Document YjNpQmOmMOJZ4M6R9a4J9rYen

III. PUNT HOUSEKEEPING AND EMPLOYER SAFETY The following procedures and limits are intended to be minimum requirements to be met by manufacturers and users of capacitors containing askarel. Handling, control and disposal procedures are given, together with exposure limits and indicated anti* dotes and cleanup procedures. 1. Material^. Askarel for use In capacitors should consist of homologues and Isomers of chlorinated biphenyl with the pcntuchloro and higher fractions not exceeding 0.4%. Aroclor 1016 is considered the standard Imprcgnant meeting these requirements. Solvents Include benzeno, kerosene, acetone, amyl alcohol, ether, and chloro form. Typical vapor pressure data for Arocior 1016 are: 0*C 0.001 mm 25*C - 0.006 mm ' 150C * 4.3 mm 200*C - 29.0 mm At 25*C and 760 mm Hg pressure, saturated air contains approximately 0.09 mg/llter. (1 mg/liter 90.0 ppm (v/v)) (1 ppm (v/v) 0.011 mg/liter) 2. Bulk Fluid Shipments Receiving* and Transfer. Shipment of askarel from point of manufacture to point of receiving should be done In closed containers: mil tank cars; truck tanks; marine or barge tanks; or scaled drums. Containers should be labeled a9 to contents, and carry a label cautioning against loss of fluid to the open environment. Containers used for transport of askarel should not be used for storage or transport of other material without being completely cleaned of all traces of Askarel. (Cleuning procedures must take cognizance of precautions against excessive exposure and of the need for proper disposal of contaminated cleansing solvents and materials as set forth In Suction VI.) Transfor from shipping containers to processing systems should bo through closed piping or tubing with appropriate valves, pumps, etc. Provision should be made for crapping and disposing of fluid lost by leakage or spills from the transfer system and from the storage containers. Drums to be retired from use should be cleaned before crushing, delivery to scrap dealers, or other disposal. Contaminated cleaning fluids and materials should be disposed of as indicated In Section VI. 3. Concral Safety Precautions. Although it is generally accepted that exposure lo capacitor grade askarel in not hazardous provided simple precautions are taken, exposure should still bo avoided. (a) Vapors. Tho odor of nskArel is noticeable well below the maximum air concentration!) considered safe. Maximum atomosphcrlc concen tration limit (B bourn exposure) should not exceed one milligram of capacitor grado aakarel per cubic meter of air. Page 3 MQNS 040636 (a) Vapors (cont'd.) Breathing vapor or fumes from heated aakarel should be avoided, Provldlons muse be made for adequate ventilation and regulation of manufacturing operations to avoid open exposure to aakarel (especially at 55C or higher). The gases produced, when askarcl la decomposed by very high temperatures (such au that of an electric urc) In the presence of nlr or organic insulating materials, contain a high percentage of hydrogen chloride, and small percentages of carbon dioxide, carbon monoxide, and oxygen. Minute concentrations of this combination of gases are very unplcanant and Irritating, thus giving ample warning of their presence. If exposure to high concentrations of askarcl is necessary under emergency conditions, an approved gas mank or self-contained breathing apparatus must be worn. Such exposure should be under the surveillance of other person nel capable of rescue In case of an accident* If the odor of aakarel la detected by the person wearing protective equipment, he should immediately go into fresh air. All gas masks, respirators and replace ment parts should have Bureau of Mines approval, and be maintained on e regular schedule in accordance with the manufacturers' recommendation. (b) Fluid. Unlike insulating oil, there Is virtually no fire hazard In handling askarcl. A limited solvent action (similar to that for paint thinner) on the fats and oils of the akin with prolonged contact may lead to drying and chapping of the skin. As with insulating oil, some people nre allergic to aakarel and continued exposure may result In akin irritation. Both the liquid and vapor are moderately Irritating to the eyo tissue. Operating procedures should bo such ns to minimize or eliminate contact with askarels. Use of eye protection is recommended. The use of porous gloves which can absorb and retain askArels Is to be avoided. Barrier creams (e.g. PLY No. 9 Cel by Milburn Co., Detroit, Michigan or Kerodcx #71 distributed by Ayers Laboratories, P. 0. Box 8236, Church Street Station, New York, New York 10049) or resistant gloves* should be used If contact la unavoidable. Use of enclosed transfer and handling equipment, processing equipment, and mechanical washers reduces direct contact. Medicinal washes or mild detergents followed by application of cold cream will reduce Irritation resulting from askarel contact with an open cut or abrasion. Safety glasses with side shields or a face shield should he worn when bundling asknreln. If eye contact to liquid aakarel occurs, the eyes uhould bo irrigated Immediately with largo quantities of running water for fifteen minutes and then examined by a physician. (A drop of castor oil has been found to reduce irritation caused by eye contact). Persona developing a skin irritation or respiratory tract irritation while working with aakarels should bo placed under the supervision of a physician. MONS 040637 *K.rimont, Solvit 5-352, sold by Merslck of Bridgeport, 22 Crous Street, Bridgeport, Conn. 06601. Page 4 (b) Fluid (contM.) Ingestion or swallowing of askarels Is not generally regarded as a problem of the Industry. Askarels are regarded as being moderately toxic If taken Internally, and could cause irritation of the digestive tract and internal reactions. Hands should be washed clean of askarels with warm water and soap before eating, drinking, smoking or use of toilet facilities after handling. 4. Manufacturing Housekeeping. Manufacturing equipment and operating procedures must safeguard against loss of askarels to the environment through proper containment and disposal procedures. Enclosed systems of sealed piping, properly gasketed Joints, valves, containers, and processing chambers are to be used for any portion of the operation where askarcl temperatures may exceed 55*C. Enclosure should preferably extend to all other portions of the system Insofar as practicable. Containment provisions should be established around all askarel processing areas to assure against Inadvertent loss to sever systems by spillage, leakage, or other uncontrolled conditions or events. Ventilation of the area and exhaust of pump and systems gases should be controlled to restrain vapor losses to the atmosphere (see Section V). Spills of askarel should be removed promptly by use of absorptive material such as sawdust, or trapped and removed by pumping or other suitable means. Waste fluids containing askarel not suitable for reconditioning or reuse should be collected (by means of traps, drip pans, trays, etc.) from the various parts of the manufacturing and processing area (Including washers or other cleaning devices). Disposal should bo in approved Incineration facilities or In clean landfill areas In sealed containers. If permitted (sco Section VI). Wiper rags, clothing and other extraneous materials saturated with aakarela should be collected within the containment area for properly controlled In-plant laundorlng or disposal (see Disposal of Liquid and Solid Scrap Section VI ). Outside commercial laundering or dry cleaning services should be uaod only If their disposal procedures ate consistent with the guidelines In Section VI. 5. Dinpoanl of Askarel W/mtes. Methods for disposal of liquids and saturated solids generated by the manufacturing operation should be In accordance with those outlined in Section VI of this Guide, and should Include (but not be limited to) the following: A. Liquid aoksrel contaminated by aliphatic materials und other oubstanctts ouch as to make it unsuitable for reclaiming as e dielectric fluid. D. Liquid askarel from solvent operations or watsr/detsrgont type wushors. Page 5 HONS 04063b 5. Disposal of Askarel Wastes (cont*d.) C. Saturated earth or other absorbent media from filtering operations. D. Saturated sawdust or other absorptive materials from spills. IS. Saturated filters from vapor control devices and other filters. F. Saturated wastes (paper, rags, etc.) C. Saturated, spent gasket materials. H. Askarel contaminated vacuum pump oils. . I. Askarel contaminated stream Jet vacuum system condensates. 6* Miscellaneous Procedures A. Spills by leakage from finished capacitors should be cleaned up promptly by use of absorbent media which should then be moved to containers for that purpose within the containment area, and later disposed of properly. H. Askarel wastes should never be disposed of down effluent drains or sewers. The utmost cars must be exercised to prevent accidental loss by these avenues to the environment. C. Capacitors falling test or otherwise designated for disposal must bo controlled and handled In accordance with the Intent of the procedures above, finally being disposed of by one of the means outlined in Section VI. 7. References A. Monsanto Company, Organic Chemical Division: Tech. Dulletln fPL-306, Aroclor Plasticizers (December 1960). H. American Conference of Governmental Industrial Hygienists: Thrcsltold Limit Values for 1964. AMA Arch. Knvlron. Health 9:545 (1964) C. Troon, J.F., F.P. Cleveland, J. Cnppc), and R.W. Atcbley: The Toxicity of the Vapors of Aroclor 1242 and ArocJor 1254. Amor. 1ml. Hyp. Assoc, Quart. 17:204 (1956). D. Elkins, II. B.: The Chemistry of Industrial Toxicology. John Wiley ond Sons, Inc., New York (1959). F.. Drinker, C.K., M. F. Warren, and (J. A. Bonnet: The Problem of ToHslble Systemic Effects from Certain Chlorinated Hydrocarbons. J. Tnd. Hyg, Toxicol. 19:21*3 (1937), Page 6 MGNS 040639 7. References (cont'd.) F. Drinker, C.K.: Further Observations on the Possible Systemic Toxicity of Certain of the Chlorinated Hydrocarbons. J. Ind. Hyg. Toxicol. 21:155 (1939). G. Grecnburg, L., M.R. Mayers, and A.R. Smith: The Systemic Effects Resulting from Exposure to Certain Chlorinated Hydrocarbons. J. Ind. Hyg. Toxicol. 21:29 0939). H. Hygienic Guide Series "Chlorodiphcnyls" by the American Industrial Hygiene Association, 25711 So. Field Road, South Field, Mich. 48075. IV. CONTROL OF WATER EFFLUENTS The Industry goal 1b "zero" concentration of askarel In plant water effluent streams. However, It Is recognized that existing drain systems In capacitor manufacturing plants are probably contaminated as a result of post practices, and askarel traces may continue to show up In effluent streams for some time. However, the level should continue to decrease with the proper containment of askarel wastes and no further discharges Into drain systems. Other sections of this Guide provide that no askarel wastes of any kind be disposed of In any wator effluent streams, and that accidental spills be prevented from getting into such streams. A. Concentration Mmlts. The maximum allowable concentration of askarel in water should be 200 parts per billion. On a 24 hour basin, the askarel content of all plant water effluent streams shall not exceed five pounds. D. Monitoring Streams. On a regular basis not to exceed 3 month Intervals, and on a tnoro froquent basts if required by the local plant situation, all effluent streams should be analyzed to determine compliance with the Units in Part A. This can be done by taking a "worst" sample during the day, or a 24 hour composite. The procedures for performing the necessary analyses are contained In Section IV, ANALYSIS OF WATER AND SEDIMENT FOR POLYCHLORINATED DIPHENYLS (or Its equivalent). C. Methods for Minimizing Effluent Stream Contamination. The ideal approach is to totally leolato all offluent streams that could bo contaminated with askurcls during manufacturing processes and prevent them from being dlachsrged from tho plant. Procedures that could be Implemented to this end are as follows: 1. Collect aakarol bearing streams and either by gravimetric or centrifugal aeparatlon recycle the water phane for reuse und dispone of the askorel-rlch phase under the liquid disposal guidelines described clscvhcro herein. 2. In all manufacturing nroao where uekarel spills can occur, connect drains to an Isolated sump where the spills can bo accumulated and pumped out for disposal. Pfte 7 MONS 040640 C. Mothods for Minimising Effluent Stream Contamination (cont'd,) 3. Carbon adsorption, limestone beds, and solvent extraction are techniques which can be applied to reduce the askarcl content from effluent streams. This may be required to meet the limits defined in Part A above. This may be most appropriate In cleaning up water used In plant processing and recycled, but the residue will have to be disposed of ultimately. Such dis posal could be done through Incineration, but may be more practical by odaorptlvc purification. D. Procedure for Water Sampling. Initially all effluent streams from the plant should be sampled to determine levels and to identify which arc askarel bearing. Hourly samples of the streams should be taken during a typical operating period to insure the samples are representative of the effluent, or a single sample collected continuously over the operating period. The flow rates of the effluent streams should be measured when the samples are taken. The hourly samples from each stream are then composited in pro portion to the flow rate of the stream. Analyses of the composite samples are done in accordance with the procedures outlined In Section IX. The actual askarel discharge of any effluent can be computed from the quanti tative analysis of its composite samples and the mean flow rate of the stream. V. CONTROL OF VAPOR EFFLUENTS Normal plant ventilation will carry askarel vapors to the environment. The composition of askard In the vapor In expected to be higher In the lower chlorinated fractions of Aroclor 1016 which have the higher vapor pressures (and also have the higher degree of blodcgradablllty). A. Concentration Limits. The total plant atack emissions should not exceed five pounds per day. B. Monitoring. The monitoring of appropriate stack effluents should be done on a periodic basis not to exceed 3-months, and more frequently If requlrod by the local situation. Teat Method 70-6 contained In Section IX, PROCEDURE FOR THE DETERMINATION OF AIRBORNE POLYCHLORINATED BIPHENYLS (or Its equivalent) should be used. C. Other Considerations. Large exposed surface areas of askarel, especially if maintained at an elevatod temperature, will be the major contributor to any concentration of askarcls found In otnr.k effluents. Open containers should be oncloscd with vapor tight covurs to avoid this. D. Procedure for Air Sampling. Identify exhaust stacks which may contain air borne askarel. A composite sample from each stock should be gathered over S typical 24 hour operating period. The sample Is collected by aspirating a known volume of the exhaust gases through hexane. The acknicl, being soluble in hexane, will be collected and o quantitative determination can bo made through the use of gas chromatograph/clectron capture techniques as described In Section IX. From the quantitative determination nml with a knowledge of the volumetric flow rate of o given stack, the total weight of askarel discharge can be computed. Page ft MONS 040641 VI. SCRAP DISPOSAL PROCEDURES Tho manufacture and use of capacitors Involve processes producing askarel saturated ollda, and liquids containing or composed entirely of askarel, which must be dis posed of in a manner consistent with proper concern for the environment. Specific sources of these materials appear throughout this document but may be placed into three categories: A. Capacitor units impregnated with askarel; Production and Field Failures (mechanical or electrical); obsolete ltoms. 1). Manufacturing process liquid wastes containing askarel. C. Solid waste purposely or accidentally saturated with eekarel. PART A Disposal of Capacitor Units Scrap capacitor units can be generated during manufacturing processes, or during field eervlce. Production rejects are those capacitors which are rejected after the impreg nation process, In Die course of production by the capacitor manufacturer. They may be rejected for mechanical or electrical reasons, or because of obsolescence. . Field rejects are those which are rejected, or which for other reasons are to be scrapped, after shipment from the plant where they were manufactured. Disposal Procedures 1. Production Rejects Rejected capacitors are generatal in sizeable quantities in capacitor manufacturing plants, and because they represent e concentration of askarel, it Is important that their disposition bo made In a manner consistent with proper concern for the environment. Therefore, capacitors should be disposed of only In dry landfill sites which meet all applicable State requirements Care should bu exercised to insure that no loss of liquid will occur during transportation to the disposal site. Solid Incineration of scrap capacitors Is a disposal alternative ee uuch services become available In the future. 2. Field Rejects Small capacitors (defined ae containing less than 2 pounds of askarel) arc practically always used as components in other electrical or electro mechanical equipment. Typical examples of large quantity ucipe of auch capacitors arc in fluorescent lamp ballasts and residential air conditioning equipment. Failure of such capacitors may result in scrapping of the device of which It is n part (as in a fluorescent ballast), or replacement and scrapping of the individual capacitor (aa in a room air conditioner). However, the majority of euch capacitors Tage V HONS 040642 2* Field Rejects (cont'd.) do not fall in service, but are scrapped as a result of vearout or absolescence of the devices In which the capacitors are used as components. Thus, the matter of disposal 1b characterized by low concentration of small quantities of askarel throughout the country and indeed throughout the world. Fortunately, the nature of the devices and equipment in which such capacitors arc used Is such that they are normally disposed of in dry landfills as a matter of convenience. Since it is impractical at present to cxerclae any meaningful control over disposition of the bulk of such devices and equipment, It is imperative that askarel used for impregnating small capacitors be limited to the recently introduced type which contains a minimum concentration (0.4% maximum) of the higher chlorinated (5 or more chlorine atoms per molecule) components. Large capacitors (those Incorporating more than 2 pounds of askarel) should be disposed of according to the procedure for Production Rejects (sec paragraph 1 of this Section). PART ft Disposal of Liquid Wastes All wa9tc askarel or wastes containing askorel shall be disposed of according to one of the following procedures: Incineration: Facilities capable of Incineration at temperatures of at least 800"C, with minimum residence time of 1.5 seconds, and having exhaust gas scrubbing equipment as a part thereof shall be suitable for this purpose. These facilities shall meet applicable requirements of the State In which located, and shall control liquid and vapor effluents within the limits set forth In this document. Toxic and Hazardous Waste Disposal Sites: Certain landfill sites have been classified by State and Federal Governments as suitable for the disposal of toxic and hazardous liquids. Where such approved sites exist they may he used for the disposal of liquid wastes described in this document. (See Section VIII). The following guidelines shall be observed in the packaging and shipment of liquid wanton for dlapoaal. 1. Transportation to the incineration facility should ha In scaled containers which will prevent leakage and accidental loss of askarel to the environment. 2. Containers should be labeled an to contents and precautions relative to loss to the environmont. 3. Container!) used for this purpose should not be used foi uny other materlalo or retired from service until they arc completely cleaned. Any solvents used In cleaning tlioue containers will be contaminated with askarel and should he disposed of according to the name procedures herein dencrlbcd. Fogc 10 MGNS 040643 PART C Diagonal of Solid Wastes (see Part A for Scrap Capacitors) All solid wastes which have been saturated with askarel should be disposed of by the following procedure; The saturated wastes shall be placed into leak-proof containers and transported to a dry landfill site meeting State require ments as described In Part B of this Section. Alternatively, they can be disposed of by incineration in State approved facilities. Solid absorbents used for spills can be disposed of uncontalned in the dry landfill site -- transport to the site shall be In closed containers, Alternatively, solid incineration can be used in accordance with Part B (see Section VIZI for facilities). VII. ?,ABELINC Capacitor units vary greatly in size and in end use or application. Small capacitor units aro frequently applied aa a component of another piece of equipment such as a fluorescent lighting ballast, a roadway or araa lighting luminaire, a motor, etc. In such applications a label on the capacitor unit referencing approved disposal procedure would not normally be visible when the piece of equipment Is disposed of. For the above reasons the method of relating dtapoaal instructions for small capacitors end large capacitors shall be treated separately and in the following manner. Small Units (Incorporating less than 2 pounds of askarel) hefInitlon Small capacitors are define as those which contoln askarel in quantities up to about two (2) pounds each and in which the free liquid does not exceed about 0.4 pound. They ore hermetically sealed in metallic cases. Such capacitors are applied as a component of a larger piece of equip ment. Attaching a label to such equipment referencing this Guideline or describing disposal procedures would be of limited practical voluo. The amount of askarel Involved In disposal of a single such equipment, the frequency of ouch disposal, the localized concentration of askarel resulting from such failed equipments, and the likelihood that the small capacitor Is still a sealed unit arc factors suggesting minimum environ mental effects. Therefore the appropriate labeling of small capacitor units or equipments in which they aro usad is not considered necessary. l.nrgeCnpacltor Units (Incorporating more than 2 pounds of askarel) The capacitor manufacturer should affix a label In a conspicuous place, referencing this document or describing disposal procedures consistent with it. This label la available from NEMA and will road aa followa: Pago 11 HONS 040644 NOTICE This capacitor contains PCN's. To avoid possible environmental contamination, it should be disposed of only in dry landfill areas meeting State require ments or in approved Incineration facilities. SEE AMERICAN NATIONAL STANDARDS INSTITUTE GUIDELINE^ for instructions. VIII. DISPOSAL SERVICES In addition to the managed, clean dry landfill sites which may be used for disposal of Asknrc-1 and askarcl-contolnlng scrap, the following additional facilities and services are also currently available; CIIKM-TROL POLUTION SERVICES, INC. A. Contact Mr. T. J. Reese 4818 Lake Avenue Hlasdell, New York 14219 Phone 716-826-5850 D. Facilities and Services Capable of Handling . Liquids - Askorels alone or mixed with solvents or oils. Disposal by high temperature Incineration. Solids (Software) - Askarcl soaked compounds, rags, cartons, absorbing earths, etc. Disposal by incineration or scientific landfill. Solids (Hardware) - Capncltors,, transformer tanks, cores, askarel soaked metals. Disposal by scientific landfill. Has solvent extraction capability. MONSANTO COMPANY A. Contact Mrs, Carol .Tordon 800 N. Lindbergh Blvd. St. Louie, Missouri 63166 Phone 314-694-3352 Page 12 KONS 0406^*5 D. Facilities Capable of Handling Liquids - Askarola alone or mixed with other oils or solvents by high temperature incineration. Liquid is pumped through gun with atomising steam into Incinerator. Temperatures maintained at 2000-2500*F with auxiliary natural gas. Kxit gases arc quenched to 160F by contacting with water. Cas is then passed through a high-energy venturi scrubber for removal of partic ulates. before exhausting to air (110*F), gases are passed through a packed column scrubber to remove HCl. Normal capacity of incinerator is 10,000,000 lbs/year. The PCB dcfractlon efficiency is 99.9992; the HCl scrubbing efficiency Is 99.82. NUCLEAR ENGINEERING COMPANY A. Contact Nr. Donald Hopper or Mr. B. V. Roberts Eastern Division T. 0. Box 146 Morchead, Kentucky 40351 Phone 606-784-6611 or Mr. Arvll Craae Disposal Division Sheffield, Illinois Phone 615-454-2624 B. Facilities and Services Capable of Handling Provides containerization, transportation and disposal services for all liquids and solids (Including hardware). Disposal Is in controlled chemical and scientific landfill area. AEC licensed for radioactive waste disposal. Has two Wsst Coast locations In states of Washington and California In addition to above, - Page 13 HONS 040646 ROLLINS-PURLK. INC, A. Contact Mr. Stanley Hllteblddle Box 2349 Wilmington, Delaware 19899 Phono 302-478-5150 B. Facilities and Services Capable of Handling Liquids - Askarol alone or mixed with solvents or olio. Disposal by high temperature Incineration* Solids (Software) - Askarel soaked compounds, rags, cartons, absorbing earths, etc. Disposal by Incineration at combustion temperatures up to 2500K. Inciner ation gases are ncrubbed, and entrained solids removed before exhausting to air. Disposal facilities arc ovallable at the following locationsi LoganI Rolllna-Purle,lnc. Route 322 Logan Township Bridgeport, New Jersey 08016 Baton Rours: Rollins-Purle, Inc. Scenic (Ivy. & U. Cheatham Lane Scotlandville East Baton Rouge Parish Louisiana 70807 Houston? Rollins-Purle, Inc. Tidal Road & Hvy. 134 Dear Park, Texas 77536 HONS 040647