j Water Line | Returns | Steam Rating
No. 1 | Buckwheat
Height Outlets i Chimney Flue A p p ro xim a te
Shipping W e ig h t Return Water Rating
No. 1 Buckwheat
Boilers
Molby Boiler Company Incorporated
Subsidiary of The Universal Pipe and Radiator Company
Molby Magazine-Feed Downdraft-Crossdraft Boilers and Heavy Duty Tank Heaters with Adjustable Side Grate for burning No. 1 Buckwheat Anthracite
GRAYBAR BUILDING, LEXINGTON AVENUE AT 43rd STREET, NEW YORK
Philadelphia Branch 2401 Chestnut Street
Lansdale. Pa. Branch 50 Central Avenue
Chicago Branch 332 S. Michigan Avenue
Highest Medal Award of Merit and Diploma: Sesqui-Centennial.
Philadelphia
Built throughout in accordance with codes of the A.S.M.E.
and the A.S.H.hfV.E.
HE Molby is easy to operate, is self material. These ratings, under the same
Tfeeding, and gives a steady, even conditions, may be used for sized soft coal heat over long periods with low- of the free-burning and non-caking variety. priced No. 1 Buckwheat Anthracite. Also Should larger sizes of good grades of
bums sized free-burning bituminous with Anthracite be used, a given boiler--other
proper chimney draft. Also coke. Maga conditions being the same--would burn
zines need re-filling only once every 12 with equal efficiency, 20 per cent more
to 24 hours. Cast iron sectional con coal. Thus, when such larger sizes are
struction throughout.
regularly used, the ratings shown are
Ratings are based on the assumption increased 20 per cent.
that a good grade of No. 1 Buckwheat
The Molby will heat home--large
Anthracite is to be used and that the apartment house---or commercial building
chimney is of such area, height and tight --having a good chimney, just as success
ness as to produce the required draft; fully and just as easily with low-priced
also that the boiler, mains and connections small coal as ordinary boilers burning the
shall be covered with an . insulating expensive sizes.
Molby Boiler Company, Incorporated
Boilers
SIZES, CAPACITIES. DIMENSIONS AND PRICES
STEAM
STEAM AND WATER
waYer
Number
Steam Vapor
Sire--1 etches
_C jC
113
M C
Jl cn
Number
Water Cipher
26* Series
S-4026 S-5026 5-6026
S-7026 S-8026
Adageo Addieo
Admito Adzo Adelo
48 48 48 48 48
2-3 550
2-3 725
2-3 900 2-3 1125 2-3 1300
31* Series
54 54 54 54 54
41 35'/, 10 2-3 8x12 1890 W-4026
2-3 925
41 42
10 2-3 8x12 2230 W-5026
41 48i/2 10 ?A 8x12 2580 W-6026
2-3 1225 2-3 1525
4i 55
10 2-3 12x12 2950 W-7026
2-3 1900
41 61'/, 10 2-3 12 JK12 3300 W-8026 Docko 2-3 2200
S- 4031 Bugo
54 2-4 1075 62'/, 61 37y, 14 2-3 8x12 3320 W- 4031
2-4 .1825
S- 5031 Uulto
54 2-4 1425 62'/, 61 44
14 2-3 I2x 12 3820 W- 5031
2-4 2425
S- 6031 Bullo
54 2-4 1775 62'/, 61 soy, 14 2-3 12x12 4290 W- 6031
2-4 3000
S- 7031 Buno
54 2-4 2125 62'/, 61 *>v. 14 3-3 12x16 .4690 W- 7031
2-4 3625
*'/,S- 8031 Bulbo
54 2-4 2475 62'/, 61 63'/, 14 3-3 12x 16 5100 W- 8031
S- 9031 Buoyo 54 2-4 2825 62'/, 61
14 3-3 16* 16 5510 W- 9031
2-4 4200 2-4 4825
S-10031 Bungo 54 2-4 3175 62'/2 61 75'/, 14 3-3 16x16 5930 W-I003I Eduxo 2-4 5400
47* Series
S- 5047 Catxo 67V, 2-5 2750 80 75'/, 5C/, 14 2-4 12x16 5990 W- 5047
2-5 4675
S- 6047 Calto 67'/, 2-5 3400 80 75'/, 59
14 2-4 16x16 7150 W- 6047
2-5 5800
S- 7047 Caro
67'/, 3-5 4050 80 75'/, 67'/, 16 3-4 16x16 8310 W- 7047
3-5 6900
S- 8047 Carpo 67'/, 3-5 4700 80 751/, 76
16 3-4 16x20 9500 W- 8047
S- 9047 Caseo 67i/2 3-5 5350 80 75Vi 841/, 18 3-4 16x20 10650 W- 9047
3-5 8050 3-5 9150
S-10047 Cadio <>m 3-5 6000 80 75V? 93
18 4-4 20x20 11840 W-10047
3-5 10300
S-II047 Cabo 67|4 3-5 6650 80 75'/, 101'/, 18 4-4 20x20 13000 W-11047
3-5 11400
"/,S-12047 Cando 67]/, 3-5 7300 80 75'4 110
S-I3047 Camo 67'/, 3-5 7950 80 75'/,
18 4-4 20x24 14150 W-12047
3-5 12500
18 4-4 20x24 15320 W-13047 Fleigo 3-5 13600
Note.--In ordering 26 in. boilers state whether you wish same fitted up with right hand or left hand end to the chimney. Length includes Smoke Box.
Equipment.--Each steam boiler is equipped with a full set steam trimmings (26 in. series, I pressure regu lator; 31 in. and 47 in. senes. 2 pressure regulators.)
Water boilers are furnished with two water temperature regulators, except 26 in. series which are
equipped with one. A complete set of firing and cleaning tools, together with instruction books for setting up and operation, accompany each boiler.
THE cross-sectional views on this and the next page show the construction of the sections and the relative position of the reserve coal in the magazine. Note the downdraft and crossdraft travel of the gases through the fire and into the com bustion chamber.
548
Side grate easily adjustedfor small coal or large coal
LOSS of valuable heat units is im possible because the fuel is added to the draft side of the fire. The air supporting the combustion enters the fire chamber through the ad justable side grate, passes through the incandescent fire and is drawn through the water grate with the gases at a flaming temperature. Airandgases mix upon entering the combustion chaqiber.
549