Document YGn402raBa1rXnmerjY4mx3by
Heating and Air Conditioning Systems
Leader Boiler and Heater Company
176 West Adams Street, Chicago, Illinois
"THE KOOLSTACK LINE"--Oil and Gas Fired Domestic Heating Boilers; Oil and Gas Fired Industrial Boilers; Oil and Gas Fired Warm Air Furnaces; Economizers for Oil
Burners; Koolstack Air Conditioner.
SUMMERAIR FURNACES--For Oil or Gas
With the idea firmly in mind, that a successful heating unit
is the one especially designed for the purpose for which it is to
be used, this company has had extremely successful experience
with the Koolstack line of Steam and Hot Water Boilers, fired
with gas (either natural or manufactured) or fired with oil.
The Summerair Furnace, aside from the casing, is a
complete steel unit, electrically welded at all joints and free
from any possibility of gas leaks. The furnace itself has.been
raised from the floor to allow the utmost circulation of air.
Because of their ease of installation they can be selected for
replacement work as well as for new jobs.
Other outstanding features of Summerair Furnaces follow:
The counter-flow principle of heating the cold air in the
tubes and around the economizer section.
Equipped with our patented automatic chimney tem
perature control damper.
Scientifically designed and laboratory tested to present a minimum resistance to the natural flow of cold air through the unit.
Summerair Furnace equipped with gas burner
Entire design is circular in type, providing unrestrained heating action and easy
installation of furnace outlets.
Casing is provided with a radiant plate which greatly reduces casing loss.
Can be furnished with Blowers, Filters and Humidifiers.
\ """
Summerair Furnaces are made in three models. Heating surfaces from 83 sq. ft. to
108 sq. ft.; casing diameter from 36 in. to 44 in.; number of tubes from 8 to 12; height of
flue cap 59 in. to 61 in. Send for bulletin giving full data.
` `KOOLSTACK' '--Air Conditioner
Koolstack Air Conditioner has beeri designed to meet a demand for an economical,
serviceable and efficient home air conditioning installation for steam, vapor or hot water
boilers and warm air furnaces, when converted from coal to oil burning.
Koolstack Air Conditioner consists of four sub-units combined into one instal
lation. Each unit has been already proved efficient and the combination has been
tested thoroughly under actual working conditions.
The Koolstack Air Conditioner has been developed with a combination of ap
pliances for utilizing the waste heat which would otherwise pass up the stack, filtering the
air content and providing humidification with mechanical circulation.
The unit can be installed on any existing oil burning plant
without inconvenience or interruption in service. It occupies
very little space, needing a floor space twenty inches by forty
inches only. If more space is available the blower and filter
cabinet can be installed as illustrated or it may be suspended
above or near the heating plant.
Specifications
Economizer--Casing. Diameter, 20'. Casing Height, 58'. Eco nomizer Section Diameter, 16'. Economizer Section Height, 48'. Tubes, Seven, each 4' in diameter. Flue Connection. 10'. Fifty sq. ft. of heat ing surface. Will deliver 20,000 to 40,000 B.t.u. per hour depending upon the temperature and volume of flue gases. Upper head is Cast-Iron and acts as Vaporizing pan.
Blower--Type, 4' x 8' Multi-blade. Motor, Standard % horse power, 60 cycle, 1140 R.p.m., capacity about 700 cubic feet per minute. With 1750 R.p.m. capacity 1100 cubic, feet per minute. Other than Standard motor at extra charge according to manufacturer's prices.
Filter--Oil Type, 16' x 25'. Capacity, 800 cubic feet per minute.
Humidifier--Furnished with an adjustable valve, four feet of K* , copper tubing, connector for H " or $4 ' water pipe and main shut-off valve.
684
Heating and Air Conditioning Systems
HE MjyER
PeoriaJllinois
Manufacturers of Domestic Heating and Air Conditioning Units for Coal,
Gas and Oil Burning
Branches and Distributors
Kansas City, Mo. Omaha, Neb. Green Bay. Wis. Pittsburgh, Pa. New Orleans, La. Detroit, Mich. St. Louis. Mo. San Francisco, Calif.
The Weir Conditioned-Air Unit for coal or oil burning, with the Weir Steel Furnace as its basis, is, as its name implies, a complete unit for conditioning the air in the home with respect to temperature, humid ity, and air-cleansing. Casing is double-walled and finished in blue crinkle. Equipment includes thermostatic draft and damper reg ulator with limit con trol, automatic hu midifier, air filters and centrifugal blower for mechanical circu lation, with bonnet control. (Refer to table below for data on installations for gravity as well as mechanical circulation.)
Grate No. Surface
(Sq Ft.)
Ratio Htg. to Grate Surface
Smoke Outlet Diam. (In.)
Gravity Circulation
Casing Dimen.
' Round Rect'lar
(In.)
(In.)
Rated Output
At Reg. Pipe Area (Btu/Hr.) (Sq. In.)
Fan Circulation
Casing ' - Dimen.
(In.)
Air Rated Output Delivery at register
(C.F.M.) (Btu/Hr.)
621 1 26
41 2
9 48
54,400
400
624 1.78
33.9
10
52
51x49
73,600
541
51x102
1200
92,000
626 2 32
29.2
10
54
55x51
94,100 .
692
52x103
1600
118,000
630 3.08
26.4
10
58 61x57 119,000 875
54x111
2000
148,000
633 ' 3.82
22.7
10
65
61x63 138,000
1015
57x117
2300
172,000
636 4.74
19.4
10
67
61x66 160,000
1180 - 57x123
2700
200,000
540 6.25
19.3
12
60x106
4000
264,000
544 7.60
18.5
12
64x114
5000
316,000
The Meyer Gas Fired Air-Conditioner automatically provides complete "conditioned-air." It is as attractive in appearance as it is compact and efficient. -Heating section of heavy gauge welded steel, gas- and fume-tight construc tion; casing thoroughly insulated and finished in blue crinkle. Equipment also includes specially designed auto matic humidifier (which may be pro vided with room control if desired), renewable filters,, centrifugal blower with bonnet control, motor gas valve, gas-electric safety pilot with hand valve, pressure regulator, hand shut-off valves, and draft hood.
Output
Input
No.
at Bonnet
at Burner
(Btu/Hr.) (Btu/Hr.)
Gas Cons umptidn
Air
Natural Mfd. Delivery
1000 Btu 550 Btu at 1/4' S.P.
(C.F.H.) (C.F.H.) (C.F.M.)
Motor Size (HP).
Vent. Diam. (In.)
General Dimensions
Width Length Height
(In.)
(In.)
(In.)
Approx. Shipping Weight
(Lb.)
I-B 72,500 2-B 145.000 3-B 217,500 4-B 290,000 5-B 362,500
88,000 176,000 264,000 352,000 440,000
88 176 264
352 440
160 1000
/6
320 2000
1/3
480
3000
'A
640 4000
A
800 5000
V,
4 201/, 7 - 41 8 61 Vl 9 82
10 102'/.
52 52 . 52 52 52
42 42. 42 42 42
600 : MOO 1600 2100 2600
Data od refrigerating equipment for summer cooling, to be used in conjunction with any of the above mechanically circulating systems supplied upon request.
685