Document Yjq8QN555BzaOvLwONEO0wBwK

* REPORT HO. 2892 INTERIM REPCRT OH AROCLCB IN GASES Job Ho. 171-1089 June 17. 1955 H. B. Richards, Jr RESEARCH DEPARTMENT Phosphate Division MGNS 058945 Report Ho. 2892 INTERIM REPORT ON AROCLOR IN OASES Job No. 171-1089 File No. jjsigtarc'ly Dwarl^t\i Work Started: 5-8-53 Work Completed: 6-16-53 Report Submitted: 6-17-53 Prepared Bp: H. B. Richard*, Jr. Chemist*: A. M. Ellenburg H, B. Richards, Jr. 18 conies were msde of this rsport and distributed as follows: No. 1 No. 2 No. 3 - No. 4 No. 5 No. 6 No. 7 No. 8 No. 9No. 10 No. 11 No. 12 No. 13 No. 14 No. 15 No. 16 No. 17 No. 18 Research File R. L. Jenkins - St. Louis J. L. Christian-T. K. Smith - St. Louis H. F. Weaver - St. Louis C. A. Hoohwalt - St. Louis N. N. T. Samaras - Dayton E. E. Hardy A. M. Ellenburg H. B. Richards, Jr. P. C. Benlgnus - St. Louis R. E. Kelly - St. L uis P. G. Benlgnus - St. Louis P. G. Benlgnus - St. Louis P. G. Benlgnus - St. Louis P. G. Benlgnus - St. Louis P. G. Benlgnus - St. Louis MONS 058946 This is Copy No This report and the information contained herein is the property of " MONSANTO CHEMICAL COMPANY CONFIDENTIAL This report and the Information contained herein is the property of the Monsanto Chemloal Company, and should he oor sldered confidential. It should be retained by the recipient, and not copied or loaned to others. MONS 058947 l. TABLE OF CONTESTS I. II. III. IV. V. VI. VII. PW W9. Introduction ........................ Summary ............................. Referencea ............................. Experimental Work ... A. Experimental Data B. Negative Resulta . . C. Preoleion and Accuracy Diaouaalon ............................. Conolualona ........................ Recommendations .... Appendix ......................................................... Sampling Positions................................. Operating Procedure for Vlllson Product's, Incorporated, Chlorina ted Hydrooarbon Sampling Apparatus Data Sheet - Aroolor Vapor Detection.................................................... Diagrammatic Sketch............................. 8 12 13 I i HONS 058948 1 INTRODUCTIONi Dow Chesjloal Company Is Interested In using Aroolor as a plasti cizer in styrene latex paint systems. Research at the Plasties Divislonj's Springfield laboratories has indicated that use of suoh paints in enclosed areas under certain conditions results in Aroclor vapor concentrations above the accepted safe maximum for continuous exposure. For this reason Dow is dubious about the use of Aroolor for this application. The Sales Department, therefore, requested that experiments be oarried out in the Aroolor plant at Anniston to determine the Aroolor vapor concentration to whloh the operating personnel are normally exposed. This data can then be submitted as evi dence that exposure to this concentration has had no apparent toxlo effects upon the operators. This work was undertaken to determine the usual Aroolor vapor concentrations in the plant. II. SUMMARY; The ohlorine content of the air in the Aroolor plant has been determined at several positions and under various conditions. Willson Product's, Incorporated, apparatus for determination of ohlorlnated hydrocarbons was employed for these tests. (See Appendix). The Aroclor vapor oonoentration was found to vary widely depending upon several factors including location of sampling apparatus, operations being carried out, directions of drafts through the still room, and temperature and boiling point of the Aroolor under question The actual Aroolor vapor concentrations varied from about 0.35 mg. per cu. meter to about 5.0 aig. per ou. meter under the most severe ooiditions. No definlt* average concentration has been established. It was found, however, that the Aroolor vapor oonoentration in the air at the sample points is seldom below the 0.5 to 1.0 mg. per cu. meter level, which is the maximum tolerable con centrations (according to Elkins, see References). and often is as high as 3 to 5 mg. per ou. meter. These higher concentrations are extremely Irritating to the eyes, nose, and throat. On the basis of these facts it is difficult to conceive that concentrations in the range of 1 to 5 n%. per cu. meter reported by the Plastics Division as a result of painting with an Aroclorcontalnlng paint oould be attained under normal conditions with this type paint. It should be further noted that nearly half the teelts in the plant showed less than 1.0 mg. Aroolor per cu. am ter, land about two thirds of the tests showed less than 2.0 mg. Aroclor pbr cu. Bieter, and only about 5.0 Big. per cu. meter under the most severe conditions. It is recommended that this laboratory secure a sample of the paint under question and make tqsts with it to determine the resulting Aroclor vapor con centration in the air. HONS 058949 -2- Sampling of the air In the plant will also he continued until more complete data are obtained on all of the Aroclora. ,, "The Analytical Chemistry of Industrial Poisons, Hazards, and Solvents," second edition, Inter science. New York City, 1949. MillhlBer, F. R., "Determination of Halowaz in Air," Report from Dept, of Physiology, Harvard Sohool of Public Health, Boston, Mass., Sept., 1922. Monsanto Chemloal Company, Plastlos Division, Confidential Report^ on Aroclor Vapor in Air From Paints, Deo., 1952, (no report number assigned). Elkins, Hervey B., "The Chemistry of Industrial Toxicology," John Wiley A Sons, New York, 1950, page 149. Us ;RIflPN,TAfr WPRK; The apparatus and operating procedure are described in the Appendix to this report. A description of the various sampling positions together with a sketch of the Aroclor plant floor plan may also be found in the Appendix. A. Experimental Data: TABLE I AROCLOR VAPOR CONCENTRATION IN AE_ Test F osition Concentration. BKt/PW.P. No. No. Chlorine Aroclor Remarks 11 5 0.32 "5713 Still in operation. 13 4 0.55 0.92 Still open. 14 5 0.52 0.87 Still open. 15 e-s 1.5 2.5 Filtering at 125C. 16 6-N 1.2 2.0 Filtering at 125*C. 18 5 0.22 0.36 Still in operation. 19 4 0.91 1.5 Still open. 20 4 0.75 1.2 Still charged and started 21 4 0.53 0.88 Still in operation. 8 ___ __________ -Aii_______ Drumming 1260 at 150*C. MONS 058950 3- jwm. n AROCIOR VAPOR CONCENTRATION IM AIR AROCLOR 1842 AND 1254 Test Position Concentration. Mg. /cu.m. Remarks NSU 5 6714^ Aroclor 0.33 Still open. 29 4 1.5 3.6 Still operating. 30 5 1.5 3.6 Still operating. 31 6-S 2.2 5.3 Press not operating and cold. 1242 In No. 2 B.T. at 110C. 25 5 0.41 0.76 Still operating. 27 5 0.50 0.92 Still operating. Note All tests on 1242 except 25 and 27 whioh were 1254. TABUS III AROCLOR VAPOR CONCEN-TRATION IN MISCELLANEOUS Test Position Concentration, mg./cu.m. Remarks No. No. Chlorine Aroolor _ 17 9 0.21 - Atmosphere blank, north of building. 23 9 0.32 - Atmosphere blank, north of building. 22 7 1.1 2.2 At operators' desk. 24 10 0.68 1.4 At steam recorder, north end of room. 12 Reagent blank 0.006 mg. Cl" In washings. 26 Reagent blank 0.007 mg. Cl~ In washings. b. ykaUY? Rgffwltff; Tests!numbers 1 through 9 were discarded. These runs were used for familiarization and establishing a satisfactory analytical procedure. C. precision and Accuracy; The method used in these determinations has been claimed to have oyer-all acouraoy of within 3% to 5# (see Millhiser, under. References). Y. DISCUSSION In Table I the most severe concentrations were encountered during three different operations on Aroolor 1260, charging the still, filtering, and dravlng out the hot Aroclor into drums. These three operations constitute the greatest ex posure to whioh the operator is normally subjected, plus the HONS 050951 -4- exposure at the desk where the oonoentration was fairly high aa seen in Table III. The drumming operation is the most severe of these since the concentration is highest and the time to which the operator is exposed to this concentration is usually in the order of 3 to 6 hours as compared to about 30 minutes for any of the other operations. The Aroclor vapor concentrations during the distillation operation varies from about 0.5 to 1 mg. per ou. m. The Aroclor vapor concentrations were calculated by assuming 60% ohlorine in the vapors. Actually the ohlorlne content of the vapors is probably lower than 60% since the lower boiling (and therefore lower ohlorlnated) components of the Aroclor are vaporised more readily than are the higher ohlorlnated components. This assumption then makes the values for the Aroolor vapor concentrations minimum values, slnoe a lower ohl cjrine oontent would give higher values for the ohlorine containing material. This same fact applies to Table II. In Table II the effect of the degree of chlorination (and therefore of boiling point) is indicated by the high concen trations found during 1848 operations. The oonoentration in test No. 10 was low, but the still had been shut down for about 7 hours when this test was made. It is noteworthy that the high concentration found in test No. 31 was during the earih treatment of a batoh of Aroclor 1848, but not during ' a filtration. The Intake to the sampling apparatus was about 8 ft. from the closed hatch of the tank in which the Aroclor was being treated at 110*0. There was a gentle draft through the room In the direction from the operating equipment toward the sampling apparatus. The Aroolor vapor concentration under these conditions was extremely high. Also, the concentrations in tests 89 and 30 were quite high in comparison to that found under the same conditions for 1860. These tests were made on the upwind side of the Aroclor treating tank. However, tests 85 and 87 on Aroolor 1854 under very similar conditions showed muon lower vapor concentrations. Further tests are required to determine whether the high vapor concentration encountered during these tests on 1848 are usual, or whether the ohlorine absorbed in the apparatus might have been from another source. Table III gives some miscellaneous tests and blank determina tions. Testg 88 and 84 show presence of considerable concen trations of roolor at points in the room relatively remote from any of the operating equipment. The operators desk is located at the head of an open stairway and quite possibly is exposed "to muoh chlorine bearing material blown up the stairway by the draft through the building. The Aroclor vapor concentra tion on these two tests was estimated by assuming 50% chlorine in the vapors. Blank determinations were made on the reagents and on the atmos phere outside the Aroclor plant. These values are tabulated in Table III. HQNS 058952 - 5- From these data it may be seen that the Aroclor vapor concen tration in the plant varies from about 0.5 to 1 mg. per ou. me ter [at the minimum up to about 5 mg. per cu. meter under the most severe conditions. No average concentration or average dally exposure of the operator have been developed from the data so far. Springfield has reported Aroclor concentrations from about 1 to 5 mg. per ou. aieter from paints containing Aroclor. It hardly seems reasonable that eonoentrations vithln this range could! be reached under the relatively mild conditions encountered, when {the concentrations found in the plant are ordinarily within this bulge even under extreme conditions. It is therefore recommended that a sample of the paint in question be secured and tests made in a room painted with it. It should be pointed out that although the Aroclor vapor con centration in the plant is seldom below the 0.5 to 1 mg./ou. meter level which is the maximum allowable concentration accord ing to Elkins (see References), the exposure to whloh the opera tor is subjected varies greatly. This exposure depends upon the amount of time actually spent in the Aroclor plant, the operation being performed by the operator, and the Aroclor vapor concentration present at that particular time. All of these factors depend themselves upon several other variable conditions, making the establishing of an average exposure eatremely difficult if not Impossible. No apparent ill effects have been noted from this exposure over a period of several years!. However, the highest concentrations were almost un bearably Irritating to the nose, throat, and eyes. Elkins has *[ade these same observations in studies in plants using Arooljor. IONS: 1. The Aroolor vapor concentration in the plant is almost never below the 0.5 to 1 mg. per ou. meter level, and often reaches about 5 mg. per ou. meter in some locations. 2. The concentrations reported by Springfield of 1 to 5 mg. per ou. meter from paint containing Aroolor hardly seem treasonable considering the concentrations found in the plant. 3. No average daily exposure may be developed from these ata. RECOMMENDATIONS; !t is recommended that sampling of the air in the Aroclor lant be continued until more complete data are obtained. SONS 058953 - 6- 2. It is recommended that a sample of the Aroolor-contalnling paint in question he secured, and that a room he pointed with It. Tests may then he made to determine tpo Aroclor vapor oonoentratlon In the room resulting from use of thlB paint. VCM 6-22-53 H. B. Richards, Jr. t ( MONS 058954 1 -7- SAMPLING POSITIONS Position Description_________ ___________ No. 1 still, simulating position of operator's head dur ing charging operations. 54" from floor on west side of still about 18" from charging hole. No. 1 reoeiver, at sight glass, simulating position of operator's head. 54" from floor and 12" vest of sight glass. 3. No. 1 filter press; N - northslde, S - southside. 54" from floor and 15" from edge of press when on south side or 9" from edge of press when on north side. Northside looatlon simulates operator's head position when redressing the filter press. No. 2 still, same as position 1 above. No. 2 reoeiver, same as position 2 above. No. 2 filter press, same as position 3 above. At operator's desk, 54n from floor and 8" beyond front edge of desk to simulate position of operator's head . when writing at desk. 8 At scales for drumming Aroolor. 54" from floor and 14" from Aroolor outlet. Opposite side of drum from . operator. I 9. Blank determinations as desoribed. 10 Miscellaneous positions, as desoribed. ( i HONS 058955 Run No. - 12 - DATA SHEET - AROCLOR VAPOR DETECTION Data: Bar. Praia., gang. Bg. Looetion of intake: Rato of afi mpllng, 1pm.: Amftlent tiimp. at in taka, *C. Ganoral Riimarka: Duration of lampling, min.: Total toI, of aample, liters: Analysis Ret vt. of vaahinga, gm.: Cl" eone. in washings, ppm.: Total Cl" in aample, mg.: Total Cl" in bleak, mg.: Cl oono. in air* mg./ou. m.: Aroolor oono. in air, mg./ou. m.: HONS 058956 y