Document YroQrxb4dRLvR8aOLxXMZrdq8

EPA Inspection Report - Page 1 of 3 Region 6 Compliance Assurance and Enforcement Division INSPECTION REPORT Inspection Date(s): Media: Regulatory Program(s) 08/01-02/2017 Water Clean Water Act/ NPDES Company Name: Facility Name: Facility Physical Location: (city, state, zip code) Mailing address: (city, state, zip code) County/Parish: Facility Contact: Vallourec Star, LP Vallourec Star Houston 8603 Sheldon Road Houston, Texas 77049-1812 8603 Sheldon Road Houston, Texas 77049-1812 Harries County Karl Crouch Karl.crouch@vallourec.com I Plant Manager FRS Number: Identification/Permit Number: Media Number: NAICS: SIC: 110000462179 TX0088455 3498 Personnel participating in inspection: Kenneth L AuBuchon USEPA/6EN-WMH Karl Crouch Vallourec Star- Houston lan Grayson Vaflourec Star- Houston Kristin Malosh Vallourec Star Dick Pursley HDR Levie Spidle HDR Environmental Engineer Plant Manager EHS Coordinator N.A. EHS Director Commissioning Manager Operator EPA Lead Inspector Signature/Date Supervisor Signature/Date Kermeth L Aul)w;hol1 Kenneth L AuBuchon (__~ (J<--J-!)y- Carol Peters 281-983-21S1 281-456-6087 281-456-6096 330-742-1915 713-576-3547 832-675-2318 11/29/2017 Date n-/r' /7 Date 6ENFORM-019-R7 (2/15/2017) 1 EPA Inspection Report - Page 2 of 3 Section I - INTRODUCTION PURPOSE OF THE INSPECTION EPA Region 6 inspector Kenneth L. AuBuchon arrived at Vallourec Star, LP - Houston at approximately 9:30 am on August 01, 2017 for an unannounced Compliance Evaluation Inspection (CEI). I met with Ian Grayson, Vallourec Star, LP - Houston EHS Coordinator and Karl Crouch, Vallourec Star, LP - Houston Plant Manager, at the Opening Conference. I presented my credentials to both Mr. Grayson and Mr. Crouch and explained that this was an EPA inspection to determine compliance with the facility's National Pollutant Discharge Elimination System (NPDES) permit and Clean Water Act (CWA). The inspection was conducted under the authority of the NPDES permit program, in accordance with the Federal CWA. This report is based on information supplied by Vallourec Star, LP - Houston representatives (the permittee), observations made by the U.S. EPA inspector, and records and reports maintained by the permittee, the State of Texas, and the U.S. EPA. FACILITY DESCRIPTION The Vallourec Star, LP - Houston facility is located in the southern region of East Texas at 8603 Sheldon Road, approximately 1.5 miles south of U.S. Highway 90 and approximately 0.75 miles north of Miller Rd. No. 1 in Houston, Harries County, near Channelview, Texas. The Vallourec Star, LP - Houston facility heat-treats and end finishes alloy "green" tubes into alloy Oil Country Tubular Goods (OCTG). "Green" tubes are manufactured at the company's Youngstown, Ohio pipe mill, and shipped via rail to the Houston facility. After arriving at the Houston facility, the pipe is heated to 1,600 degrees Fahrenheit and rapidly cooled by water quenching, and charged into an indirect gas-fired tempering furnace. The pipe is also cut, threaded, and coated with a corrosion inhibitor and stenciled, as appropriate. Section II - OBSERVATIONS The current Vallourec Star, LP TPDES Permit (TX0088455), as issued on August 11, 2014, permits the discharge of wastewaters from two Outfalls. Outfall 001 is authorized to discharge treated domestic wastewaters per permit effluent limitations. Outfall 002 is authorized to discharge treated process wastewater per permit effluent limitations. At the time of this inspection, it was explained that Outfall 002 was not in use and had not discharge for many years. Use of the Outfall was discontinued due to recycling of process waters. Kristin Malosh, EHS Director North America, said that Outfall 002 is planned to be removed from the 2018 permit renewal application. Storm water permit TXR05P20 was reviewed during this inspection. Benchmark sampling was elevated but, facility is reviewing the site SWPPP in accordance with TPDES Permit requirements. Section III - AREAS OF CONCERN At the time of this inspection, no areas of concern were noted during the inspection. EPA Inspection Report - Page 3 of 3 Section IV - FOLLOW UP No information was received by EPA after exiting the Facility. Section V - LIST OF APPENDICES No Appendices follow.