Document Yjg5b2MNL0ko5G3B8z4J9wY3N
94
CHAPTER 4
1949 Guide -
Fluid Flow;
95
, FLOW. MEASUREMENT BY PITOT TUBE
There remains one other head type meter useful in ventilating, work,
the Pitot tube, named for the Frenchman who discovered the principle;
The Pitot tube is essentially a bent tube with its open end pointed up
stream, combined with another tube with its end pointed crosswise'to the
flow or downstream, or connected to openings crosswise to the flow. Used
with flowing liquid, the liquid will rise in each tube, but higher in the one
pointed upstream. Used with a flowing gas, and the two tubes connected
by. a U-tube containing water, the liquid level in the U-tube will be dis
placed, with the lower level on the side connected to the tube pointed up
stream. The tube directed upstream receives the impact pressure, which
r A.
,,rotaiM while the tube directed
Fio. 16. Relation op Nozzle Dischabge Coefficient, C, fob 2-Inch Pipe, to Diameter Ratio and. Reynolds Number
,, = A/(P'Y( k \ (l ~ {PtM r \Pi/ \k -- 1/ \ 1 - pz/pi
/ \1 -- ^(p/pi)!,v
(71)
This formula is plotted for fc = 1.40 .(air and other diatomic gases) and 1.30 (steam, carbon dioxide, natural gas) in Figs. 19 and 20, respectively.
3038
035.------------------------------------------------------------------
0.2 03
@04 05 0.6 OIAMETER RATIO
Fib. 18. Relation of Nozzle Discharge Coefficient, C, fob 10-inch Pipe, to Diameter Ratio and Reynolds Number .
crosswise receives only the static pressure; the difference between the two, as read on the separate tubes or on the U-tube is, of course, the kinetic
pressure. The velocity is expressed as
V =. a/Vr
(72)
Application of Equation 60 serves to make the formula general, assum
ing that water is used in the manometer connecting the two tubes. Using
this equation, and multiplying by 60 to convert feet per second to feet per
minute,
__
F- = 1096.5 /f/--
(73)
in which Vm is the rate of flow in feet per minute.