TECHNICAL r BULLETIN Standard Analytical Methods for Determining TherminoP ' Viscosity Acidity Moisture TECHNICAL BULLETIN O/FF-18 Monsanto OJ.008*8 TOWOLDMON0022214 WATER_PCB-00006683 Standard Analytical Methods for Determining Therminol: Viscosity Acidity Moisture TECHNICAL BULLETIN O/FF-18 *TMhlieantainadharainhta bacanatniadan rattmmandatton tainaaiqrproductIncaMIletwttli any patant. MONSANTO MAKES NO WARRANTIESAS TO THE FITNESS OR MERCHANTABILITY OF ANT PRODUCTS INFERRED TO, in iwranlaa atttohetar) rwalta fiwn raltonca uoan eontalnad Intarmatton ai racommandattona, anddlaetalmaall IWailHy Hi any raaultlnclaaaat damafa." Orgsnic Chtmicob (Kvisioo/800 N. Undbsrgb BW./SL Louis, Missouri 63168 0100659 I TOWOLDMON0022215 WATER_PCB-00006684 STANDARD ANALYTICAL METHOD Product: Pydraul and Therminol fluids Test: Viscosity by Modified Ostwald Viscometer for Transparent and Opaque Liquids SCOPE This method is used to determine the viscosity of the fluids by using a modified Ostwald viscometer and is in accordance with ASTM Standard Test D 445-65, Viscosity of Transparent and Opaque Liquids. Viscosity is determined by measuring the time of flow of a fixed volume of liquid at a given temperature through a calibrated glass capillary instrument using "gravity flow". EQUIPMENT a. Viscometers -- Calibrated glass capillary type, capable of measuring viscosity within repeatable limits. Viscometers such as CannonFenske Routine, Cannon-Manning Semi-Micro, and Cannon-Fenske Opaque in sizes 100, 150, 200 and 300 are recommended. Viscosity Range Size Centistokes ssu 100 8-12 36-66 150 7-28 49-133 200 20-80 98-870 300 50-200 230-930 These items available from Cannon Instrument Co., State College, Pennsylvania. b. Viscometer Holder or Frames -- Any suitable holder to suspend viscometer securely in constant temperature bath in same vertical position as when calibrated. c. Constant Temperature Bath -- Any transparent liquid bath of sufficient depth to cover within 2 cm the sample in the viscometer. Temperature control of the bath must be such to maintain 0.02F. between 60 and 212F over the length of the viscometer. d. Timer -- Any timing device graduated in divisions of not more than 0.2 seconds and having an accuracy of 0.05 percent. Note: Items a through c are available from Cannon Instrument Company in State College, Pennsylvania. 0100860 TOWOLDMON0022216 WATER_PCB-00006685 Safety The Pydraul or Therminol fluids can be irritating to the skin. The vapors of the hot materials can be irritating to the eyes and upper respiratory system. If accidental contact is made with the eyes, flush immediately with large quantities of water and get immediate medical attention. Exercise caution to avoid possible thermal bums through contact with hot materials or equipment. Determination 1. Determine the viscosity of the sample using the following table to determine the proper tube size and bath temperatures: Product Therminol FR Lo-Temp Therminol FR-0 Therminol FR-1 Therminol FR-2 Therminol 55 Therminol 66 Therminol 77 Temperature 100F/37.8C 100F/37.8C 100F/37.8C 100F/37.8C 100F/37.8C 100F/37.8C 100F/37.8*C Tube Series No. 100 100 150 200 200 200 300 Note: Therminol fluids showing increased viscosity as result of decomposition may require next larger size viscometer. 2. Connect the large side of the tube, by means of a piece of rub ber tubing to a water aspirator (vacuum source) for cleaning. 3. Apply gentle suction by means of the aspirator. 4. Place the capillary arm of the tube in a beaker containing ca. 100 ml of filtered benzene and suck the solvent through the tube. 5. Repeat step 4 using ca. 100 ml of filtered acetone. 6. Dry the tube by sucking a gentle stream of dry air through it. Note: If the tube is not completely dean, it will be necessary to repeat Steps 4 and 5. 7. Insert the proper range thermometer in the bath. 8. Maintain the bath at the desired temperature 0.05F. Note: At temperatures of 100F or lower, it may be necessary to circulate cooling water through the coils to maintain the desired temperature. 0100661 TOWOLDMON0022217 WATER_PCB-00006686 9. To the large side arm of the viscometer tube, connect a piece of clean rubber tubing which is connected to the vacuum source. 10. Invert the viscometer tube and place the capillary side into a beaker containing the sample. The sample should be hot enough to be fluid. Note: If the material to be tested is not completely free of residue and suspended solids, it must be filtered. This can be done by placing a 1' x 6* test tube in a 600 ml suction flask. Insert a medium porosity (70 micron) Selas glass crucible into a rubber adapter. Place the adapter in the top of the suction flask with the glass tube extending into the test tube. Filter, by suction, enough of the sample to fill the test tube ca. % full. 11. Using a gentle suction, draw enough sampte to fill both bulbs and into the capillary up to the mark etched on it. 12. Remove the vacuum tubing and return the tube to an upright position. Wipe the outside of the tube to remove any excess sample. 13. Fit the tube in the viscosity tube holder and immerse it in a constant temperature bath to such a level that the top bulb is completely immersed but allowing M" of the tube to protrude above the holder. Adjust the tube to a verticle position by visual inspection. 14. Allow the sample and viscometer tube to come to a temperature equilibrium with the bath. This will require a minimum of 10 minutes. 15. After the tube and sample have attained the bath temperature, draw the sample up to a point ca. 5 mm above the mark between the bulbs using a rubber bulb attached to the capillary arm. 16. Withdraw the rubber bulb and as the meniscus of the liquid passes the upper mark start the stop watch. 17. As the meniscus of the liquid passes the lower mark, stop the stop watch. 18. Record, to the nearest 0.2 second, the time required for the fluid to pass between the upper and lower marks. This is the efflux time. 19. Make a check determination by repeating steps 15 through 18. It is not necessary to refill the viscometer. Efflux times should agree with 0.2%. Calculation VK - Ct where VK " viscosity in centistokes at TF C = tube constant at TF t efflux time in seconds TF Determine Vk to the nearest 0.05 centistokes. 0100862 # TOWOLDMON0022218 WATER_PCB-00006687 Conversion of Centistokes (Cs) to Saybolt Universal Seconds (SUS) Cantiitokts (C) 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Siybslt Universal Inn* (Ut) At HOT. and 1WF. At 210F. 32.6 32.9 34.4 34.7 36.0 36.3 37.6 37.9 39.1 39.4 40.8 41.0 42.4 42.7 6.0 45.6 45.9 7.0 48.8 49.1 8.0 52.1 52.5 9.0 55.5 55.9 10.0 5B.9 59.3 11.0 62.4 62.9 12.0 66.0 66.5 13.0 69.8 70.3 14.0 73.6 74.1 15.0 77.4 77.9 16.0 81.3 81.9 17.0 85.3 85.9 18.0 89.4 90.1 19.0 93.6 94.2 20.0 97.8 96.5 21.0 102.0 102.8 22.0 106.4 107.1 23.0 110.7 111.4 24.0 115.0 115.8 25.0 119.3 120.1 26.0 123.7 124.5 27.0 128.1 129.0 28.0 132.5 133.4 29.0 136.9 137.9 30.0 141.3 142.3 31.0 145.7 146.8 32.0 150.2 151.2 33.0 154.7 155.8 34.0 159.2 160.3 35.0 163.7 164.9 CantisUkas (e) 36.0 37.0 38.0 39.0 40.0 Saybolt Univtrul tsosndi (tut) At 1M8F. and MOT. At 210T. 168.2 169.4 172.7 173.9 177.3 178.5 181.8 183.0 186.3 187.6 41.0 190.8 192.1 42.0 195.3 196.7 43.0 199.8 201.2 44.0 204.4 205.9 45.0 209.1 210.5 46.0 213.7 215.2 47.0 218.3 219.8 48.0 222.9 224.5 49.0 227.5 229.1 50.0 232.1 233.8 51.0 236.7 238.4 52.0 241.3 243.1 53.0 245.6 247.7 54.0 250.6 252.4 55.0 255.2 257.0 56.0 259.8 261.6 57.0 264.4 266.3 58.0 269.1 270.9 59.0 273.7 275.6 60.0 278.3 280.2 61.0 282.9 284.9 62.0 287.5 289.5 63.0 292.2 294.2 64.0 296.8 298.8 65.0 301.4 303.5 66.0 306.0 308.1 67.0 310.6 312.8 68.0 315.3 317.4 69.0 319.9 322.1 70.0 324.4 326.7 Over SUS - Cs SUS - Cs 70.0 X 4.635 X 4.667 VlimtlOwMtllsM, but whkhtit within Hu rtnit liven In thittibie, u outlined by ilnetr tnptlitton. 0X00Bb3 TOWOLDMON0022219 WATER_PCB-00006688 STANDARD ANALYTICAL METHOD Product: Pydraul and Therminol fluids Test: Acidity (mg-KOH/g) or Neutralization Number SCOPE This test for the acidity of the fluid is in accordance with the ASTM Standard Test D664-58, Standard Method of Test for Neutralization Number by Potentiometric Titration. The acid number is determined by dissolving a quantity of the fluid in a mixture of toluene and isopropyl alcohol containing a small amount of water and then titrating potentiometerically with alcoholic potassium hydroxide. A glass indicating electrode and a calomel reference electrode are used in titrating. End points are taken as pH 11. Equipment a. Meter -- Voltmeter or potentiometer with accuracy of plus or minus .005 v, sensitivity of .002 v, and a range of .5 v, such as Beckman Model 96A, Fisher Scientific Model 210, or equivalent. b. Glass Electrode -- Fisher Catalog No. 13-639-1, or equivalent. c. Calomel Electrode -- Sleeve type -- Fisher Catalog No. 13-639-60, or equivalent. d. Stirrer -- Variable -- speed mechanical stirrer of any suitable type. e. Buret -- Fisher Catalog No. 3-847, Size D, or equivalent. f. Beaker -- A 300 ml. beaker made with borosilicate glass. g. Stand -- A suitable stand to support stirrer, electrodes, and buret such that the beaker can be removed without disturbing the as sembly is desirable. Reagents a. Buffer, Nonaqueous Basic -- Add 10 ml of buffer stock solution A to 100 ml. of titration solvent. Use within 1 hour. b. m-Nitrophenol (mol. wt. 139.11), conforming to the following requirements: melting point -- 96 to 97C color -- pale yellow Store in brown glass bottle. c. Buffer Stock Solution A can be made or purchased as desired. Purchased solution available from Fisher Scientific or Micro Essential Laboratory (Brooklyn, New York). A pH 11 buffer is suggested. To make the buffer solution proceed as follows: Accurately weigh 27.8 0.1 g of m-nitrophenol and transfer to a 1-liter volumetric flask containing 100 ml. of isopropyl alcohol. Using a 250 ml. graduated cylinder, add to the flask while con tinuously stirring its contents, 50/Nj 1 ml. of 0.2 N alcoholic KOH solution (Ni being the exact normality of the KOH solution found by standardization). Dilute to the 100 ml. mark with iso- # I 0100864 ^ TOWOLDMON0022220 WATER_PCB-00006689 propyl alcohol, and mix thoroughly. d. Potassium Chloride Electrolyte -- Prepare a saturated solution potassium chloride (KC1) in water. e. Potassium Hydroxide Solution, Standard Alcoholic (0.1N). Add 6 g of potassium hydroxide (KOH) to approximately 1 liter of anhydrous isopropyl alcohol. Boil gently for 10 min. to effect solution. Allow solution to stand for two days and then filter the supematent liquid through a fine sintered -- glass funnel. Store the solution in chemically resistant bottle. Dispense in such a manner that the solution is protected from atmospheric carbon dioxide (C02) by means of a soda lime or soda asbestos guard tube, and such that it does not come into contact with cork, rubber, or sapon ified stop-cock grease. Standardize frequently enough to detect normality changes of 0.0005. f. Potassium Hydroxide Solution, Standard Alcoholic (0.2N) -- Pre pare, store and standardize as directed in paragraph (e), but use 12 to 13 g. of KOH to approximately 1 liter of isopropyl alcohol. g. Titration solvent -- add 500 ml of toluene and 5 ml. of water to 495 ml. of anhydrous isopropyl alcohol. The titration solvent should be made up in large quantities, and its blank value deter mined daily by titration prior to use. Preparation of Apparatus Use standard procedures for preparation and maintenance of electrode equipment. Procedure for Acid Number a. Into a 300 ml titration beaker, introduce a weighed quantity of Therminol or Pydraul of about 10 g 0.10 g, and add 125 ml of titration solvent. Make sure all surfaces of the electrode are wiped clean and wetted with electrolyte previous to titration. Place beaker on stand and adjust its position so that the electrodes are about half immersed. Start stirrer, and stir throughout titration at a rate sufficient to produce vigorous agitation without spattering or without stirring air into the solution. b. Fill buret with the 0.1 N alcoholic KOH solution and place the buret into the titrating assembly so that the tip is about 1 inch into the liquid. Record the initial buret and meter (cell potential) readings. Add suitable small portions of 0.1N alcoholic KOH solution and, after waiting until constant potential has been es tablished, record the buret and meter readings. In regions where 0.1 ml. of titration solution causes a change of 0.03 v (corresponding to 0.5 pH units), add 0.05 ml. portions. In regions where changes are less radical, add portions large enough to produce a change equal to, but not greater than 0.03 v. Titrate in this manner to an end-point of pH 11. c. Blank -- For each set of samples, make a blank titration of 125 ml. of titration solvent, adding 0.1N alcoholic KOH solution in 0.05 ml. increments to a meter of pH 11. 0100365 TOWOLDMON0022221 WATER_PCB-00006690 Calculations a. Note the volumes of the titrating solution for both sample and blank used to reach end-point of pH 11. b. Calculate the acid number as follows in mg KOH perg: . , (A-B) X N X 56.1 Acid Number = -------------------------- vv where: A = milliliters of alcoholic KOH solution used to titrate the sample to its end point, B -- volume corresponding to A for the blank titration N = normality of the alcoholic KOH solution, and W = grams of sample. Note: A colorimetric method, ASTM D 974-54, can be used, however, dark colored fluids will sometimes interfere with the colorimetric end points. STANDARD ANALYTICAL METHOD Product: Pydraul & Therminol Fluids Test: Moisture (H*0 content) SCOPE This test for moisture content of the Pydrauls and Therminols is in accordance with the ASTM Standard Test D1744-64, Standard Method oj Test for Water by Karl Fischer Reagent. The water content is determined by titrating the fluid with standard Karl Fischer reagent to an electrometric end point. EQUIPMENT a. Buret -- Fisher Catalogue No. 3-847 Size D, or equivalent. b. Stirrer -- magnetic stirrer. c. Titration Flask -- Fisher Catalogue No. 10-163,500 ml capacity. d. Meter System -- A micro-ammeter circuit can be assembled accord ing to the attached diagram and using the following components: Microammeter -- A dc meter having 0 to 50 micro amp range with internal resistance of 1500 ohms. Battery -- 1.6 volt dry cell. Electrodes -- a one inch long 0.01 to 0.03 inch diameter platinum wire sealed in soft glass tubing with tip extending approximately 0.6 inches. Fill glass tubing with mercury and seal wire lead into top of tubing with collodin. # # 0100866 | TOWOLDMON0022222 WATER_PCB-00006691 Potentiometer -- having resistance of 2000 ohms. A meter circuit can also be purchased. Example: Precision titration No. 68880 or equivalent would be suitable. Attachments can also be purchased to convert PH meters to indicate Karl Fischer end points. Interferences: Free alkali; oxidizing and reducing agents; Mercaptans, certain basic nitrogenous substances, or other materials that react with iodine, interfere. a. Karl Fischer Reagent, Stock Solution -- Can be purchased from Fischer Scientific Catalogue No. SO-K-2; or made as follows: For each liter of solution, dissolve 85 lg of iodine in 27 2 ml of pyridine in dry, glass-stoppered bottle. Add 67 2 ml of methanol (99.9 percent). Cool the mixture in an ice bath to below 3.9C. Bubble gaseous sulfur dioxide (S02) through concentrated sulfuric acid (HtSO, sp. gr. 1.84) into the cooled mixture. Continue the addition of S02 until the volume has increased 50 1 ml. Alternatively, add 50 1 ml freshly drawn liquid S02 in small increments to the precooled mixture in an ice bath. Mix well and set aside for at least 12 hours before using. b. Karl Fischer Reagent, Dilute Solution -- Can be purchased from Fischer Scientific Catalogue No. SO-K-5 or made from stock so lutions as follows: Adjust the strength of the stock solution to a water equivalence of 2 to 8 mg. of water per ml by dilution with pyridine. c. Sample Solvent -- Mix 1 volume methanol with 8 volumes of chloroform. Standardization of Karl Fischer Reagent: a. Add 50 ml. of the sample solvent to a clean, dry titration flask. Insert the stopper and adjust stirrer to give a smooth stirring action. Turn on the indicating circuit and adjust potentiometer to give a reference point with approximately l^a of current flowing. Add Karl Fischer reagent in suitable amounts to the solvent to cause the needle to deflect from the reference. The end point is reached when after the addition of a single drop of reagent, the needle remains defected at least l^a from the reference point for at least SO seconds. 0100867 TOWOLDMON0022223 WATER_PCB-00006692 b. To the solution in the titration flask add carefully, from a weighing pipet previously weighed to the nearest 0.1 mg., 1 drop of distilled water. Stopper the flask and reweigh the weighing pipet. Titrate to the end point as described in the above paragraph. c. Calculate the water equivalence of the Karl Fischer reagent as follows: where: F = water equivalence of Karl Fischer reagent, in milligrams per milliliter, W -- milligrams of water added, and T milliliters of reagent required for the titration of the added water. .Procedure: a. Add 50 ml. of solvent to the titration flask and titrate with the standardized Karl Fischer reagent to the end point as described in paragraph (a) of the previous section. Stopper the sample inlet tube as quickly as possible in order to prevent absorption of mois ture from the atmosphere. b. Weigh approximately 50 ml of the fluid and add to the titrating flask in any convenient manner. c. Titrate the fluid to the end point as described above. Record the milliliters of reagent used. Calculation: Calculate the water content of the fluid as follows: where: C F 1000 W water, ppm = CF X 1000 W milliters of reagent required for titration of the Therminol or Pydraul, water equivalence in milligrams of water per milliliter, factor for converting to parts per million, and grams of sample used. # 0100868 | TOWOLDMON0022224 WATER_PCB-00006693 Test toe Water in Liquid Petroleum Products (D 1744) 0100869 TOWOLDMON0022225 WATER_PCB-00006694 r \ e :DISTRICT SALES OFFICES ALL DIVISIONS AKRON, OHIO 44313 260 Springtide Drive Montrose Development Perk Tel. (216)666-4111 ATLANTA GEORGIA 30326 Lenox Towers Best 3400 Peeehtree Rd. N. B. -- Suite 1711 Tel. (404) 677-2260 BOSTON, MASSACHUSETTS 02149 Everett Stetlon Tel. (617) 397-6010 : Additional District Offices ere maintained by: : Agrlenltwal Division ALLENTOWN, PENNSYLVANIA 18104 Park Profeeaional Building 2200 Hamilton Strut T#l. (216) 437-5471 DECATUR, ILLINOIS 02523 207 Decatur Profaralonal Building 363 South Main Strut T#l. (217) 423-5031 : DES MOINES, IOWA 60310 312 Marla Hiy Tower Tel. (616) 276-8603 CHICAGO. ILLINOIS 3168 Dee Pieines Ave. FREMONT, NEBRASKA 68026 150 South Main Strut Tel. (402) 727-1230 Dee Pieines, Illinois 60018 Tel. (312) 296-6688 CINCINNATIr OHIO 45206 1601 Medlson Rood Tel. (613) 761 6707 INOIANAPOLIS. INDIANA 46206 Suite 216.4000 Meadowa Drive Building Tel. (317) 647-9146 : KANSAS CITY, MISSOURI 64133 701 Blue Ridge Tower 4240 Blue Ridge Boulevard Tel. (816) 363-8060 LULING, LOUISIANA 70070 DETROIT, MICHIGAN 43235 600 Northland Towers Best Tel. (313) 357-0910 HONOLULU, HAWAII 96812 P. O. Box 174 Tel. (504) 784-6263 MANKATO, MINNESOTA 66001 111 MadiionEast Tel. (607) 387-3406 MEMPHIS, TENNESSEE 36104 205 Pec/fie Internetlonel Bldg. 677 Ale Moene Bfvd., P. 0. Box 3824 Tel. (808) 631-2744 HOUSTON. TEXAS 77027 1301 Post Oek Tower 6051 Westbeimer Roed : 303 Union Plan Building 1636 Union Avanua Tal. (901) 278-7811 : MUSCATINE, IOWA 52761 P. 0. Box 473 Tel. (319) 263-1331 : Hydrocarbon* ft Polymer* Oivision-Lisn Oil Tel. (713) 621-9560 LOS ANGELES. CALIFORNIA 90022 EL DORADO, ARKANSAS 71730 Lion Oil Building Tel. (601)863-3111 6670 B. F/otHIa St. Tel. (213) 723-2492 NEW ENGLAND AREA Hydrocarbons 6 Polymers Dlv. : JACKSON, MISSISSIPPI 39209 P. 0. Box 10937, Weftland Station : Tal. (601) 352-3648 N. LITTLE ROCK, ARKANSAS 72119 410 Weet 8th Street P. 0. Sox 5621 Tel. (601) 376-2437 :730 Worcester St., Indian Orchard. Mess. 01051 Tel. (413) 768-6911 MEMPHIS, TENNESSEE 38113 1023 Rlvomkto Orivo. P. 0. Box 13248 Plastic Products 6 Resins Div. P. 0. Box 2130. Springfield. Mess. 01101 Tel. (413) 788-6911 NEW YORK, NEW YORK 10017 277 Perk Avenue Tel. (901) 946-4451 ! Plastic Product* ft Rcsiitc Divician : EUGENE. OREGON 87401 P. 0. Box 1819 i 866 Seneca Road Tel. (603) 342-7201 Tel. (212) 922-4111 KENILWORTH, NEW JERSEY 07033 North Seventh St & Monro* Ave. ST. LOUIS. MISSOURI 63166 Tel. (201) 276-2900 BOON. Lindbergh Bfvd. Tel. (314) 694-1000 SAN FRANCISCO BAY AREA 2710 Lafayette, Santa Clara, Calif. 9S0S2 Tat. (408) 243-0414 SEATTLEWASHINGTON 98121 Textiles Division ATLANTA, GEORGIA 30303 Atlanta Marehandiea Mart 240 Peaohtru $t,, N. W. Tal. (404) 577-2260 CHARLOTTE. NORTH CAROLINA 26210 6230 Falrview Road, Suita 400 Tal. (704) 364-0110 2112 Third Avanua Tel. (206) 622-4203 GREENVILLE, SOUTH CAROLINA 29606 McAileter Plaza P. O. Box 5564, Station B WILMINGTON, DELAWARE 19803 2006 Concord Pike, Fairfax Tel. (302) 668-6531 Tal. (803) 239-9171 NEW YORK, NEW YORK 10001 360 Fifth Ave. Tel. (212) 656-5100 Vn MONSANTO. 800 N. LINDBERGH BUD., ST. LOUIS, MISSOURI 631SB J3/70 'I 0100670 a>. 2-3016-0270-6 L1THO IN U.S.A. I TOWOLDMON0022226 WATER_PCB-00006695 0100071 Monsanto SOB N. LINDBERGH BLVD., ST. LOUIS. MISSOURI S3ISS m. i' , TOWOLDMON0022227 WATER_PCB-00006696