Document Yj9J2KY4GzQ740dLpdLZEdb1N
ENVIRONMENTAL ADVISORY GROUP, INC. INDUSTRIAL HYGIENE EVALUATION OF TISCO, INC. FOR ASBESTOS ABATEMENT PROJECT AT UNION CARBIDE CORPORATION TEXAS CITY, TEXAS JANUARY 11, 1996
ENVIRONMENTAL ADVISORY GROUP, IRC. 712 SPENCER HWY., SUITE 200 . SOUTH HOUSTON, TEXAS 77587
UCTC 04500
Cl - 0000057
TABLE OF CONTENTS I. SUMMARY II. FIELD NOTES III. LAB RESULTS IV. MISCELLANEOUS
UCTC 04501 Cl - 0000058
PPRPOSE 1) 2)
3)
4)
To document the events as they happen throughout the abatement project.
To monitor the client per OSHA regulations outlined in Appendix A to 1926.1101 by monitoring the clients employees.
To determine the concentrations of airborne fibrous particulate using Phase Contrast Microscopy (PCM) and the NIOSH 7400 method.
To report (and post on site) the concentration of airborne fibrous particulate to the client and/or his representative(s). In the event of any OSHA or EPA violation, recommendations will be made to help resolve the problem.
SUMMARY
1) Scope of work:
The removal of approximately 1 square foot of ACM from two (2) tanks at building #116.
2) Conclusions:
a) The respiratory protection utilized by the workers in the enclosure provided a protection factor of 10 times the permissible exposure limit of 0.2 fibers per cubic centimeter of air (f/cc).
b) The contractor put forth his besteffort to comply with all the rules and regulations for asbestos removal.
UCTC 04502 Cl - 0000059
UCTC 04543 Cl - 0000054
AIR SAMPLE FIBER COUNT LABORATORY ANALYSIS REPORT
RESULTS:
EAG SAMPLE NUMBER: 825A001
CLIENT SAMPLE ID: DATE: 01/11/96 NAME: N/A SS #: N/A
LOCATION: SEE DRAWING
REPORT DATE: 01/15/96
PAGE NO. 01
EAG JOB NUMBER: TX-2825
DATE ANALYZED: 01/12/96 VOLUME OF AIR: 350 EFFECTIVE FILTER AREA: 385mm*
FIELD AREA: 0.00785 mm* FIBERS / FIELDS COUNTED: 4/100
FIBERS / CC: <.01
yst
UCTC 04544 Ct- 0000063
AIR SAMPLE PIBER COUNT LABORATORY ANALYSIS REPORT
RESULTS:
EAG SAMPLE NUMBER: 825A002
CLIENT SAMPLE ID: DATE: 01/11/96 NAME: N/A SS#: N/A
LOCATION: SEE DRAWING
REPORT DATE: 01/15/96
PAGE NO. 02
EAG JOB NUMBER: TX-2825
DATE ANALYZED: 01/12/96 VOLUME OF AIR: 350 EFFECTIVE FILTER AREA: 385mm*
FIELD AREA: 0.00785 mm* FIBERS / FIELDS COUNTED: 4/100
FIBERS / CC: <.01
Ricky J. Mrgue4r Environmental Analyst
UCTC 04545 Cl - 0000064
TISCO. INC. UNION CARBIDE TEXAS CITY PLANT BUILDING #116
iX - 2825
N
UCTC 04550 Cl - 0000070
TISCO. INC. UNION CARBIDE TEXAS CITY PLANT BUILDING #116
TX- 2825
UCTC 04551 Cl - 0000071
TI SCO AT UNION CARBIDE. TEXAS CITY BUILDING *121 2/20/96 THROUGH 2/22/96
UCTC 04647 Cl- 0000194
TISCO A l UNION 0r IDE . TEXAS CITY BUILDING *79 PIPE PACK. SOUTH SIDE 2/23/96 CONTAINMENT #1 TX-2837
UCTC 04648 Cl- 0000195
rn Ovj
TI SCO AT UNION CARBIDE. TEXAS CITY UILDING #79 PIPE RACK. SOUTH SIDE 723/96 CONTAINMENT #2 TX-2837 337CL048 N
1
UCTC 04649 Cl- 0000196
TI SCO AT UNION CARBIDE. TEXAS CITY
BUILDING *121 THIRD FLOOR 2/23/96 THROUGH 2/28/96 TX-2837
637BG053
837BG052
837BG051
837A07S 837A071 837A065
UCTC 04650 Cl- 0000197