Document YrD3x0bZ01m2eZOM0pB264Ywn
J
-------JUU5X CORPORATION - *- --------------* INPPSTRXAL HYGIENE SURVEY
iftgpsmgL
AMERICAN BHAKEBLQK....................... WINCHESTER. VIRGINIA
fixmM A4 - 3-8,f, 19.7.2.
This survey was the continuation of a study Which was initiated
to determine the extent of'asbestos exposure to employees in. . .
the Plant. Additional'surveys will be scheduled to complete
the evaluation;
'-
- i.v.
i\
**''* *'
. -X*
--y* i.
,, . m*, ,v t *
Several of "the asbestos samples collected from locations pro
cessing lead compounds were also selected for lead analysis 1
to determine airborne concentrations at various operations.
.
Samples were collected in five-different departments through- .
out the Plant# including Book Preform# Book Press# Block Preform#
Strip Finishing# end Inspection and Packaging. . -
...
The results of the asbestos study disclosed two (2) locations
where airborne asbestos concentrations were above the current
eight-hour time weighted average exposure limit of 5 -fibers/ml.
. h.
Referring to Sample No. 15 in. the Analyses of Air Samples for
Asbestos# the concentration found at Maahine No. P-11# operated
by c. Orndorff was 6.01 fibere/ml. Exposure levels at* other
Block Preform machines in the area were also elevated# but did
not reach the 5 fiber/ml exposure limit* It was noted that
the mix is handled intimately by the operators during the pre
form cycle. In addition' to manually transferring the mix from
container to the mold# the'material is measured and spread by
hand. As none of the Preform units are provided with adequate
exhaust ventilation# the continuous manual operations are
generating increased airborne concentrations of.asbestos fibers.
- *
' -
,-
-.........................
5.................................
Sample No. 56; at a concentration of 5.37 fibers/ml# was .
collected at the vertical saw adjacent to the Book Press De
partment. The saw was operated by R. F. Putnam# and was in
nearly continuous use during collection of the sample. The
unit is not provided with local exhaust ventilation# and sig
nificant quantities of airborne particulates are'generated
abex-121
SPNY 003351. SCF-ABEX-1500