Document YjEy2OrVxJ1XKaqvrqLBd9ydn

Heating S_ystem Oil Burners Water Heaters Air Conditioning Doit Ray Oil Burner Co. Since 1872 401-499 Bernal Avenue San Francisco 12, Cal. Distributors in All Principal Cities of the World Atlantic Seaboard Division 629 Grove Street Jersey City 2, N. J. Consult your local Telephone Directory Products: A complete line of Horizontal Rotary and Pressure Atomizing Oil Burners; Combination Oil-or-Gas Burners; Industrial Gas Burners; Oil Burning Water Heat ers; Winter Air Conditioning Units, Commercial Ranges. -----9 Air Conditioning Unit Ray Oil Burner Co. Since 1872 401-499 Bernal Avenue San Francisco 12, Cal. Atlantic Seaboard Division 629 Grove Street Jersey City 2, N. J. There is a RAY Burner for every Heating Purpose. RAY COMBINATION OIL-GAS BURNER Type ARC-131 Type ARJP, Fully Au tomatic. for heavy oil where gas for ignition not available. Fully Automatic Type AR-lS4,for No. 6 oU- Combination Oil and High Pressure Gas, Type AR-HN. Quad-Naught for VSoU, manual operation. Steam Turbine Drive, Type TG, all grades oU. Texted and approved for U. S. Navy Service. Four, 3 oven, fully auto matic oU Ranges. RAY HORIZONTAL ROTARY OIL BURNERS Built in fully automatic, semi-automatic and manual types; in sizes from 1 to 1000 Boiler hp; to burn all grades of fuel oil. Standard models include both direct and belt drives--the latter being recommended for use where other than 50 or 60 Cycles AC, or only DC is available. Types for straight elec tric or straight gas ignition; pump or gravity feeds. Direct drive types include a steam turbine driven model. All fully automatic types for heavy oil incoiporate the Ray Dual Pump and Reservoir, with the Ray VISCOSITY Valve, a patented, exclusive feature which automatically meters the correct amount of fuel at all times, regardless of changes in viscosity of the oil due to temperature variations. All larger sizes employ dual ignition, for maximum reliability. RAY PRESSURE ATOMIZING OIL BURNERS Fully automatic, for No. 3 oil or lighter. AC or DC; capaci ties to 18 gal/hr.. RAY INDUSTRIAL GAS BURNERS For gas pressures above 1 lb/sq in. may be used alone or in combination with a Ray Oil Burner. Built in eleven sizes; in capacities to 43,000,000 Btu/hr. RAY WINTER AIR CONDITIONING UNITS Built in four sizes, with input capacities of 105,000, 140,000, 230,000, 350,000, 450,000 Btu. RAY OIL WATER HEATERS Two sizes. Capacities: 45 and 75 gal. Maximum recover rates: 154 and 240 gph. RAY OIL FIRED RANGES Available in sizes for manual or fully automatic operation. Type BR-Hl, Bdt Drive Automatic. Available in 9 sizes from to 100 gph. Ray OH Furnace, Winter Air Conditioning Unit. Small capacity (1 to 4} gph) rotary burner. 1322 Fully Automatic, Type JP, 3 or lighter oH. Burns any grade of gas or heavy fuel oil and the opera tion is fully automatic for either fuel. Prevention against ignition or flame failure one hundred per cent electronically controlled. Develops from 7 to 335 Boiler hp. Quickly inter changeable in two to three minutes. Other types with choice of direct or belt drive, also sizes rated from 120 to 1000 Boiler hp. HOURLY CAPACITY RATINGS of RAY OIL BURNERS J M otor H .P . Burner Size JP XPJ XPJ-1 XP-2 1 \ 0000 000 00 0 ^0 it 1 14 2 3 1 51 6H 72 83 95 10 12 3 Oil Capacity U. S. Gallons Max. 13 14 38 8 18 0.5 2.5 0.5 2.5 2.5 25 4 5 8. 11 15 20 10 33 12 50 15 67 25 100 35 150 50 210 75 1 320 Equivalent Boiler HP Mm. 3 3 9 25 Max. 9 12 25 56 28 28 38 7 16 13 35 17 50 27 65 35 no 40 165 50 225 85 335 120 500 165 700 250 1000 Equivalent Lbs. Steam Generated Min. | Max. 110 325 110 430 325 865 865 1950 60 290 60 290 110 290 230 580 460 1250 580 1720 930 2300 1150 1400 1720 2900 3800 5800 7750 11500 4000 5800 8700 17400 24400 37000 1 Heat Capacity Input Thou. Btu Min. 140 140 420 1120 Max. 420 560 1120 2500 75 375 75 375 150 375 300 750 600 750 1200 1650 2250 3000 1500 1800 2250 3750 4950 7500 10000 15000 5250 7500 11250 22500 31500 48000 Equivalent Sq. Ft. Steam Radiation 438 438 1310 3500 234 234 469 938 1870 2350 3750 4690 5620 7030 11700 -- 1310 1750 3500 7900 1170 1170 1170 2350 5170 7030 9380 15500 23400 31400 46900 - NOTE: These ratings ere predicated upon specific conditions of draft and furnace volume. It may be per- operate id'reduced'rates?3' * op^* " ^ <** cu,,T Hcapacities are baaed upon 150,000 Btu per gal of oil for rotary burners and 140 000 Btu ocr gal of oil for pressure atomizing burners and upon aa overall boiler efficiency of 75 per cent. ^ 1323