Document YGY5w7Q8DYnOrvBzoyzNj8VeN

FILE NAME: Square D (SQD) DATE: 2014 DOC#: SQD018 DOCUMENT DESCRIPTION: Legal - Deposition of Redfield for Square D App#13 ; Plant EmmauB < Cedar Rapids Huntington Milwaukee ) - R E S U L T S ; ASBESTOS Description Asbestos based pipe wrap^ Usage is minimal, most replaced over years with approved substance. Future disposal will be in accordance with regulations. Motor clutch assembly fiber. Finished fiber-type clutch part. .No work done on part, assembled in finished form. Small quantity, job. If broken part disposed of as everyday trash into trash compactor. LA arc shield. Fiber barrier guard in breaker behind arc stack. No work done on part. Minimal waste into trash compactor. Quin-T cardboard tubing (Parabestos 4500), layer paper and temperature insulator barriers. Wastes involved: shavings and thin strips. Disposed of. with other trash; Quin-T ..has taken airborne samples-no hazards. Winding coils and asbestos washers. Disposed of per regulation. SQDKVR 008665 ) SURVEY Precaufcions/Suggestions Of Action No precautions or measurements. 1) Replace all now .2) Verify P.P.E. to be used in future replacement No precautions or measurements. Sub stitute material being investigated, looks probable. 1} Follow up on substitute 2) Change disposal procedure No precautions. Substitute being investigated, replacement probable. 1) Follow up on substitute 2) Change disposal procedure No other precautions. ''SuBStrtute* cfoftdidfeired "but 'high 'expense. 1) Institute P.P.E. usage 2) Airborne concentration measurement 3) Change disposal procedure All precautions taken. Airborne levels annually. Substitute considered. 1) Follow up on' substitute < SQDKVR 008666 ; ) R E S U L T S ; ASBESTOS SURVEY Plant - `Ma3iSsnsSoStutarri-P\?r * Description Precautidns/Suggestions Of Action Substitute considered. Manufacturer.,states EPA; does,,:ript^consider hazardous-waste as generated-;; No^air- . bo;rne level-check. Yes P.P.E. and - , . 1) Follow up on substitute 2) Check if approved disposal ventilation. .Wastes disposed of'in* site Or.not it 'a 'approved site. Lincoln Plenco 509-120 and 130 flow powder. Used in cold powder compression, screw preheated compression and screw transfer processes. Currently disposed of in landfill. . RCRA reviewing to determine if proper disposal. Airborne concentrations tested quarterly. Employees working with are given annual physicals. Currently testing replacement. 1) Follow up on substitute So rgel-Milwaukee Quinongo bonded paper. .Sheared and wound into transformer coils. 'test'"2/26/80. . Amount o f tttfe'tiMT 120m f t Yes P.P.E. No medical surveillance.. Disposal per state and federal law. Substitute considered. 1) Follow up on substitute 2) Airborne concentration measurement Clearwater Parasbestos core tubes. Usied making coils or multiple winding machine. Disposal of dust and pieces in regular trash. Wot aware of approved waste sites. Statement by manufacturer that resin bound, minimal:dust? i No precautions other than dust mask for those cutting- tubes. Considered replacing but* high- 1} Airborne concentration measurement 2) Additional P.P.E. or ventilation 3) Change in disposal procedure - Page 2 . . Plant Spokane * R E S U t T S ; ASBESTOS Description Asbestos blankets. To protect core and coil assemblies during welding, Disposed per normal waste. Blanket life - two months. Raleigh Sorgel-Oshkosh Phenalic or melamine cold molded parts with asbestos filler. Assembled into finished devices or part of parts kit. .90% of parts are spare parts for obsolete devices. No waste. If totally enclosed, no danger. Quintex-SF layer insulation for transformer coils; Cut to length for insertion by winders in coil winding process. Wastes in sealed bags to landfill, - i fi/Ol'. mac , SQDKVR 008667 SURVEY Precautlons/Suggestions Of Action No precautions. Substitute consideration in process. 1) Follow up on substitute 2) Institute P.P.E. use 3) Change in disposal procedure Suppliers of "active" part numbers seeking replacements. No action. Airborne levels tested 3/31/77. No precautions. Sorgel-Milwaukee con sidering substitute which would remove asbestos from Oshkosh. Cutting area dusted and wiped monthly. 1) Follow up on substitute 2) Airborne concentration measurement 31. Institute use of P.P.E., ventilation 4) Check if approved disposal method/site Page 3