Document Yr61rEL2o5kpj2Jb9ZamLOmNn
Monsanto
. ..... .
SC. Louis - General Offices Hay 11, 1970
1 O H. S. BERGEN J. E. SPRINGGATE
W. B. Papageorge
Attached hereto are copies of charts I used In the presentation with the CMC this morning.
The CMC gave Its approval for us to implement the plan as outlined on the two sheets marked "PRESENT PLAN".
We are required to report to the CMC should we make any major deviation from these plans and we are also required to make a progress report probably around the 1st of August. Would you please go ahead and take the necessary action within your Individual business groups and keep me advised of progress.
Att.
JOHN MASON
MONS 200948
COST OF RAPID PHASE-OUT
ALL CHLORINATED
BIPHENYLS EXCEPT DIELECTRICS
1970
LOSS IN SALES LOSS IN GROSS PROFIT
-
$ 5.4 M $ 2.6 ji
IN ADDITION COGS WOULD INCREASE GIVING TOTAL LOSS IN GROSS PROFIT OF - $ 2.75 it.
1971
LOSS IN SALES
- $ 12 M
TOTAL LOSS IN GROSS PROFIT - $ 6.1 "l
PLUS POSSIBLE WRITE-OFF OF SOME 5 2.6 li KJtUMMRICH AROCLOR FACILITIES.
MONS 200949
OBJECTIVE TO MAINTAIN A PROFITABLE BUSINESS SERVING THE NEEDS OF FUNCTIONAL FLUIDS USERS AND THE CAREONLESS DUPLICATING PAPER INDUSTRY WHILST MINIMIZING THE ESCAPE OF RON-BIODEGRADABLE BIPHENYLS INTO THE ENVIRONMENT.
HONS 200950
ACTION TO ACHIEVE OBJECTIVES
1) MARKET NON-BIODEGRADABLE CHLORINATED BIPHENYLS ONLY FOR CLOSED SYSTEM APPLICATIONS WHERE CONTROL IS POSSIBLE.
2) PHASE OUT OF ALL NON-CONTROLLABLE APPLICATIONS REPLACING WITH BIODEGRADABLE CHLORINATED BIPilENYLS OR OTHER SATISFACTORY PRODUCTS.
MOMS 200951
THE
CLOSED
LOOP
>
REGEIii'RATION &
RECYCLE ':rrrr:
A
PCB's usage
>
INCINERATE
\/
.cr.rjTru;r:::-Si-i
/V
ADSORPTION
V FROM
jAIR C. WATER
BIODEGRADATION i*TT=.^a--
MONS 200952
5
DO W HAVE THE CAPABILITY TO CLOSE THE LOOP ?
HONS 200953
BIODEGRADATION
1) GOOD PROCRESS AT BOTH RUALON AMD ST. LOUIS.
2) LONER CHLORINATED ISOMERS RESPONDING WELL, BUT 5 & 6 CHLORINE ISOMERS EITHER MOT RESPONDING OR VERY SLOW.
3) CRITICAL PRODUCT IS 1242, CONTAINS SOME 50 ISOMERS
-- GOOD RESPONSE ON 2, 3, & SONS 4 CHLORINE
ISOMERS.
.
4) W0RX IN HAND ON FRACTIONATED 1242 GOOD PROGRESS TO DATE.
MONS 200954
I FIGURE 1 HONS 200955
FIGURE 2
Semi-Continuous Activated Sludge Blodegradation
I \
Aroclor 1242 Mixed Liquor Before feeding 72 Hour Exposure
3
3
/,
l
[4+5
4
4
!
&
1
Aroclor 1242
Mixed Liquor After feeding
1 ii 2 H6
><
*
*o `Z-
HONS 200956
FIGURE 3
MONS 200957
REPLACEMENT ' PRODUCTS
7.
1) 1242E SHOWS'GOOD PROPERTIES AS CAPACITOR DIELECTRIC NOW MAXING 500 GALS. AT DAYTON FOR CUSTOMER TRIALS. ALSO WORKING ON 1230B.
2) GOOD PROGRESS ON PHOSPHATE ESTER REPLACEMENTS FOR
.
HYDRAULIC FLUID APPLICATIONS. -- TCP -- CDP --
TBP ~ NONYL PLlENYL/COMYL PHENYL DIPHENYL PHOSPIiATE.
3) HEAT TRANSFER FLUIDS -- USING MAINLY ESTABLISHED
PRODUCTS, E.G. KB-40 -- EXAMINING POSSIBLE ENTRY
INTO DIPHENYL OXIDE PRODUCTION EITHER OWN PROCESS OR
LICENSING.
MONS 200958
TOXICITY
1) NO CHANGE SINCE LAST REPORT - HAVE DISCUSSED RESULTS WITH DR, BURGER, EXECUTIVE OFFICE OF THE PRESIDENT,
2) WE HAVE ANALYZED AROCLORS 1243 AND 1254 FOR OCTOCHLORO DIBEN20 p-DIOXlX -- NONE FOUND.
3) CENTRAL INSTITUTE FOR NUTRITION AND FOOD RESEARCH, ZEIST, HOLLAND -- EXAMINED EAYER,PRODELAC AND MONSANTO CHLORINATED BIPHENYLS FOR DIEEXZO FURANS -- NONE FOUND IN MONSANTO MATERIAL.
NQNS 200959
INCINERATION
1) SUCCESSFUL TRIAL AT JOHN ZINC CO., TULSA. 1242,
1260, 1254 DESTROYED AT 2000 F.
OFF GAS HCl.
ENGINEERING WORK NOW IN HAND TO BUILD SUITABLE
INCINERATOR. ESTIMATED COST 250,000 K.
2) INTEND TO CARRY OUT FURTHER TRIALS ON STILL
BOTTOMS.
`
3) INCINERATOR PROBABLY LOCATED AT KRU503ICH.
HONS 2009*0
c i-i v;r
r- . * L. . . ___ I
3,000 ppb
n.
500 ppb
lVo'7 I'rcfiMil
50 ppb
r--
10
-p-p--b-,
l.M i;i l r.
1/71 9/71
a: 5 Iby./il.'y
2W) lbi.Al.iy
-i . 70 .
l9by l'ri'`.cnt
--------- -------
n:i-|'0 ;T - 0. 5 tbs. t- .
HONS 200961
12.
CLOSING
THE
L\OOP
FOR
INDIVIDUAL
BUSINESSES.
HOMS 200962
13.
TRANSFORMER 6 CAPACITOR DIELECTRICS 1) RESPONSIBLE INDUSTRIES USING 1254 AND 1242, 2) FIRE RESISTANCE EXTRE>XLY IMPORTANT. 3) COLLECTION AND RETURN OF SPENT AND ARCED FLUID, 4) REGENERATION AND RECYCLE. 5) TRIALS PLANNED FOR 1242B AND 12303 IF SATISFACTORY. 6) LABELLING OF ASXAREL TRANSFORMERS,
HONS 200963
HEAT TRANSFER FLUIDS
1) EDUCATION OF USERS WHERE FIRE RESISTANCE IS OBLIGATORY -- MAJOR INDUSTRIAL CORPORATIONS -- E.G. GOODYEAR AND CHEMICAL COMPANIES.
2) PHASE OUT OF ALL FOOD APPLICATIONS -- LETTERS WILL BE SENT OUT MAY 15th -- NO SALES AFTER AUGUST 15th - WILL COLLECT AND DESTROY OLD FLUID.
3) INSTITUTION OF REGULAR COLLECTION REGENERATION OR INCINERATION SERVICE.
it) PHASING IN NEW PRODUCTS WHERE CONTROL NOT POSSIBLE.
HONS 200964
15.
HYDRAULIC
FLUIDS '
1) RECOGNIZE THAT CONTROL 0? SPILLAGE AND PUMP LEAKAGE MAKES THE USE OF NON-BIODEGRADABLE CHLORINATED BIPHENYLS UNDESIRABLE.
2) ALREADY REFORMULATED PYDRAUL 625, ACWG, 280 and F9 -- REPLACEMENT COMPLETE BY AUGUST 1
3) OTHER PRODUCTS IN INTERIM STAGES (E.G. PYDRAUL AC FORMULATION ON COMPRESSOR' TEST AT JFQ) .
4) AIM TO COMPLETE 90L PHASE-OUT EY DECEMBER, 1970.
*
HONS 200965
16,
N. C, R.
1) U.K. HAS( APPROVED HB-40, NOW PLACED REGULAR ORDERS -- EXPECT COMPLETE PHASE-OUT BY 1st JULY.
2) U.S. RUNNING TRIALS ON M.I.B.P., EXPECT DECISION 22nd MAY -- PRELIMINARY INTERIUM PRODUCTION OF 40 M POUNDS PER MONTH TARGETED FOR 30th AUGUST -- PLANNING FULL SCALE PLANT 10 N LBS. PER ANNUM ON STREAM END JANUARY 1971 -- ESTIMATED NFC $1 - 1.2 M.
HONS 200966
17.
PLASTICIZE & MISCELLANEOUS APPLICATIONS
1) DISTRIBUTORS ALREADY ADVISED NO V.ORE SALES AFTER 30th AUCUST. (200 CUSTOMERS)
2} LETTERS TO 661 CUSTOMERS WILL BE SENT OUT 27ch KAY
ADVISIRC RO MORE SALTS AFTER 30th AUGUST --
'
DISPOSAL INSTRUCTIONS WILL BE GIVER.
3} IN CONTACT WITH U.S.D.A. THROUGH AG DIVISION OR SILO PAINT PROBLEM.
4} BY 30th AUGUST ALL BUSINESS LN THIS AREA WILL BE PHASED OUT.
MOMS 2009*7
? ~ s ^ :: ?
? an
1) terminate sales or all sc^licdzc-udalle czlc.mm7;e: EII'AZ'.TYLS TO N`OS-CO:"AOL1AE:.Z 2ND JiJS, . COALITE - A'20'JET 2C*.h, 1C7S.
2) L:Lcc;r::N'j2 sale of arcslg;< 1222 70 :<zk a:d lefl-cz
COM?LET - J.K. -- t/ ** M -- f i J t \J
COIE-'LETE - U.S. -- JAMJAR 30*.!'., 207:
3) Cl.C T;; LOO? CS
?/:< IS VITAL AMD REPLACE L'ITV. ALTE'ASATLS IS CTS;. CASES.
COJCLETZ - DECEMSE:. 30:L, 2070
MONS 20096a
4) KIPLAC3 .\ i.*,
.V'.Ja.
.U1IC ,\ PPL ICAHC..3 k
c .-. icazrj-zio i :?i;r.:vis
C0>?'L:T3 207, " 407. " 1007,
ALOIST Is:, 1570 ;;0V2M.i:\ Is:, 1570 D`iC>225 LG:h, 1570
5) . CLOSE
LOO? CX ALL XOX-E'CLLSXADAOLE CKLCRZUttSO
ai?i-:zNVis ix T-Vi.'sroixii applications.
CC^LSTL - AUG-SI Is:, 1570
CLOSE T13 LOO? Cl* CAPAC-TGXS AS PAH AS PCS31 -11 AlO
1242 WIT;-: 12423.
`
CC'.IlllE -
01s:, 1570
HONS 200969
\
-PW*'4ld^^k ~ rf****.C>.A^*** I4
iWk hi ad m WkS '
:.:,,? c.-.r-vvcirv - Aosiorox ?
$ 275. C.70 $ 250, CM
$ 1,000,003 $ 1,200,000
W * te/ * vV m **"*n<* ^ nwkk*M* ttW^* iV* * J?Q
. ye
tic ft**-,*
Wl\/*^*<W \ IKIkM W M\ * *
- $ 2S5,C;
rotAi
72X10 ca?*:'a;
$ 3,555,000
-
e'
\
NONS 200970
/
I
I
^-
r*
*- .*v v
cr.Cii' iwss^zx? , # C*
$ 22.ao: $ 3.5 a
iY *m * f4t vi* $ 25.4 ::
..51
aa^..a:
>i *.V* i^> **1
*. 4 s.c:: 4 2.7 5 29.3
.. ,1*.' *.-
HONS 200971