Document Yjd0LVYER19RboJm0mjx2RyeK
ID - ATC. D
CM JAMES E. HINES INGOT CASTING DIVISION ALCOA TECHNICAL CENTER - B
*2543!*
TC MEMORANDUM
1979-11-08
DATA LETTER
RE: ASBESTOS-FREE MOLTEN ALUMINUM BACKUP INSULATIONS
Summary
As part of Pittsburgh Mechanical Engineering Division--Furnace Section's and AL Ingot Casting Division's program to better design and construct furnaces and metal transfer equipment, a study was made to find acceptable asbestos-free insulating backup materials to refractories in contact with molten aluminum. Since each application must be considered individually as to the proper amount and type of insulation, this report points out the advantages and limitations of nine commercially available products.
Introduction
Refractory insulating materials offer significant advantages in the construction and operation of furnaces and refractory-lined vessels. Proper selection and application of insulation result in important savings of fuel, time, space and weight. In addition, insulation helps maintain close temperature control and contributes to more comfortable working conditions for operators.
Savings of fuel is one of the most important reasons for insulatingHeat flows through a wall or roof from an inner hot face to the outer cold face where it is dissipated and lost by radiation and convection. The amount of heat lost often constitutes a consider able portion of the total heat input required to maintain the desired operating temperature. Such losses would be greatly minimized by building the walls partly or entirely out of hightemperature insulation, either as backing to denser refractories, or when conditions permit, as an inner lining exposed directly to furnace atmospheres.
When desirable, the use of insulation also allows economy of space, weight and time. If used in place of part of an existing dense refractory wall insulation, it may permit thinner walls and the weight of the refractory structure could be significantly reduced. This would permit both a lighter foundation and a lighter furnace superstructure. At a given rate of heat input with available burner capacity, the time required to bring a cold refractory unit to operating temperature depends on the heating capacity of the refractory lining and upon the heat penetrating it. Through the use of insulation, the heat storage capacity is substantially reduced and the time required to bring the unit to temperature could be considerably decreased.
ATC 0034282
Memorandum 1979-11-08 Page 2
When selecting high-temperature insulation, many factors must be considered. One determining factor when insulation is used as a backing for a more refractory lining material is the interface temperature. The insulation obviously must be chosen such that it is refractory enough at the interface to withstand the temperature. In addition, one must consider thermal conductivity, weight, and heat capacity of the working refractory as well as destructive factors such as duration of heating, nature of fuel, refractory expansion and growth, and for lower walls, molten metal attack. When choosing an insulation for a melting or holding furnace which operates semicontinuously, high heat storage in the refractories is a definite benefit because of its cushioning effect against excessive fluctuations in temperature. The best construction for these furnaces is with composite walls and roof, consisting of dense refractories backed with compressible insulation. With a high furnace temperature and a high degree insulation, however, the mean temperature may become higher than that which the refrac tory can withstand. Hence, adding insulation may result in needing a material with higher refractoriness and requiring redesign to reduce deformation. Therefore, heat savings and other benefits of insulation must be carefully balanced against the possible increased costs associated with more rapid refractory degradation or in upgrading the working lining to high quality refractories. If this type of problem is approached in a systematic manner through computerized calculations and selection of proper materials, a refractory system can be designed which will give optimum heat savings and service life.
Insulation Materials
Listed below are the asbestos-free insulations materials examined and a brief description of each:
Eagle-Picher PV Supertemp block is composed of mineral wood fibers with specially prepared inorganic binders which has been one of Alcoa's recommended backup insulations for years. Temperature limit is 1040C (1900F).
Keene Mono-Block, also a mineral wool insulation, has fibers which
have been specially interlocked to form a lightweight and
rigid, yet resilient block. Temperature like PV Supertemp is
1040C (1900F).
`
Keene Delta-T is a felted, spun ceramic clay fibers bonded with inorganic binders. Temperature limitation is higher than mineral wool at 1260C (2300F).
Rim Products 410-03, a ceramic fiber product, is made by bonding alumina-silica fibers with high purity alumina. Temperature rating is 1300C (2372F). This insulation was reported to be nonwetting to molten metal, making this insulation particularly attractive.
ATC 0034283
Memorandum 1979-11-08 Page 3
International Vermiculite IV-19 block insulation is manufactured from vermiculite granules and high-temperature bonding inorganics; like the mineral wool insulations, it is good to 1037C (1900F).
International Vermiculite IV-20 block insulation is asbestos-free as are all of these other insulations. IV-20 consists of diatomaceous silica with a hydraulic binder for service to 1093C (2000F).
Johns-Manville Superex products have been used in combination with Eagle-Picher's PV Supertemp for reverberatory furnaces. A combination of silica, lime, clay and fibers make up these products. Superex 2000, a high-density, low-calcium oxide content block, was designed for low shrinkage and top performance up to 1100C (2000F). Superex 1600, on the other hand, has a high-calcium oxide content and lower density than Superex 2000. This formulation gives better strength and insulating properties for situations where temperatures do not exceed 870C (1600F).
Skarool Skamolex PM-10 (formerly Skamolex GX 1000) is also a white calcium-silicate material. This product is distributed by Dolomite Brick Corp. in the United States but manufactured in Denmark.
See attached manufacturer sheets for more details.
In Table I are the chemical analysis and X-ray diffraction data collected for the nine products studied. The purest material is the Rim 410-03 which contains the highest alumina content and is essentially all amorphous. Three insulations--PV Supertemp, Mono-Block, and Delta-T--are montmorillonite (CaMgSiO.) based. Delta-T has the lowest impurities, whereas Fe_03, MgO^and alkali are high for both PV Sumpertemp and Mono-Block. IV-19, as characterized as X-ray diffraction, is largely comprised of talc and silica. IV-20, on the other hauid, is identified as a diatomaceous earth composition which has silica and calcite. Cristobalite and alpha quartz forms of silica make up Superex 2000. Superex 1600 and Skamolex PM-10 both are calcium-silicate hydrates.
Evaluation and Test Procedure
Outside of the compressibility testing, all physical property data were determined using ASTM methods. Bulk Density, linear change, and loss on ignition were all examined. Compression tests were accomplished with a Dillon dynameter. Square samples measuring 50.8 mm (2 inches) were aligned in the Dillon machine and compressed initially to 90% of its original height. (Fibrous materials were positioned so their fibers were perpendicular to the pressing
ATC 0034284
Memorandum 1979-11-08 Page 4
direction.) The load was then recorded. Compression measurements were continued for every 10% deformation up to a reduction of 40%. Any fracture or unusual behavior was noted.
Corrosion resistance to molten aluminum was determined by Alcoa's modified B-Immersion test. Simply, this test consists of preheating the sample to 540C (1000F), then immersing three-fourths of its length into 7075 alloy at 760C (1400F) for 24 hours. After being cleaned, the percent sample weight retained is recorded. If possible and results are warranted, a second cycle is performed. Again, precent sample weight retained is determined.
Results
Please refer to Table II for physical property data. Maximum recommended service temperatures are recorded first. As seen, the higher the temperature the fewer materials are available. The major drop-off points were at 875C (1603F), 980C (1800F), and 1320C (2400F). Rim 410-03 had the highest rating at 1300C (2372F); Delta-T followed at 1275C (2300F). All the other insulations are suggested for less than 1000C (1832F) , except Superex 1600 which is only rated at 870C (1600F).
Other properties which determine allowable exposure temperatures include linear firing shrinkages and loss on ignition. For these measurements, 2.5 X 2.5 X 15-cm (1 X 1 X 6-in.) samples were exposed to temperatures of 540C (1000F) and 1100C (2000F) after which they were measured and weighed. Photographs of some of the.specimens after exposure are given in Figures 1-8. At 540C (1000F) only slight dimensional changes were apparent, but loss on ignitions were high for IV-19, Superex 2000, and Skamolex PM-10. (Loss on ignition measurements give an indication of the weight of chemically bonded water and organic materials.) Therefore, these three materials show structural hydrate changes even at this low temperature. At a temperature of 1100C (2000F), very few insulations retain their structural integrity. Only Rim 410-03 and Delta-T materials remain relatively unaffected.
Crushing strengths were performed up to a deformation percentage of 60%. For most backup insulations the material should be rigid enough to install but have a crushing strength to meet refractory expansion without .overstressing and deforming the furnace outside shell. Eagle-Pichers's PV Supertemp has been the perferred material in melting and holding furnace construction. It compresses steadily up to 50% before its strength suddenly doubles. At no time during the testing did the sample fracture. Other insulations (MonoBlock, Delta-T, and Rim 410-03) behaved similarly. Rim 410-03, although exhibiting an initial lower strength, more closely resembles the compressibility of PV Supertemp than any other insulation. IV-19, IV-20, and Skamolex PM-10 all fractured at
ATC 0034285
Memorandum 1979-11-08 Page 5
approximately 34.5 MPa (5,000 psi). The Superex products, although not showing a brittle fracture, had exceedingly high strenghs up to 345.0 MPa (50,000 psi) after only 40% compression, the highest of all insulations.
The apparent thermal conductivity of mass insulations is a combination of the following heat transfer mechanisms: thermal conductivity of air, thermal conductivity of the solid components of the insulating structure, the convective heat transfer within the pore structure, the radiation heat transfer within the structure, and the interactions of these mechanisms. The thermal conductivity term itself refers to an intrinsic property of a homogeneous material, but because of these many heat transfer mechanisms it is subject to much theorectical questioning when referring to insulations. For comparison purposes however, the manufacturer's thermal data are given. As shown, the thermal conductivities of all the insulations evaluated are nearly the same. The greatest difference is between IV-20 and PV Supertemp, 0.13 W/m-K (0.89 Btu-in/h*ftr F) compared to 0.10 W/m-K (0.69 Btu-in/h*ft F), respectively. In this regard, the choice of which insulation to use will be dependent upon other factors discussed.
In many circumstances, molten aluminum may come in contact with the insulation. Molten metal may penetrate to the insulation through lower wall refractories which crack during installation, dryout or other reasons. To evaluate those conditions, the modified B-Immersion test was used. Results are found in Table III and Figures 1-8. Although all the insulations showed good to excellent to molten aluminum resistance as indicated by the high weight retention, the mineral wool products, PV Supertemp and Mono-Block, did shrink and bowed excessively upon metal contact. In actual service conditions, this type of behavior may leave gaps in the lining allowing further metal penetration. For fibrous products, Rim 410-03 and Delta-T, metal resistance was good; both materials remained intact even though some penetration was seen in the Delta-T. The other materials (IV-19, IV-20, Superex 2000, Superex 1600, and Skamolex PM-10) performed excellently; the metal skull retained could be easily removed.
Safety Statement
Although these materials do not contain asbestos, some are composed of free crystalline silica (see Table I for analyses). It is the uncombined silicon dioxide (SiC>2) in these insulations which may lead to lung disease. Of primary concern is silicosis, a noncancerous disease of the lungs. Silicates, although consisting of silicon and oxygen, combined with other elements in a complex molecules. With the exception of asbestos and some talcs, silicate dusts should not ordinarily cause disabling lung conditions such as produced by free silica. It is uncombined or free silica
ATC 0034286
Memorandum 1979-11-08 Page 6
however that is most important in industrial dust exposure. To detect an exposure properly, the percentage of uncombined silica must be determined by petrographic analysis, preferably by X-ray diffraction or infrared techniques.
It is generally stated that the size of the offending dust particles is of extreme importance in determining the concentration of particles that may be suspended in the air. The size of particles also determines the depth to which these particles penetrate into the lung along with the quantity that may become deposited and retained. Particulates less than 10 microns in size are potentially the most harmful. Generally, when airborne particles are larger than 10 microns, they are not of concern because they are unable to penetrate into the lung where they could be damaging. Instead they are removed and collected by the nasal passages or upper respiratory system.
Also, it has been generally stated that the duration of dust inhalation is of extreme importance. Persons who for. many years have continuously inhaled free silica dust have a great likelihood of contracting a silica-related disease. Those who only intermit tently inhale the dust have less risk of injury. In addition, those persons who smoke will increase the risk which otherwise exists.
It is important to be aware that exposure to silica dust can occur during the installation of some of these products that contain free silica as well as during tear-out and repair of facilities where these products were previously installed. It is recommended that personnel working with these insulations wear respirator and eye protection, and that the area be properly ventilated. Periodic safety monitoring of the free silica should be scheduled also.
Conclusions
1. Major insulation materials in the high temperature range are (listed in ascending order of temperature resistance):
a. Mineral. Fiber, 540 to 1040C (1000 to 1900F)~ PV Supertemp and Mono-Block-.
b. Calcium Silicate and Silica, 870 to 1100C (1600 to 2000F)--IV-19, IV-20, Superex 2000, Superex 1600, and Skamolex PM-10.
c. Ceramic Fibers Based on the Al-O,--SiO- Systems, 1100 to 1260C (2000 to 2300F)--Delta-T and Rim 410-03.
2. High compression strengths were found for IV-19, IV-20, Superex 2000, Superex 1600, and Skamolex PM-10, whereas fibrous materials (PV Supertemp, Mono-Block, Delta-T, and
ATC 0034287
Memorandum 1979-11-08 Page 7
Rim 410-03) show the least resistance to deformation or high compressibility.
3. Thermal conductivity values did not vary significantly between the insulation types examined.
4. Although exhibiting nonwettability, mineral wool insulations (PV Supertemp and Mono-Block) do shrink excessively in contact with molten aluminum. Other products (calcium silicate, silica or ceramic fiber materials) all have good-to-excellent resistance.
5. Products IV-19, IV-20, Superex 2000, Superex 1600, and Skamolex PM-10 have been identified as containing free crystal line silica. Largest contents were found in Superex 2000, IV-20 and IV-19.
Recommendations
Again, each application must be considered individually when recommending insulation. One must consider the thermal conditions imposed by service along with each particular insulation's qualities of mechanical strength, chemical compatibility, weight, compactness, heat flow resistance, and so forth. In many cases it must be recognized that local availablility and delivery will at times necessitate the use of a product in a specific class.
For ingot melting and holding furnaces, one of the most important developments by Pittsburgh Mechanical Engineering in the past year was the development of a computer program to investigate temperature profiles. On the basis of a computer study and this present work, lower furnace walls are now being backed up with 50.8 cm (2 in.) of Rim 410-03 or Delta-T insulation in place of 50.8 cm of PV Supertemp and 50.8 cm of Superex 2000. This design has established a more realistic metal freeze plane with insulations that are both compressible and molten metal resistant. This construction should prevent frequency of furnace bleedouts and conserve energy. Other ingot applications such as troughing, filter units, etc., are being reviewed, and better materials and designs are being plant tried. With proper design and material selection, improved service life and more comfortable working conditions should be realized.
Finally, in handling some of these products studied, particularly Superex 2000 and IV-20, special precautions must be taken to minimize dusting. Without adequate ventilation and respirators, a safety problem does exist.
ATC 0034288
Memorandum 1979-11-08 Page 8
JEH:bls Attachments - 18 cc: ID - ATC, D G. L. Baker - Pittsburgh 3 WPH M. J. Caprio - Pittsburgh 3 WPH C. J. Cox - Pittsburgh 3 WPH C. F. Hartley - Pittsburgh 3 WPH R. C. Holtz - Pittsburgh 3 WPH W. A. Keith - Pittsburgh 3 WPH A. J. Magnussen - Pittsburgh 3 WPH J. W. Mclntee - Pittsburgh 3 WPH E. L. Rooy/H. G. Reavis - Pittsburgh 23 H. G. Sakoian - Pittsburgh 7 A. J. Sartschev - Pittsburgh 3 WPH D. L. Schaffer - Pittsburgh 23 L. D. Tannis - Davenport Wks. J. Damiano - ATC, C M. B. Thomas/D. J. St. Jacques, Jr. - ATC, C M. B. Dell - ATC, C R. K. Dawless/F. N. Smith - AL, NK-44 S. K. Das/P. A. Fyala/A. L. LaCamera - AL, NK-44 M. J. McMonigle - AL, NK-44 R. E. Miller/V. L. Hammersmith - ATC, B R. G. LaBar/R. E. Spear/File: 10.160 - ATC, B
ATC 0034289
O
*(304
O> 44
cr C9
c
un3
cr
CX a
CO tM ct < c o 44 o ChO
H Q >* tuo 1 K
03
3cr
c
4-4 c o
cx H H
c3 CeO
>
e to
k
4J
41 c
c o H
44
HHo rl t-
cO
U o 4e4
o *-M rt
4E-4 c o
m 3
eoE
It O 4&J
EO
00
Xcx n
CM o
CO
Hm
CEO
y"V 4M4
U
a
H 3cr
44 Ny
Xc
CM &
Xo
Sy CM
or-t o*M
o*3 C1O
00 e
CO
00 o
X
a v
o
o
CO
O
OH
u
y--*,
H
CeO
4J w
3
y-> cr
44
Hr
c cx
C rM 3
x4o4 CD
a CM
O XChL
oo
4 E
wo
CO 1
CM 8
a
o
H E
c
cn to H
c
^y
CM
o CO
3
CO 1
XO
e
cx p
Ho
6 CO
E
* y">
o
4J
c rH
H
X 4o-1
ca c
*
o
Wi c
voy
ac
c
CM 3
oH
CO CEO
4-4
X*
o
XEi
X^
4OJ 4NJ
^u
*
O
cm
c3r
X
<r
J=
NO cx
oNO -*
M N-'
COCM CM
y~* O
X H
O CO
^*n e1
'OH
e
x cx H %0-y
CM O CO I O H CEO >
CM
X o
r>H OnO H CO NO o u
c
o
00 o
E
p4 X > -5
o *610
H
3 > to X
3 > X
to 00
00 4
MI
MANUFACTURER'S DATA--
ANALYSES OF ASBESTOS-FREE INSULATIONS
ou X
K
m
n
M|
OH
>H I
C <
o o
UVCi M
CO *3
*3I w"i
CM
I^
I CM o
On H
CM
CIO CM
CM
CO
CM '*3*
*3
O
CO
ot>
CO
o fi-oe
n<o
CO
O HCM
rs
H 1
<
CCMO
H
I I
-3
W3O
CM
On
CO
CO
t I
CO
O 1ON^
On
CO
4
w3 3o
o
ou
cx
3
c *3
xa <C0
|4
o. e
Xo **M On
4J Uo
a
H 00
3 CO
Ct) >cx
Ai U Ho n i co c o sr x
H
1
c
4aJ H
i-2 a
4-4, tl 3 *o O W CO CX of FO
-M X *3
44
C o
H
<4r4( O3
CE
u U On
-*
4J c
>
>(
M
4J cO H v< 3 4J Cl H 1C4 EU OCM 4- > | c> MM
CO CM
oo
O o o CM o o
NO CO
o
NO o
05
CrMr
co
oCO so CM o
gr-
*O3N
r-. 3
<
H
HO
H O
>O
C CM
X1 x
w
Xc
cx
nO t3o
H
-c o
o
>o
C -M
Xx
C10. |4
xC
cx
"O> C3O
o H X(X X HH oo EE AC AC CO CO
CO
O1N On H m c X Ct) *->
CABLE I
r540C <lCOO r>
UOOC tio o o 'r)
-3.6 -2.5
-1.3 -1.7 -2.6 -2.4
-0.64 -2.6
-8.0 -11.6
-3.4 -6.1
-5.4 -8.9
-6.2 -11.6
MOLTEN ALUMINUM CORROSION RESISTANT INSULATIONS
0>
H <D CQ rH 4J CL 01
cn
o o
H
01
aa
0)
E
Q CO
H
r rH
cq x
CL
o rH
>
O rH
Co
Cl H
X <u
en u
O L4
Xo
E
CO cn
o
V2 > CL
O
eo
01 *o
01
>o E
01
c o
e
o
c o
CO
AJ 4-1
Li
o
Li *H
H
0)
4->
G
0)
M
C 4-> 3 01 HG
0) 9
>o
O
E *0
cs H 00
O rH
cn
>> Li rH O H X
01
> o E
o
4J
4-)
03 Lt J
4J
03 Li 4J
u
C3 Li 4->
|i
o
o
X oi cn cl
0) 0)
Li 5 O
0) 4-1 O
(0 4J
W rt
CO LH a
01 L4
>, 01
CO c m 01
01 C 01
01
c
o
^ 0)
rH *H
*0 4J
SsX
H *d
4LJi cn 01 01
*0)
rH
rH
Eo
tn rH
H
0)
CL CL
CL
01 0) o
CO 4-1 X *H
<0 c
<0 CO
e01 o(0
3 03 .X
03 03
Li rH rH
01 x X
rH
X
*-H 0)
0)
.X
CL Li 4J
CO Li 01
01
> H a
*H
cn 03
f--1 a
rH c
H
rH >
H
H
rH H
c6l aC>
C0 *rl CO rH
CO 3 4J Li
0) X Xa
co E
4J O 01 Li
X *
CO 0) 4J
0) o xx
co
*J 0)
X
0) 4J 0)
X
>
o X
>
o X
> O
X
60 G H
4-
p40
u Li OO oO a CL
4-1 4-1
4J
4J
4J
4J
Gc c c c c
O U
01 rH
01 iH
01 *H
0) rH
01 H
01 rH
rH rH
H
1-4
H
rH
>N u o> >
Sn o Mo 0) o >o
a ai oo
OX
ow
01
a X w
0)
o X
0)
O X w
01 ' 01 oO XX w (=3
*0
0)
4J G X *H 60 CQ
H 4J
01 0)
XX
LO
i-H
o
H
o
h>
cn
CS
00
cn
ON
cs
OH
rH OH
o
OH
OH
r*^ co
NO CQ
rCO
^Photos not shown due to fr a g ile n a tu re .
Li
u01
uo
01 4-1
H H
3 rH rH
a4-1 3 3
oU
CO <vH H
lh E E
3 L4 M
C 01 01
CO JE
>>
4:
01 0) O
rH rH rH 4: f-H rH
*o CL H
CO
<0
cd O rH O rH
1
c
5 xco 4LJi aHrH x x xcd
H
3 a>Li O C01
4J
to X
E 01
i
01 CL CL 1
CO rH 60
> CO CL W
o o rH CQ 1 0)
C 0) O 0) X x:
H i <0 01
4J C rH 01 0) 01
Q^
4J
O 3 *o o cn Li
O CL 1
OE rH H <r x
c
o H 4-1
CO
c
Oh Li *H 01
1 4-1
>c WM
c o UH
CO C O Li CS 0J 1 4J
>M Mc
O -H O> cs c
X 0) 1 Li CO
0J c
CL X 3O w *n
o "H NO > rH C
CO
0 1 li cn 01 3 ax 3O co *n
X a
X 01 rH o
E Q .X
CO
ATC 0034292
TABLE I I I
EAGLE RICHER
J. P. AUSTIN
figure 1
ATC 0034293
MONO - BLOCK KEENE CORPORATION
FIGURE 2 ATC 0034294
DELTA T KEENE CORPORATION
ATC 0034295
r
[' TYPE 410-03 BOARD.
RIM PRODUCTS CORPORATION ^MODIFIED B IMMERSION!
2 CYCLES^v^l
' . *' * ^ * 4
ATC 0034296
FIGURE 4
IV 19 INTERNATIONAL
VERMICULITE CO.
r- - v
_ /
FIGURE 5
ATC 0034297
TT
i IV_20 INTERNATIONAL VERMICULITE CO.
ATC 0034298
iSUPEREX 2000
i JOHNS MANVILLE Co.
1 1
4
ATC 0034299
FIGURE 8
ATC 0034300
TYPE: Block TEMPERATURE: to 1900F
PsSCTtptlOTi: Eagle-Picher "PV" Supertemp
Block is composed of high temperature mineral fibers bonded with specially prepared binders to form a block insulation having optimum properties during both installation and service. Fibers are oriented to insure maximum strength and thermal efficiency. The blocks are "wet-sawed" by a patented process to provide precise dimensional tolerances and freedom from dust.
" pv"
SUPERTEMP BLOCK
Uses: Recommended for direct application or
refractory back-up insulation in petroleum and process
units, power generation equipment, ovens, furnaces,
kilns and other related equipment requiring an
insulation that is economical, efficient and
dimensionally stable.
/' '
-
Durability; Strong yet resilient, processed to maintain structural integrity during field application.
Absorption: Allows placement of castable refractories in direct contact with the block without degradation. -
lnstallatiomCai) be impaled on pins without predrilling. Easily field fabricated with knife or saw. Standard sizes up to 24" x 36" permit rapid installation.
Physical Properties:
Service Temperature
.......... to 1900F.
Density............................. 16-181bs./cu. ft.
Moisture Absorption.................................. NU Fixe Resistance .........................Incombustible
Corrosion............ Does not cause or accelerate
Physical Propertied (contid):
Linear Shrinkage
at 1600F............................................ 2.0% 1800F............................................ 2.2%
Modulus of Rupture............... 40.0 Ibs./sq. in. Compressive Strength.............2,600 lbs./sq. ft.
at 10% Deformation
Mean Temperature
F.
200 400 600 800 1000
"K" (Btu-in./hr./ sq.ft./0 F.)
0.28 0JJS 0.49 0.59 0.69
ATC 0034301
PCgtf 1.1.2
r --\, "i-V-.
ITS '
tan ji
"PV" SUPERTEMP BLOCK
Standard Sizes;
-.
Thickness: Width: Length:
1" to 414" in 14" increments 6", 12", 18" and 24" 18" and 36"
Special sizes and shapes are available and are quoted on request
Heat Loss Chart
Applicable Specifications:
Commercial Standard CS-117 ASTM C612-67T, Class D
Federal HH-1-55S, Form A. Class 5
Packaging:
6 X 18
12 X 18 6 X 36 12 X 36 18 X 36 24 X 36
Board Feet per Carton
1" 114" 2" 214" 3" 314" 4" 414"
48 45 48 45 45 42
48 40.5
48 45 48 45 45 42
48 40.5
48 45 48 45 45 42
48 40.5
48 45 48 45 45 42
48 40.5
54 54 54 45 54 47.25 54 40.5
48 54 48 45 54 42
48 54
i
j
EACIr:
Since ISO
ATC 0034302
Manufactured by
d S'! EAGLE-PI CHER INDUSTRIES, INC.
Fibers Department
\'3*+ American Building
Cincinnati, Ohio 45202
id
~ T : 0 ;
MONO-BLOCK
Mineral Wool Insulation- For Service to 1900 F-Asbestos Free
DESCRIPTION:
MONO-BLOCK is composed of spun mineral fibers and inorganic binders especially formulated for resistance to high temperatures. A patented process interlocks the long mineral fibers to form a lightweight and rigid, yet resilient block which is shaped and fitted.
TYPICAL USES:
Heat Treating Ovens Boilers Incinerators Chemical Treating Tanks Refinery Equipment Ducts and Breechings Feed Water Heaters Wind Tunnels' Jet Silencers' Fan Housings'
'Acoustical Applications
PHYSICAL PROPERTIES:
Density-- 12 Ibs./cu. ft. miniumum Compressive Strength -- 10 lbs./
sq. in. @ 10% deformation Flexural Strength -- 40 Ibs./sq. in. Linear Shrinkage after heating 24 hrs. at1900*F
Soaking Heat -- Less than 5% Single Face -- Less than 5%
THERMAL CONDUCTIVITY:
Mean Temp. *F
200 400 600 800 1000 1200
K .36 .42 .51 .62 .75 .90
STANDARD SIZES AVAILABLE:
Length -- 18. 36 inches Width -- 6.12, 24 inches Thickness -- 1-4 inches in Vi inch
increments
SPECIFICATION COMPLIANCE:
Military: MIL-I-24244A* Federal: HH-l-558BFormACIass5 ASTM: C612-70Class5 "Indicate on order when specification compliance is required.
TMCXNOft V NOT^ACC -- COlfrSACC TtWP. OtAJrr
IS73 j;
FEATURES:
Easy to Apply -- Easily cut with a knife. Conforms to slight curvatures or projections such as rivet heads, pro viding a snug fit without cracking or breaking. Can be impaled over welded studs without predrilling holes.
High Strength -- Strong because of long mineral fibers and unique manu facturing process which uses inorganic binders. This extra strength guards against breakage loss.
Low Chloride/Moisture Resistant -- Acceptable for use on austenitic stain less steel.
Effective Acoustical Properties -- High sound absorption efficiency makes this product applicable where acoustical treatment is required at elevated temperatures.
CO'-F-OrtATlOK
INSULATION
:ao: fUlPOHD STPEE7. KALAMAZOO. MICHIGAN 4SGU3
TiCirtON
30-122* TfcLEX
. TEUPCIUTUM OF NOT FAC* -- OCOAEE* FAMACNMC/T
ATC 0034303
006> uc<Sip'w ooicuicirx imjiS PJO|lBd ECf'l
uoisjAjQ spnpojd 6uip|ing NOIlVbOdUOO
3N33M
.2 4
Therm al Conductivity Mean Temp. F 200 400 600 800 1000 1200 1400 1600
:*o
-TO'm'3*"-
'TO -
:to
cb'"T"
IT) CO CM CM ^ f t* ^ r-
C / --to3 C-
o "O ,ZZ'.
X
- -<J). '
m-O 2 S,
^ CP V 11 > O CM f*
W
S
O
`V- ~
u. o o
`
00^ "O
-- 2 o 2
o
-
o CM
.. -
< worn--2
0)
A" vi^r:
u.
o#
. " ' . : w '2';
3
H
CD
X
O -C
o
O
-. ^ vx . -E : . ^ . ^.
C *. o
c
co OT
SOp'
<n TJ
^>*
*D. 2 XO
a c
xo 2 xO |p
<
cd E o fc
15 -o=
E
e|3
<
"
--
W
ao
J22CO tQEJ
O u.
-2
.--T-tOr
h
2
J, a
,
5*^W.*'W^v0 '*v5f:
. o. O)
- Eo
c
E
I
s: u c
> r* "
>
>"
w N
W
ON
t C m w
S 2 c i " I
c ;.< '
CL CO
.o .-J. .
<0 O
15 v:^
O
9 mm
IH o o
a
*\0 V.-i:
*\tt-J.2V. *o" frT -->
,*. .C *t?
?S
.
`v -- O-x o * ]*< to co to
COK
. `-o o ~ o
.Nv'f*'O-o oO oO
` ~\*0 TT CM W CO
co
OWN
O CO to o
CM CM
:a>
to o f~ o O^
*T
15
a .
u O
oc
":gl ao
s = O)
E =" E c
3 o
o
S
z>
U. o o oo o CO
cm
* * O. CL Q.
0.c00c 0c TO TO T3 To (>0 Eou Eok.Eou
> * *0*0*0
.? in in m
<)()
O)
*C 1L U.
oo
CO
O CO
O
o CO
W '
w
TO @@)
ATC 0034304
# Hi-ALUMINA
CERAMIC FIBER INSULATION Contains No Asbestos
------- ----- \
Type AH-50 For 1500C {2732F)
Type AH-30 For 1400C (2552 F)
Type 410
For 1300C (2372F)
_________
J
Hi-ALLMINA ceramic fiber products are made by bonding alumina-silica fibers with high purity alumina. No starch, silica, clays or asbestos are used. As a result, lowdensity insulating products are obtained with high alumina contents. These Hi-ALUMINA products outperform conventional silicabonded products.
Three products are offerred for three tem perature ranges with three markedly differ ent costs. In this way, users are able to obtain the most economical insulation for any particular temperature range.
Also available for the 3000F range are our ALL-ALUMINA products described in a separate bulletin (AA-320).
PRODUCTS AVAILABLE Type AH-50 77% A1 203 For 1500C(2732f) Type AH-30 61%A1203 For 1400C(2552F) Type 410 54% A1203 For 1300C (2372F)
All of the above products are available in the form of boards, tubes, cylinders or special shapes. The products can be varied in size, thickness, degree of hardness and surface finish.
APPLICATIONS The principal use for these products is as a rigid form of a low density, high temperature insulation. The alumina-insula tion requires 50% less insulation than conventional brick insulation. Fast heat-up. fast cool down and low heat storage make this insulation ideal because of today's energy shortage.
Among the insulation uses are furnace linings, back-up insulation, heat shielding, induction coil liners, combustion chambers, stack insulation and high temperature pipe insulation.
The non-wetting characteristics of alumina binderand alumina-silica fibers to molten metal makes these products desir able for many molten metal applications. Among these are riser sleeves, hot top linings, trough linings and tap out cones.
The low sodium content and high surface area of the alumina binder makes these products ideal catalyt supports for the flameless heater.
The low sodium content makes these products ideal for electrical heating element holders and radiant heater pads.
Other uses include burner blocks, expansion joints, kiln furniture, gaskets, peep hole plugs and seals.
rim products corporation
1605 east ayre street newport, deiaware 19804 phone (302) 995-7194
A
ATC 0034305
iro- itui > 4~\
H-too
PROPERTIES Chemical Composition A1203 (%) Si02 (%)
Density (Ibs./cu. ft.)
Modulus of rupture (psi)
Loss on Ignition (%) (Absorbed Water)
Linear shrinkage (%)* 1300C (2372F) 1400C (2552F) 1500C (2732F)
Thermal Conductivity (BTU-in./sq. ft. hr. F) 1300C (2372F) 1400C (2552F) 1500C (2732F)
Melting Point Fibers Binder
Recommended upper use temperature
Thermal shock resistance
Two-hour soak
AH-50
77 23 11 -12 60
2.3
1.2 2.0 2.5
AH-30
61 39 14-16 75
2.3
2.6 3.1 --
1.5 1.7 1.8
Above 3200F 3700F
1500C 2732F
Excellent
1.4 1.6
Above 3200F 3700F 1400C 2552F
Excellent
410
54 46 16-18 80
2.3
3.6 --
1.4 -
3200F 3700F 1300C 2372F Excellent
The above information is intended for use by persons having technical skill, at their own discretion and risk. It should not be taken as a warranty nor as a license to operate under, or recommendation to infringe anypatent. Some of the above values are averages obtained on developmental material and are subject to change. They should not be used for specifi cation purposes.
ATC 0034306
IV 19 Block Insulation
Product Data Sheet
IV-19 Block Insulation is an asbestosfree insulation, manufactured from vermiculite granules and high temperature bonding materials. It is a versatile product available in a wide range of sizes.
Because of its low conductivity, IV-19 is an economical, energy saving insulation. It exhibits minimal shrinkage at top temperature limits, and will not decompose even when exposed directly to flame at or beyond maximum service temperature.
IV-19 is an excellent back-up insulation as well as a highly efficient hot-face insulation for temperatures at or below 1900' F (1037 C). It's unique composition and hard surface helps insure strong adhesion of cement finishes, and provides superior handling qualities.
IV-19 can be manufactured with either straight or beveled edges to meet customer specifications. Standard sizes and weights are listed on the price sheet. Prices for custom size blocks will be quoted upon request
ATC 0034307
5
Product Data Sheet
IV 19 Block Insulation
Physical Properties:
p* III Q* Temperature
Xjx
1900 F 1037s C
Conductivity
0.56 "k" at 200 F (.0808 W/mK at 93 C) 0.64 "k" at 400 F (.0923 W/mK at 204 C) 0.72 "k" at 600F (.1038 W/m*K at 315.6 C) 0.80 "k" at 800 F (.1154 W/m*K at 425.7 C) 0.88 "k" at 1000 F (.1269 W/m*K at 537.8 C)
Linear Shrinkage
At 1900 F (1037 C): 2^5%
Chemical Analysis
Vermiculite, the basic
component of l\M9, is
a magnesium, aluminum,
Iron siiicae. It contains
no free oxides.
AIjO,
9.19 CaO
11.51
Si02 54.38 KjO
3.72
As Silicate
Cr}0j, TiOj
Fe2 0]
5.35 NajO, MnA 0.86
Mg 0
13.16 CombinedH2O 1.84
Shipping:
Carton
IV-19 is available In standard block thicknesses of 1" to 6* in Vz" increments with the other dimensions measuring 6" x 18". 6" x 36". 12" x 18" or 12" x 36". Special sizes available on request
Density
Cold: 20.5 Ib/ft1 (328.4 kg/m1) At 1900 F/1037 C: 19 Ib/ft* (304.4 kg/m>)
Crushing Strength
Cold: 125 PSI (.0878 kg/mm*) At 1900 F (1037 C): 51 PSI (.0359 kg /mm1)
Area of Application:
End/Sidewalls
Bn IV-19 has a wide variety B of uses in high 1 ~l temperature industrial furnaces including end
and side walls of various heating furnaces ... soaking pits, reheat furnaces, carbonizing furnaces and other annealing furnaces. IV-19 is applied as backup insulation as well as hot face material at temperatures of 1900 F (1037 C) and below, for example IV-19 could be used in duct or flue linings and cyclones.
Modulus of Rupture
Cold: 73.5 PSI (.0517 kg /mm*) At 1900 F (1037 C): 51.5 PSI (.0362 kg /mm1)
Method of Application:
Block Construction
Install, using standard C. procedures for block LasSsSsIfl construction.
ATC 0034308
6 International Vermiculite Company/ Post Office Box 66/ Girard, Illinois 62640/ Telephone 217-627-2193
18477-06
1V-20 Block Insulation
Product Data Sheet
IV-20 Block Insulation, made from diatomaceous silica with a hydraulic binder, is a superior high temperature insulation for service to 2000 F (1093 C). According to ASTM testing procedures, IV-20 exhibits extremely high resistance to breakage at 2000 F (1093 C). Long maintenance-free service and maximum operating efficiency is assured by IV-20's unique combination of low conductivity and high stability. IV-20 is also very low in sulfur and iron, making It highly resistant to attack from atmospheric
conditions and greatly reducing the possibility of product contamination.
Like other International Vermicuiite products, IV-20 is produced in a wide range of standard block sizes, available with either beveled or straight edges. This product can also be manufactured in special shapes to fit customer specifications, saving money on both installation and energy costs.
Asbestos-free
Shipping
ATC 0034309
7
Product Data Sheet
IV-20 Block Insulation
'a
Physical Properties:
p* ||1 Q* Temperature
2000 F .1093 C
Conductivity .65 "k" at400oF (.0938 W/m*K at 204.4C) .70"k"at600F (.1009 W/m-K at 315.6C) .77 "k" at 800F (.1111 W/m*K at 426.7C) .89 "k" at 1000F (.1284 W/mK at 537.8C)
Density Cold: 24.5 Ib/ft1 (392.2 kg/m1) At 2000 F (1093 C): 23.5 lb/ft* (376.4 kg/m)
Crushing Strength Cold: 176 PSl (.1237 kg/mm1) At 2000 F (1093 C): 150 PSl (.1055 kg/mm1)
Modulus of Rupture Cold: 55 PSl (.03867 kg/mm1) At 2000 F (1093 C): 90 PSl (.0633 kg/mm1)
Si02 AljOj
CaO
I Linear Shrinkage
| at 2000 F I (1093 C): 2.8%
Chemical Analysis
IV-20 is made from
diatomaceous silica with
hydraulic binder.
79.0% MgO
3.8%
3.9% FejOj
1.3%
6.8% Ignition loss 5.1%
Shipping:
Carton
IV-20 is available in standard block thicknesses of 1" to 6" in Vi" increments with the other dimensions measuring 6" x 18", 6" x 36", 12" x 18" and 12" x 36". Special sizes available on request.
Area of Application:
End or Side Walls
Spi IV-20 is primarily a side Li wall and end wall I--------------- 1 insulating material.
Whether it's used as a hot face or a backup depends upon customer requirements and the IV-20's 2000 F (1093 C) service range. The wide range of uses includes such diverse applications as, soaking pits, reheat and pusher furnaces, copper reverbatory furnaces, petroleum reactor vessels and oil fired water tube boilers.
Method of Application:
Block Construction
Install using standard procedures for block construction.
0
ATC 0034310
8 International Vermiculite Company/Post Office Box 66/ Girard, Illinois 62640/ Telephone 217-627-2193
18477-08
Johns-Manville Refractory
H3i
Products
SupsrsxTM Block Insulation
Type: Block Temp. Limit: 2000F
Description
Superex block insulation products are manufactured
from carefully selected combinations of silica, lime,
clays, and fibers for reinforcement purposes. These
products are characterized by high strength, both
cold and at elevated temperatures, and high
refractoriness. They can be used right up to their
temperature use limits -- and in some conditions
even beyond--should upset conditions occur. They
uniquely combine low thermal conductivity and high
stability at elevated temperatures to provide
efficiency of construction and thermal performance,
and long maintenance-free service. Superex Block
products contain no asbestos fibers and are not
soluble in water. Repeated wettings have no effect on Uses
this insulation. z'
Ovens Soaking Pits
Reheat Furnaces Annealing Furnaces
V. Superex products are not recommended as a furnace High Temperature
lining material exposed to combustion conditions
Mains and Flues
Heat Treating Furnaces Combustion Air Piping
unless a great deal of past experience shows the
Industrial Boilers
Bustle Pipes
product to be satisfactory in a particular application. Marine Boilers
Blast Furnace Stoves
Regenerators
Glass Lehrs
Typical Applications Superex biock is designed as a backup insulation for
Kilns Roasters
CarTops Forge Furnaces
all refractory constructions; i.e., insulating firebrick, dense fireclay brick, castables, plastic refractories
Reverberatory Furnaces
Laboratory Furnaces Cooking Equipment
and also ceramic fiber felts and blankets. All Superex
block performs well at high temperatures and
Advantages
efficient designing of a refractory system with
Exceptional Heat Resistance. Superex Block can be
Superex as the backup insulation will reduce the
used to its full temperature use limit. Its high
amount of hot face refractories required.
refractoriness also offers some insurance against
immediate failure should these temperatures be
The most thermally efficient and cost effective
exceeded.
system is obtained when the lowest thermal
conductivity materials are placed in the hottest
Excellent Strength. Easy to install; resists damage
possible location. The excellent heat resistance of
both in installation and in operation.
Superex block allows this. The most thermally
efficient systems utilize Superex 1600 as backup
Lightweight Reduces structural steel requirements;
to Superex 2000.
ideal for insulating movable equipment.
Superex block is good insurance, too. Any refractory construction can be expected to crack in service and allow full furnace temperatures into the back-up insulation. Its high refractoriness will help to prevent catastrophic failure of important equipment and allow operation until a more convenient rebuild or
repair time is reached.
Special Shapes. Good strength properties make Superex block ideal for cutting and grinding special shapes. J-M can supply these to your specific requirements.
Sect. 140 Part 10 Date: 4-78 Cancels: 10-77
ATC 0034311
Spacwicaiion Data
Available Forms Superex 2000 -- A high-density, low-calcium oxide content block, designed for low shrinkage and top performance at temperatures up to 2000F.
Superex 1603 -- Has a higher calcium oxide content and lower density than Superex 2000. This formulation gives better strength and insulating properties for use in situations where temperature will not exceed 1600T.
Superex 2000 SG -- Composite insulation block made up of Superex and a layer of spun-attenuated glass fiber, bonded together at the factory. The fiber glass layer, consisting of 1000 Series Spin Glas*
increase the insulation effectiveness of the Superex block and also serves as a mechanical "cushion" between the block and the steel shell
of a furnace
Properties
Normal Service Temperature, F, (oxidizing atmosphere)
Superex Superex
2000
1600
2000
16000
Marking
None
Green strip on end
Density, Ibs/cu ft
24 14
Modulus of Rupture, fbs/sq in
45
65
Compressive Strength Ibsfeq in to produce 5% deformation (2" thickness)
130
165
Linear shrinkage, % after 24 hours soaking heat 2.7 @ 2000'F 1.4@1600F
Chemical composition, %
Silica,
S1O2
Alumina,
AI2O3
Calcium
Oxide
CaO
Ferric Oxide, FezOa
Titania,
Ti02
Magnesia. MgO
Alkalies, as Na20 & K2O
Sulphur
Trioxide, S03
Others
Loss on Ignition
74.8 4.3
6.0 2.0 0.3 0.8 2.7
0.0
--
9.1
49.6 1.2
37.6 0.3
Trace 0.2 0.0
Trace 0.2 10.9
Superex Slock insulation
Compressive Data on Superex 2000 SG (2Va" Superex 2000 plus %" 1000 Series Spin-Glas)
Compressive Strength of 3* Superex 2000 SG
Compressed As
Load to Compress, psi
Thickness Received Hot Face of Superex (24-hr test)
(in.)
1600'F
1800'F
1900'F
3.00 2.90 2.75 2.50 225
0 1.4 3.5 22.6 66.0
0 0.6 2.4 21.1 29.0
0 0.4 1.5 12.5 70.0
0 0.4 1.6 13.5 73.0
Recovery of 3* Superex 2000 SG After Compression
Compressed Thickness of Superex 2000 SG after release
Thickness (Percent of original thickness) Hot Face of Superex
As (24 hour test) Inch % Received 1600'F 1800F 1900'F
2.90 2.75 2.50
97 99 92 99 83 95
99 99 99 97 97 97 93 93 93
Mean Temperature (F)
Standard Sizes
All dimensions in inches
Thicknesses in Ys> inch Superex 2000 Superex 1600
increments
1 to 5
1 to 4
Superex 2000 SG 1 Vi to 6
Widths and Lengths
12x36 6 x 36
12x18
18x36 12 x 36
6x36 18x18
Beveled blocks are tapered to specific requirements. Outside diameter of circle is to be specified on order.
Johns Manviile
Ken-Caryl Ranch Denver, Colorado 80217
For information on other
J-M Thermal Insulations and Systems, write the Johns-Manville Insulation Center, Drawer 17L, Denver. Colorado 80217 or call
(303)979-1000.
IND-30M 4 76
The physical properties of Johns-Manville Superex block
insulation represent typical, average values obtained in accordance with accepted test methods and are subject to
normal manufacturing variations. They are supplied as a technical service and are subject to change without notice. Check the Johns-Manville district office to assure current information.
ATC 0034312
<n sjSa
SKAMOLEX PM-10
Asbestosfree Calcium Silicate Slab Insulation.
An extremely lightweight calcium silicate slab, fibre reinforced but completely
free of any asbestos and crystalline silica. It is designed as a final back-up in
sulation between refractory linings and furnace casing for interface temperatu
res up to 1000C. A low density product - 250 kg/m* - of good strength and
low thermal conductivity throughout its temperature range of service. Excellent
resistance to carbon monoxide and a number of other gases, and good perfor
mance in contact with molten aluminium. The large sized slabs - standard size
1000 x 610 mm - of accurate shape and clean edges speed construction and
improve insulation efficiency. The slabs are easy and clean to handle because of
a negligible dust emission.
Due to their porous structure the slabs are easily shaped on site by ordinary
woodworking tools - fixing'can be made with nails or screws. A specially de
veloped adhesive is also available.
ATC 0034313
S KAMOLEX PM-10
Asbestosfree Calcium Silicate Slab Insulation
Bulk density (dry)................................... 250 kg/mJ Porosity................................................... 89% Cold crushing strength.......................... 2.0 MN/m?
(20 kp/cm1) Compressivestrengthat5%deformation1.7 MN/m1
(17 kp/cm1) Modulus of rupture................................ 0.6 MN/mJ
(6 kp/cmJ)
Recommended service temperature
(back-up)................................................. 1000C
Linear reheat shrinkage
DIN 51066 BL.2(12h950C).............. <1.5%
Specific heat.................
075kJ/kgK
(0.18 kcal./kgC)
Thermal conductivity at mean temp. W/m K
10C.... .. 0.054 200C___ .. 0.065 400C___ .. 0.087 600C___ .. 0.109 800C___ .. 0.132
Kcal./m.h.C 0.046 0.056 0.075 0.094 0.114
Pyrometric cone equivalent.................. 1400C Thermal expansion coefficient 20-730C............................................. 0.74x10/K
The above properties represent average test values. They are given in good faith but no guarantee is im plied.
CnCAlAilTALYS!
SiOz........................... CaO............................ Fe20s........................
AI2O3................................
Ignition loss................ (rnainlv H2O and CO2)
41 % 42 %
0.5 % 1.2 % 13 %
Skamolex PM-10 is available as flat boards of stan dard size 1000x610 mm with thicknesses of 2530-40-50-60-75-100 mm. Other sizes or shapes, e.g. with bevelled edges, can be supplied to suit spe cific design requirements.
For agglutination of slabs, or for adhering Skamolex PM-10 to refractory and metallic surfaces, we recom mend the use of SKAMOL FL-06 Mortar. This adhe sive is supplied as a dry mix in 25 kg bags, ready for use after addition of water. Adhesive thickness should not exceed 5 mm.
Skamolex PM-10 in standard size 1000 x 610 mm is offered in shrink film wrapped packs holding be tween 1.83 and 6.10 m* of board depending on thick ness. Packs are palletised for shipment on nonreturnable pallets, secured with nylon strapping. One pallet unit comprises 2.25 mJ shipping volume.
PACKING SPECIFICATION
Thickness mm
25 30 40 50 60 75 100
Content per pack
slabs
ma
10 6.10
10 6.10
5 3.05
5 3.05
5 3.05
3 1.83
3 1.83
Content per pallet
packs
m*
14 85.4
12 73.2
18 54.9
14 42.7
12 36.6
16 29.3
12 22.0
Packing in wooden crates or cases quoted upon re quest.
j
uya
a
SKARREHAGE MOLERWERK '/s
DK-7900 NYK0BING MORS . DENMARK . TEL. INTERN. 45-7-72 15 33 . TELEX 66680
ATC 0034314