Document Yr73jqDr4z8Xk4OzKJXm148k
TO FROM
ETHYL CORPORATION
INTER-OEEICE MEMORANDUM
Dr. R. A. Kehoe rl. K. Ball
dat e subj ec t
July 24 > 1950
Eastern States Pet. Co. Houston, Texas
Referring to our letter of July 21, we are attaching hereto a letter from our Mr. Gerber which discusses a note received one month ago on this subject. In order that you may have the information on hand, we are attach-
Hr* H,, l^:;: Ifall
H. J* Grber
Eastern States Petroleum Go., Houston Alleged Poisoning Case
Tulsa Houston Juiy 2i* 1950
Dear Mr* Balls
This will confirm our telephone conversation of early in the day, and I am hereby quoting Mr* Teanent's note of roughly one month ago.
,!Jak0~A. Mr* Brown of Eastern States called from the first aid station, Wentworth 1651*
Said he had a no good negro who claimed to have lead poison after he was fired was there*
The only chance of a lead exposure would have been in tank 108 if he worked on that job* To the best of their knowledge ho did not. Asked if Gerber had any record of the men who worked on the job in Koveaber*
The aan*s name is Sceft* Gerber on the attached report shows 8 men working in the task but Scott was not one of them.
I gave this information to Mr* Brown and suggested that he contact you if he needed any further help or infor nation."
Mr. Brown again contacted this office today and indicated that Hr* Tholo Scott was filing suit against Eastern States* insurance company* Mr. Brown requested ifaat our Medical Department be notified of this case and that no further action be taken on our part until a specific request has been Bade by Eastern States.
I have checked the tank cleaning records on tank Ho. 108 that was cleaned in November of last year and since this apparently is the only possibility of exposure for Mr.# Scott 2 doubt very much if he has contacted any lead poisoning as lie does not appear on the tank cleaning records either on the actual cleaning job or on the repair work. This is ms rely for yo: r infornation and 1 will keep you advised of any further developments
Tory truly .yours0.
WG,"HSfe,. KE 0017281
H. 01. GERBER
N21027.01
ETHYL CORPORATION
Approved for Region
TANK CLEANING REPORT (Including the entering of a leaded gasoline storage tank for any purpose)
VC Region.. Southern,-
,iner or Operato.r-of Tank :EasteKai; .Ste-:teU-.P-&'^*-.-;QolElC *
Date. This; Report:--,.^......J2^&?-49-- :r-;-3---.................
Aocation: IT..;.-,'..-............ ,Houston-,' Date'First'Entry:..'............. .11-2114?............................
Work Authorized by:............ ----P-l- SfreC -;........
Identification;,--,,1Q3i;t,
5. Classification:Ref.- S.tg*--
c>. Type of Tank-Horizontal,.*.Vertical.^Floating Roofl-.Other............
Capacity in Barrels:..,' ......................... .94,-000..... ...............................
10." 'Date 76b Completed:,,............................................................ U- Total Working Days;.,,................. 18. ........... ................ 12. Ethyl Attendance at-First Entry: YesX.......No.......... 18* Total Days Attended;.,..................... 18................................
14. Tank reported to be below combustible vapor hazard before entry for cleaning (or repair); Yes,,X--No.,:....... -Unknown..........
15. What method used to remove vapor:
Before Cleaning
During-Cleaning - .. 'After Cleaning ~~ ~
Steaming
Natural_ Ventilation
Suction-Type,Air Mover
Blower
'.-U j--
, Other.,
16. Did foreman understand relative significance of "lead vapor hazard": .
...................................... Ye&X--No..............
17. Equipment in good condition and inspected by responsible individualbefore work began:.................................. Yes.,X,,No,--........
IS. Sufficient prescribed equipment on hand:............................................................................................................................... Yes...X,,No..............
19. Did E.C. lend any equipment: (If "Yes", list under REMARKS)...................................................................... ............
Yes,,......No,,X,,
If "Yes", did foreman 0:K. condition:......................................................................................... ............................................Yes..............No.,:......
20. If tank entered, for what purpose: . . . Cleaning..... X......
Repair--X-........
Other,.,,..... ---cJ':
.21 If cleaned, for what purpose: Routine..........Change of Product........... Contamination.......... Repair.-,,,,., Dismantle.,;....... Other..........
Comments: ................................................................... :Pos&Ibl.e,new,Wttom-aad-roof,-rep^irs,,,,-',,,-,..............................
ETHYL TANK CLEANING PRECAUTIONS FOLLOWED IN EVERY RESPECT: Yes.,;,,,,Nol.X. (If-"NO", explain under
r e ma r k s .)
* " - ...
23- At the, conclusion of the cleaning--
. ", "7"*.,
a. Were all sludge and nonadherent material (including loose scale) that had been in contact^with'.sludge.' .7
removed:............................................................................ ...... . Did E.C. representative enter tank: ......................... ......
'> .
1'4 Yes,-x---No.......... . ' Yes, v No..........
c. Was an "Ethyl" Lead-in-Air Analyzer test made: (If "Yes", record'data under Item 27)
* . . :,Yes,,,x---No..........
d. Was tank safe for entry without protective equipment from standp&inr of lead hazard:' .
\ * V ' Y5s,,x,,No..........
24. Did or will men re-enter tank: Yes.,X...No,........ (If "YES",,for what purpose; describe under REMARKS and state further
precautions taken or recommended.)
"" "
-- - - - -
" *' *
25. What service is tank returning to: Leaded.'.'.'--7~,' UnleadM,--X,; Dismantle--,--7, 'Other';,',.---- tlf'"Other", explain under
REMARKS). .
,
.
, .,
_ .. _
.
.
a. If "UNLEADED"/ do you recommend that Ethyl Tank Cleaning Precautions be followed oniiext' cleaning: ` Yes......... No,,X~
b. If "YES", has Unit of Authority been notified:......................................................... ..................................... *7 . ' Yes........... No..........
26. Date and time.cleaning completed:,,................. .......... ,.3tOQ
- .................................
27. RESULTS OF "ETHYL" LEAD-IN-AIR ANALYZER; TEST Test Number Date and Time of Test Micrograms of Lead Per Cu, Ft. of Air
Remarks
.....1...... .....2...... .....3...... .....4......
--900--pm... 11--26--49 -10;00--siall--26-49 10:30-221-11-26-49
...... Q-... 2
4.... ... 5.....
-Tank-very.-clean-EJG........ -^o-air-mover-WAN.............. No-air-mover-WAN-............. -No -air- mover,.....................
28. REMARKS: List name or badge numbers (both if available) of all individuals who jmtered tank and total time spent by each person, as well as other pertinent information not elsewhei'e included.
5 11:00 am 11-26-49 6 10:00 am 11-27-49
7 8:00 am 11-28-49 8 9:00 am 11-28-49
0 1 1/2
3 5
Air mover turned, on AN Air mover used all night ETGAir mover used all night WAN Air mover used all night WAN
-over-
-10M`-41822 --3-49,
H. J. 6ERBER & W. A. BEHHftK ".......
Ethyl [Corporation Representative
(Use reverse side if necessary)
KE
0 W 7282
N21027,02
<;;A Continued
Hftl y A ii.OTH c :>
4 a Tit
!`:;0*T3:sr'ky^yj. ,.,;j on:
t!i lot -*U: - ; ' :;-!fX
'u .,h>i r.
J j-
;
5
-V -
-A,
'St
Test . Jhimbef c
Date
&
Time
of
Test
''Micrograms of Lfead1-' per Cu. FtV of -Air
'x u'`2
'
''l
Remarks
:X:- .
9
9:30 am. 11-28-49
* ^1/2
Air mover used all
%*je
10 . 12 noon 11-28-49 11 2:00 pm 11-28-49
-3 15
-v :
Air moversus:e<S': sH.:^!qgSt ask Air mover off '
12 4:00 pm. 11-28-49 4 Air mover off
13 5: OOrH-28-49
2 Air mover on
14 ' 9:00 pm 11-28-49
10 Air mover on
15 10:00 p.m. 11-28-49
15
Mr mover off
16 11:00 pm 11-28-49
4 .. Mr mover on
17 - 9:00 pm 11-29-49 1 Mr mover on
18 3:00 pa 11-29-49
1/2 M.r mover on
19 10:00 am. 12-8-49 0 Air mover off.
#28. g83e
891 892 905 906 1014
894 P 910 H. 912 L. 2770 S.
2783 C.
30 hours 30 hours 30 hrsi ^ 30 hrs 30 hrs. 30 hrs. 30 hrs. ' 30 hrs. 30 hrs. 30 hrs.
#22.
entered the tank for a period of five minutes without the
gas mask. TEiFlms been handled with the foreman.
#24. Requested that .air mover be used for all inside vrork as tank has leaking
bottom.
-
12:00 Noon 11-28-49--Holes in bottom plugged dnd two (2) additional air movers installed.^---------
- -- :. Xisel::.
V
uiy X6Vtj"
- . /LUf.
o4-i-
> on,-
': 0V'-'- : ' ~sH
l
* ..... ; - . * :' * ; :
: * sJ -
/<" 0017283
U1104