Document YjqEJvvMK8kw6dk3en7Jr722y
Aim. Ocnp. My$. Vet. IJ, pp. JT-JI. hrpaoo Ptm IfTO. Frioud la Grew Brfttla
INVESTIGATIONS INTO ALTERNATIVE FORMS OF CONTROL FOR DUST GENERATED DURING THE CLEANING OF BRAKE ASSEMBLIES AND
DRUMS*
K. L. Knight and D. E. Hickbh
Medical Services, Ford of Britain, Brentwood, Essex
INTRODUCTION
The most usual method of removing the accumulated dust from brake drums and assemblies is by "blowing off" with a compressed air stream. This, ofcourse, generates a dust cloud in which the operator works, proportionate in size to the drum/assembly being cleaned. We therefore investigated two alternative methods of controlling dust generated at a maintenance operation on commercial vehicles, as representing maxi mum likely exposure.
Enquiries at the beginning of the investigation indicated that the removal of dust is to allow inspection of the mechanism, rather than being a maintenance procedure in itself. Our efforts were, therefore, directed towards the removal of loose dust from the parts of the brake mechanism which needed inspection, rather than achieving total cleanliness.
The criteria for evaluating the two methods devised were firstly, that the alternative method did not take significantly longer than the method already in use, secondly, that it was not more difficult to carry out, and thirdly, that very little extra equipment was needed.
ALTERNATIVE METHODS EXAMINED The alternative methods examined were a vacuum funnel, and a vacuum brush.
Vacuum funnel The funnel (see Fig. 1) comprised a steel cone with a connection point at its apex
for an industrial vacuum cleaner; a flexible skirt, with a draw string attached at its periphery; and a small-bore side-entry for the injection of compressed air. In use, the funnel was secured over the backplate of the brake assembly or over the drum and compressed air was injected to dislodge dust while the vacuum cleaner extracted dust-laden air. The assembly was rotated around the total circumference to complete the cleaning operation.
*Thi paper was originally presented at a Conference on Exposure to Asbestos during Brake and Clutch Maintenance, held at Brentwood, Essex. March, 1969.
17
SCF-FA-6340
P-EXHIBIT-245
i
38 K. L. Ktooht tod D. E. Hkxoh
Vacuum brush
'
The vacuum brush shown in Fig. 2 consisted of a circular nylon bristle brush
mounted on an angled handle and fitted via the handle to the same vacuum cleaner.
In use, the brush was used to remove dust from drums and assemblies under vacuum.
EXPERIMENTAL PROCEDURE
In order to determine which of these two methods was the better, the performance of each was compared with the traditional blow-off method, in two separate experi ments shown in Table 1. '
Tabu. 1. Efftcr or cuamno ksthoos on dust concsmiuatioks
Hour Activity
Personal sampler Static lampler Peak sample
particks/cnp
fibres/cm* particles/cm* fibres/cm* particlca/cm* fibres/cm*
-
Personal sampler Static sampler Peak sample
particlea/cm*
fibres/cm* particles/cm*
fibres/cm* particles/cm* fibres/cm*
-
1 Background
2 Blow-off
3 Background
66 Funnel Brush cleaning cleaning
IK 422 107 413
0-96 3-33 093 3-3
161 72 162 210
043 0-32 0-41 0-73
41730
739
87 1*04
123 633 0-16 084 129 133 0-10 0-16
41730 87
140 0-09 110 0-20
138 0-22 122 0-18 310 0-37
;
1
i
i
During the first hour of the day air samples were collected to determine background
concentrations; during this period the near side front road wheel was removed. In
the second hour samples were collected during dust removal from the near side brake
assembly by blow-off. Further background samples were taken during the fifth
hour while the off side front road wheel was removed, and during the sixth hour dust
' determinations were made while either the funnel or the brush cleaning methods were
used.'
-
The personal samples were collected from the breathing rones of mechanics en
gaged in the work and static samples were collected concurrently to simulate exposure
of mechanics working in an adjacent repair bay. Short duration samples were also
collected by means of a Drfiger pump from the operator's breathing zone at the peak
period of dust generation.
''
All the samples were subsequently analysed for fibres in accordance with the
technique laid down in the Hygiene Standardfor Chrysolite Asbestos published by the
British Occupational Hygiene Society (1968). Particle counts were limited to particles
greater than 1 ft dla.
K
Alternative fomu of control for dust generated during the cleaning of brake assemblies 39
DISCUSSION
The results for the vacuum funnel vs. blow-off experiment and for the vacuum
brush versus blow-off are shown in Table 1. It can be seen that the background
concentrations during the fifth hour had re-established at the original level after a
2 hr latent period and therefore the blow-off operation carried out during the second
hour did not affect the concentrations observed in the vacuum ftinnd samples collected
in the sixth hour. The ftinnefappears to reduce personal exposure by 2 per cent for
particles and 40 per cent for fibres; concentrations observed in the adjacent bay are
increased and a reduction in peak concentrations ofabout 90:1 was achieved.
During the second experiment there was more variability in the background con
centrations between tbe first and fi/Ut hour* but the effect of blow-off on the vacuum
brush test may be discounted. Personal exposure by use of the brush is reduced by
75 per cent for both particles and fibres and the static samples show a reduction of
20 per cent for particles but an increase of 12 per cent for fibres. A reduction of 80:1
in peak concentrations was again observed.
-
CONCLUSION
.
Tbe experiments demonstrated that the vacuum brush was better in reducing
operator's exposure; it had the added advantages over the funnel of being easiet to
handle, consisted of fewer, simpler parts and was much quicker than the vacuum
funnel.
'
'
There are three major reasons for the relative inefficiency of the funnel; its use
increased brake cleaning time (and thus exposure time) by a factor of 8, it was difficult
to obtain a good seal at the skirt, and imbalance occurred between the necessary air
input and the capacity of the available exhaust system, with resulting leakage ofdust
REFERENCE
Cooomi on Hygiene Standards, British Occuvationai. Hygiene Society (1941) Hytlm Standards for CkrysotUs Asbtstos Dust. Pergvnon Pico, Oxford.