may be an auxiliary gMnline engine or a diesel engim* This engine is usually of large enough capacity so as to be able to drive a generator which provides electric power for operating the evaporator fans. Thus, the air conditioning system is en tirely independent of the main bus power plant and itB aux iliaries. Because the separate engine drive is independent of the main engine, bus engine speed has no effect on the air conditioning and the air conditioning load does not rob power from the Tnnin engine.
The separate engine drive has objections in that it involves initial cost and maintenance of a second engine which is being operated under adverse conditions for best engine perform ance and requires more space and weight allowance. For the above reasons, the installations which are driven from the main engine have found favor in recent years. These systems have the advantage of cutting down on maintenance, initial cost, weight and space allowances, but they do put an added load on the main pngipp.
The main engine drive has a disadvantage in that be^us* the refrigeration compressor is tied to.the main engine speed, the capacity will vary according to the speed at which the main engine is operating. Thus, when the bus is standing tifl and the engine is idling, the capacity is very low. When the bus is operating at high speed, the capacity may be too great. In order to give more uniform refrigeration capacity with speed, various means can be used. One of these is the use of an automatic transmission to maintain the compressor at a fairly constant speed regardless of bus speed. Such a device permits the refrigeration compreskrr to be operated at a rea sonable speed, perhaps 50 to 60 percent of the maximum when the engine is idling in a station.
Another means to regulate capacity is use of a compressor with larger displacement than normal but equipped with automatic capscity control. This arrangement allows use of full compressor displacement when operating at low angina (compressor) rpm and automatic reduction of capacity as the engine (compressor) rpm increases. This type drive requires careful selection of drive ratios and optimum matching of compressor to the main engine.
In addition, a clutch is usually provided to allow the com pressor to be disconnected when required and to eliminate this extra power drain at times when full engine horsepower is re quired. Some installations are provided with a kick-down switch arrangement activated by the throttle pedal. By this device, the air conditioning compressor and usually the drive for the condenser fan is automatically disconnected as long as the accelerator pedal is fully depressed. This added refine ment, of course, requires very careful design of the drive and clutch aa well as the compressor once sudden and very rapid acceleration forces are introduced when the kick-down switch is released.
Several current installations employ hydraulic drive for the condenser fan. The hydraulic pump is mounted on the com pressor dutch housing and driven by belts from the com pressor flywheel while in other installations it is mounted directly on the bus engine. The writers do not know of current bus air-conditioning systems using hydraulic drive for the compressor. However, various truck refrigeration compres sors are driven in this manner, and this type drive for bus air conditioning systems has promise for some applications.
Electric motors are used extensively to power the evapora tor fans for bus air conditioning units. Power requirements are usually within the capacity of the heavy duty generators and alternators used on bus engines. Electric drive for the con denser fans and compressors is not usually considered, due to the high power requirements for these components.
CONTROLS
The usual safety controls such as high-low pressure switch,
oil safety switch and in the case of a separate engine drive, oil
failure switch and high temperature switch are employed.
However, the switch enclosures are weather-proof and dust
tight or the controls are mounted in a separate compartment
for this purpose. In most cases, the capillary lines must be re
placed with flexible hoses to avoid breakage due to vibration.
Operating controls depend on the system used and are quite simple in some cases.
If a separate engine drive is used, start-stop engine and fan
controls are provided for the operator, and temperature is
controlled automatically. This is accomplished by pre-setting
of the compressor capacity control and in some cases by the
automatic water valve on the heating coil which is placed in
series with the oooling coils. Ventilation sir control is usually
pre-set, although in some cases it may be manually adjusted.
Some installations require a separate thermostat to control the cooling system operation. The thermostat can be used to
control a liquid line solenoid valve, a dutch, or the air con
ditioning drive engine in cases where automatic <ngin stop-
start controls are used. The thermostat bulb is usually installed in the air return duct. However, care must be tolrpji to
this bulb from drafts caused by door openings, etc.*
On inter-urban buses, a reheat coil is normally used. This
coil, using hot water from the bus engine, is placed in series with the evaporator on the leaving side. In some cases, it is
necessary to employ booster pumps to supplement the water
pump on the bus engine. Tim coil is usually fitted with an automatic water control valve with the *-nring glgmont of the
automatic valve placed so as to respond to air temperature
over the coil. In addition, a manual control, which can be
used to bypass the automatic control valve, is wmwrimftn em
ployed in order to provide for fast warm-up of the bus in cold weather.
BIBLIOGRAPHY
J. R. Holmes: Air conditioning the automobile (Refrigerating Engineering, July 1954, d. 39)..
J. D. Lovely and R. o. Heym: Automobile air conditioning (Refrigerating Engineering, August 1958, p. 39).
J. R. Holmes: Development of an automobile air conditioning system for under the hood installation (General Motors Engi neering Journal, May-June 1955, p. 44).
M. Kalfus; Air conditioning the automobile (Heating and Ventilating, April 1953, p. 97).
Testing of automotive air conditioning compressors (Auto motive and Aircraft Air Conditioning Forum, Society of Auto motive EngineeraTexas Section, September 15-16, 1958).
C. P. Kelley: The Frigktaire package-type air conditioning unit (General Motors Engineering Journal, July-August 1955, p. 8).
C. D. Mericle: Servicing automobile air conditioners (Air Con ditioning and Refrigeration Netea, June 12, 1955).
P. J. Kent: Automobile air conditioning--progress and prob lems (Heating, Piping and Air Conditioning, December 1953, p. 129).
W. J. Owen: Development of the Cadillac air conditioner (General Motors Engineering Journal, Jurie-July 1953, p. 44).
P. J. Kent: Auto air conditioning (Air Conditioning and Re frigeration News, June 15,1953, p. 18).
T. C. Gleason: What's the future of ventilating and air con ditioning passenger autos? (Refrigerating Engineering, May 1952, p. 482).
Comfort cooling is on the highway (Refrigerating Engi neering, April 1952, p. 364).
J. V. Dobbs: Comfort cooling on the Santa Fe (Refrigerating Engineering, October 1953, p. 1077).
< C. W. McElroy and D. W. Brown: Ways to effectively air con dition rapid transit cars (Refrigerating Engineering, April 1958, p. 42).
G. T. Wilson: Railroad air conditioning (Refrigerating Engineering, May 1943, p. 323).
CHAPTER 18
AIRCRAFT AIR CONDITIONING
Design Conditions, Cabin Air Sources and Distribution, Air-Cyde Refrigeration System, Vapor-Cycle Refrigeration System, Combined Vapor- and A/r-Cyde Refrigeration System, Temperature Control, Cabin Pressurization Control, Cargo Compartments, Supersonic Transports
HE introduction of high speed jet transport airplanesin pressure due to ram effects is appreciable and may be calcu
Tpassenger service has greatly increased the importance of lated from Equations 1 and 2:
aircraft air conditioning in recent years. These aircraft carry
AT, - 0.2APT.
(1)
as many as 100 people at speeds approaching the speed of sound and at altitudes up to 40,000 ft. The baric principles of
tiP, - 3.5 (0.2APP.)
(2)
air conditioning stores, restaurants, homes, etc. are applicable where
to airplanes. However, the equipment must meet additional
tiTr " increase in temperature due to ram effect, Fahrenheit
requirements. It must be compact, lightweight, accessible for quick inspection and servicing, vibration free, and unaffected
degrees. M * Mach number, dimensionless.
by airplane vibration and landing impact. The temperature
T. = absolute static temperature of ambient air, Rankine
control' and pressurization control systems must be capable of responding to rapid changes of ambient temperature and pressure as the airplane climbs and descends.
In older non-pressurized airplanes and in light private
degrees. AP, =* increase in pressure due to ram effect, pounds per square
inch. PM absolute static pressure of ambient air, pounds per
plan**, the air-conditioning systems are comparatively simple, consisting usually of just a beating unit. In faster-than-sound military aircraft the systems are quite complex, with the problems of heat sink, and pressure and temperature control, compounded over those of the present day jet transports.
square inch.
The aoerags increase in airplane skin temperature is generally assumed to be 0.9 of the ram temperature rise.
The cooling and heating loads for.a particular airplane must be determined from a heat transfer study and from an analysis
DESIGN CONDITIONS
Fig. 1 gives a typical design ambient temperature envelope, showing the variation of temperature with altitude for hot, standard, and cold'days- The ground static design tempera tures may be higher or lower than these values depending on the regions in which the airplane may be operated. Normal rate of change during climb and descent is about 10 F deg per min, but rates as high as 30 F deg per min may be en countered.
A recommended design ambient moisture variation with altitude is shown in Fig. 2. The moisture may be taken as high as ISO grains per lb of dry air at sea level for military air craft. The moisture given up by the cabin occupants may be determined from the curves in Chapter 8 of the 1961 Guide And Data Book. This factor is particularly important where
&U or a portion of the cabin air is to be recirculated. In a pressurized aircraft the minimum amount of outdoor
air Sowing into the cabin must be equal to the leakage at the particular differential between cabin and outside pressure. The leakage is made up of: (1) structural leakage through door seals and skin joints, and (2) controlled leakage through galley, toilet, and electronic equipment vents. Practically, the inflow should be a considerable margin above the leakage in order to maintain good pressure control and adequate venti lation. A typical pressure control operating range is shown in Fig. 3, where the upper curve represents the maximum pres sure differential to which the cabin is designed and the bot tom curve represents the maximum cabin altitude which is
comfortable for most passengers. The pressure control sys tem will generally be operated somewhere between these two limits. Airplanes flying at high altitudes must be equipped with an oxygen system for use in case of loss of pressuriza tion.
For high speed aircraft the increase in air temperature and
227
:{