.1, which will be posted in the front of the plan.
7.2. Emergency Coordinator
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Coxsackie, New York
Last Reviewed Date: 2/1/24
Revision No.: D
Page: 7 of 33
7.2.1.At all times, there must be at least one employee either on the facility premises or on call (i.e., available to respond to an emergency by reaching the facility within a short period of time) with the responsibility for coordinating all emergency response measures. This emergency coordinator must be thoroughly familiar with all aspects of the facility's contingency plan, all operations and activities at the facility, the location and characteristics of wastes and chemicals handled, the location of all records within the facility, and the facility layout. In addition, this person must have the authority to commit the resources needed to carry out the contingency plan.
7.2.2.In the absence of the primary Emergency Coordinator, Emergency Coordinator duties will `roll' down to the alternates in the order they are presented in the Emergency Contact Information.
7.2.2.1. When contacting the Emergency Coordinators, personnel will start with the primary and continue down the list in order until an Emergency Coordinator responds
7.2.3.During the off shift, the onsite manager, team lead or other identified designee will serve as the Emergency Coordinator Designee until the Emergency Coordinator arrives. The Emergency Coordinator Designee must be familiar with the Appendix 2.1, Immediate Emergency Procedures.
7.3. Supporting Personnel
7.3.1.The Assistant Emergency Coordinator for the off shift (second shift [non-business hours], third shift and weekends) will be identified in advance. The role of the Assistant Emergency Coordinator is to provide direction to the other supporting personnel in an actual event or drill.
7.3.2.The list of other supporting personnel are listed in Appendix 7.3. These personnel should exclude first aid and spill responders.
7.3.3.Training is discussed in Section 11.
8. Copies of contingency plan. 8.1. A copy of the Contingency Plan and all revisions to the plan must be:
8.1.1.Maintained at the facility:
8.1.1.1. In Compliant Pro
8.1.1.2. In the bin at the Pump House
8.1.1.3. In the drawer of the table near the Receptionist restrooms
8.1.1.4. With the listed Emergency Coordinators
8.1.2.Submitted to all local police departments, fire departments, hospitals, and State and local emergency response teams that may be called upon to provide emergency services.
9. Arrangements with Authorities 9.1. This section describes the arrangements agreed to by local police departments, fire departments, hospitals, contractors, and State and local emergency response teams to coordinate emergency services.
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Coxsackie, New York
Last Reviewed Date: 2/1/24
Revision No.: D
Page: 8 of 33
9.2. See Section 8 for distribution of the Contingency Plan
9.3. Emergency contact information is included on F-00639 Emergency Response Contact Information, which is included in Appendix 7.1.
9.4. Agencies and Organizations
9.4.1. The responding Fire Departments are as follows:
9.4.1.1. Village of Coxsackie Fire Department (primary for spills, fires and explosions)
9.4.1.1.1.
Coxsackie Hose Company #3 P.O. Box 303 Coxsackie, NY 12051
9.4.1.1.2. Email address: firechief@villageofcoxsackie.com
9.4.1.1.3. Once a year, DASNY invites Village of Coxsackie Fire Department for a tour of the facility to allow them to become acquainted with the facility operations and layout
9.4.1.2. Earlton Fire House
9.4.1.2.1.
1561 New York 81 Earlton, NY 12058
9.4.2. Ambulance
9.4.2.1. Coxsackie Ambulance is the primary responding agency for injury response.
9.4.2.2. Mailing Address:
56 Bailey St Town of Coxsackie, NY 12051
9.4.2.3. Physical address:
117 Mansion Street Coxsackie, NY 12051
9.4.2.4. Email address: emschief@coxsackie.org
9.4.2.5. Non-emergency phone number: (518) 731-EMTS (731-3687)
9.4.3. Law Enforcement
9.4.3.1. The local law enforcement agencies are:
9.4.3.1.1.
New York State Police Troop F Zone 1 South Cairo, NY 12482
9.4.3.1.2. Greene County Sheriffs Office
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Coxsackie, New York
Last Reviewed Date: 2/1/24
Revision No.: D
Page: 9 of 33
45 Haverly Mem Dr Coxsackie, NY 12051
9.4.3.1.3. Greene County Sheriffs Office 119 Mansion Street Coxsackie N.Y. 12051
Email address: sheriff@greenesheriffny.com
9.4.4. Local Emergency Planning Commission (LEPC)/State Emergency Response Commission (SERC)
9.4.4.1.1.
Greene County Emergency Operations (LEPC) 25 Volunteer Dr Cairo, NY 12413
9.4.4.1.2.
NYS Emergency Management Office 1220 Washington Ave, Building 22, Suite 101 Albany, NY 12226
Email address: SERC.OEM@dhses.ny.gov
9.4.5. Veolia
9.4.5.1. The third party contractor for spill response is Veolia; however, DASNY will contact the Village of Coxsackie Fire Department first
9.4.5.2. The facility maintains a contract with Veolia for spill response services, which is included in Appendix 9.4.4.2 of this plan.
9.4.6. Hospital
9.4.6.1. The hospitals to which the Continency Plan will be sent include:
9.4.6.1.1. Columbia Memorial Hospital 71 Prospect Ave Hudson, NY 12534
9.4.6.1.2. St. Peter's Hospital 315 South Manning Blvd., Albany, NY 12208
9.4.7. Urgent Care
9.4.7.1. The UrgentCare to which the Contingency Plan will be sent:
9.4.7.1.1. EmUrgentCare 11835 State Rt. 9W
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Coxsackie, New York
Last Reviewed Date: 2/1/24
Revision No.: D
Page: 10 of 33
West Coxsackie, NY 12192
10. Amendment of the Contingency Plan 10.1. The contingency plan must be reviewed, and immediately amended, if necessary, whenever: 10.1.1. Applicable regulations are revised; 10.1.2. The plan fails in an emergency; 10.1.3. The facility changes--in its design, construction, operation, maintenance, or other circumstances--in a way that materially increases the potential for fires, explosions, or releases of hazardous waste or hazardous waste constituents, or changes the response necessary in an emergency; 10.1.4. The list of emergency coordinators changes; or 10.1.5. The list of emergency equipment changes.
11. Training 11.1. Personnel will be trained annually as follows: 11.1.1. Emergency Coordinators 11.1.1.1. On the entirety of the plan and their duties outlined therein 11.1.2. Emergency Coordinators Designees 11.1.2.1. The Emergency Coordinator Designee must be familiar with: 11.1.2.1.1. The Immediate Emergency Procedures in Appendix 2.1 11.1.3. Team leads: 11.1.3.1. The Immediate Emergency Procedures in Appendix 2.1 11.1.3.2. Their duty to identify supporting personnel during the off-shifts 11.1.4. Supporting personnel 11.1.4.1. The Assistant Emergency Coordinator - Instructions to provide to other Supporting Personnel 11.1.4.2. Department heads - their department duties during first shift 11.1.5. All employees 11.1.5.1. Evacuation plan 11.1.5.2. To contact the Emergency Coordinators if they have questions about the Contingency Plan 11.1.5.3. Shelter in Place (Tornado) Plan 11.1.6. First Aid Responders - first aid
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 11 of 33
[Blank - Reserved]
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 21 of 33
Appendix 3.c)i) - WI-00241 High Hazard Chemical Incidental Spill Response Procedure
Coxsackie, New York
Last Reviewed Date: 10/24/23
Work Instruction: WI-00241
High Hazard Chemical Incidental Spill Response Procedure
Revision No.: B
Page: 1 of 6
PURPOSE (OBJECTIVE)/SCOPE Provide instructions on responding to releases outside of primary containment for the following materials:
Hydrofluoric acid Nitric acid Nitric hydrofluoric Bonderite/Alodine Sulfuric acid pH lab caustic (sodium hydroxide) Alko-N if wet or in solution Oakite 61b if wet or in solution
Consult WI-00237 RCRA Contingency Plan for more extensive instructions on evacuation and other emergency response procedures.
APPLIES TO Ducommun AeroStructures New York Inc.
PROCEDURE 1. Discovering personnel. Upon discovery of release or potential release of the material listed
above outside of primary (intended) containment, discovering personnel will: 1.1 Direct personnel in the immediate area to clear the area within a 50-foot radius 1.2 Immediately notify their supervisor 1.3 Personnel are empowered to initiate an evacuation by pulling a fire alarm 2. Team Lead/Supervisor. The team lead/supervisor will: 2.1 Assess the spill 2.2 Evacuation and Outside HazMat Team
2.2.1 Plant evacuation and summoning the Outside HazMat Team via the Fire Department by calling 911 will be necessary under the following conditions: 2.2.1.1 Spill greater than 2 gallons 2.2.1.2 Visible vapor cloud 2.2.1.3 Odor detected
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Last Reviewed Date: 10/24/23
Work Instruction: WI-00241
High Hazard Chemical Incidental Spill Response Procedure
Revision No.: B
Page: 2 of 6
2.2.2 Pull fire alarm to evacuate
2.2.3 Call 911 to contact the Fire Department to summon the HazMat team
2.2.4 Summon contract spill team (e.g., Veolia) if deemed necessary
2.2.5
Instruct personnel to shut down processes if safe to do so (e.g., shut down can be done from another location; easy, single switch or valve operation as they are evacuating, etc.)
2.2.6 Consult WI-00237 RCRA Contingency Plan for more extensive instructions on evacuation and other emergency response procedures
2.3 If evacuation and outside hazmat team not required, clear the area 50-feet away of personnel
2.4 Control pedestrian traffic while remaining at a safe distance including providing verbal instructions and setting up barricades. Personnel may be instructed to assist in this step if safe to do so. See Section 4.
2.5 Notify the EHS Manager and the Hazmat Technicians by announcing over the PA system "HazMat team to [Area]". (See Appendix 2.5 for F-00639 Emergency Response Contact Information for more contact information). Inform them of the following:
2.5.1 Material released
2.5.2 Quantity
2.5.3 Location
2.5.4 Source of the spill
2.5.5 If the spill is ongoing
2.5.6 Other identified hazards
3. HazMat Technicians
HazMat Technicians must be HAZWOPER trained!!
If summoned to a spill, the HazMat Technicians will: 3.1 Respond as a team of four minimum 3.2 Two will `suit up' and respond. Two will serve as attendants. See Section 4. 3.3 Assess the spill and confirm the supervisor's assessment (e.g., material released, size, the
emergency response, safe distances, etc.) including the need for evacuation. See paragraph 2.2 for more information on plant evacuation.
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Last Reviewed Date: 10/24/23
Work Instruction: WI-00241
High Hazard Chemical Incidental Spill Response Procedure
Revision No.: B
Page: 3 of 6
3.4 Put on the appropriate PPE. See Table 3.4 of this document.
3.5 Assess the source of the spill
3.6 If the spill is ongoing and is beyond drops or weeps, STOP and call the fire department
3.7 If the spill is ongoing as drops or weeps, stop the spill if safe to do so
3.8 Use pads and socks designed for high concentration acids (`chemical/hazmat', `chemical hazmat') to contain and clean up the spill. Preferred:
3.9 Neutralize the spill with a compatible neutralizer such as Amphomag or a dilute calciumor magnesium-based neutralizer. Do not use potassium- or sodium-based neutralizers. Follow the instructions and add neutralizer slowly to prevent excess reactions.
3.9.1 Instructions for Amphomag:
3.9.1.1 Pour Amphomag slowly and directly onto the spill to contain and neutralize
3.9.1.2 The Amphomag will initially turn:
3.9.1.2.1 Reddish/pink to indicate that it is an acid
3.9.1.2.2 Blue to indicate that it is a base (caustic)
3.9.1.2.3
Yellow/green and when fully neutralized. Be aware that the material may still be reactive even when color indicates it is neutralized.
3.9.1.3
If there is any acid or base remaining anywhere based on the color, repeat step 3.9.1.2 until the color indicates that the material is neutralized.
3.9.1.4 Guidance on needed quantity spilled material for neutralization is below:
70% HF = 11 lbs Amphomag/gal spilled material
68% HNO3 = 4 lbs Amphomag/gal spilled material
Bonderite: 7% HF/40%HNO3 = 3.3 lbs Amphomag/gal spilled material
25% sodium hydroxide = 1.8 lbs Amphomag/lb of spilled material
50% sulfuric acid = 0.65 lbs Amphomag/lb of spilled material
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Last Reviewed Date: 10/24/23
Work Instruction: WI-00241
High Hazard Chemical Incidental Spill Response Procedure
Revision No.: B
Page: 4 of 6
3.10 Equipment and Supplies
3.10.1 See Attachment 3.10 of this work instruction for preferred equipment. Attachment 3.10 contain Tables 1 and 2 from F-00637, Emergency Equipment List.
3.10.2 To absorb neutralized fluids or sweep up neutralizer or sorbent, use chemically non-reactive material including polypropylene materials/equipment with no metal parts.
3.10.3 Use pumps for the correct material. Using the wrong pump for these chemicals can damage the pump and create a safety risk.
3.11 Place cleaned up neutralized material in the following labeled drum type:
Spilled Material
Drum Material
Nitric acid
Stainless steel
Alko-N if wet or in solution
Carbon steel
Hydrofluoric acid
Nitric hydrofluoric
Bonderite/Alodine Sulfuric acid
Polyethylene
pH lab caustic (sodium hydroxide)
Oakite 61B if we or in solution
4. Attendants
4.1 The supervisor or designee will provide direction to the attendants 4.2 Attendants must:
4.2.1 Wear the following PPE: 4.2.1.1 Safety glasses 4.2.1.2 Safety boots 4.2.1.3 Latex/nitrile gloves
4.2.2 Remain at a safe distance and must not approach the spill 4.2.3 Stay out of visible vapor
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Last Reviewed Date: 10/24/23
Work Instruction: WI-00241
High Hazard Chemical Incidental Spill Response Procedure
Revision No.: B
Page: 5 of 6
4.2.4 Move away if they can smell an odor 4.2.5 Assist the responders by:
4.2.5.1 Retrieving supplies such as spill control material and depositing them at a safe distance to for responders to retrieve
4.2.5.2 Control traffic 5. Decontamination procedures:
5.1 For trace contamination, responding personnel will use a wet rag to wipe down the gear that they are wearing using wet rags provided by the assistants
5.2 For greater contamination, responding personnel will wipe down the gear that they are wearing using sorbent pads provided by the assistants
5.3 Responding personnel will then rinse their gear prior to removal of at either: 5.3.1 VS3 Cleaning Line; or 5.3.2 Outside at the southeast end of the building: 5.3.2.1 Assistants will set up the pallet stored at the southeast end of the building 5.3.2.2 Position the pallet outside near the spray hose at the southeast end of the building
5.4 PPE used in the implementation of this procedure should be thrown away 6. EHS Manager or designee. Provide for onsite technical support
7. Work Instruction Copies 7.1 Hard copies of this Work Instruction will be stored with the RCRA Contingency Plan and with each Ducommun HazMat Technician response kit.
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Last Reviewed Date: 10/24/23
Work Instruction: WI-00241
High Hazard Chemical Incidental Spill Response Procedure
Revision No.: B
Page: 6 of 6
Attachment 3.10
PPE from F-00637 Emergency Equipment List Tables 1 and 2
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 19 of 33
Appendix 2-4)b)b)iii) - Start Fire Pump (WI-00250)
WI-00250 Start Fire Pump - EMS
Page: 1 of 4
Coxsackie, New York Last Reviewed Date: 7/28/23 Revision No.: A
1. Purpose
The purpose of the Work Instruction is to provide Ducommun AeroStructures New York, Inc. (DAS NY) Maintenance personnel as well as second and third shift team leads with instructions on how to start the fire pump at the Pump House.
2. Scope
The scope is for the facility at 171 Stacey Road, Coxsackie, New York.
3. Responsibilities
3.1. It is the responsibility of the EHS Manager to: 3.1.1. Revise this document 3.1.2. Provide training to applicable personnel
3.2. It is the responsibility of the Maintenance personnel and second and third shift team leads to know how to start the fire pump 3.2.1. If regularly scheduled Maintenance personnel will not be onsite, the Maintenance Team Lead or designee will notify the applicable shift team lead 3.2.2. If the second or third shift team lead will not be onsite, they must select a step up to operate the fire pump in their absence and to train that person
3.3. It is Maintenance's responsibility to start the fire pump; however, in their absence, it is the team lead's responsibility on second and third shift.
4. Definitions
4.1. Step up: person assigned to take the place of an absent leader
5. Procedure
5.1. The fire pump is located at the "Pump House", which is located along the main driveway to the facility. See Figure 1.
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
WI-00250 Start Fire Pump - EMS
Page: 2 of 4
Coxsackie, New York Last Reviewed Date: 7/28/23 Revision No.: A
Pump House
Figure 1
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
WI-00250 Start Fire Pump - EMS
Page: 3 of 4
Coxsackie, New York Last Reviewed Date: 7/28/23 Revision No.: A
5.2. Method 1 for Starting the Fire Pump 5.2.1. The Diesel Fire Pump Controller is located in the Pump House. See Figure 2.
Figure 2
5.2.2. Open the test valve at the bottom of the Controller. See Figure 3. You will see some water flow through the hose onto the floor.
Figure 3
5.2.3. Immediately close it again. 5.2.4. Opening the valve will cause a pressure drop and the pump to start.
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
WI-00250 Start Fire Pump - EMS
Page: 4 of 4
Coxsackie, New York Last Reviewed Date: 7/28/23 Revision No.: A
5.3. Method 2 for Starting the Fire Pump 5.3.1. On the Control Panel (Figure 4) on the Diesel Fire Pump Controller (Figure 3): Figure 4
5.3.2. Turn the black dial to `MAN. 1' (manual) 5.3.3. Press the green START button to start the pump 5.4. Method 3 for Starting the Fire Pump 5.4.1. On the fire pump itself, push one of the two start switches up to start the pump. See
Figure 5. This method can be used in the event of a power or battery failure.
Figure 5
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 20 of 33
Appendix 2.4 - Utility Shutoffs (WI-00240)
WI-00240 Utility Shutoff - EMS
Coxsackie, New York Last Reviewed Date: 10/24/23 Revision No.: B
Page: 1 of 8
1. Purpose
The purpose of the Work Instruction is to provide Ducommun AeroStructures New York, Inc. (DAS NY) Maintenance personnel as well as emergency response authorities guidance on the locations and instructions for main utility shutoffs.
2. Scope
The scope is the utilities for the facility at 171 Stacey Road, Coxsackie, New York. Utilities included in this Work Instruction include electrical, water including sprinkler risers and natural gas.
3. Responsibilities
3.1. It is the responsibility of the EHS Manager to: 3.1.1. Revise this document 3.1.2. Provide training to Maintenance personnel 3.1.3. Submit this document to emergency response authorities as part of the RCRA Contingency Plan (WI-00237)
3.2. It is the responsibility of the Maintenance personnel to know how to shut of the utilities to the building
3.3. It is the responsibility of the Emergency Coordinators and designees, as defined in WI-00237 RCRA Contingency Plan, to have awareness of this procedure
4. Definitions
4.1. [RESERVED]
5. Procedure
5.1. Maintenance personnel will shut off the utilities in accordance with this work instruction when instructed to do so by: 5.1.1. Municipal, state, or contract emergency response personnel such as the fire department or hazmat team
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
WI-00240 Utility Shutoff - EMS
Coxsackie, New York Last Reviewed Date: 10/24/23 Revision No.: B
Page: 2 of 8
5.1.2. Maintenance Team Lead 5.1.3. Any manager 5.2. Locations 5.2.1. Locations of the shut offs are provide in Figure 1, which is a map of the facility 5.2.2. A verbal description of the locations are include in Table 1. 5.3. Designations, instructions for shutoff and a photograph are include in Table 1.
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Work Instruction: WI-00240 Utility Shutoff
Coxsackie, New York
Last Reviewed Date: 10/24/23
Revision No.: B
Page: 3 of 8
Natural gas main valve
Two-inch water main Sprinkler system
risers
Switch Gear 1
Nitrogen shutoff Argon shutoff
Switch Gear 2
Facility Water Main next to Fire Pump House
North
Three-inch water main
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Figure 1
Work Instruction: WI-00240 Utility Shutoff
Coxsackie, New York
Last Reviewed Date: 10/24/23
Revision No.: B
Page: 4 of 8
Utility
Electrical
Designation
Switch Gear 1
Switch Gear 2
Location Description
Maintenance Electrical Utility Room in Maintenance Department at north corner of the major section of the building
Compressor Room at the west end along the right side of the major section of the building
Instruction for Shut Photograph Off
Pull lever down
Pull lever down
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Work Instruction: WI-00240 Utility Shutoff
Coxsackie, New York
Last Reviewed Date: 10/24/23
Revision No.: B
Natural Gas
Natural gas main valve
Fire Riser Room in corner at north corner of the major section of the building
Turn valve with wrench
Page: 5 of 8
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Work Instruction: WI-00240 Utility Shutoff
Coxsackie, New York
Last Reviewed Date: 10/24/23
Revision No.: B
Page: 6 of 8
Water
Two-inch main
Fire Riser Room behind the risers at north corner of the major section of the building
Turn both handles 90 degrees to pipe
Three-inch main
pH Lab Area at Turn handles
northeast corner of 90 degrees to
the building
flow of pipe
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Work Instruction: WI-00240 Utility Shutoff
Coxsackie, New York
Last Reviewed Date: 10/24/23
Revision No.: B
Page: 7 of 8
Water
Facility Water Main
East end of Fire Pump House next to front driveway.
Key to Pump House is in a combination lock box by the door.
Turn valve. The curb key wrench is stored in the Pump House.
Sprinkler System Risers
Sprinkler System Risers
Fire Riser Room in corner at north corner of the major section of the building
Unlock valves. Turn valves.
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Work Instruction: WI-00240 Utility Shutoff
Coxsackie, New York
Last Reviewed Date: 10/24/23
Revision No.: B
Nitrogen Argon
Nitrogen Shutoff
Argon Shutoff
Near "Argon tank location", south end of Parking Lot C.
Key to enclosure is in a combination lock box near the enclosure gate.
Turn valves 90 degrees to the pipe
Page: 8 of 8
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 22 of 33
Appendix 3.1 - Emergency Equipment (F-00637)
Coxsackie, New York
Last Reviewed Date: 11/7/23
Form No.: F-00637 Emergency Equipment List & Inspection Form - EMS
Work Instruction: WI-006216 RCRA Contingency Plan
Revision No.: B
Page: 1 of 8
TABLE 1: SPILL RESPONSE KIT (PRIMARY) - Equipment location on F-00646 Site Safety Map
PPE/EQMT SHORT DESCRIPTION PREFERRED
QTY
Gloves
Neoprene or Butyl of at least 22 mil or Butyl Viton
SHOWA; Chemical Resistant Gloves, 2XL, Glove Materials Butyl/Viton, 1 PR. Grainger Item # 56JH88; Mfr. Model #890-09
SHOWA Chemical Resistant Gloves: 14 mil Glove Thick, 14 in Glove Lg, Grain, 7 Glove Size, Black, 1 PR; Item # 191P06; Mfr. Model # 874R-07; UNSPSC # 46181504K2844
Each responder has a set.
One of each size available with each set with spill kit.
Boots
Butyl Overboots ANDAX INDUSTRIES CBRN AIRBOSS; Sku: ABB2306-L
Each responder has a set.
One of each size available with each set with spill kit.
Respirator Helmet M-405
3MTM VersafloTM Respiratory Helmet Assembly M405, with Standard Visor and Shroud, 1 EA/Case
Part Number 173223M Product Number M4053M ID 7100009447UPC 00051131173224
Each responder has one. One available with spill kit.
CAPACITY Chemical resistance including against hydrofluoric acid and nitric acid
Chemical resistance including against hydrofluoric acid and nitric acid For use with supplied air.
Breathing Tube BT-30
Breathing Tube: Versaflo, TR-300 Series/Versaflo Air Source/Versaflo Headtop; Grainger Item 11W054Mfr. Model BT-30
Each responder has one. One available with spill kit.
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Form No.: F-00637 Emergency Equipment List & Inspection Form - EMS
Coxsackie, New York
Last Reviewed Date: 11/7/23
Work Instruction: WI-006216 RCRA Contingency Plan
Revision No.: B
Page: 2 of 8
3MTM Supplied Air Respirator Hose W-943550/07011(AAD)
Air Regulator Assembly
Blast Air Cart
3MTM Supplied Air Respirator Hose W-943550/07011(AAD), 1 EA/Case
Part Number 070113M Product Number W-9435503M ID 7000005373UPC 00051131070110
Air Regulating Assembly: Air Regulating Valves, 3M Versaflo, 3M, Valve/Waist Belt, Versaflo
Item 1AGD9Mfr. Model V-300
Air Systems International BA-50 Breather Box with cart connected to compressed air system
One available with spill kit. One available with spill kit. One available with spill kit.
Coveralls Sorbents
Breather box; Air Pack Tychem 5000
Sorbent rolls
Sorbent pads
Air Systems International BB50-CO Breather Box connected to compressed air system
One available at VS 1 Cleaning Line.
DUPONT Hooded Chemical Resistant Coveralls: Tychem(R) 5000, Light Duty, Taped Seam, Tan, L, B, 6 PK, Item 4LTY3Mfr. Model C3127TTNLG000600
BRADY SPC SORBENTS, 40 Gal Capacity per Package, Chemical/Hazmat Roll, 150' Long x 30 Wide, Yellow, Polypropylene; MSC# 84371749, Mfr# CH30DP [BrightSorb High Visibility Safety Absorbent Roll]
BRADY SPC SORBENTS, Pack of (12) 12 Gal, 4' Long, 3 Diam, Polypropylene Socks; Chemical,
Each responder has a set. One of each size available with each set with spill kit.
One with spill kit
Chemical resistance including against hydrofluoric acid and nitric acid
40 gallons
One pack of 12 with spill kit
12 gallons
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Form No.: F-00637 Emergency Equipment List & Inspection Form - EMS
Last Reviewed Date: 11/7/23
Work Instruction: WI-006216 RCRA Contingency Plan
Revision No.: B
Page: 3 of 8
Yellow. MSC# 33778226, Mfr# CH412
Neutralizer
Cleaning supplies
Loose sorbents
Amphomag (only this or other calcium/magnes um-based material)
Brooms, brushes, dust pans, squeegees (Polypropylene, no metal parts)
5.9.1 PIG; Loose Absorbent, Chemical, Polypropylene, 5 lb. Grainger Item # 30RD06; Mfr. Model # HA8010
3 x 5 pound with spill kit
50-pound tote; 3-pound shaker
3 x 3-pound shaker with spill kit
1 x 50-pound tote with spill kit
70% HF = 11 lbs Amphomag/gal spilled material
68% HNO3 = 4 lbs Amphomag/gal spilled material
Bonderite: 7% HF/40%HNO3 = 3.3 lbs Amphomag/gal spilled material
25% sodium hydroxide = 1.8 lbs Amphomag/lb of spilled material
50% sulfuric acid = 0.65 lbs Amphomag/lb of spilled material
PRO-SOURCE; 24 General Purpose Polypropylene Push Broom; 3 Bristle Length, Wood Block,
Threaded Handle Connection, Handle Sold Separately; MSC# 09319310; Mfr# SWP24
1 x each with spill kit
CARLISLE; Angled Brooms; Width (Inch): 12in ; Handle Connection Type: Threaded ; Bristle Material: Polypropylene ; Brush Width: 12in. MSC# 95749271, Mfr# 41082EC09-Old
REMCO; Dust Pans & Scoops; Type: Handheld ;
15 gallons See below
Low chemical reactivity
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Form No.: F-00637 Emergency Equipment List & Inspection Form - EMS
Coxsackie, New York
Last Reviewed Date: 11/7/23
Work Instruction: WI-006216 RCRA Contingency Plan
Revision No.: B
Page: 4 of 8
Dust Pan Type: Handheld ; Width (Inch): 13 ; Body Material: Polypropylene ; Handle Length (Inch): 4 ; Handle Length: 4. MSC# 1439648; Mfr# 558116.
BRUSH RESEARCH MFG. Broom/Squeegee Poles & Handles; Connection Type: Threaded ; Handle Material: Wood. MSC# 95946968; Mfr# H19
REMCO. Counter & Dust Brushes; Type: Bench Brush ; Brush Type: Bench Brush ; Bristle Material: Polypropylene ; Head Length (Inch): 7.0 ; Bristle Firmness: Medium. MSC# 14396865; Mfr# 451119
TOUGH GUY Recycled Trash Bags: 96 gal Capacity, 52 in Wd, 75 in Ht, 2 mil Thick, Black, 50 PK; Grainger Item 6FWH8Mfr. Model 6FWH8
When updated, update WI-00241 High Hazard Chemical Incidental Spill Response Procedure High Hazard Chemicals
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Form No.: F-00637 Emergency Equipment List & Inspection Form - EMS
Coxsackie, New York
Last Reviewed Date: 11/7/23
Work Instruction: WI-006216 RCRA Contingency Plan
Revision No.: B
Page: 5 of 8
TABLE 2: PORTABLE/MOBILE CHEMICAL SERVICE PUMPS
PUMP PICTURE
PUMP; ALLOWED CHEMICALS
Custom changeout pump:
Only for:
Nitric hydrofluoric acid mix
Nitric acid
PUMP PICTURE
PUMP; ALLOWED CHEMICALS Hand (siphon) pump: Only for: Hydrofluoric acid
Shop Vac: Only for: Dilute nitric hydrofluoric acid Dilute nitric acid Dilute hydrofluoric acid
When updated, update WI-00241 High Hazard Chemical Incidental Spill Response Procedure High Hazard Chemicals
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Form No.: F-00637 Emergency Equipment List & Inspection Form - EMS
Coxsackie, New York
Last Reviewed Date: 11/7/23
Work Instruction: WI-006216 RCRA Contingency Plan
Revision No.: B
Page: 6 of 8
TABLE 3: OTHER - Equipment location and quantity on F-00646 Site Safety Map Equipment Fire Extinguisher, ABC* Fire Extinguisher, BC* Fire Extinguisher, CLASS D* Emergency Phone Secondary spill response kit (outside near Maintenance doors)
Version spill response kit
Capacity A I; BC II 10 lb 30 lb Landline. Dial 9 for external. Absorption Capacity: 39 gal. Container: 55: gal Absorption Capacity: 15 gal. Container: 20 gal
TABLE 4: FIRE PUMP HOUSE - BIN Copy of Contingency Plan Handheld Radios Flashlights with Wands General Flashlights Lantern High visibility vests Rain Ponchos, Space Blankets
Quantity 1 8 2 4 1 8 Not specified
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Last Reviewed Date: 11/7/23
Form No.: F-00637 Emergency Equipment List & Inspection Form - EMS
Work Instruction: WI-006216 RCRA Contingency Plan
Revision No.: B
Page: 7 of 8
TABLE 5: LESS-THAN-90-DAY AREA 65-gallon overpack Pads and socks Phone
Quantity 1 Overpack full 1
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Last Reviewed Date: 11/7/23
Form No.: F-00637 Emergency Equipment List & Inspection Form - EMS
Work Instruction: WI-006216 RCRA Contingency Plan
Revision No.: B
Page: 8 of 8
Table 1 Date Completed Signature
Monthly Inspection Form
Inspection Dates / Initials
Table 2
Table 3
Date Completed Signature
Date Completed Signature
Table 4 Date Completed Signature
Date:
Table:
Finding:
Findings
*Inspections documented on another form
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 23 of 33
Appendix 4.1.5.1 - Chemical Line Tank Concentrations
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Coxsackie, New York
Last Reviewed Date: 2/1/24
Revision No.: D
Chemical Line Tank Concentrations
First number in ID indicates value stream
Tank ID
1-1 3-1 4-1 4-7 5-2
1-5 3-5 5-6
Name Constituent Spec High Limit Unit
Alkaline Clean Oakite 61B 8
Titanium Nitric 60
Etch
Hydrofluoric
7.0
oz/gal
oz/gal. oz/gal.
Page: 24 of 33
Measure Concentration Nitric Concentration Hydrofluoric Concentration
4-3
Passivation
Nitric Acid
58
oz/gal.
Acid Concentration
4-4 Aluminum Etch Oakite 160 5 oz/gal Concentration
4-6
Desmut
Nitric Acid
57
oz/gal
Acid Concentration
Bonderite* C- 14.0
oz/gal
Nitric Acid Concentration
4-9 Deoxidizer IC 6MU (Turco 1.1 oz/gal Turco Concentration
Deoxidizer)
0.4
mils/hr/side.
Etch Rate
4-10
Conversion 2.25 Alodine* 600 Coat 2
oz/gal pH
Alodine Concentration pH
4-12
1.2
Conversion Coat
Alodine* 1200
1.8
1-3, 3-3, & 5-4
Molten Salt Bath
(Caustic)
ALKO-N
*Bonderite = Alodine
oz/gal pH
Alodine Concentration pH
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 27 of 33
Appendix 7.3 - Supporting Personnel
(2 copies)
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Coxsackie, New York
Last Reviewed Date: 10/24/23
Revision No.: D
Page: 28 of 33
Immediately Emergency Response Supporting Personnel for Emergency Coordinator
# DESIGNATION
DUTIES
FIRST SHIFT (DEPARTMENT)
1 Assistant Emergency For off 2nd shift, 3rd shift, weekends, during an event, select personnel and direct
Not Applicable
Coordinator
them to perform actions 2 - 7 below
2 Emergency
Retrieve the emergency coordinator bin at the Pump House, the spill control
Maintenance
coordinator support equipment (without the intent to respond to spills), assist with head count, etc.
retrieval
3 Radio distribution
Distribute hand held radios to the Emergency Coordinator or designee, each gate
Maintenance
and muster point
4 Front gate emergency Personnel stationed at front gate directing emergency vehicle traffic
Engineering
vehicle guide
5 Back gate emergency
vehicle guide
6 Front gate incoming Personnel stationed at front gate directing incoming shift vehicle and personnel
Human resources (primary)
shift vehicle guide
traffic to either:
or Finance
7 Back gate incoming 1) Go home for actual events
shift vehicle guide
2) Where to park in the event of a drill or possible false alarm
8 Non-responding
Support the on-scene emergency coordinator either in person or via telephone As listed
emergency
including:
coordinators
1) Immediately, contact the:
a) Safety Manager b) Performance Center Director c) Maintenance Team Lead
2) Once the event is stabilized, via email, alert the other managers to the event including:
a) Value Stream Managers b) Program Managers
Coxsackie, New York
Last Reviewed Date: 10/24/23
c) Quality Manager d) Engineering Manager e) Human Resources f) Controller
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 29 of 33
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 17 of 33
Appendix 2-1)a) - Shelter In Place (Tornado) (WI-00242)
Coxsackie, New York Last Reviewed Date: 3/25/24
Work Instruction.: WI-00242 Shelter In Place (Tornado Shelter) - EMS
Revision No.: C
Page: 1 of 3
1. Purpose
The purpose of this work instruction is to provide instruction for a shelter-in-place event.
2. Scope
This work instruction applies to Ducommun AeroStructures New York, LLC, (DAS NY) personnel at 171 Stacey Road, Coxsackie, New York.
3. Responsibilities
3.1. Safety Manager: Revise and maintain this work instruction. 3.2. Supervisors: Enforce this work instruction 3.3. All Employees: Follow this work instruction
4. Definitions
4.1. [Reserved]
5. References
5.1. WI-00237 - RCRA Contingency Plan - EMS
6. Procedure/Policy
7. The Safety Manager or an emergency coordinator in their absence will: 7.1. Monitor weather conditions 7.2. During a Tornado Watch, will listen to a weather radio 7.3. For severe weather including a tornado warning, make an announcement to seek shelter will be made over the Public Address System and using the Bullhorn located in the Maintenance Office. If the power is out, this announcement can be made throughout the plant using the Bullhorn .
8. Employees will: 8.1. Go to an interior room. There are several areas designated with signage (see Figure 1) as "Severe Weather Shelter Areas". 8.1.1. See attached F-00646 Site Safety Map - EMS for Shelter in Place Areas identified in red.
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York Last Reviewed Date: 3/25/24
Work Instruction.: WI-00242 Shelter In Place (Tornado Shelter) - EMS
Revision No.: C
Page: 2 of 3
8.1.2. Personnel that report to the following managers will seek shelter in the indicated locations. See Table 1.
8.2. Do not go near windows, doors or exterior walls. 8.3. Exit to these areas in an orderly manner. 8.4. Remain at the Shelter in Place until dismissed. 9. When the instructions to seek shelter is announced, the Manager or their step up will: 9.1. Provide access to their designated shelter areas for employees who do not have badge access. 9.2. Once inside the safe shelter conduct a head count to make sure all employees are present or
accounted for. 10. Customers, Vendors, and Visitors are the responsibility of their hosts and need to be accounted for. 11. First Responders will bring bags if safe to do so. 12. The Safety Manager or an emergency coordinator will check with each Manager/Team Leader to
tally a correct total facility headcount that has been made on the 1st Shift. 13. Off Shift Managers, supervisors and team leads will do this check on 2nd and 3rd Shifts. 14. Once the head count has been confirmed and it is determined to be safe, all employees will be
informed to return to their work areas.
Figure 1
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York Last Reviewed Date: 3/25/24
Work Instruction.: WI-00242 Shelter In Place (Tornado Shelter) - EMS
Revision No.: C
Page: 3 of 3
Department
VS1/VS2 VS3/Blank/S_R
VS4 VS5 Engineering Quality Maintenance Purchasing HR Finance IT Program Mgmt Program Mgmt Program Mgmt GM
# Personnel
23 33 23 21 19 19 4 4 3 2 2 2 2 2 1
Table 1
Location
Front Women's/Men's Restroom Hallway to Parking Lot C
Men's Room in Front of VS1 DCC
Maintenance Front Office Front Women's/Men's Restroom
Maintenance Front Office Hallway to Parking Lot C Hallway to Parking Lot C Men's Room in Front of VS1 Men's Room in Front of VS1 Hallway to Parking Lot C Hallway to Parking Lot C Hallway to Parking Lot C Hallway to Parking Lot C
Second shift, third shift, weekend work - Hallway to Parking Lot C
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 18 of 33
Appendix 2-1)b) - Medical Emergency (WI-00251)
Coxsackie, New York Last Reviewed Date: 10/24/23
Work Instruction.: WI-00251 Employee Injury Procedure - EMS
Revision No.: B
Page: 1 of 3
1. Purpose
The purpose of this work instruction is to provide instruction in the event an employee is injured.
2. Scope
This work instruction applies to Ducommun AeroStructures New York, LLC, (DAS NY) personnel in Coxsackie, New York.
3. Responsibilities
3.1. Safety Manager: Revise and maintain this work instruction. 3.2. Supervisors: Enforce this work instruction 3.3. All Employees: Follow this work instruction
4. Definitions
4.1. [Reserved]
5. References
5.1. WI-00237 - RCRA Contingency Plan - EMS
6. Procedure/Policy
6.1. Have a First-Aid Responder or equally trained person treat the injured person. 6.2. Determine if the person needs off-site treatment. 6.3. Ask permission to transport.
6.3.1. LIFE THREATENING: A person can refuse off-site medical treatment on the grounds of Religious or other personal reasons. If there is a question on the severity of their injury, (requiring professional medical treatment), the Authorities must be called (9911) and they (the authorities) will need to make a final determination.
6.3.2. NON-LIFE THREATENING: A person can refuse off-site medical treatment on the grounds of Religious or other personal reasons. If not life threatening, but requiring professional medical treatment; have the injured employee fill out: Ducommun Form EHS 2.18.4 Medical Release Form. Make sure to have the two witnesses sign the Form!
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York Last Reviewed Date: 10/24/23
Work Instruction.: WI-00251 Employee Injury Procedure - EMS
Revision No.: B
Page: 2 of 3
6.4. Determine if they can be transported by private vehicle, or if an emergency vehicle needed.
6.5. Before transport in a private vehicle, make sure person is stable enough to travel.
6.5.1. If this is a Water-jet Injury, take a Medical Alert Card (located on Water-jet machine console) with you.
6.5.2. Talk calmly to the injured person, they are upset enough.
6.6. If transported in an Emergency Unit, the responding personnel will stabilize.
6.6.1. If this is a Water-jet Injury send a Medical Alert Card (located on Water-jet machine) with them.
6.6.2. The injured has the right to request a certain hospital. Columbia Memorial is the default.
6.7. While the person is coherent, make sure to get all possible information about the injury.
6.7.1. Sometimes as the injury becomes more painful a person may go into shock and forget details.
6.7.2. It's important to give the attending personnel all the details possible, including the Medical Alert Card if needed.
6.7.3. You are to either accompany or follow the employee as support and to make sure that they get treated with respect and have a clear understanding of what is going on as far as treatment goes.
6.8. Proceed to EmUrgentCare (Open 0900-2100) 11835 State Rt. 9W West Coxsackie (518) 7319000. Or to Columbia Memorial (Hudson) Emergency Room.
6.9. If the injured can fill out necessary paperwork, it can be done while waiting for admittance. Otherwise it may be done after the fact. Remember your activity in a calming demeanor will help alleviate a nerve racking situation for the injured.
6.10.
When treatment has been administered and restrictions are being discussed, Ducommun has a Light Duty/Accommodation Program for those injured on the job. The employee must have the explicit documentation from the Health Provider stating they are cleared to return to work and/or if they have restrictions. If the injured employee has restrictions, HR will need an
6.11. Employment Capabilities Form completed by the Health Provider stating what specifically those restrictions are. This form needs to be reviewed and approved by HR PRIOR to the employee returning to work. Unless the person is totally incapacitated, this option needs to be discussed.
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York Last Reviewed Date: 10/24/23
Work Instruction.: WI-00251 Employee Injury Procedure - EMS
Revision No.: B
Page: 3 of 3
6.11.1. Remember when talking on behalf of the employee to the care-giver; do not assume an authoritative attitude. This only provokes the Health Provider. Just make them aware that the injured can be accommodated when they return to work. (with the proper documentation from the Health Provider as noted above)
6.11.2. As a note, let the injured know that if they are written out of work, Worker's Comp does not pay till after 5 days. They would have to take sick time etc.
6.11.3. Make sure that the restrictions return to work etc., is all in writing. Verbal is no good.
6.12. Once the necessary treatment and paperwork have been completed, bring the injured back to the facility for a quick de-brief. After that, the injured can go home for the rest of their shift. Please make sure that they can drive or can get a ride.
6.13. Remember that above all, this employee is hurting and they need to be treated with compassion & understanding.
6.14. Once the person has been treated and is stable; notify all concerned parties and HR and EH&S of the incident and current status.
PRINTING NOTICE - Individuals are responsible for ensuring that they are using the governing version.
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 30 of 33
Appendix 9.4.5.2 - Agreement with Veolia
January 1, 2023
Mrs Mary McCoy Ducommun Aerostructures, Inc 171 Stacey Road Coxsackie, NY 12051
RE: Emergency Response Cost & Procedures:
Dear Mrs. McCoy:
Veolia Environmental Services (Veolia) has the technical personnel and equipment capabilities to respond to Ducommun Aerostructures, Inc. emergency response needs. All waste disposal requirements can be managed according to the environmental services agreement to be completed for these services.
Emergency Response Procedures In the event of a chemical spill or other emergency situation, it is important that pertinent information be accurately and efficiently relayed to VEOLIA personnel. Much time and money can be saved if the situation is assessed properly and the appropriate manpower and equipment are mobilized. The following steps should be taken when an employee is responding to a chemical spill/emergency and requests the services of VEOLIA.
1) If possible, identify the spilled chemical and quantity. Also note the location of the spill.
2) CALL VEOLIA AT 1-800-354-2382. Dial "1".
3) The information provided will be given to the "on-call" Veolia representative, who will initiate internal communications with Veolia operations personnel, and the response action will begin to develop. You will be contacted by a representative of Veolia with first response communications.
4) Once the level of response has been determined, the appropriate personnel and equipment will be mobilized. A subcontractor may be contacted to assist with the response.
Emergency response equipment that will be on-site when a field crew is picking up chemicals.
The following emergency response equipment is provided with each service vehicle at time of
Page 1 of 11
service: 85 gallon drum over pack Vermiculite
Personal Protective Equipment (tyveks, gloves, boots, respirators) ABC dry chemical fire extinguisher Fully equipped first aid kit including eye wash Drum opening tools, shovel, poly sheeting Empty containers pH paper to assess corrosivity Spare fuses, flashlights Reflective triangles Mobile phone
Spill equipment available, if necessary, through the Emergency Response Clean-up Team (Subcontractor)
Vacuum Truck Spill control trailer Special pumps and tools Large stock of absorbents (vermiculite, speedi-dry, booms, activated carbon, lime) Self-Contained Breathing Apparatus Earth excavation equipment and water-tight dump trailers
Emergency Response Costs
Annual Administrative Fee: $500.00
During normal business hours; Monday - Friday 8 am - 4 pm: $1,000.00 flat fee $115.00 per hour for a Field Supervisor $95.00 per hour for a Technician
After normal business hours; Monday - Friday 5 pm - 7:59 am: $1,750.00 flat fee $172.50 per hour for a Field Supervisor $142.50 per hour for a Technician
Sundays and Holidays: $2,250.00 flat fee $230.00 per hour for a Field Supervisor $190.00 per hour for a Technician
Rates for additional services, equipment, and supplies, should they be required, are listed below.
Page 2 of 11
Please return this quotation indicating your acceptance with your signature and purchase order number below.
We value the opportunity to service your environmental needs. If you have any questions or concerns, please contact me at (518) 332-5529.
Sincerely, Veolia Environmental Services
Megan Pellam
Megan Pellam Account Manager
Cc: Renee Spadaro, TSR, Veolia
ACCEPTED: Ducommun Aerostructures, Inc.
By: Title: EHS Manager Date: 5/23/23 Purchase Order No:
Page 3 of 11
2021
TIME AND MATERIALS RATES
EMERGENCY RESPONSE FEES & RATES: Annual Administrative Fee: $500.00 During normal business hours; Monday - Friday 8 am - 4 pm: $1,000.00 response fee After normal business hours; Monday - Friday 5 pm - 7:59 am: $1,750.00 response fee Sundays and Holidays: $2,250.00 response fee
Labor- North East
Section 1.1 Environmental Personnel/Administrative Administrative Assistant/Field Clerk Health & Safety Specialist Field Chemist Field Technician Truck Driver (Commercial License - Haz Mat) Equipment Operator Foreman Superintendent Response Manager Engineer Hydrogeologist Scientist Principal Oversight/Technical Oversight Disposal Coordinator Biohazard/Reactive/Explosive Technician Biohazard/Reactive/Explosive Supervisor Railcar Specialist Firefighter Section 1.2 Marine Personnel U.S. Coast Guard Licensed Captain Deckhand Marine Superintendent/Non-diving Supervisor Commercial Diving Supervisor
Regular Per Hour Overtime Per Hour Premium Per Hour
$48.75 $107.00
$77.50 $95.00 $70.00 $70.00 $70.00 $89.00 $115.00 $114.50 $114.50 $114.50 $145.75 $53.00 $116.75 $175.00 $79.50 $70.75
$145.75 $69.00
$145.75 $116.50
$73.25 $107.00 $116.25 $142.50 $105.00 $105.00 $105.00 $133.50 $174.50 $114.50 $114.50 $114.50 $114.50
$79.50 $175.25 $175.00 $119.25 $106.25
$218.75 $103.50 $218.50 $174.75
$97.50 $107.00 $155.00 $190.00 $140.00 $140.00 $140.00 $178.00 $190.00 $114.50 $114.50 $114.50 $114.50 $106.00 $233.50 $175.00 $159.00 $141.50
$291.50 $138.00 $291.50 $233.00
Page 4 of 11
Commercial Diver Commercial Dive Tender Remote Vehicle Operator Sonar Technician
Equipment
$99.00 $70.75 $126.00 $127.25
2.1 Other Services Spill Report Expert Witness Testimony Subcontract/Rental Equipment
2.2 Personal Protection and Safety Equipment
Level A Protection - Trelleborg Viking NFPA Suite Level A Protection or Equivalent Level B Protection w/Responder Level B Protection w CPF 1-2-3 Level B Protection w CPF 4 Level B Protection w Goretex Turnout Gear Level C Protection w/CPF 1-Proshield Level C Protection w/CPF 2 Level C Protection w/CPF 3 Level D Protection w/CPF 1-Proshield Cascade Manifold Breathing Air System w T Bottles Breathing Air Hose (50ft Section) Air Cascade Trailer Self Contained Breathing Apparatus (standby) Portable Eye Wash Rope Rescue kit (standby) Confined Space Entry Kit w/ Tripod Confined Space Entry OSHA Rope Kit Proximity Suits( W/SCBA) USCG Floatation Vest Nomex Suits Cold Weather Deck Suit CPF 1 Suits CPF 2 Suits CPF 3 Suits CPF 3 Suits, Expanded back CPF 4 Suits CPF 4 Suits-Encapsulated, expanded back Responder - Level B Responder - Level A EOD Suits ( Turn-out gear) Tyvek Suit Poly-coated Tyvek Suit Rain/Splash Gear PVC Acid Suit 2.3 Transport Equipment Automobile Pick-up Truck Response Managers Pick-up Truck
(minimum $355.00)
$148.50 $106.25 $189.00 $190.75
$198.00 $141.50 $252.00 $254.50
$114.00
Hour
2 times list rates
cost plus 20%
$2,500.00 $1,200.00
$975.00 $550.00 $600.00 $500.00
72.00 $136.00 $175.00
$47.00 $84.50 $17.50 $360.00 $190.00 $36.00 $51.50 $154.00
$1.00 $825.00
$21.00 $24.75 $51.50 $16.75 $47.25 $79.25 $146.25 $79.25 $156.25 $680.00 $1,240.00 $500.00 $15.50 $31.00 $25.75 $31.00
$55.25 $92.75 $190.00
Change Change Change man/day man/day man/day man/day man/day man/day man/day man/day sect/day
Day Day Day Day Day Foot man/day Ea/day Day Day Each Each Each Each Each Each Each each Day each each set set
day day day
Page 5 of 11
Four Wheel Drive Vehicle Utility Truck (1 ton payload) Utility Truck (1 ton payload) w Lift Gate / Box Van Stake Bed Truck (5 ton payload) / Box Van Emergency Response Trailer (14 to 16 ft.) Emergency Response Trailer (18 to 25 ft.) Emergency Response Trailer ( > 25 ft) ER Command Center Trailer Semi-Tractor Rolloff Trailer Rolloff Truck Rolloff Box (20 yd) Rolloff Drop Charge Dump Truck Dump Trailer Flat Bed Trailer (40 ft) Low Boy Office Trailer Equipment Trailer ( Skidsteer) Utility Trailer (enclosed) (14 - 18) Semi-van Trailer (40 ft.) Tanker Trailer (non vacuum) (7,000 gal.) Tanker Trailer (non vacuum) (5,000 gal.) Sludge Tanker Trailer 2.4 Vacuum Equipment Vacuum Trailer Non-regulated waste, Hourly Vacuum Trailer Regulated waste, Hourly Straight Truck < 3,500 gallon capacity Non-regulated waste, Hourly Straight Truck < 3,500 gallon capacity Regulated waste, Hourly Straight Truck > 3,500 gallon capacity Non-regulated waste, Hourly Straight Truck > 3,500 gallon capacity Regulated waste, Hourly High Velocity Vacuum Truck (ie. supersucker, guzzler, hivac) Cyclone Separator for High Velocity Vacuum Truck Vacuum Unit (800 gal.; w/50 ft hose) (mini-vacuum) Vacuum Box Vacuum Box Drop Portable HEPA Vacuum units w/o Filter Mercury HEPA Vacuum w/o Filter HEPA Drum Vacuum w/o Filter Mercury HEPA Vacuum Filter HEPA Vacuum Filter Explosive Proof HEPA Vacuum Drum Vacuum (Air) Tornado Drum Vac (Electric) Utility Vacuum Vapor Scrubber Unit Pneumatic Vacuum Transfer Trailer 2.5 Waste Excavation and Handling Equipment Rubber-Tired Loader (CAT 930 or Equivalent) Crawler Dozer (CAT D-5 or Equivalent) Trackhoe Excavator (CAT 330 or Equiv.) Trackhoe Excavator (CAT 320 or Equiv.) Backhoe (Case 580 or Equivalent) Fork Truck Bobcat(Skidsteer) Skidsteer Sweeper
$136.75 $114.50 $153.75 $300.00 $224.00 $308.00 $325.00 $1,030.00
$48.00 $33.00 $43.00 $12.50 $250.00 $37.00 $129.00 $52.00 $206.00 $57.00 $52.00 $52.00 $62.00 $33.00 $21.50 $20.50
day day day day day day day day hour hour hour day each hour day day day day day day day day day day
$57.00
hr
$72.00
hr
$76.50
hr
$98.50
hr
$81.50
hr
$104.00
hr
$98.00
hr
$31.00
hr
$46.00
hr
$52.00
day
$250.00
each
$77.00
day
$360.00
day
$221.00
day
Replacement cost & 20%
$135.00
each
$155.00
day
$62.00
day
$155.00
day
$35.00
day
$1,020.00
day
$258.00
hr
$546.00
day
$655.00
day
$2000.00
day
$1200.00
day
$500.00
day
$329.00
day
$400.00
day
$82.00
day
Page 6 of 11
2.6 Mobile Treatment and Recovery Equipment Hydraulic Dredge Holding Tank (> 5,000 gal.) (5 day Minimum, plus mob/demob) Frac Tank (21,000 gal) (5 day Minimum plus mob/demob) Poly Storage Tanks (<500 gals) ( 5 day min) Poly Storage Tanks (>500- 5000 gals) ( 5 day min) Bag Filter Unit (Filters extra) Mobile oil/water separator/air stripper trailer
2.7 Pumping Equipment 1",2",3" Air Diaphragm Pump 2" Hydraulic chemical pump w/Power Pack 2" Submersible Electric Pump 3" and 4" Trash Pump 3" Submersible Electric Pump 4" Air Diaphragm Pump 4" Electric Centrifugal Sludge Pump 4" Hydraulic Sludge Pump w/ Power Pack 4" Submersible Electric Pump 6" Hydraulic Sludge High Head Pump w/Power Pack 6" Hydraulic Sludge Pump w/ Power Pack 6" Trash Pump 8" Hydraulic Sludge Pump w/ Power Pack 10" Trash Pump Utility pump / 12 Volt Transfer Pump Explosion proof electric Drum Pump Drum siphon pump
Corken Compressor
Blackmer Pump w Power Pack Diaphragm Pump Rebuilding Kit 1", 2", 3" Diaphragm Pump Rebuilding Kit 4" 2.8 HOSE Fittings Charge Suction 2" (20 ft section) (Non Chem) Suction 3" (20 ft section) (Non Chem) Suction 4" (20 ft section) (Non Chem) Suction 6" (20 ft section) (Non Chem) Fire 1.5" (50 ft section) Fire 2.5" (50 ft section) Fire 3.0" (50 ft section) 2" Solvent/petroleum 2" Acid/caustic 2" Disposable Flex hose 4"- 6" Disposable Flex hose 8" Disposable Flex hose 1", 2", 3" Chemical hose w/appropriate fittings 2", 3" Discharge (100' section) (non-chemical) additional Hydraulic hose (50' section) additional 2.9 Industrial Services Equipment Sewer Cleaning Truck / Jetter Water Truck 85 gpm, 2000 psi Intrinsicaly Safe Sewer Inspection Unit Non-Intrinsicaly Safe Sewer Inspection Unit Skid Mounted Jetter Water Unit(240 gpm, 2500psi) Sewer Jetter Water Truck 85 gpm,1500 psi Comb Jetter/Vac Truck (65 gpm, 3000 cfm) Comb Jetter/Vac Truck (85 gpm, 3500 cfm) Comb Jetter/Vac Truck (138 gpm, 4500 cfm)
Priced per project
$52.00
day
$82.00
day
$16.00
day
$41.00
day
$28.00
day
$1,290.00
day
$155.00 $360.00
$98.00 $206.00 $165.00 $258.00 $128.00 $465.00 $232.00 $1,030.00 $1,030.00 $309.00 $1,545.00 $515.00
$52.00 $155.00
$16.00
$1,000.00
$450.00 $360.00 $515.00
day day day day day day day day day day day day day day day day each day Plus Rebuild day ea ea
$320.00 $10.50 $16.00 $22.00 $32.00 $27.00 $37.00 $43.00
$1.00 ft or $2.50 ft or
$30.00 $1.50 $2.00 $3.25
$37.00 $52.00
Per transfer day day day day day day day
cost & 20% cost & 20%
100' roll foot/day foot/day foot/day
day ft/day
$90.00
hr
$165.00
hr
$110.00
hr
$143.00
hr
$55.00
hr
$95.00
hr
$111.00
hr
$132.50
hr
Page 7 of 11
Easement Reel w/ Trailer Pump Trailer/Heat Exchanger 2.10 Oil Spill Equipment Drum Skimmer-Hydraulic w/Power Pack Drum Skimmer-Pneumatic w/o Power Pack Skim-Pac 2200 Weir Skimmer 2" Weir Skimmer Boom Boat - 18'-20' Boom Boat - 24' Jon Boat (12-14'; with motor) Jon Boat (12 - 14' without motor) Containment Boom - 18" Containment Boom - 18" (standby) Containment Boom - 36" Containment Boom - 36" (standby) Boom Anchor System Boom Lights USCG Floatation Vests VHF-FM Hand Held Radio Floto-pump Oil Blower, Gas Powered 2.11 Marine Specialty Equipment Shallow Air Package Deep Air Package (Single Chamber) Remote Operated Vehicle - Phantom HD2 Digital Side Scan Sonar Resonance Multi-Beam Sonar Sector Scanning Sonar Differential Global Positioning System 26ft Portable Survey Boat 28ft Portable Tug - 275hp Diesel Inboard
25ft x 35ft x 2.5ft Self-propelled Portable Crane Barge W/Spuds and 8,000lb Hydraulic Crane 40ft x 50ft x 4ft Portable Barge W/spuds
2.12 Compression Equipment
Diesel Air Compressor < 300 cfm Air Compressor, < 300 cfm Hot Water Press. Wash Unit (2,500 - 3,000 PSI) Pressure Wash Unit (2,500 - 3,000 PSI) Pressure Wash Unit (1,000 - 1,500 PSI) Air Blower/Air Evacuator Waterblaster (10,000 PSI) Waterblaster (20,000 PSI) Air Hose (3/4", 50' section) Graco Wash Unit 2.13 Sampling and Analytical Equipment Photoionization Detector (PID Meter) O2/LEL/Toxic Meter (Quad Gas Monitor) Radiation Meter Laser temperature meter Jerome Mercury Monitor VM 3000 Mercury Monitor / Lumex Field Characterization Kit Megger Meter GPS Unit UHRA First Defender
$40.00
hr
$230.00
hr
$740.00 $432.00 $155.00 $103.00 $464.00 $567.00 $110.00
$75.00 $2.00 $1.00 $3.50 $1.75
$77.00 $21.00 $21.00 $21.00 $82.00 $51.00
day day day day day day day day ft/day ft/day-Stby ft/day ft/day-Stby day each day Ea/day day day
$260.00
day
$950.00
day
$1,236.00
day
$650.00
day
$1,545.00
day
$310.00
day
$103.00
day
$950.00
day
$950.00
day
$1,500.00
day
$750.00
day
$305.00 $191.00 $220.00 $154.00 $103.00
$26.00 66.00
$131.00 $16.00
$103.00
day day day day day day
hr hr sect/day day
$155.00 $103.00 $103.00
$36.00 $360.00 $515.00
$30.00 $52.00 $25.00 $500.00
day day day day day day Per Sample day day day
Page 8 of 11
Cyanide Meter Chlorine Meter pH Paper BTA Guardian Analyzer Ultraviolet Germicidal Lighting Draeger Air Monitoring Pump w/o tubes Draeger Tubes Asbestos Monitoring Pump Personal Air Sampling Pump Clor-n-oil test kit Clor-n-soil test kit Rocket Fuel Test Kit X Spray Sample Kit Smart II Biological Detection Tickets BTA Test Biological Test Strip (Agent Specific) Wipe Sample Kit Coliwasa Glass Sampling Tubes (4') Sample Thief, 75 ml Split Barrel Hand Sampler Hand Auger 2.14 Specialized Tools and Equipment Drum Cart Glove Box Tank Tap Machine Non-Sparking Tool Set Pressurized Gas Overpack Containers Plug & Patch kit Tank Truck Rollover Trans Kit/Hot tap kit Betz Valve-Tank Truck Rollover Forklift Drum Holder Evacuation Fan HEPA Negative Air Machine (w/o Filter replacement)
Portable Flare Stack 2.15 Miscellaneous Equipment
Generator (5 kW) Generator (15 kW) Generator (100 kW - 200 kW) Portable Light Set Intrinsically Safe Portable Lights, Portable Hammer Drill Air Hammer (bits extra) Chop Saw (Concrete/Metal) (Portable) (1 blade incl.) Cutting Torch (Oxygen/Acetylene Not Included) Hand tool allowance / Small tools Portable Welder Pneumatic Pipe Plugs Phone - Mobile SAT Phone Field Printer/Copier Field Computer Photo Documentation Chain Saw Portable Heater (Salamander) 3.1 Containers 2-5 gal. Plastic Pails
$103.00
day
$103.00
day
$8.00
roll
$675.00
day
$103.00
day
$16.00
day
$10.00
each
$26.00
day
$33.00
day
$21.00
each
$26.00
each
$4.50 Each sample
$3.33 Each sample
$113.00
each
$150-500
each
$77.00
each
$23.00
each
$3.25
each
$3.25
each
$41.00
day
$16.00
day
$21.00
day
$100.00
day
Priced per project
$103.00
day
$825.00
day
$160.00
each
$1,030.00
day
$258.00
day
$16.00
day
$77.00
day
$155.00
day
$206.00
day
$82.00
day
$180.00
day
$360.00
day
$30.00
day
$103.00
day
$52.00
day
$51.00
day
$51.00
day
$41.00
day
$67.00
day
$155.00
day
$103.00
day
$35.00
day
$80.00
Call
$31.00
day
$21.00
day
$30.00
day
$51.00
day
$51.00
day
$14.00
each
Page 9 of 11
5 gal. metal drum 14 Gallon Plastic Drum 20 gal Fiber Drum 30 gal. Plastic Drums 30 gal. Fiber Drums 55 Gallon Metal Open Top Drum (Reconditioned) 55 Gallon Metal Closed Top Drum 55 gal. Plastic Drums 85 gal. Overpack Drums (Metal) 95 gal. Overpack Drums (Plastic) Poison pack, 12A10 Asbestos Bag / Drum Liner 6 ml Cubic Yard Box - Gaylord IBC Container Tote (Reconditioned) 3.2 Packaging Drum Liner (Heavy Duty Corragated) Shrink Wrap Rolloff Box Liner (20 yd) 3.3 Gloves 4H Chemical Gloves Acid Gloves.(Milled Neoprene) Cloth Gloves Gloves, Winter Poly Liners Leather Work Gloves Nitrile Interior Gloves (NDEX) (50 pair/box) PVA Gloves PVC Gloves Solvex Gloves Viton Gloves 3.4 Boots Neoprene Boots PVC/Latex Disposable Boots (Nuke boots) Rubber/PVC Boots/Beta 3.5 Respirator Cartridges Respirator Cartridges - GME Respirator Cartridges - GME - P100 Respirator Cartridges - P100 Respirator Cartridges - Mersorb Respirator Cartridges - Mersorb - P100 3.6 Face/Eye Protection Face Shields Goggles Safety Glasses Welding Goggles 3.7 Cleaning Supplies Alconox (4lb box) Brute Force (1 gal) Mercury Decontamination Solution (HGX) Micro Blaze (5 gal) Micro Blaze Application Kit Paper towels (reinforced) (box) PCB Decontamination Solution (10 gal) Simple Green Trash Bags (100/box) Decon Pools (100 gals)
$16.00 $46.00 $21.00 $48.00 $32.00 $53.25 $33.00 $75.25 $175.00 $206.00 $36.00
$2.50 $115.00 $180.00
$18.00 $26.00 $65.00
$6.50 $16.00
$2.25 $4.25 $6.00 $13.50 $36.00 $8.00 $15.50 $145.00
$26.00 $6.75
$125.00
$15.00 $23.00 $10.00 $26.00 $41.00
$8.50 $4.25 $6.25 $20.00
$26.00 $17.00 $10.50 $250.00 $315.00 $13.50 $270.00 $18.00
$5.25 $515.00
each each each each each each each each each each each each each each
each roll
each
pair pair pair pair pair box pair pair pair pair
pair pair pair
pair pair pair pair pair
each each
pair each
each each pound each
day box each Gal. box each
Page 10 of 11
DIRS BioChem Decon Kit 3.8 Sorbents/Neutralizing Agents
Citric Acid Gap Seal Gypsum Oil dry / Floor dry / Grand sorb Sand bags Soda Ash Super Absorbent Powder (S.A.P.) (25gal pail) Vermiculite Absorbent Pads (17" X 19") Absorbent Boom (8" x 10') Absorbent roll (4'x150'/ Roll) 3.9 Miscellaneous Barrier Tape/Hazard Tape Chest Waders
Fence Post
Waste Manifests Drum Labels Plastic Snow Fence (50 ft) Poly Rope (3/8") Poly Rope, Nylon (1/2') Sample Jar (4oz) Sample Jars (1 qt.) Disposable Bailer Duct Tape Visqueen, 6ml, 20" x 100' Visqueen, 6ml, 40" x 100'
$925.00
$82.00 $21.00 $16.00 $16.00
$2.25 $36.00 $47.00 $20.00 $95.00 $65.00 $125.00
$21.00 $77.00
$5.25 $5.25 $1.00 $36.00 $0.20 $0.30 $3.25 $3.25 $10.00 $6.75 $115.00 $270.00
kit
bag each
bag bag each bag each bag Bale each roll
roll pair each each each roll foot
ft each each each
roll roll roll
Page 11 of 11
!
PURCHASE ORDER
171 STACEY ROAD COXSACKIE, NY 12051 PHONE (518) 731-2791 . FAX (518) 731-6333
P.O. # FPU100957
Page
1
Change Sequence Supplier : S47031
NCEhWanPgUe RRCeHasAoSnE ORDER
Order Date: 06-03-23
Buyer
: Linda J Barley
Phone
: 518-731-4657 / 518-731-6333
Permit#
Email
: LBarley@ducommun.com
Delivery Address
Ducommun Aerostructures
171 Stacey Road
VEOLIA NORTH AMERICA
COXSACKIE
126 MORRIS RD.
New York 12051
SCHENECTADY
New York 12304
518-332-5529
Ref/Contact : Veolia ER standby a
Request By : FPR020865/MCCOY
Megan Pellam
Ref : see attached
BILL TO: DUCOMMUN AEROSTRUCTURES,
ATTN: ACCOUNTS PAYABLE, 23301 WILMINGTON AVE, CARSON, CA 90745-6209
EMAIL FOR INVOICES ONLY : Accountspayable@ducommun.com
If Ducommun pays for the freight cost per existing Purchase Order OR Agreement, AND has not specified a carrier on this order, for Less Than Truckload (LTL) or International Shipments, please contact your Ducommun location where the Purchase Order / Agreement originated and communicate the following: 1) Dimensions of shipment 2) Weight of the shipment 3) Class of Shipment and Description 4) When it is ready to be picked up 5) Your hours of operations for pick-up of shipment.
A Ducommun contact will direct you with instructions. Please note, if the vendor of the Purchase Order or Agreement ships the product without consulting Ducommun, Ducommun has the right to reduce the invoice amount by the freight amount included on the vendor invoice.
Ship Via On Site Service SBA Information :
Terms of Payment 75 Net 75 Days Terms of Delivery SHP SHIPPING POINT
Line
Quantity Unit Item
Seq
Part Rev Description
10
1.0000 EA
SAFETY RACK CLIPS
0
SAFETY SUPPLIES AND SERVICES SAFETY SUPPLIES
Tax Account #
Due on Dock Date
N 531100
06/08/2023
Work Center F984
Unit Price 500.0000
Extension 500.0000
Emergency Response Cost & Procedures:
06/03/2023 12:16 pm
!
171 STACEY ROAD COXSACKIE, NY 12051 PHONE (518) 731-2791 . FAX (518) 731-6333
Change Sequence
NCEhaWngPeURReCaHsAonSE ORDER
PURCHASE ORDER
P.O. # FPU100957
Page
2
Line
Quantity Unit Item
Seq
Part Rev Description
Tax Account #
Due on Dock Date
Unit Price
Extension
Veolia Environmental Services (Veolia) has the technical personnel and equipment capabilities to respond to Ducommun Aerostructures, Inc. emergency response needs. All waste disposal requirements can be managed according to the environmental services agreement to be completed for these services.
Emergency Response Procedures In the event of a chemical spill or other emergency situation, it is important that pertinent information be accurately and efficiently relayed to VEOLIA personnel. Much time and money can be saved if the situation is assessed properly and the appropriate manpower and equipment are mobilized. The following steps should be taken when an employee is responding to a chemical spill/emergency and requests the services of VEOLIA.
1) If possible, identify the spilled chemical and quantity. Also note the location of the spill.
2) CALL VEOLIA AT 1-800-354-2382. Dial "1".
3) The information provided will be given to the "on-call" Veolia representative, who will initiate internal communications with Veolia operations personnel, and the response action will begin to develop. You will be contacted by a representative of Veolia with first response communications.
4) Once the level of response has been determined, the appropriate personnel and equipment will be mobilized. A subcontractor may be contacted to assist with the response.
Emergency response equipment that will be on-site when a field crew is picking upchemicals.
The following emergency response equipment is provided with each service vehicle at time of service: 85 gallon drum over pack Vermiculite
Personal Protective Equipment (tyveks, gloves, boots, respirators)
06/03/2023 12:16 pm
!
171 STACEY ROAD COXSACKIE, NY 12051 PHONE (518) 731-2791 . FAX (518) 731-6333
Change Sequence
NChEaWngPeURReCaHsoAnSE ORDER
PURCHASE ORDER
P.O. # FPU100957
Page
3
Line
Quantity Unit Item
Seq
Part Rev Description
Tax Account #
Due on Dock Date
Unit Price
Extension
ABC dry chemical fire extinguisher Fully equipped first aid kit including eye wash Drum opening tools, shovel, poly sheeting Empty containers pH paper to assess corrosivity Spare fuses, flashlights Reflective triangles Mobile phone
Spill equipment available, if necessary, through the Emergency Response Clean-up Team (Subcontractor)
Vacuum Truck Spill control trailer Special pumps and tools Large stock of absorbents (vermiculite, speedi-dry, booms, activated carbon, lime) Self-Contained Breathing Apparatus Earth excavation equipment and water-tight dump trailers
Emergency Response Costs
Annual Administrative Fee: $500.00
During normal business hours; Monday - Friday 8 am - 4 pm: 1,000.00 flat fee 115.00 per hour for a Field Supervisor 95.00 per hour for a Technician
After normal business hours; Monday - Friday 5 pm - 7:59 am: 1,750.00 flat fee 172.50 per hour for a Field Supervisor 142.50 per hour for a Technician
Sundays and Holidays: 2,250.00 flat fee 230.00 per hour for a Field Supervisor 190.00 per hour for a Technician
06/03/2023 12:16 pm
!
171 STACEY ROAD COXSACKIE, NY 12051 PHONE (518) 731-2791 . FAX (518) 731-6333
Change Sequence
NChEaWngPeURReCaHsoAnSE ORDER
PURCHASE ORDER
P.O. # FPU100957
Page
4
Line
Quantity Unit Item
Seq
Part Rev Description
Tax Account #
Due on Dock Date
Unit Price
Extension
Goods
$
0.000
Costs 500.00
Tax
$
0.00
P.O. Total Signature
$ 500.000 !
06/03/2023 12:16 pm
!
171 STACEY ROAD COXSACKIE, NY 12051 PHONE (518) 731-2791 . FAX (518) 731-6333
Change Sequence
NCEhWangPeURReCaHsAoSnE ORDER
PURCHASE ORDER
P.O. # FPU100957
Page
5
Line
Quantity Unit Item
Seq
Part Rev Description
Tax Account #
Due on Dock Date
Unit Price
Extension
Purchase Order Number and Line Number must appear on all shipping containers, packing lists, invoices, bills of lading & correspondence. Packing Lists Must Accompany Each Shipment. This Purchase Order is subject to Ducommun's terms and conditions dated 11/05/2020 as posted at http://www.ducommun.com/pdf/DCO_TC.pdf or you can request a copy from your buyer.Acceptance of the offer represented by this order is expressly limited to such terms & conditions without change or addition. The Seller's acknowledgment of this Order, commencement of work on the goods ordered or shipment of such goods, whichever occurs first, shall be deemed Seller's acceptance of the Order. This is the entire contract and any other terms or conditions proposed by Seller's acknowledgement shall not be binding upon Buyer. If applicable to the Order, please see http://www.ducommun.com/dco/supplierlinks.aspx or your buyer for a list of definition of Quality Clauses. You, the supplier, are required to flow down (all) purchase order requirements to your suppliers and they to their suppliers.
Supplier Acknowledgement Printed Name, Signature and Date
06/03/2023 12:16 pm
Coxsackie, New York
Last Reviewed Date: 2/1/24
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Revision No.: D
Page: 25 of 33
Appendix 4.2 - Safety Data Sheets - to be posted at the end of the plan
SAFETY DATA SHEET
Issuing Date 30-Jul-2014
Revision Date 1-May-2015
#290
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING
GHS product identifier Product Name
Kolene Alko-NTM
UN-Number
UN1759
Recommended use of the chemical and restrictions on use
Recommended Use
In its molten state to condition surface scales and remove lubricants primarily from titanium components
Uses advised against
Avoid contact with aluminum, brass, bronze
Supplier's details
Supplier Address Kolene Corporation 12890 Westwood St. Detroit, MI TEL: 313 273-9220
Emergency telephone number
Emergency Telephone Number
CHEMTREC: 1-800-424-9300 Kolene Corporation
(24 hour response) 313 273-9220
2. HAZARDS IDENTIFICATION
Classification
Acute Oral Toxicity Skin Corrosion/Irritation Serious Eye Damage/Eye Irritation
Category 4 Category 1 Category 1
Subcategory 1A
GHS Label elements, including precautionary statements
Emergency Overview
Signal Word
Danger
Hazard Statements
Harmful if swallowed
Causes severe skin burns and eye damage
Appearance Colorless to white
Physical State Solid bead/flake.
Odor Odorless
2. HAZARDS IDENTIFICATION continued
_____________________________________________________________________________________________ Page 1 / 9
Kolene Alko-NTM
May 1 2015
_____________________________________________________________________________________________
Precautionary Statements
Prevention Wash face, hands and any exposed skin thoroughly after handling. Do not eat, drink or smoke when using this product. Do not breathe dust/fume/gas/mist/vapors/spray. Wear protective gloves/protective clothing/eye protection/face protection.
General Advice Immediately call a POISON CENTER or doctor/physician. Specific treatment (see supplemental first aid instructions on this label)
Eyes IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/physician.
Skin IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. Wash contaminated clothing before reuse.
Inhalation IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
Ingestion IF SWALLOWED: Call a POISON CENTER or doctor/physician if you feel unwell. Rinse mouth. Do NOT induce vomiting.
Storage Store locked up.
Disposal Dispose of contents/container to an approved waste disposal plant.
Hazard Not Otherwise Classified (HNOC)
Not applicable
Other information 0% of the mixture consists of ingredient(s) of unknown toxicity.
3. COMPOSITION/INFORMATION ON INGREDIENTS
Chemical Name Potassium hydroxide
Potassium nitrate
CAS-No 1310-58-3 7757-79-1
Weight % 75-85 15-25
* Where displayed, ranges reflect concentration variation from one product to another
Trade secret * *
4. FIRST AID MEASURES
_____________________________________________________________________________________________ Page 2 / 9
Kolene Alko-NTM
May 1 2015
_____________________________________________________________________________________________
Description of necessary first-aid measures
Eye Contact Skin Contact
Immediately flush with plenty of water. After initial flushing, remove any contact lenses and continue flushing for at least 15 minutes. Consult a physician.
Wash off immediately with soap and plenty of water removing all contaminated clothes and shoes. If symptoms persist, call a physician.
Inhalation Move to fresh air. If breathing is difficult, give oxygen. If symptoms persist, call a physician.
Ingestion Drink plenty of water. Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Immediate medical attention is required.
Most important symptoms/effects, acute and delayed
Most Important Symptoms/Effects No information available.
Indication of immediate medical attention and special treatment needed, if necessary
Notes to Physician Treat symptomatically.
5. FIRE-FIGHTING MEASURES
! SPECIAL FIREFIGHTING WARNING !
DO NOT USE WATER IN THE VICINITY OF THIS PRODUCT WHEN IN ITS MOLTEN STATE!
Introduction of water or other volatile liquids on or in the molten salt bath may result in violent expulsion of the molten salt.
Suitable Extinguishing Media
This material is basically nonflammable and will not burn.
Use water, CO2, or dry chemical extinguishers to fight fires in storage areas only.
Unsuitable Extinguishing Media
See warnings above.
Specific Hazards Arising from the Chemical
All water solutions of this product will be highly alkaline.
Explosion Data Sensitivity to Mechanical Impact Sensitivity to Static Discharge
None. None.
Protective Equipment and Precautions for Firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
North American Emergency Response Guide No. 154.
6. ACCIDENTAL RELEASE MEASURES
_____________________________________________________________________________________________ Page 3 / 9
Kolene Alko-NTM
May 1 2015
_____________________________________________________________________________________________
Personal precautions, protective equipment and
emergency procedures
Personal Precautions Environmental Precautions
Evacuate personnel to safe areas. Ensure adequate ventilation. In case of insufficient ventilation wear suitable respiratory equipment. Avoid contact with skin, eyes and clothing. Use personal protective equipment.
Environmental Precautions See Section 12 for additional Ecological Information.
Methods and materials for containment and cleaning up
Methods for Containment Methods for Cleaning Up
Prevent further leakage or spillage if safe to do so.
In case of accidental spill or leak, material should be shoveled up into steel containers for proper disposal. After cleaning, flush away traces with water.
7. HANDLING AND STORAGE
Precautions for safe handling
Handling Handle in accordance with good industrial hygiene and safety practice. In case of insufficient ventilation, wear suitable respiratory equipment. Avoid contact with skin, eyes and clothing. Wear personal protective equipment. Do not eat, drink or smoke when using this product. Do not take internally. Wash thoroughly after handling.
Conditions for safe storage, including any incompatibilities
Storage Incompatible Products
Keep containers tightly closed in a dry, cool and well-ventilated place. Reducing agents. Acids. Water. Organic material. Magnesium. Tin. Zinc. Aluminium.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Control parameters Exposure Guidelines
Chemical Name Potassium hydroxide 1310-58-3
Appropriate engineering controls
ACGIH TLV Ceiling: 2 mg/m3
OSHA PEL (vacated) Ceiling: 2 mg/m3
NIOSH IDLH Ceiling: 2 mg/m3
Engineering Measures
Showers Eyewash stations Ventilation systems
Individual protection measures, such as personal protective equipment
Eye/Face Protection
Skin and Body Protection
Face-shield. Goggles.
Respiratory Protection
Manufacturer recommended gloves for handling corrosive materials should be worn.
Impervious clothing. Safety shoes. Rubber boots.
No protective equipment is needed under normal use conditions. If exposure limits are
exceeded or irritation is experienced, NIOSH/MSHA approved respiratory protection should
be worn.
Hygiene Measures
Handle in accordance with good industrial hygiene and safety practice.
9. PHYSICAL AND CHEMICAL PROPERTIES
9. PHYSICAL AND CHEMICAL PROPERTIES
_____________________________________________________________________________________________ Page 4 / 9
Kolene Alko-NTM
May 1 2015
_____________________________________________________________________________________________
Information on basic physical and chemical properties
Physical State Odor
Solid bead/flake Odorless
Appearance Odor Threshold
Colorless to white No information available
Property
Values
pH
Melting Point/Range
132C / 270F
Boiling Point/Boiling Range
1390 C / 2534 F
Flash Point
None.
Evaporation rate
No data available
Flammability (solid, gas)
No data available
Flammability Limits in Air
upper flammability limit
No data available
lower flammability limit
No data available
Vapor Pressure
Not applicable
Vapor Density
Not applicable
Specific Gravity
2 g/cc (or ml) @ 20C
Water Solubility
Completely soluble
Solubility in other solvents
No data available
Partition coefficient: n-octanol/waterNo data available
Autoignition Temperature
Nonflammable
Decomposition Temperature
No data available
Viscosity
No data available
Flammable Properties
Explosive Properties Oxidizing Properties
Other information VOC Content (%)
Not flammable
No data available No data available
No data available
Remarks/ - Method All water solutions are strongly alkaline. None known None known None known None known None known
None known None known None known None known None known None known None known None known None known
10. STABILITY AND REACTIVITY
Reactivity No data available.
Chemical stability Stable under recommended storage conditions.
Possibility of hazardous reactions None under normal processing.
Hazardous Polymerization Hazardous polymerization does not occur.
Conditions to avoid Incompatible products.
Incompatible materials Reducing agents. Acids. Water. Organic material. Magnesium. Tin. Zinc. Aluminium.
Hazardous decomposition products None known based on information supplied.
11. TOXICOLOGICAL INFORMATION
_____________________________________________________________________________________________ Page 5 / 9
Kolene Alko-NTM
May 1 2015
_____________________________________________________________________________________________
Information on likely routes of exposure
Product Information
Inhalation Eye Contact
Skin Contact Ingestion
May cause irritation of respiratory tract. Causes serious eye damage. Corrosive to the eyes and may cause severe damage including blindness. Corrosive. Causes severe skin burns. Harmful if swallowed. Can burn mouth, throat, and stomach.
Chemical Name Potassium hydroxide
Potassium nitrate
LD50 Oral = 214 mg/kg ( Rat ) = 3015 mg/kg ( Rat )
LD50 Dermal -
LC50 Inhalation -
Symptoms related to the physical, chemical and toxicological characteristics
Symptoms No information available.
Delayed and immediate effects and also chronic effects from short and long term exposure
Sensitization Mutagenic Effects Carcinogenicity
No information available. No information available. Contains no ingredients above reportable quantities listed as a carcinogen.
Chemical Name
ACGIH
IARC
NTP
OSHA
Potassium nitrate
-
-
Reproductive Toxicity STOT - single exposure STOT - repeated exposure Aspiration Hazard
No information available. No information available. No information available.
Numerical measures of toxicity - Product
Acute Toxicity
0% of the mixture consists of ingredient(s) of unknown toxicity.
The following values are calculated based on chapter 3.1 of the GHS document:
LD50 Oral
567 mg/kg; Acute toxicity estimate
12. ECOLOGICAL INFORMATION
Ecotoxicity
The environmental impact of this product has not been fully investigated.
Chemical Name
Toxicity to Algae
Potassium hydroxide 1310-58-3
Persistence and Degradability
Bioaccumulation
Chemical Name Potassium hydroxide
Other Adverse Effects
13. DISPOSAL CONSIDERATIONS
Toxicity to Fish
Toxicity to Microorganisms
LC50 96 h: = 80 mg/L static (Gambusia affinis)
Daphnia Magna (Water Flea)
No information available.
Log Pow 0.83
No information available.
_____________________________________________________________________________________________ Page 6 / 9
Kolene Alko-NTM
May 1 2015
_____________________________________________________________________________________________
Waste Disposal Methods
Dispose of in accordance with federal, state, and local regulations
Contaminated Packaging
Do not re-use empty containers.
14. TRANSPORT INFORMATION
DOT
UN-Number Proper shipping name Hazard Class Packing Group Description Emergency Response Guide
UN1759 Corrosive solid, n.o.s. 8 II UN1759, Corrosive solid, n.o.s. (Potassium hydroxide), 8, II 154
TDG UN-Number Proper Shipping Name Hazard Class Packing Group Description
UN1759 Corrosive solid, n.o.s. 8 II UN1759, Corrosive solid, n.o.s. (Potassium hydroxide), 8, II
MEX UN-Number Proper Shipping Name Hazard Class Packing Group Description
UN1759 Corrosive solid, n.o.s. 8 II UN1759, Corrosive solid, n.o.s. (Potassium hydroxide), 8, II
ICAO UN-Number Proper shipping name Hazard Class Packing Group Description
UN1759 Corrosive solid, n.o.s. 8 II UN1759, Corrosive solid, n.o.s. (Potassium hydroxide), 8, II
IATA UN-Number Proper Shipping Name Hazard Class Packing Group ERG Code Description
UN1759 Corrosive solid, n.o.s. 8 II 8L UN1759, Corrosive solid, n.o.s. (Potassium hydroxide), 8, II
IMDG/IMO UN-Number Proper Shipping Name Hazard Class Packing Group EmS No. Description
UN1759 Corrosive solid, n.o.s. 8 II F-A, S-B UN1759, Corrosive solid, n.o.s. (Potassium hydroxide), 8, II
14. TRANSPORT INFORMATION continued
RID UN-Number
UN1759
_____________________________________________________________________________________________ Page 7 / 9
Kolene Alko-NTM
May 1 2015
_____________________________________________________________________________________________
Proper Shipping Name
Corrosive solid, n.o.s.
Hazard Class
8
Packing Group
II
Classification Code
C10
Description
UN1759, Corrosive solid, n.o.s. (Potassium hydroxide), 8, II
ADR UN-Number Proper Shipping Name Hazard Class Packing Group Classification Code Tunnel Restriction Code Description
UN1759 Corrosive solid, n.o.s. 8 II C10 (E) UN1759, Corrosive solid, n.o.s. (Potassium hydroxide), 8, II, (E)
ADN Proper Shipping Name Hazard Class Packing Group Classification Code Special Provisions Description Limited Quantity
Corrosive solid, n.o.s. 8 II C10 274 UN1759, Corrosive solid, n.o.s. (Potassium hydroxide), 8, II 1 kg
15. REGULATORY INFORMATION
International Inventories
TSCA
DSL
Complies
Complies
Legend
TSCA - United States Toxic Substances Control Act Section 8(b) Inventory
DSL/NDSL - Canadian Domestic Substances List/Non-Domestic Substances List
U.S. Federal Regulations
Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA). This product does not contain any chemicals which are subject to the reporting requirements of the Act and Title 40 of the Code of Federal Regulations, Part 372.
SARA 311/312 Hazard Categories
Acute Health Hazard
Yes
Chronic Health Hazard
No
Fire Hazard
No
Sudden Release of Pressure Hazard
No
Reactive Hazard
No
_____________________________________________________________________________________________ Page 8 / 9
Kolene Alko-NTM
May 1 2015
_____________________________________________________________________________________________
15. REGULATORY INFORMATION continued
Clean Water Act This product contains the following substances which are regulated pollutants pursuant to the Clean Water Act (40 CFR 122.21 and 40 CFR 122.42):
Chemical Name Potassium hydroxide
CWA - Reportable Quantities
1000 lb
CWA - Toxic Pollutants CWA - Priority Pollutants
CWA - Hazardous Substances
X
CERCLA This material, as supplied, contains one or more substances regulated as a hazardous substance under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA) (40 CFR 302):
Chemical Name Potassium hydroxide
Hazardous Substances RQs 1000 lb
Extremely Hazardous Substances RQs
RQ
RQ 1000 lb final RQ RQ 454 kg final RQ
U.S. State Regulations
California Proposition 65 This product does not contain any Proposition 65 chemicals.
U.S. State Right-to-Know Regulations
Chemical Name Potassium hydroxide
Potassium nitrate
New Jersey X
X
Massachusetts X
X
Pennsylvania X
X
Illinois
Rhode Island X
X
U.S. EPA Label Information EPA Pesticide Registration Number
16. OTHER INFORMATION
Not applicable
NFPA HMIS
Health Hazard 3 Health Hazard 3
Flammability 0 Flammability 0
Instability 0 Physical Hazard 0
Physical and Chemical Hazards Personal Protection X
Prepared By
Issuing Date Revision Date Revision Note
Product Stewardship 23 British American Blvd. Latham, NY 12110 1-800-572-6501 30-Jul-2014 01-May-2015 Reformatted content JCMalloy Vice President - CTO
General Disclaimer The information provided on this SDS is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guide for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered as a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other material or in any process, unless specified in the text. End of Safety Data Sheet
_____________________________________________________________________________________________ Page 9 / 9
Safety Data Sheet
#224
Revision Number: 004.0
Issue date: 09/16/2015
1. PRODUCT AND COMPANY IDENTIFICATION
Product name:
BONDERITE M-CR 600 AERO known
as ALODINE 600
Product type:
Conversion coating
Restriction of Use: None identified
Company address:
Henkel Corporation
One Henkel Way
Rocky Hill, Connecticut 06067
IDH number:
594038
Region:
United States
Contact information:
Telephone: (860) 571-5100
MEDICAL EMERGENCY Phone: Poison Control Center
1-877-671-4608 (toll free) or 1-303-592-1711
TRANSPORT EMERGENCY Phone: CHEMTREC
1-800-424-9300 (toll free) or 1-703-527-3887
Internet: www.henkelna.com
2. HAZARDS IDENTIFICATION
DANGER:
EMERGENCY OVERVIEW
MAY INTENSIFY FIRE; OXIDIZER. HARMFUL IF SWALLOWED. FATAL IN CONTACT WITH SKIN OR IF INHALED. CAUSES SEVERE SKIN BURNS AND EYE DAMAGE. MAY CAUSE AN ALLERGIC SKIN REACTION. MAY CAUSE RESPIRATORY IRRITATION. MAY CAUSE DROWSINESS OR DIZZINESS. MAY CAUSE CANCER.
HAZARD CLASS OXIDIZING SOLID ACUTE TOXICITY ORAL ACUTE TOXICITY INHALATION ACUTE TOXICITY DERMAL SKIN CORROSION SERIOUS EYE DAMAGE SKIN SENSITIZATION CARCINOGENICITY SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE
PICTOGRAM(S)
HAZARD CATEGORY 2 4 2 2 1B 1 1 1A 3
Precautionary Statements Prevention:
IDH number: 594038
Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Keep away from heat. Keep away from clothing and other combustible materials. Take any precaution to avoid mixing with combustibles. Do not breathe dust or fumes. Do not get in eyes, on skin, or on clothing. Wash thoroughly after handling. Do not eat, drink or smoke when using this product. Use only outdoors or in a well-ventilated area. Contaminated work clothing should not be allowed out of the workplace. Wear protective gloves, eye protection, and face protection. Use personal protective equipment as required. [In case of inadequate ventilation] wear respiratory protection.
Product name: BONDERITE M-CR 600 AERO known as ALODINE 600 Page 1 of 6
Response:
Storage: Disposal:
If SWALLOWED: Immediately call poison control or physician if you feel unwell. IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. If on skin (or hair): Take off immediately all contaminated clothing. IF INHALED: Remove person to fresh air and keep comfortable for breathing. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. IF exposed or concerned: Get medical attention. Immediately call a poison control center or physician. If skin irritation or rash occurs: Get medical attention. Wash contaminated clothing before reuse. In case of fire: Use foam, dry chemical or carbon dioxide to extinguish. Store in a well-ventilated place. Keep container tightly closed. Store locked up. Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.
Classification complies with OSHA Hazard Communication Standard (29 CFR 1910.1200) and is consistent with the provisions of the United Nations Globally Harmonized System of Classification and Labeling of Chemicals (GHS).
See Section 11 for additional toxicological information.
3. COMPOSITION / INFORMATION ON INGREDIENTS
Hazardous Component(s)
Sodium borofluoride Chromium(VI) oxide Dipotassium hexafluorozirconate
CAS Number
13755-29-8 1333-82-0 16923-95-8
Percentage*
30 - 60 30 - 60 10 - 30
* Exact percentage is a trade secret. Concentration range is provided to assist users in providing appropriate protections.
4. FIRST AID MEASURES
Inhalation: Skin contact: Eye contact: Ingestion:
Symptoms:
If inhaled, immediately remove the affected person to fresh air. If symptoms develop and persist, get medical attention.
Remove contaminated clothing and footwear. For skin contact, flush with large amounts of water. Seek immediate medical attention.
In case of contact with the eyes, rinse immediately with plenty of water for 15 minutes, and seek immediate medical attention.
DO NOT induce vomiting unless directed to do so by medical personnel. Give one to two glasses of water or milk. Never give anything by mouth to a victim who is unconscious or is having convulsions.
See Section 11.
5. FIRE FIGHTING MEASURES
Extinguishing media: Special firefighting procedures: Unusual fire or explosion hazards:
Use media appropriate for surrounding material.
Wear full protective clothing. Wear self-contained breathing apparatus.
Oxidizing agent, may cause spontaneous ignition of combustible materials. Violent reactions may occur with organic materials or reducing agents.
IDH number: 594038
Product name: BONDERITE M-CR 600 AERO known as ALODINE 600 Page 2 of 6
Hazardous combustion products:
Irritating and toxic gases or fumes may be released during a fire.
6. ACCIDENTAL RELEASE MEASURES
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Environmental precautions:
Prevent further leakage or spillage if safe to do so. Wear appropriate personal protective equipment. Do not allow product to enter sewer or waterways.
Clean-up methods:
Spills should be cleaned immediately to prevent dispersion of airborne dusts. Follow all local, state, federal and provincial regulations for disposal.
7. HANDLING AND STORAGE
Handling:
Avoid contact with eyes, skin and clothing. Avoid breathing dust. Wash thoroughly after handling. For industrial use only.
Storage:
Store in a cool, dry, well-ventilated area.
For information on product shelf life, please review labels on container or check the Technical Data Sheet.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Employers should complete an assessment of all workplaces to determine the need for, and selection of, proper exposure controls and protective equipment for each task performed.
Hazardous Component(s) Sodium borofluoride
ACGIH TLV
2 mg/m3 TWA Inhalable fraction.
6 mg/m3 STEL Inhalable fraction.
OSHA PEL None
AIHA WEEL None
OTHER None
Chromium(VI) oxide Dipotassium hexafluorozirconate
0.05 mg/m3 TWA (as Cr)
5 mg/m3 TWA (as Zr) 10 mg/m3 STEL (as
Zr) 2.5 mg/m3 TWA (as
F)
0.005 mg/m3 TWA 0.0025 mg/m3 OSHA_ACT
0.1 mg/m3 Ceiling 5 mg/m3 PEL (as Zr) 2.5 mg/m3 PEL (as
F) 2.5 mg/m3 TWA
Dust.
None None
None None
Engineering controls:
Ventilation should effectively remove and prevent buildup of any dust generated from the handling of this product.
Respiratory protection:
If ventilation is not sufficient to effectively prevent buildup of dust, appropriate NIOSH/MSHA respiratory protection must be provided.
Eye/face protection:
Wear chemical goggles and face shield.
Skin protection:
Use of impervious apron and boots are recommended. Gloves should be tested to determine suitability for prolonged contact.
Physical state: Color: Odor: Odor threshold: pH: Vapor pressure: Boiling point/range: Melting point/ range:
9. PHYSICAL AND CHEMICAL PROPERTIES
Solid Red-brown Bland Not available. 1.3 - 1.7 (2% solution) Not applicable Not applicable Not determined
IDH number: 594038
Product name: BONDERITE M-CR 600 AERO known as ALODINE 600 Page 3 of 6
Specific gravity: Vapor density: Flash point: Flammable/Explosive limits - lower: Flammable/Explosive limits - upper: Autoignition temperature: Evaporation rate: Solubility in water: Partition coefficient (n-octanol/water): VOC content: Viscosity: Decomposition temperature:
Not applicable Not applicable Not applicable Not available. Not available. Not applicable Not applicable Moderate Not determined Not applicable Not available. Not available.
10. STABILITY AND REACTIVITY
Stability:
Stable at normal conditions.
Hazardous reactions:
Will not occur.
Hazardous decomposition products:
May liberate hydrogen fluoride.
Incompatible materials:
Avoid contact with organic materials, oils, greases, and any oxidizable materials. This product may react with strong alkalies.
Reactivity:
Not available.
Conditions to avoid:
This product is an OXIDIZING AGENT - avoid contact with organic material.
11. TOXICOLOGICAL INFORMATION
Relevant routes of exposure: Skin, Inhalation, Eyes, Ingestion
IDH number: 594038
Product name: BONDERITE M-CR 600 AERO known as ALODINE 600 Page 4 of 6
Potential Health Effects/Symptoms
Inhalation: Skin contact:
Eye contact: Ingestion:
Mists, vapors or liquid may cause severe irritation or burns. Prolonged or repeated breathing may cause ulceration of nasal membranes. Contact with broken skin may lead to formation of firmly marginated "chrome sores". Product contains chromium, which may cause an allergic skin sensitization reaction. Massive overexposures may lead to kidney failure and death. Following skin exposure to this product, the sensation of irritation or pain may be delayed. This product is severely irritating to the eyes and may cause irreversible damage including burns and blindness. This product may produce corrosive damage to the gastrointestinal tract if it is swallowed. Ingestion of small amounts of this product may result in potentially fatal hypocalcemia and systemic toxicity.
Hazardous Component(s) Sodium borofluoride Chromium(VI) oxide
Dipotassium hexafluorozirconate
LD50s and LC50s
None
Oral LD50 (RAT) = 25 mg/kg Oral LD50 (RAT) = 29 mg/kg Oral LD50 (RAT) = 135 mg/kg Oral LD50 (RAT) = 80 mg/kg Dermal LD50 (RABBIT) = 30 mg/kg Inhalation LC50 (RAT, 4 h) = 0.087 mg/l Inhalation LC50 (RAT, 4 h) = 0.137 mg/l
None
Immediate and Delayed Health Effects
Cardiac, Central nervous system, Developmental, Gastrointestinal, Irritant,
Kidney, Metabolic, Reproductive
Allergen, Blood, Central nervous system, Corrosive, Carcinogen, Developmental, Eyes,
Gastrointestinal, Irritant, Kidney, Liver, Mutagen, Reproductive, Respiratory
Allergen, Blood, Cardiac, Central nervous system, Corrosive, Gastrointestinal tract, Irritant, Kidney, Lung, Metabolic, Muscle, Teeth, Less weight gain and food intake.
Hazardous Component(s)
Sodium borofluoride Chromium(VI) oxide Dipotassium hexafluorozirconate
NTP Carcinogen
No Known To Be Human
Carcinogen. No
IARC Carcinogen
No Group 1
No
OSHA Carcinogen (Specifically Regulated)
No Yes No
12. ECOLOGICAL INFORMATION
Ecological information:
No data available.
13. DISPOSAL CONSIDERATIONS
Information provided is for unused product only.
Recommended method of disposal: Hazardous waste number:
Follow all local, state, federal and provincial regulations for disposal.
If discarded, this product is considered a RCRA ignitable waste, D001. This product contains chromium which is a hazardous waste (D007).
14. TRANSPORT INFORMATION
The transport information provided in this section only applies to the material/formulation itself, and is not specific to any package/configuration.
U.S. Department of Transportation Ground (49 CFR)
Proper shipping name:
Chromium trioxide, anhydrous
Hazard class or division:
5.1 (6.1, 8)
Identification number:
UN 1463
Packing group:
II
DOT Hazardous Substance(s):
Chromic acid, Zirconium potassium fluoride
IDH number: 594038
Product name: BONDERITE M-CR 600 AERO known as ALODINE 600 Page 5 of 6
International Air Transportation (ICAO/IATA) Proper shipping name: Hazard class or division: Identification number: Packing group:
Chromium trioxide, anhydrous 5.1 (6.1, 8) UN 1463 II
Water Transportation (IMO/IMDG) Proper shipping name: Hazard class or division: Identification number: Packing group:
CHROMIUM TRIOXIDE, ANHYDROUS 5.1 (6.1, 8) UN 1463 II
15. REGULATORY INFORMATION
United States Regulatory Information TSCA 8 (b) Inventory Status: TSCA 12 (b) Export Notification:
CERCLA/SARA Section 302 EHS: CERCLA/SARA Section 311/312: CERCLA/SARA Section 313:
CERCLA Reportable quantity:
California Proposition 65:
All components are listed or are exempt from listing on the Toxic Substances Control Act Inventory. Chromium(VI) oxide (CAS# 1333-82-0). Chromium(VI) oxide (CAS# 1333-82-0).
None above reporting de minimis Immediate Health, Delayed Health, Reactive This product contains the following toxic chemicals subject to the reporting requirements of section 313 of the Emergency Planning and Community Right-To-Know Act of 1986 (40 CFR 372). Chromium(VI) oxide (CAS# 1333-82-0). Dipotassium hexafluorozirconate (CAS# 16923-95-8) 1,000 lbs. (454 kg) Chromium(VI) oxide (CAS# 1333-82-0) 10 lbs. (4.54 kg)
This product contains a chemical known in the State of California to cause cancer. This product contains a chemical known to the State of California to cause birth defects or other reproductive harm.
Canada Regulatory Information
CEPA DSL/NDSL Status:
All components are listed on or are exempt from listing on the Canadian Domestic Substances List.
16. OTHER INFORMATION
This safety data sheet contains changes from the previous version in sections: This Safety Data Sheet contains changes from the previous version in Section(s): 2, 4, 7 ,13
Prepared by:
John DiCerbo, Sr. Regulatory Affairs Specialist
Issue date:
09/16/2015
DISCLAIMER: The data contained herein are furnished for information only and are believed to be reliable. However, Henkel Corporation and its affiliates ("Henkel") does not assume responsibility for any results obtained by persons over whose methods Henkel has no control. It is the user's responsibility to determine the suitability of Henkel's products or any production methods mentioned herein for a particular purpose, and to adopt such precautions as may be advisable for the protection of property and persons against any hazards that may be involved in the handling and use of any Henkel's products. In light of the foregoing, Henkel specifically disclaims all warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, arising from sale or use of Henkel's products. Henkel further disclaims any liability for consequential or incidental damages of any kind, including lost profits.
IDH number: 594038
Product name: BONDERITE M-CR 600 AERO known as ALODINE 600 Page 6 of 6
Safety Data Sheet
#222
Revision Number: 005.0
Issue date: 04/04/2016
1. PRODUCT AND COMPANY IDENTIFICATION
Product name:
BONDERITE M-CR 1200S AERO
Product type:
Conversion coating
Restriction of Use: None identified
Company address:
Henkel Corporation
One Henkel Way
Rocky Hill, Connecticut 06067
IDH number:
593964
Region:
United States
Contact information:
Telephone: (860) 571-5100
MEDICAL EMERGENCY Phone: Poison Control Center
1-877-671-4608 (toll free) or 1-303-592-1711
TRANSPORT EMERGENCY Phone: CHEMTREC
1-800-424-9300 (toll free) or 1-703-527-3887
Internet: www.henkelna.com
2. HAZARDS IDENTIFICATION
DANGER:
EMERGENCY OVERVIEW
MAY INTENSIFY FIRE; OXIDIZER. HARMFUL IF SWALLOWED. FATAL IN CONTACT WITH SKIN OR IF INHALED. CAUSES SEVERE SKIN BURNS AND EYE DAMAGE. MAY CAUSE AN ALLERGIC SKIN REACTION. MAY CAUSE CANCER.
OXIDIZING SOLID ACUTE TOXICITY ORAL ACUTE TOXICITY INHALATION ACUTE TOXICITY DERMAL SKIN CORROSION SERIOUS EYE DAMAGE SKIN SENSITIZATION CARCINOGENICITY
HAZARD CLASS PICTOGRAM(S)
HAZARD CATEGORY 2 4 2 2 1B 1 1 1A
Precautionary Statements Prevention:
Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Keep away from heat. Keep away from clothing and other combustible materials. Take any precaution to avoid mixing with combustibles. Do not breathe dust or fumes. Do not get in eyes, on skin, or on clothing. Wash thoroughly after handling. Do not eat, drink or smoke when using this product. Use only outdoors or in a well-ventilated area. Contaminated work clothing should not be allowed out of the workplace. Wear protective gloves, eye protection, and face protection. Use personal protective equipment as required. [In case of inadequate ventilation] wear respiratory protection.
IDH number: 593964
Page 1 of 7
Product name: BONDERITE M-CR 1200S AERO
Response:
Storage: Disposal:
If SWALLOWED: Immediately call poison control or physician if you feel unwell. IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. If on skin (or hair): Take off immediately all contaminated clothing. IF INHALED: Remove person to fresh air and keep comfortable for breathing. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. IF exposed or concerned: Get medical attention. Immediately call a poison control center or physician. If skin irritation or rash occurs: Get medical attention. Wash contaminated clothing before reuse. In case of fire: Use foam, dry chemical or carbon dioxide to extinguish. Store in a well-ventilated place. Keep container tightly closed. Store locked up. Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.
Classification complies with OSHA Hazard Communication Standard (29 CFR 1910.1200) and is consistent with the provisions of the United Nations Globally Harmonized System of Classification and Labeling of Chemicals (GHS).
See Section 11 for additional toxicological information.
3. COMPOSITION / INFORMATION ON INGREDIENTS
Hazardous Component(s)
Chromium(VI) oxide Potassium tetrafluoroborate Tripotassium hexacyanoferrate Sodium fluoride Dipotassium hexafluorozirconate
CAS Number
1333-82-0 14075-53-7 13746-66-2 7681-49-4 16923-95-8
Percentage*
30 - 60 10 - 30 10 - 30 5 - 10 5 - 10
* Exact percentage is a trade secret. Concentration range is provided to assist users in providing appropriate protections.
Inhalation: Skin contact: Eye contact: Ingestion: Symptoms: Notes to physician:
Extinguishing media:
4. FIRST AID MEASURES
If inhaled, immediately remove the affected person to fresh air. If symptoms develop and persist, get medical attention.
Remove contaminated clothing and footwear. For skin contact, flush with large amounts of water. Seek immediate medical attention. If irritation persists, repeat flushing and get medical attention. Discard any shoes or clothing items that cannot be decontaminated.
In case of contact with the eyes, rinse immediately with plenty of water for 15 minutes, and seek immediate medical attention.
Get immediate medical attention. Do not induce vomiting. Give one to two glasses of water or milk. Never give anything by mouth to a victim who is unconscious or is having convulsions.
See Section 11.
Ocular exposure to corrosive fluoride compounds has been treated with isotonic sodium chloride or magnesium chloride. Dermal exposure to corrosive fluoride compounds has been treated with calcium gluconate or calcium carbonate gel applied topically to the affected areas to relieve pain at the site of exposure. Treatment of hypocalcemia associated with corrosive fluoride compounds exposure may be corrected by intravenous calcium gluconate or calcium chloride. Treatment of hypomagnesemia may be corrected by intravenous magnesium sulfate.
5. FIRE FIGHTING MEASURES
Use media appropriate for surrounding material.
IDH number: 593964
Page 2 of 7
Product name: BONDERITE M-CR 1200S AERO
Special firefighting procedures: Unusual fire or explosion hazards:
Hazardous combustion products:
Wear full protective clothing. Wear self-contained breathing apparatus.
Oxidizing agent, may cause spontaneous ignition of combustible materials. Under fire conditions, decomposing material may form a hot, viscous foam. Violent reactions may occur with organic materials or reducing agents. Empty containers retain product residue, so obey hazard warnings and handle empty containers as if they were full.
Irritating and toxic gases or fumes may be released during a fire.
6. ACCIDENTAL RELEASE MEASURES
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Environmental precautions:
Prevent further leakage or spillage if safe to do so. Wear appropriate protective equipment and clothing during clean-up.
Clean-up methods:
Spills should be cleaned immediately to prevent dispersion of airborne dusts. Do not allow product to enter sewer or waterways. Dispose of according to Federal, State and local governmental regulations.
7. HANDLING AND STORAGE
Handling:
Avoid contact with eyes, skin and clothing. Avoid breathing dust. Wash thoroughly after handling. For industrial use only.
Storage:
For safe storage, store between 5 C (41F) and 40 C (104F) Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Store below 110 F (43.3 C).
For information on product shelf life, please review labels on container or check the Technical Data Sheet.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Employers should complete an assessment of all workplaces to determine the need for, and selection of, proper exposure controls and protective equipment for each task performed.
Hazardous Component(s)
ACGIH TLV
OSHA PEL
AIHA WEEL
OTHER
Chromium(VI) oxide
Potassium tetrafluoroborate Tripotassium hexacyanoferrate Sodium fluoride
Dipotassium hexafluorozirconate Engineering controls:
0.05 mg/m3 TWA (as Cr)
6 mg/m3 STEL Inhalable fraction.
2 mg/m3 TWA Inhalable fraction.
None
2.5 mg/m3 TWA (as F)
5 mg/m3 TWA (as Zr) 10 mg/m3 STEL (as
Zr) 2.5 mg/m3 TWA (as
F)
0.005 mg/m3 TWA 0.0025 mg/m3 OSHA_ACT
0.1 mg/m3 Ceiling
None
None 2.5 mg/m3 PEL (as
F) 2.5 mg/m3 TWA
Dust. 5 mg/m3 PEL (as Zr) 2.5 mg/m3 PEL (as
F) 2.5 mg/m3 TWA
Dust.
None
None None None
None
None
None None None
None
Ventilation should effectively remove and prevent buildup of any dust generated from the handling of this product.
IDH number: 593964
Page 3 of 7
Product name: BONDERITE M-CR 1200S AERO
Respiratory protection:
If ventilation is not sufficient to effectively prevent buildup of dust, appropriate NIOSH/MSHA respiratory protection must be provided.
Eye/face protection:
Wear chemical goggles or a full face shield.
Skin protection:
Chemical resistant, impermeable gloves. The use of butyl rubber gloves is recommended. Use of impervious apron and boots are recommended.
9. PHYSICAL AND CHEMICAL PROPERTIES
Physical state: Color: Odor: Odor threshold: pH: Vapor pressure: Boiling point/range: Melting point/ range: Vapor density: Flash point: Flammable/Explosive limits - lower: Flammable/Explosive limits - upper: Autoignition temperature: Flammability: Evaporation rate: Solubility in water: Partition coefficient (n-octanol/water): VOC content: Viscosity: Decomposition temperature:
Solid orange Bland Not available. 1.30 - 1.60 Not determined Not applicable Not available. Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Appreciable Not determined Not applicable Not available. Not available.
10. STABILITY AND REACTIVITY
Stability:
Stable at normal conditions.
Hazardous reactions:
Will not occur.
Hazardous decomposition products:
May liberate hydrogen fluoride.
Incompatible materials:
Avoid contact with organic materials, oils, greases, and any oxidizable materials. This product may react with strong alkalies.
Reactivity:
Not available.
Conditions to avoid:
Oxidizing agent, may cause spontaneous ignition of combustible materials.
11. TOXICOLOGICAL INFORMATION
Relevant routes of exposure: Skin, Inhalation, Eyes
IDH number: 593964
Page 4 of 7
Product name: BONDERITE M-CR 1200S AERO
Potential Health Effects/Symptoms
Inhalation: Skin contact:
Eye contact: Ingestion:
Mists, vapors or liquid may cause severe irritation or burns. Prolonged or repeated breathing may cause ulceration of nasal membranes. Contact with broken skin may lead to formation of firmly marginated "chrome sores". Product contains chromium, which may cause an allergic skin sensitization reaction. Massive overexposures may lead to kidney failure and death. Following skin exposure to this product, the sensation of irritation or pain may be delayed. This product is severely irritating to the eyes and may cause irreversible damage including burns and blindness. This product may produce corrosive damage to the gastrointestinal tract if it is swallowed. Ingestion of small amounts of this product may result in potentially fatal hypocalcemia and systemic toxicity.
Hazardous Component(s)
Chromium(VI) oxide
Potassium tetrafluoroborate Tripotassium hexacyanoferrate Sodium fluoride
Dipotassium hexafluorozirconate
Hazardous Component(s) Chromium(VI) oxide Potassium tetrafluoroborate Tripotassium hexacyanoferrate Sodium fluoride Dipotassium hexafluorozirconate
Ecological information:
LD50s and LC50s
Oral LD50 (Rat) = 25 mg/kg Oral LD50 (Rat) = 29 mg/kg Oral LD50 (Rat) = 135 mg/kg Oral LD50 (Mouse) = 80 mg/kg Oral LD50 (Rat) = 80 mg/kg Dermal LD50 (Rabbit) = 30 mg/kg Inhalation LC50 (Rat, 4 h) = 0.087 mg/l Inhalation LC50 (Rat, 4 h) = 0.137 mg/l
None
None Oral LD50 (Mouse) = 44.3 mg/kg Oral LD50 (Mouse) = 46.0 mg/kg Oral LD50 (Rat) = 32.0 mg/kg Oral LD50 (Rat) = 51.6 mg/kg
Oral LD50 (Mouse) = 98 mg/kg
Immediate and Delayed Health Effects
Allergen, Blood, Central nervous system, Corrosive, Carcinogen, Developmental, Eyes,
Gastrointestinal, Irritant, Kidney, Liver, Mutagen, Reproductive, Respiratory
Cardiac, Central nervous system, Developmental, Gastrointestinal, Irritant,
Kidney, Metabolic, Reproductive Cellular
Blood, Cardiac, Central nervous system, Corrosive, Gastrointestinal tract, Irritant, Kidney, Metabolic, Muscle, Teeth, Less
weight gain and food intake. Allergen, Blood, Cardiac, Central nervous system, Corrosive, Gastrointestinal tract, Irritant, Kidney, Lung, Metabolic, Muscle, Teeth, Less weight gain and food intake.
NTP Carcinogen
Known To Be Human Carcinogen. No No No No
IARC Carcinogen
Group 1 No No No No
OSHA Carcinogen (Specifically Regulated)
Yes
No No No No
12. ECOLOGICAL INFORMATION
Harmful to aquatic organisms.
IDH number: 593964
Page 5 of 7
Product name: BONDERITE M-CR 1200S AERO
13. DISPOSAL CONSIDERATIONS
Information provided is for unused product only.
Recommended method of disposal: Hazardous waste number:
Dispose of according to Federal, State and local governmental regulations.
This product contains chromium which is a hazardous waste (D007). If discarded, this product is considered a RCRA ignitable waste, D001.
14. TRANSPORT INFORMATION
The transport information provided in this section only applies to the material/formulation itself, and is not specific to any package/configuration.
U.S. Department of Transportation Ground (49 CFR)
Proper shipping name:
Chromium trioxide, anhydrous
Hazard class or division:
5.1 (6.1, 8)
Identification number:
UN 1463
Packing group:
II
DOT Hazardous Substance(s):
Chromic acid, Sodium fluoride
International Air Transportation (ICAO/IATA) Proper shipping name: Hazard class or division: Identification number: Packing group:
Chromium trioxide, anhydrous 5.1 (6.1, 8) UN 1463 II
Water Transportation (IMO/IMDG) Proper shipping name: Hazard class or division: Identification number: Packing group: Marine pollutant:
CHROMIUM TRIOXIDE, ANHYDROUS 5.1 (6.1, 8) UN 1463 II Chromium trioxide
15. REGULATORY INFORMATION
United States Regulatory Information TSCA 8 (b) Inventory Status: TSCA 12 (b) Export Notification: CERCLA/SARA Section 302 EHS: CERCLA/SARA Section 311/312: CERCLA/SARA Section 313:
CERCLA Reportable quantity:
California Proposition 65:
All components are listed or are exempt from listing on the Toxic Substances Control Act Inventory. Chromium(VI) oxide (CAS# 1333-82-0).
None above reporting de minimis. Immediate Health, Delayed Health, Reactive This product contains the following toxic chemicals subject to the reporting requirements of section 313 of the Emergency Planning and Community Right-To-Know Act of 1986 (40 CFR 372). Chromium(VI) oxide (CAS# 1333-82-0). Chromium(VI) oxide (CAS# 1333-82-0) 10 lbs. (4.54 kg) Sodium fluoride (CAS# 7681-49-4) 1,000 lbs. (454 kg) Dipotassium hexafluorozirconate (CAS# 16923-95-8) 1,000 lbs. (454 kg)
This product contains a chemical known in the State of California to cause cancer. This product contains a chemical known to the State of California to cause birth defects or other reproductive harm.
Canada Regulatory Information CEPA DSL/NDSL Status:
All components are listed on or are exempt from listing on the Canadian Domestic Substances List.
IDH number: 593964
Page 6 of 7
Product name: BONDERITE M-CR 1200S AERO
16. OTHER INFORMATION
This safety data sheet contains changes from the previous version in sections: New information added in Section(s): 14
Prepared by:
Jennifer Mckay, Regulatory Affairs Specialist
Issue date:
04/04/2016
DISCLAIMER: The data contained herein are furnished for information only and are believed to be reliable. However, Henkel Corporation and its affiliates ("Henkel") does not assume responsibility for any results obtained by persons over whose methods Henkel has no control. It is the user's responsibility to determine the suitability of Henkel's products or any production methods mentioned herein for a particular purpose, and to adopt such precautions as may be advisable for the protection of property and persons against any hazards that may be involved in the handling and use of any Henkel's products. In light of the foregoing, Henkel specifically disclaims all warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, arising from sale or use of Henkel's products. Henkel further disclaims any liability for consequential or incidental damages of any kind, including lost profits.
IDH number: 593964
Page 7 of 7
Product name: BONDERITE M-CR 1200S AERO
Safety Data Sheet
Revision Number: 005.0
Issue date: 07/06/2015
1. PRODUCT AND COMPANY IDENTIFICATION
Product name:
Product type: Restriction of Use: Company address: Henkel Corporation One Henkel Way Rocky Hill, Connecticut
BONDERITE C-IC DEOXDZR 16R AERO known as TURCO DEOXIDIZER 16 REPL Rust dissolver None identified
06067
IDH number:
594403
Item number:
594403
Region:
United States
Contact information:
Telephone: (860) 571-5100
MEDICAL EMERGENCY Phone: Poison Control Center
1-877-671-4608 (toll free) or 1-303-592-1711
TRANSPORT EMERGENCY Phone: CHEMTREC
1-800-424-9300 (toll free) or 1-703-527-3887
Internet: www.henkelna.com
2. HAZARDS IDENTIFICATION
DANGER:
EMERGENCY OVERVIEW
TOXIC IF SWALLOWED OR IN CONTACT WITH SKIN. CAUSES SEVERE SKIN BURNS AND EYE DAMAGE. MAY CAUSE AN ALLERGIC SKIN REACTION. HARMFUL IF INHALED. MAY CAUSE RESPIRATORY IRRITATION. MAY CAUSE DROWSINESS OR DIZZINESS. MAY CAUSE CANCER.
HAZARD CLASS ACUTE TOXICITY ORAL ACUTE TOXICITY INHALATION ACUTE TOXICITY DERMAL SKIN CORROSION SERIOUS EYE DAMAGE SKIN SENSITIZATION CARCINOGENICITY SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE
PICTOGRAM(S)
HAZARD CATEGORY 3 4 3 1A 1 1 1A 3
Precautionary Statements Prevention: Response:
IDH number: 594403
Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Do not breathe vapors, mist, or spray. Wash thoroughly after handling. Do not eat, drink or smoke when using this product. Use only outdoors or in a well-ventilated area. Contaminated work clothing should not be allowed out of the workplace. Wear protective gloves, eye protection, and face protection. Use personal protective equipment as required. IF SWALLOWED: Immediately call a physician or poison control center. IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. If on skin (or hair): Take off immediately all contaminated clothing. IF INHALED: Remove person to fresh air and keep comfortable for breathing.
Product name: BONDERITE C-IC DEOXDZR 16R AERO known as TURCO DEOXIDIZER 16 REPL Page 1 of 6
Storage: Disposal:
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. IF exposed or concerned: Get medical attention. Immediately call a poison control center or physician. If skin irritation or rash occurs: Get medical attention. Wash contaminated clothing before reuse. Store in a well-ventilated place. Keep container tightly closed. Store locked up. Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.
Classification complies with OSHA Hazard Communication Standard (29 CFR 1910.1200) and is consistent with the provisions of the United Nations Globally Harmonized System of Classification and Labeling of Chemicals (GHS).
See Section 11 for additional toxicological information.
3. COMPOSITION / INFORMATION ON INGREDIENTS
Hazardous Component(s)
Chromic acid Hydrogen fluoride
CAS Number
7738-94-5 7664-39-3
Percentage*
10 - 30 5 - 10
* Exact percentage is a trade secret. Concentration range is provided to assist users in providing appropriate protections.
4. FIRST AID MEASURES
Inhalation: Skin contact:
Eye contact: Ingestion: Symptoms:
If mist or vapor of this product is inhaled, remove person immediately to fresh air. Seek medical attention if symptoms develop or persist.
Rinse with large amounts of running water. GET MEDICAL ATTENTION IMMEDIATELY! If iced 0.13% benzalkonium chloride (Zephiran) solution or 2.5% calcium gluconate gel are available, the rinsing may be limited to 5 minutes, with the soaks or gel applied as soon as the rinsing is stopped. If benzalkonium chloride or calcium gluconate gel is not available, rinsing must continue until medical treatment is provided.
In case of contact with the eyes, rinse immediately with plenty of water for 15 minutes, and seek immediate medical attention.
Get immediate medical attention. DO NOT induce vomiting unless directed to do so by medical personnel. Give one to two glasses of water or milk. Never give anything by mouth to a victim who is unconscious or is having convulsions.
See Section 11.
Notes to physician:
Ocular exposure to corrosive fluoride compounds has been treated with isotonic sodium chloride or magnesium chloride. Dermal exposure to corrosive fluoride compounds has been treated with calcium gluconate or calcium carbonate gel applied topically to the affected areas to relieve pain at the site of exposure.Treatment of hypocalcemia associated with corrosive fluoride compounds exposure may be corrected by intravenous calcium gluconate or calcium chloride. Treatment of hypomagnesemia may be corrected by intravenous magnesium sulfate.
5. FIRE FIGHTING MEASURES
Extinguishing media: Special firefighting procedures:
Use media appropriate for surrounding material. Wear full protective clothing. Wear self-contained breathing apparatus.
Unusual fire or explosion hazards:
If evaporated to dryness, solid residue is an oxidizing agent and may cause spontaneous ignition of combustible materials.
IDH number: 594403
Product name: BONDERITE C-IC DEOXDZR 16R AERO known as TURCO DEOXIDIZER 16 REPL Page 2 of 6
Hazardous combustion products:
Flammable and explosive hydrogen gas may be formed when hydrofluoric acid reacts with certain metals. Hydrogen fluoride gas may evolve when chemical is subjected to prolonged high temperature.
6. ACCIDENTAL RELEASE MEASURES
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Environmental precautions:
Prevent further leakage or spillage if safe to do so. Wear suitable protective clothing, gloves and eye/face protection.
Clean-up methods:
Absorb spill with inert material. Shovel material into appropriate container for disposal. Dispose of according to Federal, State and local governmental regulations. Do not allow product to enter sewer or waterways.
7. HANDLING AND STORAGE
Handling:
Avoid contact with eyes, skin and clothing. Avoid breathing vapors or mists of this product. Wash thoroughly after handling. For industrial use only. Use caution when combining with water; DO NOT add water to acid, ALWAYS add acid to water while stirring to prevent release of heat, steam and fumes.
Storage:
For safe storage, store at or above 40 F (4.4 C) Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Thaw and mix thoroughly if frozen.
For information on product shelf life, please review labels on container or check the Technical Data Sheet.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Employers should complete an assessment of all workplaces to determine the need for, and selection of, proper exposure controls and protective equipment for each task performed.
Hazardous Component(s)
ACGIH TLV
OSHA PEL
AIHA WEEL
OTHER
Chromic acid
Hydrogen fluoride
Engineering controls:
Respiratory protection:
Eye/face protection: Skin protection:
Physical state: Color: Odor: Odor threshold: pH: Vapor pressure:
0.05 mg/m3 TWA (as Cr)
2 ppm Ceiling (as F) 0.5 ppm TWA (as F)
(SKIN) (as F)
0.005 mg/m3 TWA 0.0025 mg/m3 OSHA_ACT
0.1 mg/m3 Ceiling 2.5 mg/m3 PEL (as
F) 3 ppm TWA
None None
None None
Provide local and general exhaust ventilation to effectively remove and prevent buildup of any vapors or mists generated from the handling of this product.
If ventilation is not sufficient to effectively prevent buildup of aerosols, mists or vapors, appropriate NIOSH/MSHA respiratory protection must be provided.
Wear chemical goggles; face shield (if splashing is possible).
Chemical resistant, impermeable gloves. Use of impervious apron and boots are recommended.
9. PHYSICAL AND CHEMICAL PROPERTIES
Liquid Red Sharp Not available. < 1 Not determined
IDH number: 594403
Product name: BONDERITE C-IC DEOXDZR 16R AERO known as TURCO DEOXIDIZER 16 REPL Page 3 of 6
Boiling point/range: Melting point/ range: Specific gravity: Vapor density: Flash point: Flammable/Explosive limits - lower: Flammable/Explosive limits - upper: Autoignition temperature: Evaporation rate: Solubility in water: Partition coefficient (n-octanol/water): VOC content: Viscosity: Decomposition temperature:
> 100 C (> 212F) 0 F (-17.8 C) 1.14 - 1.17 Not determined Not applicable Not applicable Not applicable Not applicable Not determined Complete Not determined Not applicable Not available. Not available.
10. STABILITY AND REACTIVITY
Stability:
Stable at normal conditions.
Hazardous reactions:
Will not occur.
Hazardous decomposition products:
May liberate hydrogen fluoride. Decomposes with heat to produce oxides of nitrogen.
Incompatible materials:
Reacts with cyanides and sulfides to cause the release of poisonous gases. This material will react with glass, concrete, certain metals, silica containing materials, rubber, leather, and many organics. Avoid contact with organic materials, oils, greases, and any oxidizable materials. This product may react with strong alkalies.
Reactivity:
Not available.
Conditions to avoid:
Store away from incompatible materials.
11. TOXICOLOGICAL INFORMATION
Relevant routes of exposure: Skin, Inhalation, Eyes
IDH number: 594403
Product name: BONDERITE C-IC DEOXDZR 16R AERO known as TURCO DEOXIDIZER 16 REPL Page 4 of 6
Potential Health Effects/Symptoms
Inhalation: Skin contact:
Eye contact: Ingestion:
Mists, vapors or liquid may cause severe irritation or burns. Contact with broken skin may lead to formation of firmly marginated "chrome sores". Product contains chromium, which may cause an allergic skin sensitization reaction. Massive overexposures may lead to kidney failure and death. Following skin exposure to this product, the sensation of irritation or pain may be delayed. A component in this product may be harmful or fatal if absorbed through the skin, especially if skin is damaged. This product is severely irritating to the eyes and may cause irreversible damage including burns and blindness. This product may produce corrosive damage to the gastrointestinal tract if it is swallowed. Ingestion of small amounts of this product may result in potentially fatal hypocalcemia and systemic toxicity.
Hazardous Component(s) Chromic acid Hydrogen fluoride
LD50s and LC50s
None
Inhalation LC50 (RAT, 15 min) = 2689 ppm Inhalation LC50 (RAT, 1 h) = 1278 ppm
Inhalation LC50 (RAT, 30 min) = 2042 ppm Inhalation LC50 (RAT, 5 min) = 4970 ppm
Immediate and Delayed Health Effects
Allergen, Blood, Carcinogen, Central nervous system, Corrosive, Developmental, Eyes, Gastrointestinal, Irritant, Kidney, Liver, Mutagen, Reproductive, Respiratory Allergen, Blood, Bone Marrow, Cardiac, Central nervous system, Corrosive, Irritant, Kidney, Liver, Lung, Muscle, Nervous System, Respiratory, Teeth
Hazardous Component(s)
Chromic acid Hydrogen fluoride
NTP Carcinogen
Known To Be Human Carcinogen. No
IARC Carcinogen
No No
OSHA Carcinogen (Specifically Regulated)
Yes No
12. ECOLOGICAL INFORMATION
Ecological information:
Not available.
13. DISPOSAL CONSIDERATIONS
Information provided is for unused product only.
Recommended method of disposal: Hazardous waste number:
Follow all local, state, federal and provincial regulations for disposal.
This product, if discarded directly, would be a characteristic RCRA corrosive waste (D002). This product contains chromium which is a hazardous waste (D007). This product contains a component or components identified as hazardous under 40 CFR 261.24. U134: Hydrogen fluoride
14. TRANSPORT INFORMATION
The transport information provided in this section only applies to the material/formulation itself, and is not specific to any package/configuration.
U.S. Department of Transportation Ground (49 CFR)
Proper shipping name:
Corrosive liquids, toxic, n.o.s. (Hydrofluoric acid, Chromic acid)
Hazard class or division:
8 (6.1)
Identification number:
UN 2922
Packing group:
II
DOT Hazardous Substance(s):
Chromic acid, Hydrofluoric acid
IDH number: 594403
Product name: BONDERITE C-IC DEOXDZR 16R AERO known as TURCO DEOXIDIZER 16 REPL Page 5 of 6
International Air Transportation (ICAO/IATA) Proper shipping name: Hazard class or division: Identification number: Packing group:
Corrosive liquid, toxic, n.o.s. 8 (6.1) UN 2922 II
(Hydrofluoric acid, Chromic acid)
Water Transportation (IMO/IMDG) Proper shipping name: Hazard class or division: Identification number: Packing group: Additional information:
CORROSIVE LIQUID, TOXIC, N.O.S. (Hydrofluoric acid, Chromic acid) 8 (6.1) UN 2922 II IMDG-Code: Segregation group 1- Acids
15. REGULATORY INFORMATION
United States Regulatory Information TSCA 8 (b) Inventory Status: TSCA 12 (b) Export Notification: CERCLA/SARA Section 302 EHS: CERCLA/SARA Section 311/312: CERCLA/SARA Section 313:
CERCLA Reportable quantity:
California Proposition 65:
All components are listed or are exempt from listing on the Toxic Substances Control Act Inventory. Chromic acid (CAS# 7738-94-5).
Hydrogen fluoride (CAS# 7664-39-3). Immediate Health, Delayed Health, Reactive This product contains the following toxic chemicals subject to the reporting requirements of section 313 of the Emergency Planning and Community Right-To-Know Act of 1986 (40 CFR 372). Chromic acid (CAS# 7738-94-5). Hydrogen fluoride (CAS# 7664-39-3). Chromic acid (CAS# 7738-94-5) 10 lbs. (4.54 kg) Hydrogen fluoride (CAS# 7664-39-3) 100 lbs. (45.4 kg)
This product contains a chemical known in the State of California to cause cancer. This product contains a chemical known to the State of California to cause birth defects or other reproductive harm.
Canada Regulatory Information
CEPA DSL/NDSL Status:
All components are listed on or are exempt from listing on the Canadian Domestic Substances List.
16. OTHER INFORMATION
This safety data sheet contains changes from the previous version in sections: New information added in Section(s): 1, 7, 9, 12 and 13.
Prepared by:
John DiCerbo, Sr. Regulatory Affairs Specialist
Issue date:
07/06/2015
DISCLAIMER: The data contained herein are furnished for information only and are believed to be reliable. However, Henkel Corporation and its affiliates ("Henkel") does not assume responsibility for any results obtained by persons over whose methods Henkel has no control. It is the user's responsibility to determine the suitability of Henkel's products or any production methods mentioned herein for a particular purpose, and to adopt such precautions as may be advisable for the protection of property and persons against any hazards that may be involved in the handling and use of any Henkel's products. In light of the foregoing, Henkel specifically disclaims all warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, arising from sale or use of Henkel's products. Henkel further disclaims any liability for consequential or incidental damages of any kind, including lost profits.
Distributed by: Rudolph Bros. & Co. 6550 Oley Speaks Way Canal Winchester, OH 43110 Phone: 614-833-0707 Fax: 800-600-9508 e-mail: rbcsupport@rudbro.com www.rudbro.com
IDH number: 594403
Product name: BONDERITE C-IC DEOXDZR 16R AERO known as TURCO DEOXIDIZER 16 REPL Page 6 of 6
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6
Revision Date 05/19/2016
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION
Product name
: Hydrofluoric Acid, Aqueous (70%)
Print Date 01/24/2017
Number
:
Product Use Description :
Note
:
Manufacturer or supplier's : details
For more information call :
In case of emergency call : : : :
000000001807
Chemical-Technical application
Synonyms: HF, Anhydrous HF, AHF, Hydrogen Fluoride, HF Acid For additional information, please visit http://www.HFacid.com (available 24 hours/day, 7days/week).
Brainerd Chemical 1600 South Wilson Ave Dunn, North Carolina 28334
800-522-8001 +1-910-980-1088
(Monday-Friday, 8:00am-5:00pm)
Transportation (CHEMTREC):
1-800-424-9300
(24 hours/day, 7 days/week)
SECTION 2. HAZARDS IDENTIFICATION Emergency Overview
Form
: liquid
Color
: colourless
Odor
: stinging
Classification of the substance or mixture
Classification of the substance or mixture
: Corrosive to metals, Category 1 Acute toxicity, Category 2, Oral Acute toxicity, Category 2, Inhalation Acute toxicity, Category 1, Dermal Skin corrosion, Category 1A Serious eye damage, Category 1
Page 1 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6
Revision Date 05/19/2016
GHS Label elements, including precautionary statements
Symbol(s)
:
Print Date 01/24/2017
Signal word Hazard statements
Precautionary statements
: Danger
: May be corrosive to metals. Fatal if swallowed, in contact with skin or if inhaled Causes severe skin burns and eye damage.
: Prevention: Keep only in original container. Do not breathe dust/ fume/ gas/ mist/ vapours/ spray. Do not get in eyes, on skin, or on clothing. Wash skin thoroughly after handling. Do not eat, drink or smoke when using this product. Use only outdoors or in a well-ventilated area. Wear protective gloves/ protective clothing. Wear eye protection/ face protection. Wear respiratory protection.
Response: IF SWALLOWED: Immediately call a POISON CENTER/doctor. IF SWALLOWED: rinse mouth. Do NOT induce vomiting. IF ON SKIN (or hair): Remove/ Take off immediately all contaminated clothing. Rinse skin with water/ shower. IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor. Remove/Take off immediately all contaminated clothing. Wash contaminated clothing before reuse. Absorb spillage to prevent material damage.
Storage: Store in a well-ventilated place. Keep container tightly closed. Store locked up. Keep only in original container.
Disposal: Dispose of contents/ container to an approved waste disposal plant.
Page 2 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6
Revision Date 05/19/2016
Print Date 01/24/2017
Hazards not otherwise classified
: Causes severe burns which may not be immediately painful or visible. May cause hypocalcemia (depletion of calcium in the body) which may be fatal. Specialized medical treatment is required for all exposures.
Carcinogenicity No component of this product present at levels greater than or equal to 0.1% is identified as a known or anticipated carcinogen by NTP, IARC, or OSHA.
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Chemical nature
: Mixture
Chemical name
Hydrofluoric acid
Water
CAS-No. 7664-39-3
7732-18-5
Concentration 70.00 %
30.00 %
SECTION 4. FIRST AID MEASURES
Inhalation Skin contact
: Remove to fresh air. Keep patient warm and at rest. Get competent medical attention immediately. If breathing has stopped, start artificial respiration at once. An authorized person should administer oxygen to a victim who is having difficulty breathing, until the victim is able to breathe easily by himself. Calcium gluconate, 2.5% in normal saline may be given by nebulizer with oxygen. Do not give stimulants unless instructed to do so by a physician. Victim should be examined by a physician and held under observation for at least 24 hours.
: Remove the victim from the contaminated area and immediately wash the burned area with plenty of water for a minimum of 15 minutes. Limit washing to 5 minutes if treatment specific for HF exposure is available. Remove all contaminated clothing while washing continuously. After thorough washing for at least 5 minutes, the burned area should be immersed in
Page 3 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6
Revision Date 05/19/2016
Print Date 01/24/2017
a solution of 0.13% iced aqueous Benzalkonium Chloride until
pain is relieved. As an alternate first aid treatment, 2.5%
calcium gluconate gel may be continuously massaged into the
burn area until the pain is relieved. For burns not responsive to
topical treatment (as measured by pain being present for
longer than 30 minutes) a physician may inject 2.5% - 5%
aqueous calcium gluconate beneath, around and in the burned
area. Use of local anesthetics is not recommended, as
reduction in pain is an indicator of effectiveness of treatment.
Eye contact
: Immediately flush the eyes for at least 15 minutes with large amounts of gently flowing water. Hold the eyelids open and away from the eye during irrigation to allow thorough flushing of the eyes. Do not use the benzalkonium chloride (Zephiran) solutions described for skin treatment. If the person is wearing contact lenses, the lenses should be removed, if possible. However, flushing with water should not be interrupted, and the lenses should be removed by a person who is qualified to do so. If sterile 1% calcium gluconate solution is available, water washing may be limited to 5 minutes, after which the 1% calcium gluconate solution should be used to irrigate the eye using a syringe or a continuous irrigation device. Take the victim to a doctor, preferably an eye specialist, as soon as possible. Ice water compresses may be applied to the eyes while transporting the victim to the doctor. If a physician is not immediately available, apply one or two drops of 0.5% tetracaine hydrochloride, 0.5% proparacaine, or other aqueous, topical ophthalmic anesthetic and continue irrigation. Use no other medications unless instructed to do so by a physician. Rubbing of the eyes is to be avoided. .
Ingestion
Notes to physician Treatment
: Have the victim drink several large glasses of water or milk to dilute the acid. Do not induce vomiting. Do not give emetics or baking soda. Never give anything by mouth to an unconscious person. Give several glasses of milk or several ounces of milk of magnesia, any calcium containing antacid or grind up and administer up to 30 antacid tablets with water. The calcium or magnesium in these compounds may act as an antidote; however this has not been supported in the literature. Get immediate medical attention. Ingestion of HF is a lifethreatening emergency.
: For large skin area burns (totaling greater than 25 square inches), for ingestion and for significant inhalation exposure, Page 4 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6
Revision Date 05/19/2016
Print Date 01/24/2017
severe systemic effects may occur. Monitor and correct for
hypocalcemia, cardiac arrhythmias, hypomagnesemia and
hyperkalemia. In some cases hemodialysis may be indicated.
For certain burns, especially of the digits, use of intra-arterial
calcium gluconate may be indicated. For inhalation exposures,
treat as chemical pneumonia. Monitor for hypocalcemia. 2.5%
calcium gluconate in normal saline by nebulizer or by
intermittent positive pressure breathing with 100% oxygen may
decrease pulmonary damage. Bronchodilators may also be
administered. A booklet titled "Recommended Medical
Treatment for Hydrofluoric Acid Exposure" is available from the
Honeywell HF website: http://www.HFacid.com.
SECTION 5. FIREFIGHTING MEASURES
Suitable extinguishing media
: Water spray Foam Carbon dioxide (CO2) Dry chemical On dilution or dissolving in water, considerable heating always occurs. Contact with a relatively small quantity of water creates violent reaction generating much heat and spattering of hot acid If use of water is necessary use copious amounts
Specific hazards during firefighting
: Fire or intense heat may cause violent rupture of packages. Use a water spray to cool fully closed containers. Reacts violently with water. Do not direct water spray at the point of leakage. Contact with metals liberates hydrogen gas. Hydrogen gas is flammable and may form an explosive atmosphere. Diking with silicon materials is to be avoided. May form Silicon tetrafluoride gas.
Special protective equipment for firefighters
: Personal protection through wearing a tightly closed chemical protection suit and a self-contained breathing apparatus. No unprotected exposed skin areas.
Further information
: Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Use water spray to cool unopened containers.
Page 5 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6
Revision Date 05/19/2016
Print Date 01/24/2017
SECTION 6. ACCIDENTAL RELEASE MEASURES
Personal precautions
: Immediately evacuate personnel to safe areas. Immediately contact emergency personnel. Ensure all affected individuals are in a safe environment. Wear personal protective equipment. Unprotected persons must be kept away. Keep people away from and upwind of spill/leak. Personal protection through wearing a tightly closed chemical protection suit and a self-contained breathing apparatus. Ensure all equipment (including Personal Protective Equipment (PPE)) is compatible with Hydrofluoric acid (HF).
Environmental precautions
: Prevent further leakage or spillage if safe to do so. Discharge into the environment must be avoided. Do not flush into surface water or sanitary sewer system. Do not allow run-off from fire fighting to enter drains or water courses. If the product contaminates rivers and lakes or drains inform respective authorities.
Methods for cleaning up
: Prevent spreading over a wide area (e.g. by containment or oil barriers). Diking with silicon materials is to be avoided. May form Silicon tetrafluoride gas. Suppress (knock down) gases/vapours/mists with a water spray (fog ). Do not direct water spray at the point of leakage. Use water spray cautiously and in large quantities. With acids neutralization takes place under development of heat. Do not pick up with the help of saw-dust or other combustible substances. Neutralize acidity with an appropriate alkaline material. Neutralize with caustics, lime, soda ash, baking soda or other appropriate alkaline material. Pay attention to the incompatibility statements in Section 10 when effecting neutralization.
SECTION 7. HANDLING AND STORAGE Handling
Handling
: Wear personal protective equipment. Exhaust ventilation at the object is necessary. Ensure all equipment (including Personal Protective Equipment
Page 6 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6
Revision Date 05/19/2016
Print Date 01/24/2017
(PPE)) is compatible with Hydrofluoric acid (HF).
Perform filling operations only at stations with exhaust
ventilation facilities.
Specialized medical treatment is required for all exposures.
Plan first aid action before beginning work with this product.
When diluting, add acids to water, never the other way around.
Do not swallow.
Do not breathe vapours or spray mist.
Do not get in eyes, on skin, or on clothing.
Advice on protection against fire and explosion
: No special precautions required.
Storage
Requirements for storage areas and containers
: Keep containers tightly closed in a cool, well-ventilated place. Store in a place accessible by authorized persons only. Store away from incompatible substances.
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Protective measures
: Ensure that eyewash stations and safety showers are close to the workstation location. Plan first aid action before beginning work with this product. Ensure all equipment (including Personal Protective Equipment (PPE)) is compatible with Hydrofluoric acid (HF).
Engineering measures
: Use with local exhaust ventilation. Apply technical measures to comply with the occupational exposure limits.
Eye protection
: Wear as appropriate: Goggles or face shield, giving complete protection to eyes
Hand protection
: Protective gloves Gloves must be inspected prior to use. Replace when worn.
Skin and body protection
: Wear suitable protective equipment. complete suit protecting against chemicals
Respiratory protection
: In case of insufficient ventilation wear suitable respiratory equipment. Use NIOSH approved respiratory protection. Have available emergency self-contained breathing apparatus or full-face airline respirator when using this chemical.
Hygiene measures
: When using, do not eat, drink or smoke. Page 7 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6
Revision Date 05/19/2016
Print Date 01/24/2017
Provide adequate ventilation.
Keep working clothes separately.
Contaminated work clothing should not be allowed out of the
workplace.
Do not swallow.
Do not breathe vapours or spray mist.
Do not get in eyes, on skin, or on clothing.
This material has an established AIHA ERPG exposure limit.
The current list of ERPG exposure limits can be found at
http://www.aiha.org/insideaiha/Gui deli ne De vel opm ent/ERPG/D
ocuments/2011erpgweelhandbook_table -only.pdf.
Exposure Guidelines
Components
CAS-No.
Value
Hydrofluoric acid
Further
:
information
7664-39-3
TWA :
Time
weighted
average
Expressed as : as F
Control parameters (0.5 ppm)
Upda te 2008
Basis
ACGIH:US. ACGIH Threshold Limit Values
Hydrofluoric acid
7664-39-3
SKIN_DE S : Skin designati on:
Can be absorbed through the skin.
2008
ACGIH:US. ACGIH Threshold Limit Values
Further information
: Expressed as : as F
Hydrofluoric acid
Further
:
information
7664-39-3
Ceiling :
Ceiling
Limit
Value:
Expressed as : as F
(2 ppm)
2008
ACGIH:US. ACGIH Threshold Limit Values
Hydrofluoric acid
7664-39-3
Conc : Concentr ation:
(30 ppm) NIOSH IDLH (Immediately Dangerous to Life or Health Concentrations)
2005
NIOSH/GUIDE:US. NIOSH: Pocket Guide to Chemical Hazards
Page 8 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6 Hydrofluoric acid
7664-39-3
Revision Date 05/19/2016
REL :
2.5 mg/m3
Recomm (3 ppm)
ended
exposure
limit
(REL):
Hydrofluoric acid
7664-39-3
Ceil_Tim e : Ceiling Limit Value and Time Period (if specified) :
5 mg/m3 (6 ppm)
Hydrofluoric acid
7664-39-3
PEL : Permissi ble exposure limit
2.5 mg/m3
Further information
: Expressed as : as F
Hydrofluoric acid
Further
:
information
7664-39-3
TWA :
Time
weighted
average
Expressed as : as F
(3 ppm)
Hydrofluoric acid
Further
:
information
7664-39-3
STEL :
Short
term
exposure
limit
Expressed as : as F
(6 ppm)
Hydrofluoric acid
7664-39-3
TWA : Time weighted average
(3 ppm)
2005
Print Date 01/24/2017
NIOSH/GUIDE:US. NIOSH: Pocket Guide to Chemical Hazards
2005
NIOSH/GUIDE:US. NIOSH: Pocket Guide to Chemical Hazards
02 2006
OSHA_TRANS:US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000)
1989
Z1A:US. OSHA Table Z-1-A (29 CFR 1910.1000)
1989
Z1A:US. OSHA Table Z-1-A (29 CFR 1910.1000)
02 2006
OSHA/Z2:US. OSHA Table Z-2 (29 CFR 1910.1000)
Page 9 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6
Revision Date 05/19/2016
SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES
Physical state
: liquid
Color
: colourless
Odor
: stinging
pH
: Note: acidic
Freezing point
: ca. -76 C
Boiling point/boiling range
: ca. 65 C at 1,013 hPa
Flash point
: Note: Not applicable
Print Date 01/24/2017
Lower explosion limit Upper explosion limit Vapor pressure Vapor density
Density Water solubility
: Note: Not applicable : Note: Not applicable
: 183 hPa at 21.1 C(70.0 F)
: 2.21 at 21.1 C 1.76 at 26.7 C
: ca. 1.230 g/cm3 at 20 C
: Note: completely miscible
Ignition temperature Decomposition temperature
: Note: Not applicable
: Note: Fire or intense heat may cause violent rupture of packages.
Page 10 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6 Corrosivity
Revision Date 05/19/2016 : Note: Corrosive to metals
Print Date 01/24/2017
SECTION 10. STABILITY AND REACTIVITY
Chemical stability Possibility of hazardous reactions Incompatible materials to avoid
Hazardous decomposition products
: Stable under normal conditions.
: Hazardous polymerisation does not occur.
: Glass and silicate-containing materials are attacked. HF contact with glass, concrete and other silicon bearing materials will yield silicon tetrafluoride gas. Pressure buildup from this process has been known to rupture glass containers. . HF contact with carbonates, sulfides and cyanides yield toxic gases such as carbon dioxide, hydrogen sulfide and hydrogen cyanide. Contact with alkalies and some oxides cause strong violent exothermic reactions. Contact with metals will yield hydrogen gas, a fire and explosive reactive hazard. On dilution or dissolving in water, considerable heating always occurs. When diluting, add acids to water, never the other way around.
: No hazardous decomposition products are known.
SECTION 11. TOXICOLOGICAL INFORMATION
Acute oral toxicity Acute inhalation toxicity
Acute dermal toxicity Skin irritation Hydrofluoric acid
: Acute toxicity estimate: 7.14 mg/kg Method: Calculation method
: Acute toxicity estimate: 0.76 mg/l , vapour Exposure time: 4 h Method: Calculation method
: Acute toxicity estimate: 7.14 mg/kg Method: Calculation method
: Species: Rabbit Classification: Corrosive Page 11 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6
Revision Date 05/19/2016 Method: OECD
Print Date 01/24/2017
Further information
: Note: Causes severe burns which may not be immediately painful or visible.The potential delay in clinical signs or symptoms for dilute solutions is given below.
HF Concentration (Delay in Symptoms) >50% (Immediately Apparent) 20%-50% (1-8 hours) 0%-20% (Up to 24 hours)Symptoms might include pain, redness of the skin and possible tissue destruction.Hydrofluoric Acid will penetrate skin and attack underlying tissues.May cause hypocalcemia (depletion of calcium in the body) which may be fatal.Chronic exposure to fluoride has been reported to result in tooth mottling in children, bone fluorosis, and sometimes osteosclerosis in adults and children.
SECTION 12. ECOLOGICAL INFORMATION
Toxicity to fish Hydrofluoric acid
: LC50: 107.5 mg/l Exposure time: 96 h Species: Oncorhynchus mykiss (rainbow trout) Test substance: Fluoride ion
LC50: 925 mg/l Exposure time: 96 h Species: Gambusia affinis (Mosquito fish) Test substance: Fluoride ion
Toxicity to daphnia and other aquatic invertebrates
Hydrofluoric acid
: EC50: 270 mg/l
Exposure time: 48 h
Species: Daphnia (water flea)
Test substance: Sodium fluoride
Further information on ecology
Page 12 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6
Revision Date 05/19/2016
Print Date 01/24/2017
SECTION 13. DISPOSAL CONSIDERATIONS
Disposal methods
: Observe all Federal, State, and Local Environmental regulations.
SECTION 14. TRANSPORT INFORMATION
DOT
UN/ID No. Proper shipping name Class Packing group Hazard Labels
: UN 1790 : Hydrofluoric acid
8 I 8 (6.1)
IATA IMDG
UN/ID No. Description of the goods Class Packaging group Hazard Labels Packing instruction (cargo aircraft) Packing instruction (passenger aircraft)
UN/ID No. Description of the goods Class Packaging group Hazard Labels EmS Number Marine pollutant
: UN 1790 : Hydrofluoric acid : 8 : I : 8 (6.1) : 854
: 850
: UN 1790 : Hydrofluoric acid : 8 : I : 8 (6.1) : F-A, S-B : no
SECTION 15. REGULATORY INFORMATION
Inventories
US. Toxic Substances Control Act
Australia. Industrial Chemical (Notification and Assessment) Act
Canada. Canadian
: On TSCA Inventory : On the inventory, or in compliance with the inventory
: All components of this product are on the Canadian DSL Page 13 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6 Environmental Protection Act (CEPA). Domestic Substances List (DSL)
Revision Date 05/19/2016
Print Date 01/24/2017
Japan. Kashin-Hou Law List
: On the inventory, or in compliance with the inventory
Korea. Toxic Chemical Control Law (TCCL) List
: On the inventory, or in compliance with the inventory
Philippines. The Toxic Substances and Hazardous and Nuclear Waste Control Act
: On the inventory, or in compliance with the inventory
China. Inventory of Existing : On the inventory, or in compliance with the inventory Chemical Substances
NZIOC - New Zealand
: On the inventory, or in compliance with the inventory
National regulatory information
US. EPA CERCLA Hazardous Substances (40 CFR 302)
: The following component(s) of this product is/are subject to release reporting under 40 CFR 302 when release exceeds the Reportable Quantity (RQ):
Reportable quantity: 100 lbs : Hydrogen fluoride
7664-39-3
SARA 302 Components
: The following components are subject to reporting levels
established by SARA Title III, Section 302:
: Hydrofluoric acid
7664-39-3
SARA 313 Components
: The following components are subject to reporting levels
established by SARA Title III, Section 313:
: Hydrofluoric acid
7664-39-3
SARA 311/312 Hazards
: Acute Health Hazard Chronic Health Hazard
CERCLA Reportable Quantity
: 143 lbs
Page 14 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6 California Prop. 65
Revision Date 05/19/2016
Print Date 01/24/2017
: This product does not contain any chemicals known to State of
California to cause cancer, birth defects, or any other
reproductive harm.
Massachusetts RTK New Jersey RTK Pennsylvania RTK WHMIS Classification
: Hydrofluoric acid
7664-39-3
: Hydrofluoric acid
7664-39-3
: Hydrofluoric acid
7664-39-3
: D1A: Very Toxic Material Causing Immediate and Serious Toxic Effects D2A: Very Toxic Material Causing Other Toxic Effects E: Corrosive Material This product has been classified according to the hazard criteria of the CPR and the MSDS contains all of the information required by the CPR.
SECTION 16. OTHER INFORMATION
Health hazard Flammability Physical Hazard Instability
HMIS III : 4* : 0 : 1 :
NFPA 4 0
1
* - Chronic health hazard
Hazard rating and rating systems (e.g. HMIS III, NFPA): This information is intended solely for the use of individuals trained in the particular system.
Further information
The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportat ion, disposal and release and is not to be considered a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text. Final determination of suitability of any
Page 15 / 16
SAFETY DATA SHEET
Hydrofluoric Acid, Aqueous (70%)
000000001807
Version 3.6
Revision Date 05/19/2016
Print Date 01/24/2017
material is the sole responsibility of the user. This information should not constitute a guarantee for
any specific product properties.
Changes since the last version are highlighted in the margin. This version replaces all previous versions. Previous Issue Date: 11/06/2015
Page 16 / 16
Safety Data Sheet
NITRIC ACID 42 BAUM
Version 1.3
Revision Date: 08/02/2022
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION
Product name
: NITRIC ACID 42 BAUM
Recommended use of the chemical and restrictions on use
Recommended use
: Industrial chemical
Manufacturer or supplier's details
Company
: Univar Solutions USA, Inc.
Address
3075 Highland Pkwy Suite 200
Downers Grove, IL 60515
United States of America (USA)
Emergency telephone number:
Transport North America: CHEMTREC (1-800-424-9300)
CHEMTREC INTERNATIONAL Tel # 703-527-3887
Additional Information:
: Responsible Party: Product Compliance Department E-mail: SDSNA@univarsolutions.com SDS Requests: 1-855-429-2661 Website: www.univarsolutions.com
SECTION 2. HAZARDS IDENTIFICATION
GHS Classification Oxidizing liquids Corrosive to metals Acute toxicity (Inhalation) Skin corrosion Serious eye damage
: Category 3 : Category 1 : Category 3 : Category 1A : Category 1
GHS label elements
Hazard pictograms
:
Signal word Hazard statements Precautionary statements
SDS Number: 100000005010
: Danger
: H272 May intensify fire; oxidizer. H290 May be corrosive to metals. H314 Causes severe skin burns and eye damage. H331 Toxic if inhaled.
: Prevention: P210 Keep away from heat. P220 Keep/ Store away from clothing/ combustible materials. P221 Take any precaution to avoid mixing with combustibles.
1 / 12
NITRIC ACID 42 BAUM
Safety Data Sheet
NITRIC ACID 42 BAUM
Version 1.3
Revision Date: 08/02/2022
P234 Keep only in original container. P261 Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray. P264 Wash skin thoroughly after handling. P271 Use only outdoors or in a well-ventilated area. P280 Wear protective gloves/ protective clothing/ eye protection/ face protection. Response: P301 + P330 + P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower. P304 + P340 + P310 IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/ doctor. P305 + P351 + P338 + P310 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/ doctor. P363 Wash contaminated clothing before reuse. P370 + P378 In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish. P390 Absorb spillage to prevent material damage. Storage: P403 + P233 Store in a well-ventilated place. Keep container tightly closed. P405 Store locked up. P406 Store in corrosive resistant container with a resistant inner liner. Disposal: P501 Dispose of contents/ container to an approved waste disposal plant.
Other hazards None known.
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Substance / Mixture
: Mixture
Hazardous components
CAS-No.
Chemical name
7697-37-2
Nitric acid
Any Concentration shown as a range is due to batch variation.
Weight percent 50 - 70
SECTION 4. FIRST AID MEASURES
General advice
: Move out of dangerous area. Consult a physician. Show this safety data sheet to the doctor in attendance. Do not leave the victim unattended.
SDS Number: 100000005010
2 / 12
NITRIC ACID 42 BAUM
Safety Data Sheet
NITRIC ACID 42 BAUM
Version 1.3
Revision Date: 08/02/2022
If inhaled In case of skin contact In case of eye contact
If swallowed
: If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician. Move to fresh air.
: Immediate medical treatment is necessary as untreated wounds from corrosion of the skin heal slowly and with difficulty. If on skin, rinse well with water. If on clothes, remove clothes. Wash contaminated clothing before re-use. Thoroughly clean shoes before reuse.
: Small amounts splashed into eyes can cause irreversible tissue damage and blindness. In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Continue rinsing eyes during transport to hospital. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist. Take victim immediately to hospital.
: Clean mouth with water and drink afterwards plenty of water. Keep respiratory tract clear. Do NOT induce vomiting. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Take victim immediately to hospital.
SECTION 5. FIREFIGHTING MEASURES
Suitable extinguishing media
: Foam Dry chemical Carbon dioxide (CO2)
Unsuitable extinguishing media
: High volume water jet
Specific hazards during firefighting
: Do not allow run-off from fire fighting to enter drains or water courses.
Hazardous combustion prod- : Nitrogen oxides (NOx) ucts
Further information
: Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations. For safety reasons in case of fire, cans should be stored separately in closed containments.
SDS Number: 100000005010
3 / 12
NITRIC ACID 42 BAUM
Safety Data Sheet
NITRIC ACID 42 BAUM
Version 1.3
Revision Date: 08/02/2022
Use a water spray to cool fully closed containers.
Special protective equipment for firefighters
: Wear self-contained breathing apparatus for firefighting if necessary. Use personal protective equipment.
SECTION 6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
: Use personal protective equipment.
Environmental precautions
: Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. If the product contaminates rivers and lakes or drains inform respective authorities.
Methods and materials for containment and cleaning up
: Contain spillage, and then collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13).
SECTION 7. HANDLING AND STORAGE
Advice on protection against fire and explosion
: Keep away from combustible material.
Advice on safe handling
: Do not breathe vapours/dust. Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. To avoid spills during handling keep bottle on a metal tray. Dispose of rinse water in accordance with local and national regulations.
Conditions for safe storage
: Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Observe label precautions. Electrical installations / working materials must comply with the technological safety standards.
Materials to avoid
: Do not store near acids.
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Components with workplace control parameters
CAS-No.
Components
Value type
Control parame-
Basis
SDS Number: 100000005010
4 / 12
NITRIC ACID 42 BAUM
Safety Data Sheet
NITRIC ACID 42 BAUM
Version 1.3
Revision Date: 08/02/2022
7697-37-2
Nitric acid
Personal protective equipment Respiratory protection
(Form of exposure) TWA STEL ST
TWA
TWA
TWA
STEL
ters / Permissible concentration 2 ppm 4 ppm 4 ppm 10 mg/m3 2 ppm 5 mg/m3 2 ppm 5 mg/m3 2 ppm 5 mg/m3 4 ppm 10 mg/m3
ACGIH ACGIH NIOSH REL
NIOSH REL
OSHA Z-1
OSHA P0
OSHA P0
: General and local exhaust ventilation is recommended to maintain vapor exposures below recommended limits. Where concentrations are above recommended limits or are unknown, appropriate respiratory protection should be worn. Follow OSHA respirator regulations (29 CFR 1910.134) and use NIOSH/MSHA approved respirators. Protection provided by air purifying respirators against exposure to any hazardous chemical is limited. Use a positive pressure air supplied respirator if there is any potential for uncontrolled release, exposure levels are unknown, or any other circumstance where air purifying respirators may not provide adequate protection.
In the case of vapour formation use a respirator with an approved filter.
Hand protection
Remarks
: The suitability for a specific workplace should be discussed with the producers of the protective gloves.
Eye protection
: Eye wash bottle with pure water Tightly fitting safety goggles Wear face-shield and protective suit for abnormal processing problems.
Skin and body protection
: Impervious clothing Choose body protection according to the amount and concentration of the dangerous substance at the work place.
Hygiene measures
: When using do not eat or drink. When using do not smoke. Wash hands before breaks and at the end of workday.
SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance
: liquid
SDS Number: 100000005010
5 / 12
NITRIC ACID 42 BAUM
Safety Data Sheet
NITRIC ACID 42 BAUM
Version 1.3
Revision Date: 08/02/2022
Colour Odour Odour Threshold pH Freezing Point (Freezing Point) Boiling Point (Boiling point/boiling range) Flash point Evaporation rate Flammability (solid, gas) Upper explosion limit Lower explosion limit Vapour pressure
Relative vapour density Relative density
Density Solubility(ies) Water solubility Solubility in other solvents Partition coefficient: noctanol/water Auto-ignition temperature Thermal decomposition Viscosity
Viscosity, dynamic
: Clear, Colorless, light yellow, brown : pungent, Acrid : 0.75 - 2.5 ppm : <1 : -41 - -20 C (-42 - -4 F)
: 117 - 120 C (243 - 248 F)
: Not applicable : 1
(Butyl Acetate = 1) : No data available : No data available : No data available : 7 - 8 mmHg @ 20 C (68 F)
9 - 10 mmHg @ 25 C (77 F) : > 1(Air = 1.0) : 1.3551 - 1.4078 @ 20 - 25 C (68 - 77 F)
Reference substance: (water = 1) : 1.35 - 1.48 g/cm3 @ 20 C (68 F)
: soluble : No data available : log Pow: -2.3
: No data available : 110 C
: 2 - 2.2 cps @ 20 - 25 C (68 - 77 F)
SECTION 10. STABILITY AND REACTIVITY
SDS Number: 100000005010
6 / 12
NITRIC ACID 42 BAUM
Safety Data Sheet
NITRIC ACID 42 BAUM
Version 1.3
Revision Date: 08/02/2022
Reactivity Chemical stability Possibility of hazardous reactions Conditions to avoid Incompatible materials
Hazardous decomposition products
: No dangerous reaction known under conditions of normal use.
: Stable under normal conditions.
: Corrosive in contact with metals Attacks many metals producing extremely flammable hydrogen gas which can form explosive mixtures with air.
: Keep away from heat, flame, sparks and other ignition sources. Exposure to light. Exposure to moisture
: Acetic anhydride Alcohols Alkali metals Bases carbide Carbon steel chlorates Chromic acid Combustible material Copper Cyanides Metals Organic materials Reducing agents sulfides water halogens
: corrosive vapors Nitrogen oxides (NOx) Ammonia Amines
SECTION 11. TOXICOLOGICAL INFORMATION
Acute toxicity
Product: Acute inhalation toxicity
: Assessment: The component/mixture is toxic after short term inhalation.
Components:
7697-37-2: Acute inhalation toxicity
: LC50 (Rat, male and female): 2500 ppm Exposure time: 1 h Test substance: nitric acid Assessment: The component/mixture is toxic after short term
SDS Number: 100000005010
7 / 12
NITRIC ACID 42 BAUM
Safety Data Sheet
NITRIC ACID 42 BAUM
Version 1.3
inhalation.
Revision Date: 08/02/2022
Skin corrosion/irritation
Product: Remarks: Extremely corrosive and destructive to tissue.
Components:
7697-37-2: Species: Rabbit Result: Causes severe burns.
Serious eye damage/eye irritation
Product: Remarks: May cause irreversible eye damage.
Components:
7697-37-2: Species: Rabbit Result: Risk of serious damage to eyes.
Carcinogenicity IARC
OSHA NTP
ACGIH
No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC.
No component of this product present at levels greater than or equal to 0.1% is on OSHA's list of regulated carcinogens.
No component of this product present at levels greater than or equal to 0.1% is identified as a known or anticipated carcinogen by NTP.
No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by ACGIH.
Further information
Product: Remarks: No data available
SECTION 12. ECOLOGICAL INFORMATION
Ecotoxicity No data available
SDS Number: 100000005010
8 / 12
NITRIC ACID 42 BAUM
Safety Data Sheet
NITRIC ACID 42 BAUM
Version 1.3
Persistence and degradability No data available Bioaccumulative potential No data available
Revision Date: 08/02/2022
Mobility in soil No data available
Other adverse effects Product: Ozone-Depletion Potential
Additional ecological information
: Regulation: 40 CFR Protection of Environment; Part 82 Protection of Stratospheric Ozone - CAA Section 602 Class I Substances Remarks: This product neither contains, nor was manufactured with a Class I or Class II ODS as defined by the U.S. Clean Air Act Section 602 (40 CFR 82, Subpt. A, App.A + B).
: No data available
SECTION 13. DISPOSAL CONSIDERATIONS
Disposal methods Waste from residues
: Dispose of in accordance with all applicable local, state and federal regulations. For assistance with your waste management needs - including disposal, recycling and waste stream reduction, contact Univar Solutions ChemCare: 1-800-637-7922
Contaminated packaging
: Empty remaining contents. Dispose of as unused product. Do not re-use empty containers. Do not burn, or use a cutting torch on, the empty drum.
SECTION 14. TRANSPORT INFORMATION
DOT (Department of Transportation): UN2031, NITRIC ACID SOLUTION, 8 (5.1), II
IATA (International Air Transport Association): UN2031, NITRIC ACID SOLUTION, 8 (5.1), II
SECTION 15. REGULATORY INFORMATION
SDS Number: 100000005010
9 / 12
NITRIC ACID 42 BAUM
Safety Data Sheet
NITRIC ACID 42 BAUM
Version 1.3
WHMIS Classification
: E: Corrosive Material
Revision Date: 08/02/2022
EPCRA - Emergency Planning and Community Right-to-Know Act
CERCLA Reportable Quantity
Components Nitric acid
CAS-No. 7697-37-2
Component RQ (lbs) 1000
SARA 304 Extremely Hazardous Substances Reportable Quantity
Components Nitric acid
CAS-No. 7697-37-2
Component RQ (lbs) 1000
Calculated product RQ (lbs) 1429
Calculated product RQ (lbs) 1429
SARA 311/312 Hazards
: Oxidiser (liquid, solid or gas) Corrosive to metals Acute toxicity (any route of exposure) Skin corrosion or irritation Serious eye damage or eye irritation
SARA 302
: The following components are subject to reporting levels established by SARA Title III, Section 302:
SARA 313
7697-37-2
Nitric acid
: The following components are subject to reporting levels
established by SARA Title III, Section 313:
Clean Air Act
7697-37-2
Nitric acid
This product does not contain any hazardous air pollutants (HAP), as defined by the U.S. Clean Air Act Section 112 (40 CFR 61).
This product does not contain any chemicals listed under the U.S. Clean Air Act Section 112(r) for Accidental Release Prevention (40 CFR 68.130, Subpart F). This product does not contain any chemicals listed under the U.S. Clean Air Act Section 111 SOCMI Intermediate or Final VOC's (40 CFR 60.489).
Clean Water Act
The following Hazardous Substances are listed under the U.S. CleanWater Act, Section 311, Table 116.4A:
7697-37-2
Nitric acid
The following Hazardous Chemicals are listed under the U.S. CleanWater Act, Section 311, Table 117.3:
7697-37-2
Nitric acid
This product does not contain any toxic pollutants listed under the U.S. Clean Water Act Section 307
US State Regulations
Massachusetts Right To Know 7697-37-2
Nitric acid
50 - 70 %
Pennsylvania Right To Know 7697-37-2
Nitric acid
50 - 70 %
New Jersey Right To Know 7697-37-2
Nitric acid
50 - 70 %
SDS Number: 100000005010
10 / 12
NITRIC ACID 42 BAUM
Safety Data Sheet
NITRIC ACID 42 BAUM
Version 1.3
Revision Date: 08/02/2022
California Prop 65
: This product does not contain any chemicals known to State of California to cause cancer, birth defects, or any other reproductive harm.
The components of this product are reported in the following inventories:
TSCA
: On TSCA Inventory
DSL
: All components of this product are on the Canadian DSL
AICS
: On the inventory, or in compliance with the inventory
NZIoC
: On the inventory, or in compliance with the inventory
ENCS
: On the inventory, or in compliance with the inventory
KECI
: On the inventory, or in compliance with the inventory
PICCS
: On the inventory, or in compliance with the inventory
IECSC
: On the inventory, or in compliance with the inventory
SECTION16. OTHER INFORMATION
NFPA:
Flammability
Healt h
0
3
1
OX
OX
Special hazard
Instability
HMIS III:
HEALTH
3/
FLAMMABILITY
1
PHYSICAL HAZARD
4
0 = not significant, 1 =Slight, 2 = Moderate, 3 = High 4 =Extreme, * = Chronic
The information accumulated is based on the data of which we are aware and is believed to be correct as of the date hereof. Since this information may be applied under conditions beyond our control and with which we may be unfamiliar and since data made become available subsequently to the date hereof, we do not assume any responsibility for the results of its use. Recipients are advised to confirm in advance of need that the information is current, applicable, and suitable to their circumstances. This SDS has been prepared by Univar Solutions Product Compliance Department (1-855-429-2661) SDSNA@univarsolutions.com.
Revision Date
: 08/02/2022
SDS Number: 100000005010
11 / 12
NITRIC ACID 42 BAUM
Safety Data Sheet
NITRIC ACID 42 BAUM
Version 1.3
Revision Date: 08/02/2022
Legacy SDS:
: R0001000
Material number: 16159804, 16160140, 16187019, 16175675, 16175673, 16175480, 16175213, 16176867, 16185891, 16185890, 16177631, 16162257, 16140229, 16136928, 16150007, 16145038, 16140587, 16144871, 16149532, 16148905, 16158754, 16145161, 16148826, 16145685, 16160177, 16150182, 16147852, 16140512, 16141265, 16141308, 16142289, 16141518, 16141319, 16141751, 16108058, 16004379, 554152, 554100, 104817, 74151, 105771, 71415, 73143, 89530, 55952, 88705, 55029, 124379, 127750, 156545, 501224, 20223, 20222
Key or legend to abbreviations and acronyms used in the safety data sheet
ACGIH American Conference of Govern- LD50 Lethal Dose 50%
ment Industrial Hygienists
AICS
Australia, Inventory of Chemical
LOAEL Lowest Observed Adverse Effect
Substances
Level
DSL
Canada, Domestic Substances List NFPA National Fire Protection Agency
NDSL Canada, Non-Domestic Substanc- NIOSH National Institute for Occupational
es List
Safety & Health
CNS
Central Nervous System
NTP
National Toxicology Program
CAS
Chemical Abstract Service
NZloC New Zealand Inventory of Chemi-
cals
EC50 Effective Concentration
NOAEL No Observable Adverse Effect
Level
EC50 Effective Concentration 50%
NOEC No Observed Effect Concentration
EGEST EOSCA Generic Exposure Scenar- OSHA Occupational Safety & Health
io Tool
Administration
EOSCA European Oilfield Specialty Chem- PEL
Permissible Exposure Limit
icals Association
EINECS European Inventory of Existing
PICCS Philippines Inventory of Commer-
Chemical Substances
cial Chemical Substances
MAK
Germany Maximum Concentration PRNT Presumed Not Toxic
Values
GHS
Globally Harmonized System
RCRA Resource Conservation Recovery
Act
>=
Greater Than or Equal To
STEL Short-term Exposure Limit
IC50
Inhibition Concentration 50%
SARA Superfund Amendments and
Reauthorization Act.
IARC
International Agency for Research TLV
Threshold Limit Value
on Cancer
IECSC Inventory of Existing Chemical
TWA
Time Weighted Average
Substances in China
ENCS Japan, Inventory of Existing and TSCA Toxic Substance Control Act
New Chemical Substances
KECI
Korea, Existing Chemical Inventory UVCB Unknown or Variable Composi-
tion, Complex Reaction Products,
and Biological Materials
<=
Less Than or Equal To
WHMIS Workplace Hazardous Materials
Information System
LC50
Lethal Concentration 50%
SDS Number: 100000005010
12 / 12
NITRIC ACID 42 BAUM
-BASF
We create chemistry
Chemetall
expect more
Safety Data Sheet
Oakite 61B
Revision date : 2022/12/09
Page: 1/11
Version: 3.0_________________________________________________(30687385/SDS GEN US/EN)
1. Identification
Product identifier used on the label
Oakite 61B
Recommended use of the chemical and restriction on use Recommended use*: Detergents Unsuitable for use: Uses other than recommended
* The "Recommended use" identified for this product is provided solely to comply with a Federal requirement and is not part of the seller's published specification. The terms of this Safety Data Sheet (SDS) do not create or infer any warranty, express or implied, including by incorporation into or reference in the seller's sales agreement.
Details of the supplier of the safety data sheet
Company: Chemetall U.S., Inc. 675 Central Avenue New Providence, NJ 07974 - USA +1 800 526-4473 sds.na-chemetall@basf.com
Emergency telephone number
24 Hour Emergency Response Information CHEMTREC: 800-424-9300, +1-703-527-3887
Other means of identification
Chemical family:
inorganic compounds, organic compounds
2. Hazards Identification
According to Regulation 2012 OSHA Hazard Communication Standard: 29 CFR Part 1910,1200
Classification of the product
Skin Corr./lrrit. Eye Dam./lrrit. STOT SE
1
1
3 (irritating to respiratory system)
Skin corrosion/irritation Serious eye damage/eye irritation Specific target organ toxicity -- single exposure
Safety Data Sheet
Oakite 61B______
Revision date: 2022/12/09 Version: 3.0
Label elements
P< ictogra>m< : $>
Page: 2/11 (30687385/SDS GEN US/EN)
Signal Word: Danger
Hazard Statement: H314 H335
Causes severe skin bums and eye damage. May cause respiratory irritation.
Precautionary Statements (Prevention):
P271
Use only outdoors or in a well-ventilated area.
P280
Wear protective gloves, protective clothing and eye protection or face
protection.
P264
Wash contaminated body parts thoroughly after handling.
P260
Do not breathe dust or mist.
Precautionary Statements (Response):
P303 + P361 + P353 IF ON SKIN (or hair): Remove or Take off immediately all contaminated
clothing. Rinse skin with water or shower.
P305+ P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove
contact lenses, if present and easy to do. Continue rinsing.
P363
Wash contaminated clothing before reuse.
P310
Immediately call a POISON CENTER or physician.
P301 + P330+ P331 IF SWALLOWED: rinse mouth. Do NOT induce vomiting.
P304+ P340
IF INHALED: Remove person to fresh air and keep comfortable for
breathing.
Precautionary Statements (Storage):
P403 + P233
Store in a well-ventilated place. Keep container tightly closed.
P405
Store locked up.
Precautionary Statements (Disposal):
P501
Dispose of contents and container to hazardous or special waste
collection point.
Hazards not otherwise classified
If applicable information is provided in this section on other hazards which do not result in classification but which may contribute to the overall hazards of the substance or mixture.
3. Composition / Information on Ingredients
According to Regulation 2012 OSHA Hazard Communication Standard: 29 CFR Part 1910.1200
sodium carbonate CAS Number: 497-19-8 Content (W/W): >= 25.0 - < 50.0% Synonym: Carbonic acid, disodium salt
Safety Data Sheet
Oakite 61B
Revision date: 2022/12/09 Version: 3.0
Page: 3/11 (30687385/SDS GEN US/EN)
Silicic acid (H2Si03), disodium salt CAS Number: 6834-92-0 Content (W/W): >= 15.0 - < 20.0% Synonym: Disodium metasilicate
Trisodium phosphate CAS Number: 7601-54-9 Content (W/W): >= 5.0 - < 7.0% Synonym: No data available.
Tetrasodium-pyrophosphate CAS Number: 7722-88-5 Content (W/W): >= 5.0 - < 7.0% Synonym: No data available.
Silicic acid, sodium salt CAS Number: 1344-09-8 Content (W/W): >= 3.0 - < 5.0% Synonym: Silicic acid sodium salt
Amides, coco, N-[3-(dimethylamino)propyl], alkylation products with sodium 3-chloro-2hydroxypropanesulfonate
CAS Number: 70851-08-0 Content (W/W): >= 1.0 - < 3.0% Synonym: No data available.
4. First-Aid Measures
Description of first aid measures
General advice: First aid personnel should pay attention to their own safety. If the patient is likely to become unconscious, place and transport in stable sideways position (recovery position). Remove affected person from danger area. Keep warm, calm and covered up. Immediately remove contaminated clothing. Never give anything by mouth to an unconscious person. In case of intoxication, call a poison control center or physician for treatment advice, taking the packaging or the label of the product. Symptoms of poisoning may occur even after several hours, continue medical observation for at least 48 hours after the accident.
If inhaled: Immediate medical attention required. Remove the affected individual into fresh air and keep the person calm. If breathing is irregular or stopped, administer artificial respiration.
If on skin: Flush with copious amounts of water for at least 15 minutes. Remove contaminated clothing immediately and clean before re-use or dispose it if necessary. Immediate medical attention required.
If in eyes: Remove contact lenses, if present. Immediately wash affected eyes for at least 15 minutes under running water with eyelids held open, consult an eye specialist. Immediate medical attention required.
Safety Data Sheet
Oakite 61B
Revision date: 2022/12/09 Version: 3.0___________________________________________________
(30687385/SDS
Page: 4/11 GEN US/EN)
If swallowed: Summon medical aid without delay. Do not induce vomiting due to aspiration hazard. Rinse mouth immediately with water. Keep at rest.
Most important symptoms and effects, both acute and delayed
Symptoms: Information, i.e. additional information on symptoms and effects may be included in the GHS labeling phrases available in Section 2 and in the Toxicological assessments available in Section 11.
Information on: sodium carbonate Symptoms: Overexposure may cause:, vomiting, circulatory collapse, death, diarrhea
Information on: Silicic acid, sodium salt Symptoms: Overexposure may cause:, corneal injury, skin corrosion, severe pain, coughing, respiratory disorders, dyspnea, nausea, headache, vomiting, dizziness, diarrhea, abdominal cramps
Information on: Silicic acid (H2Si03), disodium salt Symptoms: Overexposure may cause:, corneal injury, skin corrosion, severe pain, coughing, respiratory disorders, dyspnea, nausea, headache, vomiting, dizziness, diarrhea, abdominal cramps
Information on: Trisodium phosphate Symptoms: Overexposure may cause:, Eye irritation, skin irritation, erythema, nausea, headache, vomiting, dizziness, diarrhea, abdominal cramps, Inhalation may provoke the following symptoms:, irritation of respiratory tract, coughing
Information on: Tetrasodium-pyrophosphate Symptoms: Overexposure may cause:, corneal injury, skin corrosion, severe pain, coughing, respiratory disorders, dyspnea, nausea, headache, vomiting, dizziness, diarrhea, abdominal cramps
Hazards: Dusts may cause mechanical irritation to eyes. May cause severe burns of the mouth and throat if orally ingested, as well as a danger of perforation of the oesophagus and the stomach.
Indication of any immediate medical attention and special treatment needed
Note to physician Antidote: Treatment:
No known specific antidote. Symptomatic treatment (decontamination, vital functions).
5. Fire-Fighting Measures
Extinguishing media
Suitable extinguishing media: carbon dioxide, alcohol-resistant foam, dry powder, water spray
Unsuitable extinguishing media for safety reasons: water jet
Special hazards arising from the substance or mixture Hazards during fire-fighting: carbon oxides, phosphorus oxides
Safety Data Sheet
Oakite 61B
Revision date: 2022/12/09 Version: 3.0___________________________________________________
(30687385/SDS
Page: 5/11 GEN US/EN)
Fire will produce dense black smoke. Inhalation of dangerous decomposition products may cause serious damage to health.
Advice for fire-fighters Protective equipment for fire-fighting: Appropriate breathing apparatus may be required.
Further information: Cool closed containers in the vicinity of the source of fire. Dispose of fire debris and contaminated extinguishing water in accordance with official regulations. Product itself is non-combustible; fire extinguishing method of surrounding areas must be considered. Collect contaminated extinguishing water separately, do not allow to reach sewage or effluent systems.
6. Accidental release measures
Personal precautions, protective equipment and emergency procedures Do not inhale dusts. For non-emergency personnel: Use personal protective clothing. Ensure adequate ventilation. Keep away from sources of ignition. For emergency responders: Advice on product handling can be found in sections 7 and 8 of this safety data sheet. Information regarding personal protective measures, see section 8.
Environmental precautions Do not allow to enter drains or waterways. Do not discharge into the subsoil/soil. If the product enters drains or sewers, the local water company should be contacted immediately; in the case of contamination of streams, rivers or lakes, the Environment Agency.
Methods and material for containment and cleaning up Avoid dust formation. Contain and collect mechanically and dispose of in accordance with local regulations. Ensure adequate ventilation.
7. Handling and Storage
Precautions for safe handling Avoid dust formation. Protect against moisture. Provide good ventilation of working area (local exhaust ventilation if necessary). Do not return residues to the storage containers. Smoking, eating and drinking are forbidden in application area. For personal protection see section 8. Comply with the health and safety at work laws. The workplace should be equipped with an emergency shower and eye-rinsing facility. Avoid contact with the skin, eyes and clothing. Handle in accordance with good industrial hygiene and safety practice.
Protection against fire and explosion: Avoid dust formation. Avoid all sources of ignition: heat, sparks, open flame. The relevant fire protection measures should be noted.
Conditions for safe storage, including any incompatibilities Keep away from oxidising agents, from strongly alkaline and strongly acid materials.
Further information on storage conditions: Keep container dry. Keep in a cool, well-ventilated place. Protect against moisture. Avoid direct sunlight. Close containers carefully once opened and store them upright in order to prevent any leakage. No smoking. No admission for unauthorised personnel. Always keep in containers of same material as the original one. Observe label precautions.
Safety Data Sheet
Oakite 61B
Revision date: 2022/12/09 Version: 3.0___________________________________________________
(30687385/SDS
Page: 6/11 GEN US/EN)
8. Exposure Controls/Personal Protection No occupational exposure limits known.
Personal protective equipment
Respiratory protection: Respiratory protection required if exposure limit (if available) may be exceeded
Hand protection:
Chemical resistant protective gloves (EN ISO 374-1), butyl rubber gloves - material thickness: 0.5 mm, nitrile rubber (NBR) - 0.4 mm coating thickness, Performance level 6, corresponding to a breakthrough time of >480 min according to EN ISO 374-1, The protection glove should be tested for its specific suitability (e.g. mechanical strength, product compatibility, anti-static properties)., The gloves should be replaced immediately in case of damage or signs of wear. It is recommended to use preventative skin protection (skin cream).
Eye protection:
Tightly fitting safety goggles (splash goggles) (e.g. EN 166)
Body protection:
Chemical resistant protective clothing according to DIN EN 13034 (Type 6)
General safety and hygiene measures:
Eye wash fountains and safety showers must be easily accessible. Avoid inhalation of dusts. Avoid contact with the skin, eyes and clothing. Handle in accordance with good industrial hygiene and safety practice. Ensure adequate ventilation. This can be achieved by the use of local exhaust ventilation and good general extraction. If these are not sufficient to maintain concentrations at the workplace below the occupational exposure limits, appropriate certified respirators must be worn. Remove contaminated clothing immediately and dispose of safely. Hands and/or face should be washed before breaks and at the end of the shift. Keep separated from food stuffs and feed stocks.
9. Physical and Chemical Properties
Form: Odour: Odour threshold: Colour: pH value:
Melting point: Freezing point: onset of boiling: Boiling range: Sublimation point: Flash point: Flammability: Lower explosion limit: Upper explosion limit: Autoignition: Vapour pressure:
Relative density:
solid odourless No applicable information white 11.5-12.5 (40 g/l) not determined not determined not determined not determined No applicable information not applicable not flammable not applicable not applicable not applicable (20 C) not determined No applicable information
available. available. available.
Safety Data Sheet
Oakite 61B
Revision date: 2022/12/09 Version: 3.0___________________________________________________
(30687385/SDS
Page: 7/11 GEN US/EN)
Bulk density:
Vapour density: Partitioning coefficient noctanol/water (log Pow): Viscosity, dynamic: Viscosity, kinematic:
Solubility in water: Miscibility with water: Solubility (quantitative): Solubility (qualitative): Molar mass: Evaporation rate:
0.901 kg/m3 (20 C) No applicable information available. No applicable information available.
No applicable (20 C) not applicable 41 G/L miscible No applicable No applicable No applicable not applicable
information
information information information
available.
available. available. available,
10. Stability and Reactivity
Reactivity No hazardous reactions if stored and handled as prescribed/indicated.
Oxidizing properties: not fire-propagating
Chemical stability The product is stable if stored and handled as prescribed/indicated.
Possibility of hazardous reactions Dust can form an explosive mixture with air.
Conditions to avoid Avoid dust formation. Avoid direct sunlight. Avoid humidity.
Incompatible materials Keep away from highly acidic or alkaline substances as well as oxidants in order to prevent exothermal reactions.
Hazardous decomposition products
Decomposition products: When exposed to high temperatures hazardous decomposition products such as carbon monoxide, carbon dioxide, smoke, oxides of nitrogen may be produced., No hazardous decomposition products if stored and handled as prescribed/indicated.
11. Toxicological information
Primary routes of exposure
Routes of entry for solids and liquids are ingestion and inhalation, but may include eye or skin contact. Routes of entry for gases include inhalation and eye contact. Skin contact may be a route of entry for liquefied gases.
Acute Toxicity/Effects
Acute toxicity
Safety Data Sheet
Oakite 61B
Revision date: 2022/12/09 Version: 3.0___________________________________________________
(30687385/SDS
Page: 8/11 GEN US/EN)
Assessment of acute toxicity: Based on available data, the classification criteria are not met.
Oral Type of value: ATE Value: 7,576 mg/kg The product has not been tested. The statement has been derived from the properties of the individual components.
Inhalation Type of value: ATE Value: > 20 mg/I The product has not been tested. The statement has been derived from the properties of the individual components.
Dermal Type of value: ATE Value: > 2,000 mg/kg The product has not been tested. The statement has been derived from the properties of the individual components.
Assessment other acute effects Assessment of STOT single: Causes temporary irritation of the respiratory tract.
Irritation / corrosion Assessment of irritating effects: Corrosive! Damages skin and eyes. May cause severe damage to the eyes. May cause severe burns of the mouth and throat if orally ingested, as well as a danger of perforation of the oesophagus and the stomach.
Information on: sodium carbonate Assessment of irritating effects: Not irritating to the skin. Eye contact causes irritation.
Information on: Silicic acid, sodium salt Assessment of irritating effects: Corrosive! Damages skin and eyes. Causes temporary irritation of the respiratory tract.
Information on: Silicic acid (H2Si03), disodium salt Assessment of irritating effects: Corrosive! Damages skin and eyes. Causes temporary irritation of the respiratory tract.
Information on: Trisodium phosphate Assessment of irritating effects: Skin contact causes irritation. Eye contact causes irritation.
Sensitization Assessment of sensitization: Based on available data, the classification criteria are not met.
Aspiration Hazard No aspiration hazard expected.
Chronic Toxicity/Effects
Repeated dose toxicity Assessment of repeated dose toxicity: Based on available data, the classification criteria are not met.
Safety Data Sheet
Oakite 61B
Revision date: 2022/12/09 Version: 3.0___________________________________________________
(30687385/SDS
Page: 9/11 GEN US/EN)
Information on: Silicic acid, sodium salt Assessment of repeated dose toxicity: The substance may cause damage to the kidney after repeated ingestion of high doses, as shown in animal studies.
Information on: Silicic acid (H2Si03), disodium salt Assessment of repeated dose toxicity: The substance may lead to shifts in blood composition following repeated exposure in animal experiments. Prolonged and repeated exposure may cause effects on the liver.
Genetic toxicity Assessment of mutagenicity Based on available data, the classification criteria are not met.
Carcinogenicity Assessment of carcinogenicity: Based on available data, the classification criteria are not met.
Reproductive toxicity Assessment of reproduction toxicity: Based on available data, the classification criteria are not met.
Teratogenicity Assessment of teratogenicity: Based on available data, the classification criteria are not met.
12. Ecological Information
Toxicity
Aquatic toxicity Assessment of aquatic toxicity: There are no test results available for this product. Do not allow to enter drains or waterways. Based on available data, the classification criteria are not met.
Persistence and degradability
Assessment biodegradation and elimination (H2Q) No data available concerning biodegradation and elimination.
Bioaccumulative potential
Bioaccumulation potential No data available.
Mobility in soil
Assessment transport between environmental compartments No data available.
13. Disposal considerations
Waste disposal of substance: Do not discharge into drains/surface waters/groundwater. Observe national and local legal requirements.
Safety Data Sheet
Oakite 61B
Revision date: 2022/12/09 Version: 3.0
Page: 10/11 (30687385/SDS GEN US/EN)
Container disposal: Contaminated packaging should be emptied as far as possible and disposed of in the same manner as the substance/product.
14. Transport Information
Land transport USDOT Hazard class: Packing group: ID number: Hazard label: Proper shipping name:
8 III UN 1759 8 CORROSIVE SOLID, N.O.S. (contains disodium metasilicate)
Sea transport IMDG Hazard class: Packing group: ID number: Hazard label: Marine pollutant: Proper shipping name:
8 III UN 1759 8 NO CORROSIVE SOLID, N.O.S. (contains disodium metasilicate)
Air transport IATA/ICAO Hazard class: Packing group: ID number: Hazard label: Proper shipping name:
8 III UN 1759 8 CORROSIVE SOLID, N.O.S. (contains disodium metasilicate)
15. Regulatory Information
Federal Regulations
Registration status:
Chemical
TSCA, US released / listed
EPCRA 311/312 (Hazard categories): Refer to SDS section 2 for GHS hazard classes applicable for this product.
State regulations State RTK NJ
PA
CAS Number 7558-79-4 7758-29-4 7722-88-5 7558-79-4 7758-29-4 7601-54-9 7722-88-5
Chemical name disodium hydrogen orthophosphate Triphosphoric acid, pentasodium salt Tetrasodium-pyrophosphate disodium hydrogen orthophosphate Triphosphoric acid, pentasodium salt Trisodium phosphate T etrasodium-pyrophosphate
Safety Data Sheet
Oakite 61B
Revision date: 2022/12/09 Version: 3.0___________________________________________________
(30687385/SDS
Page: 11/11 GEN US/EN)
NFPA Hazard codes:
Health: 3
Fire: 1
Reactivity: 1
Special:
HMIS III rating
Health: 3
Flammability: 1
Physical hazard: 1
16. Other Information
SDS Prepared by: Chemetall (now part of BASF Group) NA Product Regulations SDS Prepared on: 2022/12/09
We support worldwide Responsible Care initiatives. We value the health and safety of our employees, customers, suppliers and neighbors, and the protection of the environment. Our commitment to Responsible Care is integral to conducting our business and operating our facilities in a safe and environmentally responsible fashion, supporting our customers and suppliers in ensuring the safe and environmentally sound handling of our products, and minimizing the impact of our operations on society and the environment during production, storage, transport, use and disposal of our products.
IMPORTANT: WHILE THE DESCRIPTIONS, DESIGNS, DATA AND INFORMATION CONTAINED HEREIN ARE PRESENTED IN GOOD FAITH AND BELIEVED TO BE ACCURATE , IT IS PROVIDED FOR YOUR GUIDANCE ONLY. BECAUSE MANY FACTORS MAY AFFECT PROCESSING OR APPLICATION/USE, WE RECOMMEND THAT YOU MAKE TESTS TO DETERMINE THE SUITABILITY OF A PRODUCT FOR YOUR PARTICULAR PURPOSE PRIOR TO USE. NO WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE MADE REGARDING PRODUCTS DESCRIBED OR DESIGNS, DATA OR INFORMATION SET FORTH, OR THAT THE PRODUCTS, DESIGNS, DATA OR INFORMATION MAY BE USED WITHOUT INFRINGING THE INTELLECTUAL PROPERTY RIGHTS OF OTHERS. IN NO CASE SHALL THE DESCRIPTIONS, INFORMATION, DATA OR DESIGNS PROVIDED BE CONSIDERED A PART OF OUR TERMS AND CONDITIONS OF SALE. FURTHER, YOU EXPRESSLY UNDERSTAND AND AGREE THAT THE DESCRIPTIONS, DESIGNS, DATA, AND INFORMATION FURNISHED BY OUR COMPANY HEREUNDER ARE GIVEN GRATIS AND WE ASSUME NO OBLIGATION OR LIABILITY FOR THE DESCRIPTION, DESIGNS, DATA AND INFORMATION GIVEN OR RESULTS OBTAINED, ALL SUCH BEING GIVEN AND ACCEPTED AT YOUR RISK. END OF DATASHEET
Safety Data Sheet
Oakite 160
Version 0.1
Revision Date 05/29/2015
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION
Product name
: Oakite 160
Substance number
: REL_1600
#120
Print Date 05/29/2015
Chemical usage
: Cleaning Compound, Metal etching.
Manufacturer or supplier's details
Company
: Chemetall US, Inc.
Address
Telephone Telefax Emergency telephone no
: 675 Central Avenue New Providence NJ 07974
: (800) 526-4473 : (908) 464-4658 : CHEMTREC - 800-424-9300, 1-703-527-3887 (International)
SECTION 2. HAZARDS IDENTIFICATION
Emergency Overview Appearance Colour Odour Hazard Summary
powder
white
none
Causes severe burns. Harmful if swallowed.
GHS Classification Acute toxicity (Dermal)
Skin corrosion
Serious eye damage
: Category 4 : Category 1A : Category 1
GHS Label element
Hazard pictograms
:
Signal word Hazard statements
Precautionary statements
: Danger : Harmful in contact with skin.
Causes severe skin burns and eye damage. : Prevention:
1 / 9
Safety Data Sheet
Oakite 160
Version 0.1
Potential Health Effects Inhalation Skin Ingestion Aggravated Medical Condition Carcinogenicity: IARC ACGIH OSHA NTP
Revision Date 05/29/2015
Print Date 05/29/2015
Do not breathe dust or mist. Wash skin thoroughly after handling. Wear protective gloves/ protective clothing/ eye protection/ face protection. Response: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. IF ON SKIN (or hair): Remove/ Take off immediately all contaminated clothing. Rinse skin with water/ shower. IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Immediately call a POISON CENTER or doctor/ physician. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/ physician. Wash contaminated clothing before reuse. Storage: Store locked up. Disposal: Dispose of contents/ container to an approved waste disposal plant.
: no : yes : yes : None known.
No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC.
No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by ACGIH.
No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by OSHA.
No component of this product present at levels greater than or equal to 0.1% is identified as a known or anticipated carcinogen by NTP.
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Substance / Mixture
:
2 / 9
Safety Data Sheet
Oakite 160
Version 0.1
Revision Date 05/29/2015
Print Date 05/29/2015
Hazardous components
Component
CAS-No.
Weight percent
Sodium hydroxide
1310-73-2 70 - 90
Trade Secret Registry
735517-5122P 5 - 10
Unidentified ingredients are considered not hazardous under Federal Hazard Communication
Standard (29CFR 1910.1200).
Specific chemical identity of composition has been withheld as a trade secret.
Exact percentage of composition has been withheld as a trade secret.
SECTION 4. FIRST AID MEASURES
If inhaled
: Remove to fresh air. If symptoms persist, call a physician. If breathing is irregular or stopped, administer artificial respiration.
In case of skin contact
: Wash off immediately with plenty of water for at least 15 minutes. Take off contaminated clothing and shoes immediately. Get medical attention immediately if irritation develops and persists
In case of eye contact
: Rinse immediately with plenty of water for at least 15 minutes. Keep eye wide open while rinsing. Get medical attention immediately
If swallowed
: Rinse mouth. Drink plenty of water. Never give anything by mouth to an unconscious person. Get medical attention immediately
SECTION 5. FIREFIGHTING MEASURES
Suitable extinguishing media
: Carbon dioxide (CO2) Dry chemical Foam
Special protective equipment : In the event of fire, wear self-contained breathing apparatus. for firefighters
SECTION 6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures Methods and materials for containment and cleaning up
: Material can create slippery conditions.
: Pick up and arrange disposal without creating dust. Keep in suitable, closed containers for disposal.
Additional advice
: Never return spills in original containers for re-use.
3 / 9
Safety Data Sheet
Oakite 160
Version 0.1
Revision Date 05/29/2015
Print Date 05/29/2015
SECTION 7. HANDLING AND STORAGE
Advice on safe handling
: Add this product to surface of solution slowly to avoid spattering Do not add large amounts of product to solution at any one time. Do not add to hot water warmer than 43 degrees to 49 degrees C (110 degrees to 120 degrees F). Never add liquids to product
Conditions for safe storage
: Keep containers dry and tightly closed to avoid moisture absorption and contamination. Store indoors in a cool, well-ventilated place Protect from direct contact with water or excessive moisture.
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Components with workplace control parameters
Components
CAS-No.
Value type (Form of exposure)
Sodium hydroxide
1310-73-2
C C TWA C
Control parameters / Permissible concentration 2.000000 mg/m3 2.000000 mg/m3 2.000000 mg/m3 2.000000 mg/m3
Basis
ACGIH NIOSH REL OSHA Z-1 OSHA P0
Personal protective equipment
Respiratory protection
: If the occupational exposure limits cannot be met, suitable respirator equipment shall be worn.
Hand protection Remarks
Eye protection
Skin and body protection
Hygiene measures
: Impervious gloves
: Chemical resistant goggles must be worn.
: Rubber or plastic apron
: Avoid contact with skin, eyes and clothing. Wear suitable gloves and eye/face protection. Wear suitable protective clothing. Wash hands before breaks and immediately after handling the product. Provide adequate ventilation. Avoid breathing dust or vapor. Keep away from food and drink.
4 / 9
Safety Data Sheet
Oakite 160
Version 0.1
Revision Date 05/29/2015
SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance
: powder
Colour Odour pH Melting point/range Boiling point/boiling range Flash point
Evaporation rate
: white : none : 13.5, Concentration: 40.00000 g/l : no data available : no data available :
does not flash : GLP: No information available.
Upper explosion limit Lower explosion limit Vapour pressure Relative density Bulk density Solubility(ies) Water solubility
: Not applicable. : Not applicable. : no data available : not applicable : 74.81 lb/ft3
: 150.00000 g/l (77 C)
Partition coefficient: noctanol/water Auto-ignition temperature Thermal decomposition Viscosity, dynamic
: no data available
: No data available : No data available : No data available
Print Date 05/29/2015
SECTION 10. STABILITY AND REACTIVITY
Conditions to avoid
Incompatible materials
Hazardous decomposition products
: Exposure to moisture. : Acids : Hydrogen, by reaction with metals
SECTION 11. TOXICOLOGICAL INFORMATION Acute toxicity
Product:
5 / 9
Safety Data Sheet
Oakite 160
Version 0.1
Acute oral toxicity
Revision Date 05/29/2015
Print Date 05/29/2015
: Acute toxicity estimate : 4,223.000000 mg/kg Method: Calculation method
Acute inhalation toxicity
: Acute toxicity estimate : > 10.000000 mg/l Exposure time: 4 h Test atmosphere: dust/mist Method: Calculation method
Acute dermal toxicity
: Acute toxicity estimate : 1,552.000000 mg/kg Method: Calculation method
Components:
Sodium hydroxide: Acute oral toxicity
: LD50 mouse: 6,600.000000 mg/kg
LD50 rat: 4,090.000000 mg/kg
Acute inhalation toxicity
: LC50 mouse: 1,200.000000 mg/l Exposure time: 2 h Test atmosphere: dust/mist
LC50 rat: 2,300.000000 mg/l Exposure time: 2 h Test atmosphere: dust/mist
Acute dermal toxicity
: LD50 rabbit: 1,350.000000 mg/kg
Trade Secret Registry: Acute oral toxicity
: LD50 rat: 4,090.000000 mg/kg
LD50 mouse: 6,600.000000 mg/kg
Acute inhalation toxicity
: LC50 rat: 2.300000 mg/l Exposure time: 4 h Test atmosphere: dust/mist
LC50 mouse: 1.200000 mg/l Exposure time: 2 h Test atmosphere: dust/mist
Skin corrosion/irritation
Components:
Sodium hydroxide: Result: Corrosive
Serious eye damage/eye irritation Components: Sodium hydroxide:
6 / 9
Safety Data Sheet
Oakite 160
Version 0.1
Result: Corrosive Classification: Corrosive
Respiratory or skin sensitisation no data available Germ cell mutagenicity no data available Carcinogenicity no data available
Reproductive toxicity no data available
STOT - single exposure no data available
STOT - repeated exposure no data available Aspiration toxicity no data available
Revision Date 05/29/2015
Print Date 05/29/2015
SECTION 12. ECOLOGICAL INFORMATION Ecotoxicity
no data available Bioaccumulative potential
Product:
Partition coefficient: noctanol/water
Other adverse effects
: Remarks: no data available
SECTION 13. DISPOSAL CONSIDERATIONS
Disposal methods Waste from residues
: Refer to all federal, provincial, state and local regulation prior to disposition of container and unused contents by reuse, recycle or disposal.
SECTION 14. TRANSPORT INFORMATION International regulation
7 / 9
Safety Data Sheet
Oakite 160
Version 0.1
Revision Date 05/29/2015
Print Date 05/29/2015
Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code Not applicable for product as supplied.
National Regulations
SECTION 15. REGULATORY INFORMATION
TSCA Status
: All components of this material comply with US TSCA requirements.
OSHA Hazards WHMIS Classification
: Combustible dust, Toxic by inhalation., Harmful by skin absorption., Corrosive to skin
: E: Corrosive Material
EPCRA - Emergency Planning and Community Right-to-Know Act
CERCLA Reportable Quantity Components Sodium hydroxide
CAS-No. 1310-73-2
Component RQ Calculated product RQ
(lbs)
(lbs)
1,000
1,149
SARA 311/312 Hazards
: Acute Health Hazard
SARA 302 SARA 313
: SARA 302: No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.
: SARA 313: This material does not contain any chemical components with known CAS numbers that exceed the threshold (De Minimis) reporting levels established by SARA Title III, Section 313.
US State Regulations Massachusetts Right To Know
Sodium hydroxide
Pennsylvania Right To Know Sodium hydroxide Trade Secret Registry Trade Secret Registry
New Jersey Right To Know Sodium hydroxide Trade Secret Registry Trade Secret Registry
1310-73-2
1310-73-2 735517-5122P 735517-5145P
1310-73-2 735517-5122P 735517-5145P
8 / 9
Safety Data Sheet
Oakite 160
Version 0.1
NFPA:
Flammability
0
3
1
Health
Special hazard.
Instability
Revision Date 05/29/2015
Print Date 05/29/2015
HMIS III:
HEALTH
3
FLAMMABILITY
0
PHYSICAL HAZARD
1
0 = not significant, 1 =Slight, 2 = Moderate, 3 = High 4 = Extreme, * = Chronic
Corrosive Alkaline SECTION 16. OTHER INFORMATION
Safety Glasses, Gloves, Apron, Dust Respirator
Further information
Version 1.0 Revision Date 05/29/2015
Chemetall US, Inc. warrants that the products described herein will conform with its published specifications.
The products supplied by Chemetall and information related to them are intended for use by buyers having necessary industrial skill and knowledge. Buyers should undertake sufficient verification and testing to determine the suitability of the Chemetall materials for their own particular purpose. Since buyer's conditions of use of products are beyond Chemetall's control, Chemetall does not warrant any recommendations and information for the use of such products. CHEMETALL DISCLAIMS ALL OTHER WARRANTIES INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE IN CONNECTION WITH THE USE OF ITS PRODUCTS.
9 / 9
#514
Safety Data Sheet
SULFURIC ACID
Version 1.1
Revision Date: 09/01/2019
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION
Product name
: SULFURIC ACID
Recommended use of the chemical and restrictions on use
Recommended use
: industrial chemical
Manufacturer or supplier's details
Company
: Univar Solutions USA, Inc.
Address
3075 Highland Pkwy Suite 200
Downers Grove, IL 60515
United States of America (USA)
Emergency telephone number:
Transport North America: CHEMTREC (1-800-424-9300)
CHEMTREC INTERNATIONAL Tel # 703-527-3887
Additional Information:
: Responsible Party: Product Compliance Department E-mail: SDSNA@univarsolutions.com SDS Requests: 1-855-429-2661 Website: www.univarsolutions.com
SECTION 2. HAZARDS IDENTIFICATION
GHS Classification Skin corrosion
Serious eye damage
: Category 1A : Category 1
GHS label elements
Hazard pictograms
:
Signal word Hazard statements Precautionary statements
SDS Number: 100000025928
: Danger
: H314 Causes severe skin burns and eye damage.
: Prevention: P264 Wash skin thoroughly after handling. P280 Wear protective gloves/ protective clothing/ eye protection/ face protection. Response: P301 + P330 + P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P304 + P340 + P310 IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor. P305 + P351 + P338 + P310 IF IN EYES: Rinse cautiously with
1 / 11
SULFURIC ACID
Safety Data Sheet
SULFURIC ACID
Version 1.1
Revision Date: 09/01/2019
water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor. P363 Wash contaminated clothing before reuse. Storage: P405 Store locked up. Disposal: P501 Dispose of contents/ container to an approved waste disposal plant.
Other hazards None known.
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Substance / Mixture
: Substance
Hazardous components
CAS-No.
Chemical name
7664-93-9
Sulfuric acid
Any Concentration shown as a range is due to batch variation.
Weight percent 50 - 70
SECTION 4. FIRST AID MEASURES
General advice
: Move out of dangerous area. Consult a physician. Show this safety data sheet to the doctor in attendance. Do not leave the victim unattended.
If inhaled
: If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.
In case of skin contact
: Immediate medical treatment is necessary as untreated wounds from corrosion of the skin heal slowly and with difficulty. If on skin, rinse well with water. If on clothes, remove clothes.
In case of eye contact
: Small amounts splashed into eyes can cause irreversible tissue damage and blindness. In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Continue rinsing eyes during transport to hospital. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
If swallowed
: Clean mouth with water and drink afterwards plenty of water. Keep respiratory tract clear.
SDS Number: 100000025928
2 / 11
SULFURIC ACID
Safety Data Sheet
SULFURIC ACID
Version 1.1
Revision Date: 09/01/2019
Do NOT induce vomiting. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Take victim immediately to hospital.
SECTION 5. FIREFIGHTING MEASURES
Suitable extinguishing media
: Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Unsuitable extinguishing media
: High volume water jet
Specific hazards during firefighting
: Do not allow run-off from fire fighting to enter drains or water courses.
Hazardous combustion products
: sulfur oxides Gases hazardous to health may be formed. Sulphuric acid
Further information
: Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.
Special protective equipment : Wear self-contained breathing apparatus for firefighting if nec-
for firefighters
essary.
SECTION 6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
: Use personal protective equipment.
Environmental precautions
: Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. If the product contaminates rivers and lakes or drains inform respective authorities.
Methods and materials for containment and cleaning up
: Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Keep in suitable, closed containers for disposal.
SECTION 7. HANDLING AND STORAGE
Advice on protection against fire and explosion
: Normal measures for preventive fire protection.
Advice on safe handling
: Do not breathe vapours/dust.
SDS Number: 100000025928
3 / 11
SULFURIC ACID
Safety Data Sheet
SULFURIC ACID
Version 1.1
Conditions for safe storage
Materials to avoid
Revision Date: 09/01/2019
Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. To avoid spills during handling keep bottle on a metal tray. Dispose of rinse water in accordance with local and national regulations.
: Keep container tightly closed in a dry and well-ventilated place. Observe label precautions. Electrical installations / working materials must comply with the technological safety standards.
: Do not store near acids.
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Components with workplace control parameters
CAS-No.
Components
7664-93-9
Sulfuric acid
Value type (Form of exposure) TWA (Thoracic fraction) TWA TWA TWA
Control parameters / Permissible concentration 0.2 mg/m3
1 mg/m3 1 mg/m3 1 mg/m3
Basis
ACGIH NIOSH REL OSHA Z-1 OSHA P0
Personal protective equipment Respiratory protection
: General and local exhaust ventilation is recommended to maintain vapor exposures below recommended limits. Where concentrations are above recommended limits or are unknown, appropriate respiratory protection should be worn. Follow OSHA respirator regulations (29 CFR 1910.134) and use NIOSH/MSHA approved respirators. Protection provided by air purifying respirators against exposure to any hazardous chemical is limited. Use a positive pressure air supplied respirator if there is any potential for uncontrolled release, exposure levels are unknown, or any other circumstance where air purifying respirators may not provide adequate protection.
Hand protection
Remarks
: The suitability for a specific workplace should be discussed with the producers of the protective gloves.
Eye protection
: Eye wash bottle with pure water Tightly fitting safety goggles Wear face-shield and protective suit for abnormal processing problems.
Skin and body protection
: Impervious clothing Choose body protection according to the amount and concen-
SDS Number: 100000025928
4 / 11
SULFURIC ACID
Safety Data Sheet
SULFURIC ACID
Version 1.1
Hygiene measures
Revision Date: 09/01/2019
tration of the dangerous substance at the work place.
: When using do not eat or drink. When using do not smoke. Wash hands before breaks and at the end of workday.
SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance
: liquid
Colour
: colourless, cloudy
Odour
: odourless
Odour Threshold
: No data available
pH
: < 1.0
Freezing Point (Freezing Point)
: 3 C (37 F)
Boiling Point (Boiling point/boiling range)
: 329.44 C (624.99 F)
Flash point
: No data available
Evaporation rate
: No data available
Flammability (solid, gas)
: No data available
Upper explosion limit
: No data available
Lower explosion limit
: No data available
Vapour pressure
: 1.0 mmHg @ 20 C (68 F)
Relative vapour density
: 3.4(Air = 1.0)
Relative density
: 1.403 @ 20 C (68 F) Reference substance: (water = 1)
Density
: No data available
Solubility(ies) Water solubility
: completely soluble
Solubility in other solvents
: No data available
Partition coefficient: noctanol/water
: No data available
Auto-ignition temperature
: No data available
SDS Number: 100000025928
5 / 11
SULFURIC ACID
Safety Data Sheet
SULFURIC ACID
Version 1.1
Thermal decomposition
: 340 C
Revision Date: 09/01/2019
SECTION 10. STABILITY AND REACTIVITY
Reactivity
: No dangerous reaction known under conditions of normal use.
Chemical stability
: Stable under normal conditions.
Possibility of hazardous reactions
: No hazards to be specially mentioned.
Conditions to avoid
: Keep away from heat, flame, sparks and other ignition sources.
Incompatible materials
: acetylenes Acids Ammonia Combustible material Flammable materials Metals nitrates Nitriles nitrites Organic materials Oxidizing agents phosphorus Powdered metals Reducing agents water Peroxides
SECTION 11. TOXICOLOGICAL INFORMATION
Skin corrosion/irritation Product: Remarks: Extremely corrosive and destructive to tissue.
Components: 7664-93-9: Species: Rabbit Result: Causes severe burns.
Serious eye damage/eye irritation Product:
SDS Number: 100000025928
6 / 11
SULFURIC ACID
Safety Data Sheet
SULFURIC ACID
Version 1.1
Remarks: May cause irreversible eye damage.
Revision Date: 09/01/2019
Components:
7664-93-9: Species: Rabbit Result: Risk of serious damage to eyes.
Germ cell mutagenicity
Components: 7664-93-9: Genotoxicity in vitro
: Test Type: Ames test Species: Salmonella typhimurium Metabolic activation: with and without metabolic activation Result: negative
Carcinogenicity IARC
OSHA
NTP
ACGIH
Group 1: Carcinogenic to humans
7664-93-9
Sulfuric acid
Group 1: Carcinogenic to humans
No component of this product present at levels greater than or equal to 0.1% is on OSHA's list of regulated carcinogens.
No component of this product present at levels greater than or equal to 0.1% is on OSHA's list of regulated carcinogens.
Known to be human carcinogen
7664-93-9
Sulfuric acid
Known to be human carcinogen
Suspected human carcinogen
7664-93-9
Sulfuric acid
Further information
Product: Remarks: No data available
SECTION 12. ECOLOGICAL INFORMATION
Ecotoxicity No data available
SDS Number: 100000025928
7 / 11
SULFURIC ACID
Safety Data Sheet
SULFURIC ACID
Version 1.1
Persistence and degradability No data available Bioaccumulative potential No data available
Revision Date: 09/01/2019
Mobility in soil No data available
Other adverse effects Product: Ozone-Depletion Potential
Additional ecological information
: Regulation: 40 CFR Protection of Environment; Part 82 Protection of Stratospheric Ozone - CAA Section 602 Class I Substances Remarks: This product neither contains, nor was manufactured with a Class I or Class II ODS as defined by the U.S. Clean Air Act Section 602 (40 CFR 82, Subpt. A, App.A + B).
: No data available
SECTION 13. DISPOSAL CONSIDERATIONS
Disposal methods Waste from residues
: Dispose of in accordance with all applicable local, state and federal regulations. For assistance with your waste management needs - including disposal, recycling and waste stream reduction, contact Univar Solutions ChemCare: 1-800-909-4897
Contaminated packaging
: Empty remaining contents. Dispose of as unused product. Do not re-use empty containers.
SECTION 14. TRANSPORT INFORMATION
DOT (Department of Transportation): UN2796, Sulfuric acid, 8, II
IATA (International Air Transport Association): UN2796, SULPHURIC ACID, 8, II
IMDG (International Maritime Dangerous Goods): UN2796, SULPHURIC ACID, 8, II
SDS Number: 100000025928
8 / 11
SULFURIC ACID
Safety Data Sheet
SULFURIC ACID
Version 1.1
Revision Date: 09/01/2019
SECTION 15. REGULATORY INFORMATION
EPCRA - Emergency Planning and Community Right-to-Know Act
CERCLA Reportable Quantity
Components Sulfuric acid
CAS-No. 7664-93-9
Component RQ (lbs) 1000
SARA 304 Extremely Hazardous Substances Reportable Quantity
Components Sulfuric acid
CAS-No. 7664-93-9
Component RQ (lbs) 1000
Calculated product RQ (lbs) 2000
Calculated product RQ (lbs) 2000
SARA 311/312 Hazards
: Acute Health Hazard
SARA 302
: The following components are subject to reporting levels established by SARA Title III, Section 302:
SARA 313
7664-93-9
Sulfuric acid
: The following components are subject to reporting levels
established by SARA Title III, Section 313:
Clean Air Act
7664-93-9
Sulfuric acid
This product does not contain any hazardous air pollutants (HAP), as defined by the U.S. Clean Air Act Section 112 (40 CFR 61).
This product does not contain any chemicals listed under the U.S. Clean Air Act Section 112(r) for Accidental Release Prevention (40 CFR 68.130, Subpart F). This product does not contain any chemicals listed under the U.S. Clean Air Act Section 111 SOCMI Intermediate or Final VOC's (40 CFR 60.489).
Clean Water Act
The following Hazardous Substances are listed under the U.S. CleanWater Act, Section 311, Table 116.4A:
7664-93-9
Sulfuric acid
The following Hazardous Chemicals are listed under the U.S. CleanWater Act, Section 311, Table 117.3:
7664-93-9
Sulfuric acid
This product does not contain any toxic pollutants listed under the U.S. Clean Water Act Section 307
Massachusetts Right To Know 7664-93-9
Sulfuric acid
Pennsylvania Right To Know 7664-93-9 7732-18-5
Sulfuric acid Water
California Prop 65
WARNING: This product can expose you to chemicals including Sulfuric acid, which is/are known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov.
SDS Number: 100000025928
9 / 11
SULFURIC ACID
Safety Data Sheet
SULFURIC ACID
Version 1.1
Revision Date: 09/01/2019
The components of this product are reported in the following inventories:
TSCA
: On TSCA Inventory
SECTION16. OTHER INFORMATION
NFPA:
Flammability
1
3
0
Healt h
Special hazard.
Instability
HMIS III:
HEALTH
3
FLAMMABILITY
1
PHYSICAL HAZARD
0
0 = not significant, 1 =Slight, 2 = Moderate, 3 = High 4 =Extreme, * = Chronic
The information accumulated is based on the data of which we are aware and is believed to be correct as of the date hereof. Since this information may be applied under conditions beyond our control and with which we may be unfamiliar and since data made become available subsequently to the date hereof, we do not assume any responsibility for the results of its use. Recipients are advised to confirm in advance of need that the information is current, applicable, and suitable to their circumstances. This SDS has been prepared by Univar Solutions Product Compliance Department (1-855-429-2661) SDSNA@univarsolutions.com.
Revision Date
: 09/01/2019
Legacy SDS:
: R0017947
Material number: 16125824, 16114349, 696270, 74735, 59641
Key or legend to abbreviations and acronyms used in the safety data sheet
ACGIH American Conference of Govern- LD50 Lethal Dose 50%
ment Industrial Hygienists
AICS
Australia, Inventory of Chemical
LOAEL Lowest Observed Adverse Effect
Substances
Level
DSL
Canada, Domestic Substances List NFPA National Fire Protection Agency
NDSL Canada, Non-Domestic Substanc- NIOSH National Institute for Occupational
es List
Safety & Health
CNS
Central Nervous System
NTP
National Toxicology Program
CAS
Chemical Abstract Service
NZloC New Zealand Inventory of Chemi-
cals
SDS Number: 100000025928
10 / 11
SULFURIC ACID
Safety Data Sheet
SULFURIC ACID
Version 1.1
Revision Date: 09/01/2019
EC50 EC50 EGEST EOSCA EINECS MAK GHS >= IC50 IARC IECSC ENCS KECI
<= LC50
Effective Concentration
NOAEL
Effective Concentration 50% EOSCA Generic Exposure Scenario Tool European Oilfield Specialty Chemicals Association European Inventory of Existing Chemical Substances Germany Maximum Concentration Values Globally Harmonized System
NOEC OSHA PEL PICCS PRNT RCRA
Greater Than or Equal To Inhibition Concentration 50%
STEL SARA
International Agency for Research on Cancer Inventory of Existing Chemical Substances in China Japan, Inventory of Existing and New Chemical Substances Korea, Existing Chemical Inventory
TLV TWA TSCA UVCB
Less Than or Equal To Lethal Concentration 50%
WHMIS
No Observable Adverse Effect Level No Observed Effect Concentration Occupational Safety & Health Administration Permissible Exposure Limit
Philippines Inventory of Commercial Chemical Substances Presumed Not Toxic
Resource Conservation Recovery Act Short-term Exposure Limit Superfund Amendments and Reauthorization Act. Threshold Limit Value
Time Weighted Average
Toxic Substance Control Act
Unknown or Variable Composition, Complex Reaction Products, and Biological Materials Workplace Hazardous Materials Information System
SDS Number: 100000025928
11 / 11
SULFURIC ACID
Coxsackie, New York
Work Instruction: WI-00237 RCRA Contingency Plan - EMS
Last Reviewed Date: 10/24/23 Revision No.: D
Spine
Page: 33 of 33
WI-00237 RCRA Contingency Plan Ducommun AeroStructures New York Coxsackie, NY
Attachment 09 Emergency Responders Receipts
McCoy, Mary
From: Sent: To: Subject:
Shawn Burdick - Village of Coxsackie <firechief@villageofcoxsackie.com> Tuesday, January 24, 2023 10:44 AM McCoy, Mary Re: Site Visit
This email originated from outside Ducommun. Hover your mouse over any link to verify it. Do not click any links or open any attachments unless you trust the sender and know the content is safe.
See you February 1 at 6:30pm Chief Shawn Burdick Firechief@villageofcoxsackie.com (518)-242-0032
On Jan 24, 2023, at 10:40 AM, McCoy, Mary <MMcCoy@ducommun.com> wrote:
This email comes from outside the organization.
Do not click links or open attachments unless it is an email you expected to receive.
February 1? M
Mary A. McCoy, PE 203.300.7303 cell
From: Shawn Burdick - Village of Coxsackie [mailto:firechief@villageofcoxsackie.com] Sent: Tuesday, January 24, 2023 10:39 AM To: McCoy, Mary <MMcCoy@ducommun.com> Subject: Re: Site Visit
This email originated from outside Ducommun. Hover your mouse over any link to verify it. Do not click any links or open any attachments unless you trust the sender and know the content is safe.
We already have Wednesday scheduled. It will have to be another day
Chief Shawn Burdick Firechief@villageofcoxsackie.com (518)-242-0032
1 Attachment 9 Page 1 of 29
On Jan 24, 2023, at 7:51 AM, McCoy, Mary <MMcCoy@ducommun.com> wrote:
This email comes from outside the organization.
Do not click links or open attachments unless it is an email you expected to receive.
Great! See you then. M
Mary A. McCoy, PE 203.300.7303 cell
From: Shawn Burdick - Village of Coxsackie [mailto:firechief@villageofcoxsackie.com] Sent: Tuesday, January 24, 2023 7:34 AM To: McCoy, Mary <MMcCoy@ducommun.com> Cc: Buccino, Charles <CBuccino@ducommun.com>; Roque, Gregory <GRoque@ducommun.com> Subject: Re: Site Visit
This email originated from outside Ducommun. Hover your mouse over any link to verify it. Do not click any links or open any attachments unless you trust the sender and know the content is safe.
We already have something scheduled this Wednesday. Chief Shawn Burdick Firechief@villageofcoxsackie.com (518)-242-0032
On Jan 24, 2023, at 7:11 AM, McCoy, Mary <MMcCoy@ducommun.com> wrote:
This email comes from outside the organization.
Do not click links or open attachments unless it is an email you expected to receive.
Hi Shawn, Does this time still work for you?
2 Attachment 9 Page 2 of 29
M
Mary A. McCoy, PE 203.300.7303 cell
From: McCoy, Mary Sent: Friday, January 20, 2023 1:36 PM To: Shawn Burdick - Village of Coxsackie <firechief@villageofcoxsackie.com> Cc: Buccino, Charles <CBuccino@ducommun.com>; Roque, Gregory <GRoque@ducommun.com> Subject: RE: Site Visit
How about January 25, Wednesday, at 6:30 pm?
M
Mary A. McCoy, PE 203.300.7303 cell
From: McCoy, Mary Sent: Friday, January 20, 2023 8:50 AM To: Shawn Burdick - Village of Coxsackie <firechief@villageofcoxsackie.com> Subject: RE: Site Visit
No worries. Let me find out.
M
Mary A. McCoy, PE 203.300.7303 cell
From: Shawn Burdick - Village of Coxsackie [mailto:firechief@villageofcoxsackie.com] Sent: Wednesday, January 18, 2023 4:44 PM To: McCoy, Mary <MMcCoy@ducommun.com> Subject: Re: Site Visit
This email originated from outside Ducommun. Hover your mouse over any link to verify it. Do not click any links or open any attachments unless you trust the sender and know the content is safe.
When we did site visits in the past they have been on Wednesday evenings at 6:30pm, will this work? Sorry it took so long to reply it's been a busy week.
Chief Shawn Burdick Firechief@villageofcoxsackie.com
3 Attachment 9 Page 3 of 29
(518)-242-0032
On Jan 13, 2023, at 2:08 PM, McCoy, Mary <MMcCoy@ducommun.com> wrote:
This email comes from outside the organization.
Do not click links or open attachments unless it is an email you expected to receive.
Greetings,
My name is Mary McCoy, and I'm the new EHS Manager at Ducommun here in Coxsackie.
I'd like to invite your team for a visit of our site and to discuss a few things.
Are you available on any Friday after 2 pm?
Mary A. McCoy, PE EHS Manager
Ducommun AeroStructures New York, Inc. 171 Stacey Road Coxsackie, NY 12051-2613 203.300.7303 cell 518.731.4650 office mmccoy@ducommun.com www.ducommun.com
CONFIDENTIALITY NOTICE: This email transmission and any attachments to it may contain confidential information proprietary to Ducommun Incorporated and its subsidiaries or their customers. If you are not the intended recipient, a person responsible for delivering it to the intended recipient, or have received this transmission in error, please notify the sender and destroy the original transmission and its attachments without reading or saving. CONFIDENTIALITY NOTICE: This email transmission and any attachments to it may contain confidential information proprietary to Ducommun Incorporated and its subsidiaries or their customers. If you are not the intended recipient, a person responsible for delivering it to the intended recipient, or have received this transmission in error, please notify the sender and destroy the original transmission and its attachments without reading or saving. CONFIDENTIALITY NOTICE: This email transmission and any attachments to it may contain confidential information proprietary to Ducommun Incorporated
4 Attachment 9 Page 4 of 29
and its subsidiaries or their customers. If you are not the intended recipient, a person responsible for delivering it to the intended recipient, or have received this transmission in error, please notify the sender and destroy the original transmission and its attachments without reading or saving.
CONFIDENTIALITY NOTICE: This email transmission and any attachments to it may contain confidential information proprietary to Ducommun Incorporated and its subsidiaries or their customers. If you are not the intended recipient, a person responsible for delivering it to the intended recipient, or have received this transmission in error, please notify the sender and destroy the original transmission and its attachments without reading or saving.
5 Attachment 9 Page 5 of 29
McCoy, Mary
Subject: Location:
Fire Department Visit Coxsackie Welcome Conference Room
Start: End:
Wed 2/1/2023 6:30 PM Wed 2/1/2023 8:30 PM
Recurrence:
(none)
Meeting Status: Meeting organizer
Organizer:
McCoy, Mary
Required Attendees:Buccino, Charles; Shawn Burdick - Village of Coxsackie
Optional Attendees:Roque, Gregory
Resources:
Coxsackie Welcome Conference Room
Fire Department site visit.
Mary A. McCoy, PE EHS Manager
Ducommun AeroStructures New York, Inc. 171 Stacey Road Coxsackie, NY 12051-2613 203.300.7303 cell 518.731.4650 office
mmccoy@ducommun.com www.ducommun.com
1 Attachment 9 Page 6 of 29
McCoy, Mary
From: Sent: To: Subject:
McCoy, Mary Friday, October 27, 2023 1:13 PM Shawn Burdick - Village of Coxsackie RE: Contingency Plan
Hi Sawn,
Did you receive this message, which I sent yesterday? I wanted to check to make sure the files weren't too big.
M
Mary A. McCoy, PE 203.300.7303 cell
Safety Suggestions: EHSSupportNY@ducommun.com
From: McCoy, Mary Sent: Thursday, October 26, 2023 9:48 AM To: Shawn Burdick - Village of Coxsackie <firechief@villageofcoxsackie.com> Subject: Contingency Plan
Hi Shawn,
I've attached a RCRA Contingency Plan, which we are supposed to submit to you as per 40 CFR 262.262(a) and (b). These are two addresses that are listed in the plan. Are these the same organization?
Coxsackie Fire Department 119 Mansion Street Coxsackie, NY 12051
Coxsackie Hose Company #3 P.O. Box 303 Coxsackie, NY 12051
Mary A. McCoy, PE EHS Manager Ducommun AeroStructures New York, Inc. 171 Stacey Road Coxsackie, NY 12051-2613 203.300.7303 cell 518.731.4650 office mmccoy@ducommun.com www.ducommun.com
Safety Suggestions: EHSSupportNY@ducommun.com
1 Attachment 9 Page 7 of 29
McCoy, Mary
From: Sent: To: Subject:
Categories:
OEM, SERC (DHSES) <SERC.OEM@dhses.ny.gov> Thursday, October 26, 2023 11:39 AM McCoy, Mary RE: Ducommun AeroStructures NY: RCRA Contingency Plan
Saved to network drive
This email originated from outside Ducommun. Hover your mouse over any link to verify it. Do not click any links or open any attachments unless you trust the sender and know the content is safe.
Good morning Mary,
The New York State Emergency Response Commission (NYS SERC) is in receipt of your Hazardous Waste Contingency Plan for Ducommun AeroStructures NY, located in Coxsackie, NY. If you have any questions please let me know.
Thank you,
Cynthia Zobel OEM Planning NYS Division of Homeland Security & Emergency Services 1220 Washington Avenue, Bldg 22 Albany, NY 12242 518-292-2353 Landline cynthia.zobel@dhses.ny.gov
From: McCoy, Mary <MMcCoy@ducommun.com> Sent: Thursday, October 26, 2023 10:35 AM To: OEM, SERC (DHSES) <SERC.OEM@dhses.ny.gov> Subject: Ducommun AeroStructures NY: RCRA Contingency Plan
You don't often get email from mmccoy@ducommun.com. Learn why this is important
ATTENTION: This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails.
Greetings,
As a large quantity generator of RCRA hazardous waste, Ducommun AeroStructures Inc. of Coxsackie, New York, (DAS NY) is submitting the enclosed RCRA Contingency Plan and Quick Reference Guide to you as per Title 40 of the Code of Regulations 262.262(a) and (b).
Please acknowledge receipt.
1 Attachment 9 Page 8 of 29
If you have questions or comments, please contact me at (203) 300-7303 or mmccoy@ducommun.com. Mary A. McCoy, PE EHS Manager Ducommun AeroStructures New York, Inc. 171 Stacey Road Coxsackie, NY 12051-2613 203.300.7303 cell 518.731.4650 office mmccoy@ducommun.com www.ducommun.com
Safety Suggestions: EHSSupportNY@ducommun.com
From: NY.StateWatchCenter@dhses.ny.gov <NY.StateWatchCenter@dhses.ny.gov> Sent: Thursday, October 26, 2023 10:16 AM To: NY.StateWatchCenter@dhses.ny.gov Subject: RCRA Contingency Plan
This email originated from outside Ducommun. Hover your mouse over any link to verify it. Do not click any links or open any attachments unless you trust the sender and know the content is safe.
NYSWC receives, thank you
New York State Watch Center
Office of Emergency Management
Division of Homeland Security and Emergency Services 1220 Washington Ave, Building 22, Albany NY 12226 (518) 292-2200 | 5183224982@fax.ny.gov | NY.StateWatchCenter@dhses.ny.gov www.dhses.ny.gov
This message was sent to the following: MMcCoy@ducommun.com CONFIDENTIALITY NOTICE: This email transmission and any attachments to it may contain confidential information proprietary to Ducommun Incorporated and its subsidiaries or their customers. If you are not the intended recipient, a person responsible for delivering it to the intended recipient, or have received this transmission in error, please notify the sender and destroy the original transmission and its attachments without reading or saving.
2 Attachment 9 Page 9 of 29
McCoy, Mary
From: Sent: To: Subject:
O'Rourke, Danielle <orourkd@amc.edu> Friday, October 27, 2023 2:10 PM McCoy, Mary RE: RCRA Contingency Plan
This email originated from outside Ducommun. Hover your mouse over any link to verify it. Do not click any links or open any attachments unless you trust the sender and know the content is safe.
Yes, I did, I apologize for the delayed response . I have sent it to our clinical management team for review.
Danielle O'Rourke Occupational Medicine Coordinator Albany Med EmUrgentCare - Administration 1275 Broadway, MC-42, Menands, NY 12204 P:518-264-5598 F: 518-731-9119 orourkd@amc.edu Pronouns: She/Her/Hers Mon-Thurs 7:30-6
From: McCoy, Mary <MMcCoy@ducommun.com> Sent: Friday, October 27, 2023 1:16 PM To: Rogers, Alyssa <rogersa1@amc.edu>; O'Rourke, Danielle <orourkd@amc.edu> Subject: RE: RCRA Contingency Plan
Greetings, I was wondering if you received the email below yesterday. I want to make sure the attachment wasn't too big. M Mary A. McCoy, PE 203.300.7303 cell Safety Suggestions: EHSSupportNY@ducommun.com From: McCoy, Mary Sent: Thursday, ZjQcmQRYFpfptBannerStart
This Message Is From an External Sender
This message came from outside your organization.
Report Suspicious
ZjQcmQRYFpfptBannerEnd
Greetings,
I was wondering if you received the email below yesterday. I want to make sure the attachment wasn't too big.
M
Mary A. McCoy, PE 203.300.7303 cell
Safety Suggestions: EHSSupportNY@ducommun.com
1 Attachment 9 Page 10 of 29
From: McCoy, Mary Sent: Thursday, October 26, 2023 9:50 AM To: Rogers, Alyssa <rogersa1@amc.edu>; O'Rourke, Danielle <orourkd@amc.edu> Subject: RCRA Contingency Plan Greetings, I've attached a RCRA Contingency Plan, which we are supposed to submit to you as per 40 CFR 262.262(a) and (b). Would you please forward to the correct department and acknowledge receipt. Mary A. McCoy, PE EHS Manager Ducommun AeroStructures New York, Inc. 171 Stacey Road Coxsackie, NY 12051-2613 203.300.7303 cell 518.731.4650 office mmccoy@ducommun.com www.ducommun.com Safety Suggestions: EHSSupportNY@ducommun.com CONFIDENTIALITY NOTICE: This email transmission and any attachments to it may contain confidential information proprietary to Ducommun Incorporated and its subsidiaries or their customers. If you are not the intended recipient, a person responsible for delivering it to the intended recipient, or have received this transmission in error, please notify the sender and destroy the original transmission and its attachments without reading or saving. CONFIDENTIALITY NOTICE: This email and any attachments may contain confidential information that is protected by law and is for the sole use of the individuals or entities to which it is addressed. If you are not the intended recipient, please notify the sender by replying to this email and destroying all copies of the communication and attachments. Further use, disclosure, copying, distribution of, or reliance upon the contents of this email and attachments is strictly prohibited. To contact Albany Medical Center, Saratoga Hospital, Glens Falls Hospital or Columbia Memorial Hospital, or for a copy of our privacy practices, please visit us on the Internet at https://www.albanymed.org/.'
2 Attachment 9 Page 11 of 29
McCoy, Mary
From: Sent: To: Subject:
McCoy, Mary Tuesday, June 11, 2024 11:09 AM Zach Saccoccie RE: Site Walk Through
Hi Zach,
I'll go ahead and take this off the schedule for June 12 for planning purposes.
We are available any evening except the weeks of
June 24 through June 28 July 22 through July 26
M
Mary A. McCoy, PE 203.300.7303 cell
Safety Sugges ons: EHSSupportNY@ducommun.com
From: McCoy, Mary Sent: Monday, June 10, 2024 10:05 AM To: Zach Saccoccie <coxsackie3captain@gmail.com> Subject: RE: Site Walk Through
No worries.
M
Mary A. McCoy, PE 203.300.7303 cell
Safety Suggestions: EHSSupportNY@ducommun.com
From: Zach Saccoccie <coxsackie3captain@gmail.com> Sent: Monday, June 10, 2024 10:13 AM To: McCoy, Mary <MMcCoy@ducommun.com> Subject: Re: Site Walk Through
Mary the county just appointed a new haz-mat team chief. I have reached out to him in regards to joining us for the walk through. Once I hear back I will let you knoiw so we can set a date. sorry this is taking so long to get set up. Thanks ZjQcmQRYFpfptBannerStart
This Message Is From an External Sender
This message came from outside your organization.
ZjQcmQRYFpfptBannerEnd
Mary the county just appointed a new haz-mat team chief. I have reached out to him in regards to joining us for the walk through. Once I hear back I will let you knoiw so we can set a date. sorry this is taking so long to get set up. Thanks Capt Saccoccie
1 Attachment 9 Page 12 of 29
On Wed, May 22, 2024 at 6:54PM McCoy, Mary <MMcCoy@ducommun.com> wrote: Hi Zach,
No worries. Does June 12 at 6 pm work for you all?
M
Mary A. McCoy, PE 203.300.7303 cell
Safety Suggestions: EHSSupportNY@ducommun.com
From: Zach Saccoccie <coxsackie3captain@gmail.com> Sent: Wednesday, May 22, 2024 11:54 AM To: McCoy, Mary <MMcCoy@ducommun.com> Subject: Site Walk Through
Good Morning Mary, Sorry I'm just getting back to you. The month has been extremely busy. We would definitely like to schedule a visit with you guys. I see you'd like to have the Haz-Mat team there as well. Let me reach out to the team ZjQcmQRYFpfptBannerStart
This Message Is From an External Sender
This message came from outside your organization.
ZjQcmQRYFpfptBannerEnd
Good Morning Mary, Sorry I'm just getting back to you. The month has been extremely busy. We would definitely like to schedule a visit with you guys. I see you'd like to have the Haz-Mat team there as well. Let me reach out to the team and see if they are available. From there we can schedule a date if this works for you?
--
2 Attachment 9 Page 13 of 29
Coxsackie Hose Co#3 Saccoccie
(518)626-1250
Captain Zach Coxsackie3captain@gmail.com
CONFIDENTIALITY NOTICE: This email transmission and any attachments to it may contain confidential information proprietary to Ducommun Incorporated and its subsidiaries or their customers. If you are not the intended recipient, a person responsible for delivering it to the intended recipient, or have received this transmission in error, please notify the sender and destroy the original transmission and its attachments without reading or saving.
3 Attachment 9 Page 14 of 29
McCoy, Mary
From: Sent: To: Cc: Subject:
Categories:
Collette, Gregg <gregg.collette@veolia.com> Wednesday, December 13, 2023 2:07 PM McCoy, Mary Cathy McNamara; Rice, Renee; Zeh, Gary Re: Veolia Emergency Response Services
Saved to network drive
This email originated from outside Ducommun. Hover your mouse over any link to verify it. Do not click any links or open any attachments unless you trust the sender and know the content is safe.
Confirming receipt.
Gregg Collette -PM Veolia Gregg.collette@veolia.com 508-683/9823 cell phone
On Tue, Dec 12, 2023 at 9:57AM McCoy, Mary <MMcCoy@ducommun.com> wrote:
Hi Gregg,
I've attached a RCRA Contingency Plan, which we are required to submit to you as per 6 CRR-NY 373-3.3(g) AND 373.4. Would you kindly acknowledge receipt?
Let me know if you have questions or comments.
M
Mary A. McCoy, PE 203.300.7303 cell
Safety Suggestions: EHSSupportNY@ducommun.com
1 Attachment 9 Page 15 of 29
From: Zeh, Gary <gary.zeh@veolia.com> Sent: Tuesday, December 12, 2023 7:25 AM To: McCoy, Mary <MMcCoy@ducommun.com> Cc: Rice, Renee <renee.rice@veolia.com>; Barley, Linda <LBarley@ducommun.com>; Gregg Collette <gregg.collette@veolia.com>; Cathy McNamara <cathy.mcnamara@veolia.com> Subject: Re: Veolia Emergency Response Services
This email originated from outside Ducommun. Hover your mouse over any link to verify it. Do not click any links or open any attachments unless you trust the sender and know the content is safe.
Hi Mary,
I'm adding Gregg Collette who is our Industrial Project Manager and would be your contact for Emergency Services and questions.
Also adding Cathy McNamara who is our/your Account Manager and would be able to answer any questions about the Agreement or your Account.
Thanks.
On Mon, 11 Dec 2023 at 17:11, McCoy, Mary <MMcCoy@ducommun.com> wrote: Greetings,
Do you folks know who our contact is for emergency response services? I'd like to send them/you all a copy of our Contingency Plan.
Also, is there an expiration date on this agreement?
2 Attachment 9 Page 16 of 29
Mary A. McCoy, PE EHS Manager Ducommun AeroStructures New York, Inc. 171 Stacey Road Coxsackie, NY 12051-2613 203.300.7303 cell 518.731.4650 office mmccoy@ducommun.com www.ducommun.com
Safety Suggestions: EHSSupportNY@ducommun.com
CONFIDENTIALITY NOTICE: This email transmission and any attachments to it may contain confidential information proprietary to Ducommun Incorporated and its subsidiaries or their customers. If you are not the intended recipient, a person responsible for delivering it to the intended recipient, or have received this transmission in error, please notify the sender and destroy the original transmission and its attachments without reading or saving.
-- Gary Zeh
Operations Manager II - NY Industrial Business VEOLIA NORTH AMERICA
tel
+1 518.389.4498
3 Attachment 9 Page 17 of 29
cell +1 518.419.4796 (preferred) efax +1 518.704.6959 3 Northway Lane, Latham, NY 12110 gary.zeh@veolia.com www.veolianorthamerica.com
To help protect y our priv acy , Microsoft Office prev ented automatic download of this picture from the Internet.
CONFIDENTIALITY NOTICE: This email transmission and any attachments to it may contain confidential information proprietary to Ducommun Incorporated and its subsidiaries or their customers. If you are not the intended recipient, a person responsible for delivering it to the intended recipient, or have received this transmission in error, please notify the sender and destroy the original transmission and its attachments without reading or saving.
4 Attachment 9 Page 18 of 29
McCoy, Mary
From: Sent: To: Subject:
Categories:
Brianne Lee <blee@greenesheriffny.com> Tuesday, December 12, 2023 8:21 AM McCoy, Mary; Sheriff RE: Ducommun AeroStructures NY: RCRA Contingency Plan
Saved to network drive
This email originated from outside Ducommun. Hover your mouse over any link to verify it. Do not click any links or open any attachments unless you trust the sender and know the content is safe.
Hi Mary, We have received this. Thank you!
Brianne Lee Confidential Secretary to Sheriff Peter J. Kusminsky Greene County Sheriff's Office 45 Haverly Memorial Drive Coxsackie, N.Y. 12051 518-943-3300 x501 blee@greenesheriffny.com
From: McCoy, Mary <MMcCoy@ducommun.com> Sent: Monday, December 11, 2023 4:38 PM To: Sheriff <sheriff@greenesheriffny.com> Subject: Ducommun AeroStructures NY: RCRA Contingency Plan
Greetings,
I've attached a RCRA Contingency Plan, which we are required to submit to you as per 6 CRR-NY 373-3.3(g) AND 373.4. Would you please acknowledge receipt?
Let me know if you have questions or comments.
Mary A. McCoy, PE EHS Manager Ducommun AeroStructures New York, Inc. 171 Stacey Road Coxsackie, NY 12051-2613
1 Attachment 9 Page 19 of 29
203.300.7303 cell 518.731.4650 office mmccoy@ducommun.com www.ducommun.com Safety Suggestions: EHSSupportNY@ducommun.com CONFIDENTIALITY NOTICE: This email transmission and any attachments to it may contain confidential information proprietary to Ducommun Incorporated and its subsidiaries or their customers. If you are not the intended recipient, a person responsible for delivering it to the intended recipient, or have received this transmission in error, please notify the sender and destroy the original transmission and its attachments without reading or saving.
2 Attachment 9 Page 20 of 29
SENDER: COMPLETE THIS SECTION
Complete items 1, 2, and 3. Print your name and address on the reverse
so that we can return the card to you.
Attach this card to the back of the mailpiece,
or on the front if space permits. 1. Article Addressed to:
St. Peter's Hospital 315 South Manning Blvd. Albany, NY 12208
COMPLETE THIS SECTION ON DELIVERY
A. Signature' ,
X 12Jdzd!
B. Received by (Printed Name)
O Agent O Addressee C. Date of Delivery
D. Is delivery address different from item 1? O Yes If YES, enter delivery address below: O No
li 3. Service Type
li lllllll llll lllllll I 11111111111111111111111
O Adult Signature
,Adult Signature Restricted Delivery
6Z Certified Mail
9590 9402 8026 2305 5976 52
O Certified Mail Restricted Delivery
O Collect on Delivery
-.,--..-,;,...,.-, N:-,-,m-h-.-,,""r"r=,-,-,.n-.s-f,-.-, -,m-m-.s,-.r-v,-.,,,-._ -,a-be_/_) -----l O Collect on Delivery Restricted Delivery
O Priority Mail EY"ress O Registered Mail'
O Reiistered Mail Resa . Delivery
O Signature ConfirmationTM O Signature Confirmation
Restricted Delivery
7 0 15 15 2 0 0 0 0 0 7119 2 3 6 6
:~:~:: ~~: Restricted Delivery
(over$500
PS Form 3811, July 2020 PSN 7530-02-000-9053
Domestic Return Receipt
i
Attachment 9 Page 21 of 29
1111111iiiU~ L \ \\ \\ \
First-Class Mail Postage & Fees Paid
USPS Permit No. G-10
9590 9402 8026 2305 5976 52
United States Postal Service
Sender: Please print your name, address, and ZIP+4 in this box
Ducommun
_ 171 Stacey Road
Co,sackle, NY 1 O 'i@mR\VJffl ~
Attachment 9 Page 22 of 29
_; i-25 i 37 i
-
2/21/24, 11:42 AM
USPS.com - USPS Tracking Results
ALERT: SEVERE WEATHER CONDITIONS ACROSS THE U.S. MAY DELAY FINAL DELIVERY OF Y...
USPS Tracking
FAQs
Tracking Number:
70151520000071192366
Copy
Add to Informed Delivery (https://informeddelivery.usps.com/)
Remove
Latest Update
Your item was picked up at a postal facility at 9:17 am on October 31, 2023 in ALBANY, NY 12206.
Get More Out of USPS Tracking: USPS Tracking Plus
Delivered
Delivered, Individual Picked Up at Postal Facility ALBANY, NY 12206 October 31, 2023, 9:17 am
See All Tracking History
What Do USPS Tracking Statuses Mean? (https://faq.usps.com/s/article/Where-is-my-package)
Feedback
Text & Email Updates
USPS Tracking Plus
Product Information
See Less
Tracking Number:
Remove
70151520000071192397Attachment 9 Page 23 of 29
https://tools.usps.com/go/TrackConfirmAction?tRef=fullpage&tLc=6&text28777=&tLabels=70151520000071192366%2C70151520000071192397%2C... 1/4
2/21/24, 11:42 AM
Copy
USPS.com - USPS Tracking Results
Add to Informed Delivery (https://informeddelivery.usps.com/)
Latest Update
Your item was delivered to an individual at the address at 10:45 am on November 6, 2023 in CAIRO, NY 12413.
Get More Out of USPS Tracking: USPS Tracking Plus
Delivered
Delivered, Left with Individual CAIRO, NY 12413 November 6, 2023, 10:45 am
See All Tracking History
What Do USPS Tracking Statuses Mean? (https://faq.usps.com/s/article/Where-is-my-package)
See More
Tracking Number:
70151520000071192380
Copy
Add to Informed Delivery (https://informeddelivery.usps.com/)
Remove
Latest Update
Your item was picked up at the post office at 9:13 am on October 31, 2023 in HUDSON, NY 12534.
Get More Out of USPS Tracking: USPS Tracking Plus
Delivered
Delivered, Individual Picked Up at Post Office HUDSON, NY 12534 October 31, 2023, 9:13 am
See All Tracking History
What Do USPS Tracking Statuses Mean? (https://faq.usps.com/s/article/Where-is-my-package)
See More
Attachment 9 Page 24 of 29 https://tools.usps.com/go/TrackConfirmAction?tRef=fullpage&tLc=6&text28777=&tLabels=70151520000071192366%2C70151520000071192397%2C... 2/4
2/21/24, 11:42 AM
USPS.com - USPS Tracking Results
Tracking Number:
70151520000071192373
Copy
Add to Informed Delivery (https://informeddelivery.usps.com/)
Remove
Latest Update
Your item was picked up at the post office at 3:47 pm on November 6, 2023 in EARLTON, NY 12058.
Get More Out of USPS Tracking: USPS Tracking Plus
Delivered
Delivered, Individual Picked Up at Post Office EARLTON, NY 12058 November 6, 2023, 3:47 pm
See All Tracking History
What Do USPS Tracking Statuses Mean? (https://faq.usps.com/s/article/Where-is-my-package)
See More
Tracking Number:
70151520000071192359
Copy
Add to Informed Delivery (https://informeddelivery.usps.com/)
Remove
Latest Update
Your item was delivered to an individual at the address at 11:48 am on November 1, 2023 in SOUTH CAIRO, NY 12482.
Get More Out of USPS Tracking: USPS Tracking Plus
Attachment 9 Page 25 of 29 https://tools.usps.com/go/TrackConfirmAction?tRef=fullpage&tLc=6&text28777=&tLabels=70151520000071192366%2C70151520000071192397%2C... 3/4
2/21/24, 11:42 AM
Delivered
Delivered, Left with Individual SOUTH CAIRO, NY 12482 November 1, 2023, 11:48 am
USPS.com - USPS Tracking Results
See All Tracking History
What Do USPS Tracking Statuses Mean? (https://faq.usps.com/s/article/Where-is-my-package)
Text & Email Updates
USPS Tracking Plus
Product Information
Track Another Package
Enter tracking or barcode numbers
See Less
Need More Help?
Contact USPS Tracking support for further assistance.
FAQs
Attachment 9 Page 26 of 29 https://tools.usps.com/go/TrackConfirmAction?tRef=fullpage&tLc=6&text28777=&tLabels=70151520000071192366%2C70151520000071192397%2C... 4/4
McCoy, Mary
From: Sent: To: Subject:
Categories:
Sam Mento - Village of Coxsackie PD <smento@villageofcoxsackiepolice.com> Monday, December 11, 2023 6:55 PM McCoy, Mary Re: RCRA Contingency Plan
Saved to network drive
This email originated from outside Ducommun. Hover your mouse over any link to verify it. Do not click any links or open any attachments unless you trust the sender and know the content is safe.
Good Evening Mary,
Thank you for reaching out, yes I did receive the file.
Thank you,
Chief Samuel Mento Coxsackie Police Department 119 Mansion Street, Coxsackie N.Y. 12051 PD (518) 731-8122, Fax (518) 731-2508 Cell (518) 915-5677
From: McCoy, Mary <MMcCoy@ducommun.com> Sent: Monday, December 11, 2023 4:34 PM To: Sam Mento - Village of Coxsackie PD <smento@villageofcoxsackiepolice.com> Subject: RE: RCRA Contingency Plan
This email comes from outside the organization.
Do not click links or open attachments unless it is an email you expected to receive.
Hello Chief,
I sent a RCRA Contingency Plan back in October. I wasn't sure if you received it - it was a rather large file.
1 Attachment 9 Page 27 of 29
Did you receive it?
M
Mary A. McCoy, PE 203.300.7303 cell
Safety Suggestions: EHSSupportNY@ducommun.com
From: McCoy, Mary Sent: Friday, October 27, 2023 3:23 PM To: Sam Mento - Village of Coxsackie PD <smento@villageofcoxsackiepolice.com> Subject: RCRA Contingency Plan
Hi Chief Mento,
I've attached a RCRA Contingency Plan, which we are supposed to submit to you as per 40 CFR 262.262(a) and (b).
If you have any questions or comments, please contact me.
Would you kindly acknowledge receipt?
M
Mary A. McCoy, PE 203.300.7303 cell
Safety Suggestions: EHSSupportNY@ducommun.com
From: Sam Mento - Village of Coxsackie PD <smento@villageofcoxsackiepolice.com> Sent: Thursday, April 20, 2023 1:51 PM To: McCoy, Mary <MMcCoy@ducommun.com> Subject: Contingency Plan
This email originated from outside Ducommun. Hover your mouse over any link to verify it. Do not click any links or open any attachments unless you trust the sender and know the content is safe.
Good Afternoon, Mary
I received a message from Chief Burdick regarding a contingency plan for your company. The village of Coxsackie Police Department is the responding agency for the village of Coxsackie. If you require any further feel free to respond to this email.
Thank you,
Chief Samuel Mento Coxsackie Police Department
2 Attachment 9 Page 28 of 29
119 Mansion Street, Coxsackie N.Y. 12051 PD (518) 731-8122, Fax (518) 731-2508 Cell (518) 915-5677
CONFIDENTIALITY NOTICE: This email transmission and any attachments to it may contain confidential information proprietary to Ducommun Incorporated and its subsidiaries or their customers. If you are not the intended recipient, a person responsible for delivering it to the intended recipient, or have received this transmission in error, please notify the sender and destroy the original transmission and its attachments without reading or saving.
3 Attachment 9 Page 29 of 29
Attachment 10 Adhesives Sealant Waste Determination
Form No.: Last Reviewed Date: Revision No.: Coxsackie, New York
F-00663 Hazardous Waste Determination Worksheet -
10/17/2023 A
Authorized By: WI-00216 Environmental Management System - Requirements
Page 1 of 2
DCO Site:
Coxsackie 171 Stacey Road Coxsackie, NY 12051-2613
EPA ID:
NYR 000 219 550
Date:
6/17/2024
By:
Mary McCoy
Waste Stream Common Name:
Adheaseive/sealant debris
Check one: RCRA Haz Waste
Non-RCRA Haz Waste
Not Haz Waste
RCRA Waste Codes:
NA
State Waste Codes:
NA
0
Source Code: NA
0
Form Code: NA
0
Management Method:
#N/A
(For California sites, if this waste is subject to 22 CCR 66266.1 and is not recycled, attach justification.)
UN#, Proper Shipping Name, Hazard Class, Packing Group: NA
ERG:
NA
Check one: Ongoing
RQ Threshold:
NA
Intermittent
One-time
Other information: Previous analytical results indicate non-hazardous
Waste generation process (listed, characteristic); chemicals used; location within facility:
Adhesive and sealant mixing and usage generating cups, wooden mixers, rags, syringes laden with dried adhesives and sealants.
Attachment 10 Page 1 of 17
#=CL#
LIMS USE: FR - MARY MCCOY LIMS OBJECT ID: 70299090
June 12, 2024
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Mary McCoy Ducommun Aerostructures 171 Stacy Road Coxsackie, NY 12051
RE: Project: SEALANTS/ADHESIVE DEBRIS 5/24 Pace Project No.: 70299090
Dear Mary McCoy: Enclosed are the analytical results for sample(s) received by the laboratory on May 24, 2024. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report.
The test results provided in this final report were generated by each of the following laboratories within the Pace Network: Pace Analytical Services - Melville
If you have any questions concerning this report, please feel free to contact me.
Sincerely,
Daniel H. Bonitto daniel.bonitto@pacelabs.com 516-370-6000 Project Manager
Enclosures
cc: Linda Barley, Ducommun Aerostructures Pedro Dumaua, Ducommun Aerostructures Eugenia Lighthouse, Ducommun Incorporated
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the wriAttettnaccohnmseenntto1f0PaPcaegAena2lyotifc1al7Services, LLC.
Page 1 of 16
#=CP#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Project: Pace Project No.:
SEALANTS/ADHESIVE DEBRIS 5/24 70299090
Pace Analytical Services Long Island 575 Broad Hollow Rd, Melville, NY 11747 Connecticut Certification #: PH-0435 Delaware Certification # NY 10478 Maryland Certification #: 208 Massachusetts Certification #: M-NY026 New Hampshire Certification #: 2987
CERTIFICATIONS
New Jersey Certification #: NY158 New York Certification #: 10478 Primary Accrediting Body Pennsylvania Certification #: 68-00350 Rhode Island Certification #: LAO00340 Virginia Certification # 460302
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the wriAttettnaccohnmseenntto1f0PaPcaegAena3lyotifc1al7Services, LLC.
Page 2 of 16
#=SA#
SAMPLE ANALYTE COUNT
Project: Pace Project No.:
SEALANTS/ADHESIVE DEBRIS 5/24 70299090
Lab ID 70299090001
Sample ID 24052301-MAM
PACE-MV = Pace Analytical Services - Melville
Method
EPA 6010D EPA 7470A EPA 8260C ASTM D2216-05M
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
Analysts
JWT JP2 BBL NAA
Analytes Reported
Laboratory
7 PACE-MV 1 PACE-MV 13 PACE-MV 1 PACE-MV
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the wriAttettnaccohnmseenntto1f0PaPcaegAena4lyotifc1al7Services, LLC.
Page 3 of 16
#=AR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
ANALYTICAL RESULTS
Project: Pace Project No.:
SEALANTS/ADHESIVE DEBRIS 5/24 70299090
Sample: 24052301-MAM
Lab ID: 70299090001 Collected: 05/23/24 07:00 Received: 05/24/24 08:00 Matrix: Solid
Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions.
Parameters
Results
Units
Report Limit DF
Prepared
Analyzed
CAS No.
Qual
6010D MET ICP, TCLP
Arsenic Barium Cadmium Chromium Lead Selenium Silver
7470 Mercury, TCLP
Mercury
8260C MSV TCLP
1,1-Dichloroethene 1,2-Dichloroethane 2-Butanone (MEK) Benzene Carbon tetrachloride Chlorobenzene Chloroform Tetrachloroethene Trichloroethene Vinyl chloride Surrogates 1,2-Dichloroethane-d4 (S) Toluene-d8 (S) 4-Bromofluorobenzene (S)
Percent Moisture
Percent Moisture
Analytical Method: EPA 6010D Preparation Method: EPA 3005A Leachate Method/Date: EPA 1311; 05/28/24 23:28 Pace Analytical Services - Melville
<0.050 <1.0
0.014 3.9
0.21 <0.050 <0.050
mg/L mg/L mg/L mg/L mg/L mg/L mg/L
0.050 1 05/30/24 07:07 05/30/24 12:17 7440-38-2 1.0 1 05/30/24 07:07 05/30/24 12:17 7440-39-3
0.012 1 05/30/24 07:07 05/30/24 12:17 7440-43-9 0.050 1 05/30/24 07:07 05/30/24 12:17 7440-47-3 0.025 1 05/30/24 07:07 05/30/24 12:17 7439-92-1 0.050 1 05/30/24 07:07 05/30/24 12:17 7782-49-2 0.050 1 05/30/24 07:07 05/30/24 12:17 7440-22-4
Analytical Method: EPA 7470A Preparation Method: EPA 7470A Leachate Method/Date: EPA 1311; 05/28/24 23:28 Pace Analytical Services - Melville
<0.00020
mg/L
0.00020 1 06/03/24 08:00 06/03/24 14:36 7439-97-6
Analytical Method: EPA 8260C Leachate Method/Date: EPA 1311; 05/29/24 23:40 Pace Analytical Services - Melville
<0.010 <0.010
0.20 <0.010 <0.010 <0.010 <0.010 <0.010 <0.010 <0.010
mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L
0.010 5 0.010 5 0.025 5 0.010 5 0.010 5 0.010 5 0.010 5 0.010 5 0.010 5 0.010 5
05/31/24 20:11 75-35-4 05/31/24 20:11 107-06-2 05/31/24 20:11 78-93-3 05/31/24 20:11 71-43-2 05/31/24 20:11 56-23-5 05/31/24 20:11 108-90-7 M1 05/31/24 20:11 67-66-3 05/31/24 20:11 127-18-4 M1 05/31/24 20:11 79-01-6 05/31/24 20:11 75-01-4
92
%
100
%
105
%
80-120 5 75-122 5 73-122 5
Analytical Method: ASTM D2216-05M Pace Analytical Services - Melville
2.8
%
0.10 1
05/31/24 20:11 17060-07-0 05/31/24 20:11 2037-26-5 05/31/24 20:11 460-00-4
05/28/24 06:25
Date: 06/12/2024 04:03 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the wriAttettnaccohnmseenntto1f0PaPcaegAena5lyotifc1al7Services, LLC.
Page 4 of 16
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
SEALANTS/ADHESIVE DEBRIS 5/24 70299090
QC Batch: QC Batch Method:
350108 EPA 7470A
Associated Lab Samples: 70299090001
METHOD BLANK: 1811176 Associated Lab Samples: 70299090001
Mercury
Parameter
Units mg/L
Analysis Method: Analysis Description: Laboratory:
EPA 7470A 7470 Mercury TCLP Pace Analytical Services - Melville
Matrix: Water
Blank Result
<0.00020
Reporting Limit
0.00020
Analyzed 06/03/24 14:23
Qualifiers
METHOD BLANK: 1810954 Associated Lab Samples: 70299090001
Mercury
Parameter
Units mg/L
Matrix: Water
Blank Result
<0.00020
Reporting Limit
0.00020
Analyzed 06/03/24 14:35
Qualifiers
LABORATORY CONTROL SAMPLE: 1811177
Mercury
Parameter
Units mg/L
Spike Conc.
0.001
LCS Result
0.0010
LCS % Rec
100
% Rec Limits
80-120
Qualifiers
MATRIX SPIKE SAMPLE:
Mercury
Parameter
1811178
Units mg/L
70298087004 Result
<0.00020
Spike Conc.
0.001
MS Result
0.0011
MS % Rec
105
% Rec Limits
75-125
Qualifiers
SAMPLE DUPLICATE: 1811179
Mercury
Parameter
Units mg/L
70298087004 Result
<0.00020
Dup Result
<0.00020
RPD
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 06/12/2024 04:03 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the wriAttettnaccohnmseenntto1f0PaPcaegAena6lyotifc1al7Services, LLC.
Page 5 of 16
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
SEALANTS/ADHESIVE DEBRIS 5/24 70299090
QC Batch: QC Batch Method:
349768 EPA 3005A
Associated Lab Samples: 70299090001
METHOD BLANK: 1809333 Associated Lab Samples: 70299090001
Arsenic Barium Cadmium Chromium Lead Selenium Silver
Parameter
Units
mg/L mg/L mg/L mg/L mg/L mg/L mg/L
Analysis Method: Analysis Description: Laboratory:
EPA 6010D 6010D MET TCLP Pace Analytical Services - Melville
Matrix: Water
Blank Result
<0.010 <0.20
<0.0025 <0.010
<0.0050 <0.010 <0.010
Reporting Limit
0.010 0.20
0.0025 0.010
0.0050 0.010 0.010
Analyzed
05/30/24 11:49 05/30/24 11:49 05/30/24 11:49 05/30/24 11:49 05/30/24 11:49 05/30/24 11:49 05/30/24 11:49
Qualifiers
LABORATORY CONTROL SAMPLE: 1809334
Arsenic Barium Cadmium Chromium Lead Selenium Silver
Parameter
Units
mg/L mg/L mg/L mg/L mg/L mg/L mg/L
Spike Conc.
0.5 0.5 0.5 0.5 0.5 0.5 0.25
LCS Result
0.48 0.50 0.50 0.49 0.50 0.47 0.24
LCS % Rec
95 100
99 99 100 94 98
% Rec Limits
80-120 80-120 80-120 80-120 80-120 80-120 80-120
Qualifiers
MATRIX SPIKE SAMPLE:
Arsenic Barium Cadmium Chromium Lead Selenium Silver
Parameter
1809336
Units
mg/L mg/L mg/L mg/L mg/L mg/L mg/L
70299194001 Result
<0.050 <1.0
<0.012 <0.050 <0.025 <0.050 <0.050
Spike Conc.
0.5 0.5 0.5 0.5 0.5 0.5 0.25
MS Result
0.48 <1.0 0.47 0.47 0.49 0.46 0.26
MS % Rec
91 95 94 93 95 84 102
% Rec Limits
75-125 75-125 75-125 75-125 75-125 75-125 75-125
Qualifiers
SAMPLE DUPLICATE: 1809335
Arsenic Barium Cadmium
Parameter
Units
mg/L mg/L mg/L
70299194001 Result
<0.050 <1.0
<0.012
Dup Result
<0.050 <1.0
<0.012
RPD
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 06/12/2024 04:03 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the wriAttettnaccohnmseenntto1f0PaPcaegAena7lyotifc1al7Services, LLC.
Page 6 of 16
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
SEALANTS/ADHESIVE DEBRIS 5/24 70299090
SAMPLE DUPLICATE: 1809335
Chromium Lead Selenium Silver
Parameter
Units
mg/L mg/L mg/L mg/L
70299194001 Result
<0.050 <0.025 <0.050 <0.050
Dup Result
<0.050 <0.025 <0.050 <0.050
RPD
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 06/12/2024 04:03 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the wriAttettnaccohnmseenntto1f0PaPcaegAena8lyotifc1al7Services, LLC.
Page 7 of 16
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
SEALANTS/ADHESIVE DEBRIS 5/24 70299090
QC Batch: QC Batch Method:
350048 EPA 8260C
Associated Lab Samples: 70299090001
METHOD BLANK: 1810642 Associated Lab Samples: 70299090001
Parameter
1,1-Dichloroethene 1,2-Dichloroethane 2-Butanone (MEK) Benzene Carbon tetrachloride Chlorobenzene Chloroform Tetrachloroethene Trichloroethene Vinyl chloride 1,2-Dichloroethane-d4 (S) 4-Bromofluorobenzene (S) Toluene-d8 (S)
Units
mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L
% % %
Analysis Method: Analysis Description: Laboratory:
EPA 8260C 8260 MSV TCLP Pace Analytical Services - Melville
Matrix: Water
Blank Result
<0.0020 <0.0020 <0.0050 <0.0020 <0.0020 <0.0020 <0.0020 <0.0020 <0.0020 <0.0020
92 106
98
Reporting Limit
0.0020 0.0020 0.0050 0.0020 0.0020 0.0020 0.0020 0.0020 0.0020 0.0020 80-120 73-122 75-122
Analyzed
05/31/24 15:20 05/31/24 15:20 05/31/24 15:20 05/31/24 15:20 05/31/24 15:20 05/31/24 15:20 05/31/24 15:20 05/31/24 15:20 05/31/24 15:20 05/31/24 15:20 05/31/24 15:20 05/31/24 15:20 05/31/24 15:20
Qualifiers
METHOD BLANK: 1806683 Associated Lab Samples: 70299090001
Parameter
1,1-Dichloroethene 1,2-Dichloroethane 2-Butanone (MEK) Benzene Carbon tetrachloride Chlorobenzene Chloroform Tetrachloroethene Trichloroethene Vinyl chloride 1,2-Dichloroethane-d4 (S) 4-Bromofluorobenzene (S) Toluene-d8 (S)
Units
mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L
% % %
Matrix: Solid
Blank Result
<0.010 <0.010 <0.025 <0.010 <0.010 <0.010 <0.010 <0.010 <0.010 <0.010
93 105
97
Reporting Limit
0.010 0.010 0.025 0.010 0.010 0.010 0.010 0.010 0.010 0.010 80-120 73-122 75-122
Analyzed
05/31/24 19:31 05/31/24 19:31 05/31/24 19:31 05/31/24 19:31 05/31/24 19:31 05/31/24 19:31 05/31/24 19:31 05/31/24 19:31 05/31/24 19:31 05/31/24 19:31 05/31/24 19:31 05/31/24 19:31 05/31/24 19:31
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 06/12/2024 04:03 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the wriAttettnaccohnmseenntto1f0PaPcaegAena9lyotifc1al7Services, LLC.
Page 8 of 16
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
SEALANTS/ADHESIVE DEBRIS 5/24 70299090
METHOD BLANK: 1809269 Associated Lab Samples: 70299090001
Parameter
1,1-Dichloroethene 1,2-Dichloroethane 2-Butanone (MEK) Benzene Carbon tetrachloride Chlorobenzene Chloroform Tetrachloroethene Trichloroethene Vinyl chloride 1,2-Dichloroethane-d4 (S) 4-Bromofluorobenzene (S) Toluene-d8 (S)
Units
mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L
% % %
Matrix: Solid
Blank Result
<0.010 <0.010 <0.025 <0.010 <0.010 <0.010 <0.010 <0.010 <0.010 <0.010
90 104
95
Reporting Limit
0.010 0.010 0.025 0.010 0.010 0.010 0.010 0.010 0.010 0.010 80-120 73-122 75-122
Analyzed
05/31/24 19:51 05/31/24 19:51 05/31/24 19:51 05/31/24 19:51 05/31/24 19:51 05/31/24 19:51 05/31/24 19:51 05/31/24 19:51 05/31/24 19:51 05/31/24 19:51 05/31/24 19:51 05/31/24 19:51 05/31/24 19:51
Qualifiers
LABORATORY CONTROL SAMPLE: 1810643
Parameter
1,1-Dichloroethene 1,2-Dichloroethane 2-Butanone (MEK) Benzene Carbon tetrachloride Chlorobenzene Chloroform Tetrachloroethene Trichloroethene Vinyl chloride 1,2-Dichloroethane-d4 (S) 4-Bromofluorobenzene (S) Toluene-d8 (S)
Units
mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L
% % %
Spike Conc.
0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05
LCS Result
0.043 0.046 0.046 0.049 0.051 0.052 0.047 0.056 0.051 0.039
LCS % Rec
86 93 92 98 102 104 94 112 101 78 94 108 98
% Rec Limits
Qualifiers
66-133 69-134 33-165 78-117 64-135 79-117 79-123 65-120 v1 79-115 49-118 80-120 73-122 75-122
MATRIX SPIKE SAMPLE:
Parameter
1,1-Dichloroethene 1,2-Dichloroethane 2-Butanone (MEK) Benzene Carbon tetrachloride Chlorobenzene Chloroform Tetrachloroethene
1811272
Units
mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L
70299090001 Result
<0.010 <0.010
0.20 <0.010 <0.010 <0.010 <0.010 <0.010
Spike Conc.
0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
MS Result
0.30 0.27 0.42 0.28 0.33 0.32 0.29 0.37
MS % Rec
120 107
88 114 131 128 117 147
% Rec Limits
Qualifiers
61-139 58-138 33-148 70-130 56-143 74-122 71-129 64-124
M1 M1, v1
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 06/12/2024 04:03 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the wrAitttetancchomnseenntt 1of0PPaacegeAn1a0lytoicfa1l 7Services, LLC.
Page 9 of 16
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
SEALANTS/ADHESIVE DEBRIS 5/24 70299090
MATRIX SPIKE SAMPLE:
Parameter
Trichloroethene Vinyl chloride 1,2-Dichloroethane-d4 (S) 4-Bromofluorobenzene (S) Toluene-d8 (S)
1811272
Units
mg/L mg/L
% % %
70299090001 Result
<0.010 <0.010
Spike Conc.
0.25 0.25
MS Result
0.30 0.26
MS % Rec
122 103
92 108 100
% Rec Limits
73-125 33-127 80-120 73-122 75-122
Qualifiers
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 06/12/2024 04:03 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the wrAitttetancchomnseenntt 1of0PPaacegeAn1a1lytoicfa1l 7Services, LLC.
Page 10 of 16
#=QC#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA
Project: Pace Project No.:
SEALANTS/ADHESIVE DEBRIS 5/24 70299090
QC Batch: QC Batch Method:
349510 ASTM D2216-05M
Associated Lab Samples: 70299090001
Analysis Method: Analysis Description: Laboratory:
ASTM D2216-05M Dry Weight/Percent Moisture Pace Analytical Services - Melville
SAMPLE DUPLICATE: 1807706
Parameter Percent Moisture
Units %
70298976003 Result
65.8
Dup Result
66.6
RPD
Qualifiers
1
SAMPLE DUPLICATE: 1807707
Parameter Percent Moisture
Units %
70299165001 Result
17.8
Dup Result
16.2
RPD
Qualifiers
9
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
Date: 06/12/2024 04:03 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the wrAitttetancchomnseenntt 1of0PPaacegeAn1a2lytoicfa1l 7Services, LLC.
Page 11 of 16
#=QL#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALIFIERS
Project: Pace Project No.:
SEALANTS/ADHESIVE DEBRIS 5/24 70299090
DEFINITIONS
DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot.
ND - Not Detected at or above adjusted reporting limit.
TNTC - Too Numerous To Count
J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit.
MDL - Adjusted Method Detection Limit.
PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values.
LCS(D) - Laboratory Control Sample (Duplicate)
MS(D) - Matrix Spike (Duplicate)
DUP - Sample Duplicate
RPD - Relative Percent Difference
NC - Not Calculable.
SG - Silica Gel - Clean-Up
U - Indicates the compound was analyzed for, but not detected. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes.
TNI - The NELAC Institute.
BATCH QUALIFIERS
Batch: 349775
[1]
The post digestion spike for sample 70299194001 (PDS 1809350) did not meet acceptance criteira for Silver, Arsenic,
Barium, Cadmium, Chromium, Lead, and Selenium.
[2]
The serial dilution for sample 70299194001 (SD 1809351) did not meet acceptance criteira for Arsenic, Barium and
Selenium.
ANALYTE QUALIFIERS
M1
Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.
v1
The continuing calibration verification was above the method acceptance limit. Any detection for the analyte in the
associated samples may have a high bias.
Date: 06/12/2024 04:03 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the wrAitttetancchomnseenntt 1of0PPaacegeAn1a3lytoicfa1l 7Services, LLC.
Page 12 of 16
#=CR#
Pace Analytical Services, LLC 575 Broad Hollow Road Melville, NY 11747 516-370-6000
QUALITY CONTROL DATA CROSS REFERENCE TABLE
Project: Pace Project No.:
SEALANTS/ADHESIVE DEBRIS 5/24 70299090
Lab ID 70299090001 70299090001 70299090001 70299090001
Sample ID 24052301-MAM 24052301-MAM 24052301-MAM 24052301-MAM
QC Batch Method EPA 3005A EPA 7470A EPA 8260C ASTM D2216-05M
QC Batch 349768 350108 350048 349510
Analytical Method EPA 6010D EPA 7470A
Analytical Batch
349775 350149
Date: 06/12/2024 04:03 PM
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the wrAitttetancchomnseenntt 1of0PPaacegeAn1a4lytoicfa1l 7Services, LLC.
Page 13 of 16
Attachment 10 Page 15 of 17
Page 14 of 16
Attachment 10 Page 16 of 17
Page 15 of 16
Attachment 10 Page 17 of 17
Page 16 of 16
Attachment 11 Waste Manifest Examples
Attachment 11 Page 1 of 7
Attachment 11 Page 2 of 7
Attachment 11 Page 3 of 7
Attachment 11 Page 4 of 7
Attachment 11 Page 5 of 7
Attachment 11 Page 6 of 7
Attachment 11 Page 7 of 7