Document YnjJ94vgQqMVLjZy5Epd8zQn
Monsanto
...C..-
e. Stewart, Krummrlch
H'lHWl
July 27, 1972
POLYCHLORINATED BIPHENYLS AMD THE ENVIRONMENT
TO Mr. Paul Helslar Director of Environmental
Control at WOK
COMPANY CONFIDENTIAL
" 0. L. Bratsch W. C. Engman O. A. Hlppe P. B. Hodges - 0.0. (E1SF) A. E. Lelsy W. B. Papageorge - 0.0. (B2NA) J. R. Savage - 0.0. (B2SL)
During the past three years, varied actions have been
Implemented at the W.0. Krummrlch manufacturing facilities to restrict and reduce Polychlorinated Biphenyls (PCB) entrance Into the environment.
Major activities cam be summarized as follows. More details related to the specified areas are attached.
'> '
I. The total production of Aroclors at the W.O.K. Plant )
y ; Veached a peak in 1970 and has since decreased by 16#.
-A J \T II^{VProduction of the higher chlorinated homologues.
(A c
(Aroclor 1248 and above) has decreased about 60#
^ since 1969.
^ >
III.
Manufacturing facilities were Installed to produce a
more biodegradable homologue In the chlorinated biphenyl series. Aroclor 1016. Expect about 60# of the 1972 total production to be Aroclor 1016. ($970,000)
IV. Container alterations made (heavier metal drums).
V. Product labeling changes to reflect possibilities of environmental contaminant, restrictions for use of thermlnol and opportunities for waste disposal by Incineration.
VI. Installation of facilities to permit reworking and/or Incinerating PCB'a returned from the customer as a means of waste disposal. ($790,000)
VII.
Restricted usage within the plant outside of the manu facturing department to electrical equipment that con
tains Aroclor as an Integral fluid contained within the respective piece of equipment. ($80,000)
MUNS 09943d
Mr. Paul Helsler POLYCHLORINATED BIPHENYLS AND THE ENVIRONMENT
WOK
VIII.
Equipment modifications and Installations were made to
restrict, contain and monitor knowing losses of PCB's to the lowest technical achievable level within the manu facturing department. ($170,000)
IX. An educational program Is being directed to the operating personnel related to good housekeeping and the need for care to control and contain Aroclor wastes 1n the manu
1facturing areas.
r
Needless to 'Say, such activities as listed above to control and contain PCB losses, require a dynamic action control program. Many people are Involved from the operators, first line super vision and superintendents at the operating level to the technicians, chemists and engineers In the laboratory, environ mental control and engineering departments.
Edward E. Stewart Technical Services Department
/tm attachments
MGNS 099439
CONTAINER ALTERATIONS MADE
During this period a heavier metal drum was substituted
for a lighter weight drum. The metal thickness was
Increased by 26$ when the 18 gage drums were replaced
with 16 gage drums. Both side walls and heads were
Increased In thickness. Double chimes are provided on
the heads for added strength.
-
The heavier gage drum affords more protection against
possible leakage due to damage In handling and trans porting.
i MONS 099441
LABELING CHANGES The following Additions were added to various labels: "This product contains polychlorinated biphenyls, which
some studies have shown may be persistent, air environ mental contaminant and, possibly, injurious to certain forms of bird, aquatic and animal life. Extreme care should be taken to prevent any entry into the environ ment through spills, leakage, use, disposal, vaporization or otherwise." "HASTE DISPOSAL Used polychlorinated biphenyl fluids may be returned freight prepaid for proper incineration at 3^ per pound. Ship to: Supervisor, Dept. A-246, MONSANTO COMPANY, SAUOET, ILLINOIS 62201" ATTENTION - DO NOT USE IN ANY SYSTEM INVOLVING PROCESSING OR HANDLING OF: Food or food related products; Food wrapping or container materials; Pharmaceuticals or animal feed stuff. ANY CONTACT MAY CONTAMINATE THESE ITEMS TO THE EXTENT THEY MUST BE DESTROYED." in CASE OF LEAK OR SPILL, CALL COLLECT 618-271-5835.*
MUNS 099442
Equipment was Installed to permit the Incineration of
liquid waste Aroclors. Complete incineration of the
liquid waste is affected by incineration at SOOO'p. Facilities are available for handling waste Aroclors from tank cars, tank trucks and drums.
Effluent streams from the disposal facilities are
closely monitored to assure that knowing losses are
controlled.
,
Th C/nr****^ T
TV F S'*
MOMS 099443
EQUIPMENT MODIFICATIONS AND INSTALLATIONS WITHIN THE MANUFACTURING DEPARTMENT FROM 1969 TO 1972
Numerous projects were completed to eliminate atmospheric discharges, to eliminate discharges to the sewer and to contain PCB's within the manufacturing department that may have resulted from accidental spills or equipment failures. A. Atmospheric vents and rupture disc lines were rerouted
through catch tanks and/or redirected to settling basin areas. B. Nitrogen blanketing provided on storage tanka. C. Mist eliminators Installed In gas lines. D. Settling basins were Installed in sewer system. E. Areas were paved, curbed and sewer trenches directed flow to settling basins. P. underground sewers were mounted above ground or repaired to eliminate build-up and cross flows of underground PCB contaminated waters. 0. Sewer sampling facilities and flow Instrumentation provided. In addition all Thermlnol heating units In the plant were converted to non-PCB type fluids. During this period laboratory equipment was purchased and plant expertise was developed to analyze streams for PCB's In the ppb range.
MUNS 099444