Document YGdoJnY8ZzDnY7j94D84yvGBk
* 1
X -79/ 00088
WMiam R Bradley and Associates
EMVfKONUeKTAL HEALTH CONSULTANTS 18 GREEN STREET NEVAEK, N. J. 07102
201 <22*4246
March 8/ * X967
Sprayed Mineral Fiber Manufacturers Association, Suite 2300 One Wall Street New York, New York 10005
Inc.
Attention: Technical Committee
Re: ENVIRONMENTAL HEALTH INVESTIGATION
An environmental health investigation was made for the Sprayed Mineral Fiber Manufacturers Association# Inc., on March 1, 1967 at the United States Mineral Products Company# Stanhope# New Jersey. The area set aside for this study was indoors at a corner of a small space isolated from the rest of the research department's laboratory. The area to be sprayed was a celling space about nine feet above floor le vel and an adjoining wall space. This space was adjacent to a large rollup double door. The door could be opened and a large propeller fan used to air out the space following each test
*u
2- -
.r^:.vK
spray operator held the application nozzle about
five feet from the celling area and five feet from the wall
area which was being sprayed. Air samples for dust were col
lected at head level at about three feet from the operator In
this rather confined area of the building. The products test
ed for airborne dust during application were as follows:
United States Mineral Products Co. (USMP) Cafco Blaze-Shield Type D
Baldwin-Ehret-Hill, Inc. (BEB) Pyxospray Type 1
Smith & Kanzler (s&K)
Spraycraft 1132 Type S
Asbestospray Corporation (Asb.) Asbestospray Type T
The above products were sprayed at a 1:1 ratio of water to dry fiber weight. The application rate was five pounds# ten pounds# and fifteen pounds per minute of dry feed. In the case of Asbestospray# the product was applied from a 16 jet nozzle at five pounds and ten pounds per minute and from a 12 jet nozzle at the same rates. All other products were applied at the three above mentioned rates using the 16 Jet air-water nozzle and the model "AH internal gun without air.
T*>"'
DOST SAMPLE ANALYSIS, .
Teat No.
Water Flow Product fibs ./rain'.)
TVoe of Gun 16 Model Jet **A"
1. Control
2. Asb. 3. Aab. 4. Asb. 5. Asb.
S 10
5 10
X X
6. Control
7. BEH 8. BEH 9. BEH 10. BEH 11. BES 12. BEH
5 10 IS
5 10 IS
X X X
X X X
13.
14. 15. 16. 17. 18. 19.
Control
S&X S&K S&K S&K S&K S&K
5 10 15
5 10 IS
X X X
X X X
20. Control
21. USMP 22. USMP 23. USMP 24. USMP 25. USMP 26. USMP
5 10 IS
5 10 15
X X X
X X X
Millions of Particles per Cubic Poot of Air
1.2
8.0 6.0 9.0 7.0
1.4
15.0 14.0
12.0 21.0
18.0 17.0
1.4
19.0 17.0 16.0 24.0 22.0 20.0
1.4
8.0 7.0 6.0 9.0 8.0 7.0
i^SLd
: \+
Lj
~^I2V
SUMMARY
:crvi
The results of duet studies made la a confined area of
*
*praying mineral fibers shows that the ten pounds and fifteen
pounds per minute flow' rates are less dusty
the five pounds
per minute rate. Also shown is that the combination of air
water In a 16 jet gun results in less airborne dust then does
the use of model MA" gun without air or the 12 jet air and water
combination nozzle.
The control dust levels show that there was no buildup
of dust between sampling tests and the use of different prod*
ucts.
It is conceivable that the Asbestospray product and the
United States Mineral Products product could be sprayed in an
open building under construction using the most favorable air
water gun, product flow rate and water to dry fiber ratio at
airborne dust concentrations near or less then the threshold
limit value of five million particles per cubic foot of air.
The water to dry product ratio for the application of
Baldwin-Shret-Hill and the Smith & Kanzler product is insuff
icient to control both asbestos fibers and clay additives.
WBS/dm
:-*JV