Document YjD38g16dN1Rj2rdn4zdwjBD8

Inspection ID Class I and II Well Inspection Form US Environmental Protection Agency - Region 4 Underground Injection Control Program 61 Forsyth Street SW, MC 9T25, Atlanta, Georgia, 30303 Phone: (404)562-9424 Inspector(s): Anthony Shelton Carol Chen _ (lead), , EPA Well ID#: Year-Month-Day: 2 0 2 1 - 1 1 - 1 8 EPA Permit # (or RA): Page 1 Of 2 Carl Weller Start Time: 11:32 am End Time: 11:40 am Facility Contact Information Facility Name: PETRO HARVESTER OPERATING COMPANY, LLC Street Address: 1107 W 6th St (office address) City: Laurel County: Jones Nature of Business: Oil and gas extraction industry Facility Owner/Operator: PETRO HARVESTER OPERATING COMPANY, LLC Email: kerry.allen@rockallenergy.com Facility Contact (if different): Kerry Allen, Sr. Operations Manager O/O Mailing Address: 1107 W 6th St (office address) City: Laurel County: Jones State: MS Zip: 39440 Phone: 601-651-2100 Phone: 601-651-2105 State: MS Zip: 39440 Well Data from File Well Name & #: Laurel Field Unit (LFU) 36-13 #1 Well Type (see table): Produced Fluid Disposal, UIC Class II Latitude (N): 31.69891 Longitude (W): State Permit: API#2306720409-01-01 -89.1613 Elevation (ft): 218'(Gr) Injection Method (check applicable): Casing Injector; X Tubing & Packer; Cemented Injection Tubing PBTD@4106' Other: Total Depth (ft): 11,500' Inner Casing Size (in): Inj. Zone: Open Hole; X Perforated; Top(ft) 4,020' 5 " Tubing Size (in): 2 " Packer Depth (ft): 3943.98' Bottom(ft): 4,078' Max. Injection Pressure (psig): 682 psi Latitude (N): 31.69890 Longitude (W): -89.16133 Elevation (ft): EPA GPS ID: SX8123 Well Status (see table): TA If not Active, Reported Date Last Active: 9/1/2016 Nature of Injected Fluid(s) if any: Produced fluids General Condition of the Well Site: NA Field Measurements and Observations Notes & Comments (include discrepancies from database values): Tubing gauge: 0 psi Annulus gauge: 0 psi Field hand on-site stated that no injection pump was on this location since 2016 and tanks may contain some rainwater along with produced fluids. 40% produced fluids were visible in 2 tanks of 400 bbls, 60% produced fluids were visible in 4 tanks of 210 bbls. Perforations provided by field hand on-site are: 4,020' to 4,034' 4,050 to 4,078 See reverse for additional observations, comments and photo log Owner/Operator Representative (Optional) UIC Inspector Name: Signature: Name: Signature: Anthony Shelton ANTHONY SHELTON Digitally signed by ANTHONY SHELTON Date: 2022.01.19 10:05:38 -05'00' Version 2018-04-18 Inspector Carl Weller's signature: CAROL CHEN Digitally signed by CAROL CHEN Date: 2022.01.18 17:41:32 -05'00' Inspector Carol Chen's signature: Inspection ID Field Measurements and Observations (Cont.) Class I and II Well Inspection Form US Environmental Protection Agency - Region 4 Underground Injection Control Program 61 Forsyth Street SW, MC 9T25, Atlanta, Georgia, 30303 Phone: (404)562-9424 EPA Well ID#: Year-Month-Day: 2 0 2 1 - 1 1 EPA Permit # (or RA): Page 2 - 1 8 Of 2 (Cont) Laurel Field Unit (LFU) 36-13 #1 36-13-1 Class II Well/SPCC Observations: The operators informed the inspection team that the drilling field has two 16,800 gallon aboveground storage tanks (AST)s on site that are approximately 40 % full with produced fluids and four 8,820 gallon ASTs on site that are approximately 60 % full with produced fluids. The inspection team did not observe any other ASTs in this drilling field. The P.E. certified SPCC Plan for this drilling field stated that soil should be used for secondary containment for the six ASTs. The tank farm uses soil (permeable material) as a secondary containment for the six aforementioned ASTs. The six ASTs were badly rusted and looked like they were poorly maintained. Team's observations/comments: We Inspected 8 wells that day, with a total of 9 people: 4 from Petro Harvester, 2 from MSOGB and 3 from EPA. All inspected wells were located in areas that were fenced and gated. All the pumping units and injection pumps were in good condition and operated almost silently. The well locations seemed to be kept clean and organized. The focus of this inspection was well 36-13-1 which was TA with 0 psi on Tubing and 0 psi on Annulus. Also, the well was chained and locked in the closed position. Photo Log Photographer: Carl Weller Photo ID: 107 Time: 11:33 am EPA Camera ID: Lat (N): 31.69887 SX8123 Long (W) Description: Photo ID: overview, no injection pump, (2) 400 bbl tanks, (4) 210 bbl tanks 108 Time: 11:36 am Lat (N): 31.69896 Long (W) Description: well site Photo ID: Time: Lat (N): Long (W) -89.16132 -89.16129 Description: Photo ID: Time: Lat (N): Long (W) Description: Photo ID: Time: Lat (N): Long (W) Description: Photo ID: Time: Lat (N): Long (W) Description: Owner/Operator Representative (Optional) Name: Signature: Inspector Carl Weller's signature: UIC Inspector Name: Anthony Shelton ANTHONY Signature: SHELTON Digitally signed by ANTHONY SHELTON Date: 2022.01.19 10:06:02 -05'00' Version 2018-04-18 Digitally signed by CAROL CAROL CHEN Date: 2022.01.18 17:42:06 CHEN Inspector Carol Chen's signature: -05'00'