Document YjqEJvvMK8kw6dk3en7Jr722y

Aim. Ocnp. My$. Vet. IJ, pp. JT-JI. hrpaoo Ptm IfTO. Frioud la Grew Brfttla INVESTIGATIONS INTO ALTERNATIVE FORMS OF CONTROL FOR DUST GENERATED DURING THE CLEANING OF BRAKE ASSEMBLIES AND DRUMS* K. L. Knight and D. E. Hickbh Medical Services, Ford of Britain, Brentwood, Essex INTRODUCTION The most usual method of removing the accumulated dust from brake drums and assemblies is by "blowing off" with a compressed air stream. This, ofcourse, generates a dust cloud in which the operator works, proportionate in size to the drum/assembly being cleaned. We therefore investigated two alternative methods of controlling dust generated at a maintenance operation on commercial vehicles, as representing maxi mum likely exposure. Enquiries at the beginning of the investigation indicated that the removal of dust is to allow inspection of the mechanism, rather than being a maintenance procedure in itself. Our efforts were, therefore, directed towards the removal of loose dust from the parts of the brake mechanism which needed inspection, rather than achieving total cleanliness. The criteria for evaluating the two methods devised were firstly, that the alternative method did not take significantly longer than the method already in use, secondly, that it was not more difficult to carry out, and thirdly, that very little extra equipment was needed. ALTERNATIVE METHODS EXAMINED The alternative methods examined were a vacuum funnel, and a vacuum brush. Vacuum funnel The funnel (see Fig. 1) comprised a steel cone with a connection point at its apex for an industrial vacuum cleaner; a flexible skirt, with a draw string attached at its periphery; and a small-bore side-entry for the injection of compressed air. In use, the funnel was secured over the backplate of the brake assembly or over the drum and compressed air was injected to dislodge dust while the vacuum cleaner extracted dust-laden air. The assembly was rotated around the total circumference to complete the cleaning operation. *Thi paper was originally presented at a Conference on Exposure to Asbestos during Brake and Clutch Maintenance, held at Brentwood, Essex. March, 1969. 17 SCF-FA-6340 P-EXHIBIT-245 i 38 K. L. Ktooht tod D. E. Hkxoh Vacuum brush ' The vacuum brush shown in Fig. 2 consisted of a circular nylon bristle brush mounted on an angled handle and fitted via the handle to the same vacuum cleaner. In use, the brush was used to remove dust from drums and assemblies under vacuum. EXPERIMENTAL PROCEDURE In order to determine which of these two methods was the better, the performance of each was compared with the traditional blow-off method, in two separate experi ments shown in Table 1. ' Tabu. 1. Efftcr or cuamno ksthoos on dust concsmiuatioks Hour Activity Personal sampler Static lampler Peak sample particks/cnp fibres/cm* particles/cm* fibres/cm* particlca/cm* fibres/cm* - Personal sampler Static sampler Peak sample particlea/cm* fibres/cm* particles/cm* fibres/cm* particles/cm* fibres/cm* - 1 Background 2 Blow-off 3 Background 66 Funnel Brush cleaning cleaning IK 422 107 413 0-96 3-33 093 3-3 161 72 162 210 043 0-32 0-41 0-73 41730 739 87 1*04 123 633 0-16 084 129 133 0-10 0-16 41730 87 140 0-09 110 0-20 138 0-22 122 0-18 310 0-37 ; 1 i i During the first hour of the day air samples were collected to determine background concentrations; during this period the near side front road wheel was removed. In the second hour samples were collected during dust removal from the near side brake assembly by blow-off. Further background samples were taken during the fifth hour while the off side front road wheel was removed, and during the sixth hour dust ' determinations were made while either the funnel or the brush cleaning methods were used.' - The personal samples were collected from the breathing rones of mechanics en gaged in the work and static samples were collected concurrently to simulate exposure of mechanics working in an adjacent repair bay. Short duration samples were also collected by means of a Drfiger pump from the operator's breathing zone at the peak period of dust generation. '' All the samples were subsequently analysed for fibres in accordance with the technique laid down in the Hygiene Standardfor Chrysolite Asbestos published by the British Occupational Hygiene Society (1968). Particle counts were limited to particles greater than 1 ft dla. K Alternative fomu of control for dust generated during the cleaning of brake assemblies 39 DISCUSSION The results for the vacuum funnel vs. blow-off experiment and for the vacuum brush versus blow-off are shown in Table 1. It can be seen that the background concentrations during the fifth hour had re-established at the original level after a 2 hr latent period and therefore the blow-off operation carried out during the second hour did not affect the concentrations observed in the vacuum ftinnd samples collected in the sixth hour. The ftinnefappears to reduce personal exposure by 2 per cent for particles and 40 per cent for fibres; concentrations observed in the adjacent bay are increased and a reduction in peak concentrations ofabout 90:1 was achieved. During the second experiment there was more variability in the background con centrations between tbe first and fi/Ut hour* but the effect of blow-off on the vacuum brush test may be discounted. Personal exposure by use of the brush is reduced by 75 per cent for both particles and fibres and the static samples show a reduction of 20 per cent for particles but an increase of 12 per cent for fibres. A reduction of 80:1 in peak concentrations was again observed. - CONCLUSION . Tbe experiments demonstrated that the vacuum brush was better in reducing operator's exposure; it had the added advantages over the funnel of being easiet to handle, consisted of fewer, simpler parts and was much quicker than the vacuum funnel. ' ' There are three major reasons for the relative inefficiency of the funnel; its use increased brake cleaning time (and thus exposure time) by a factor of 8, it was difficult to obtain a good seal at the skirt, and imbalance occurred between the necessary air input and the capacity of the available exhaust system, with resulting leakage ofdust REFERENCE Cooomi on Hygiene Standards, British Occuvationai. Hygiene Society (1941) Hytlm Standards for CkrysotUs Asbtstos Dust. Pergvnon Pico, Oxford.