Document YjEy2OrVxJ1XKaqvrqLBd9ydn
Heating
S_ystem
Oil Burners Water Heaters
Air Conditioning Doit
Ray Oil Burner Co.
Since 1872
401-499 Bernal Avenue San Francisco 12, Cal.
Distributors in All Principal Cities of the World
Atlantic Seaboard Division 629 Grove Street
Jersey City 2, N. J.
Consult your local Telephone Directory
Products: A complete line of Horizontal Rotary and Pressure Atomizing Oil Burners;
Combination Oil-or-Gas Burners; Industrial Gas Burners; Oil Burning Water Heat
ers; Winter Air Conditioning Units, Commercial Ranges.
-----9
Air Conditioning Unit
Ray Oil Burner Co. Since 1872
401-499 Bernal Avenue San Francisco 12, Cal.
Atlantic Seaboard Division 629 Grove Street
Jersey City 2, N. J.
There is a RAY Burner for every Heating Purpose.
RAY COMBINATION OIL-GAS BURNER
Type ARC-131
Type ARJP, Fully Au tomatic. for heavy oil where gas for ignition not available.
Fully Automatic Type AR-lS4,for No. 6 oU-
Combination Oil and High Pressure Gas, Type AR-HN.
Quad-Naught for VSoU, manual operation.
Steam Turbine Drive, Type TG, all grades oU. Texted and approved for
U. S. Navy Service.
Four, 3 oven, fully auto matic oU Ranges.
RAY HORIZONTAL ROTARY OIL BURNERS
Built in fully automatic, semi-automatic and manual types; in sizes from 1 to 1000 Boiler hp; to burn all grades of fuel oil.
Standard models include both direct and belt drives--the
latter being recommended for use where other than 50 or 60 Cycles AC, or only DC is available. Types for straight elec tric or straight gas ignition; pump or gravity feeds. Direct
drive types include a steam turbine driven model. All fully automatic types for heavy oil incoiporate the Ray
Dual Pump and Reservoir, with the Ray VISCOSITY Valve,
a patented, exclusive feature which automatically meters the
correct amount of fuel at all times, regardless of changes in viscosity of the oil due to temperature variations. All larger
sizes employ dual ignition, for maximum reliability.
RAY PRESSURE ATOMIZING OIL BURNERS Fully automatic, for No. 3 oil or lighter. AC or DC; capaci
ties to 18 gal/hr..
RAY INDUSTRIAL GAS BURNERS
For gas pressures above 1 lb/sq in. may be used alone or in combination with a Ray Oil Burner. Built in eleven sizes; in
capacities to 43,000,000 Btu/hr.
RAY WINTER AIR CONDITIONING UNITS Built in four sizes, with input capacities of 105,000, 140,000,
230,000, 350,000, 450,000 Btu.
RAY OIL WATER HEATERS Two sizes. Capacities: 45 and 75 gal. Maximum recover rates: 154 and 240 gph.
RAY OIL FIRED RANGES
Available in
sizes for manual or fully automatic
operation.
Type BR-Hl, Bdt Drive Automatic. Available in
9 sizes from to 100 gph.
Ray OH Furnace, Winter Air Conditioning Unit.
Small capacity (1 to 4} gph) rotary burner.
1322
Fully Automatic, Type JP, 3 or lighter oH.
Burns any grade of gas or
heavy fuel oil and the opera tion is fully automatic for either fuel. Prevention
against ignition or flame failure one hundred per cent electronically controlled.
Develops from 7 to 335
Boiler hp. Quickly inter changeable in two to three
minutes. Other types with choice of direct or belt drive,
also sizes rated from 120 to 1000 Boiler hp.
HOURLY CAPACITY RATINGS of RAY OIL BURNERS
J M otor
H .P .
Burner Size
JP XPJ XPJ-1 XP-2
1
\
0000
000 00 0
^0
it
1
14
2 3
1
51
6H
72 83
95
10 12
3
Oil Capacity U. S. Gallons
Max.
13 14 38 8 18
0.5 2.5 0.5 2.5
2.5 25
4 5 8.
11 15 20
10 33 12 50 15 67 25 100
35 150 50 210 75 1 320
Equivalent Boiler HP
Mm.
3 3 9 25
Max.
9 12 25 56
28 28 38 7 16
13 35 17 50 27 65
35 no
40 165 50 225 85 335
120 500 165 700 250 1000
Equivalent Lbs. Steam Generated
Min. | Max.
110 325 110 430 325 865 865 1950
60 290
60 290 110 290
230 580
460 1250 580 1720
930 2300
1150 1400 1720 2900
3800 5800
7750 11500
4000 5800 8700
17400
24400 37000 1
Heat Capacity Input Thou. Btu
Min.
140 140 420 1120
Max.
420 560 1120 2500
75 375 75 375 150 375 300 750
600 750 1200
1650
2250 3000
1500 1800
2250 3750
4950 7500
10000 15000
5250 7500
11250
22500 31500
48000
Equivalent Sq. Ft. Steam Radiation
438 438 1310 3500
234 234 469 938
1870 2350 3750
4690 5620 7030 11700
--
1310 1750 3500 7900
1170 1170 1170 2350
5170 7030 9380
15500 23400 31400 46900
-
NOTE: These ratings ere predicated upon specific conditions of draft and furnace volume. It may be per-
operate id'reduced'rates?3' * op^* " ^
<**
cu,,T
Hcapacities are baaed upon 150,000 Btu per gal of oil for rotary burners and 140 000 Btu ocr gal of oil for pressure atomizing burners and upon aa overall boiler efficiency of 75 per cent. ^
1323