Document YGG3v4qDwdZzJg6xVRNzNorK8
582
CHAPTER 27
. 1950Guide
. Solution. In figuring the heat loss from-Equation 2, it is necessary-to first make an
assumption for the outer surface temperature h and the temperature between the diatomaceous silica and 85 per cent magnesia insulation, so that the mean tempera ture of each material can be obtained and the thermal conductivity corresponding to
the mean temperature of each material substituted in the formula. First assume an
outer surface temperature of 140 F and a temperature of 570 F between the two materials corresponding to a mean temperature of (1200 + 570) + 2 or 885 F for the diatomaceous silica and (570 + 140)'-s- 2 or 355 F for the 85 per cent magnesia insula
tion. The conductivities of these two materials at mean temperatures of 885 and 355 F, interpolated from Table 6, are 0.865 and 0.5 Btu, respectively.
Pipe Insulation
583
is (1200 -- 610) = 590 F. Since a temperature of 570 F between the twomaterials was
assumed, it is obvious that a temperature closer to 590; or for instance 586 F may be selected. The mean temperatures of the two insulations corresponding to-the new assumptions are (1200 + 586) -1- 2 = 893 and (586 + 138) -5- 2 = 362, and the inter
polated conductivities corresponding to the new mean temperatures are 0.87 and 0.505 for the diatomaceous silica and 85 per cent magnesia, respectively. By sub
stituting in Equation 2:
1200 - 138 5.36 2.29
1062 = 99.3 Btu.
6.16 + 4.53
0.87 + 0.505
Again referring to Fig. 4, it is seen that the temperature drop from the outer sur
face of the insulation to the surrounding air for a heat loss of 99.3 Btu = 58 F, which
corresponds to the surface temperature of 138 F last assumed. The temperature drop through the diatomaceous silica, is 99.3 X 6.16 = 612 F, corresponding to a
temperature of 588 F between the two materials, which checks very closely with the temperature of 585 F last assumed. The heat:loss is.therefore 99.3 X 8.312 3.312 or 249 Btu per sq ft of pipe surface. Since the surface area per linear foot of 6-in.
pipe is 1.734 sq ft (Table 3), the heat loss per linear foot of pipe will be 249 X 1.734
= 432 Btu per hr.
The rate of heat loss from a surface maintained at constant temperature
is greatly increased by air circulation over the surface. In the case of
well-insulated surfaces, the increases in losses due to.air velocity are very
small as compared with increases from bare surfaces, because of -the fact
that air flowing over the surface of the insulation can increase only the
conductance of heat from surface to air, and cannot change the internal
conductance of the insulation itself. The maximum increase in heat loss
due to air velocity ranges from about 15 per cent in the case of 1-in. thick
insulation, to about 5 per cent in the case of 3-in. thick insulation, pro
vided that the insulation is thoroughly sealed so that air can flow only
over the surface. If the conditions are such that the air may circulate
through cracks and crevices in the insulation, the increases may be far
greater than those given. Therefore, it is essential that insulation be
applied in such a manner that air circulation within it, or between it and
Fig.. 4.' Heat Loss from Canvas-Covebed Cylindrical Surfaces of
the pipe, is avoided.
Various Diameters
Fig. 4 shows the loss of heat from canvas-covered, cylindrical surfaces
of various outside diameters when the surface to air. temperature difference
These values are substituted in Equation 2 and a-trial calculation made. For a
is low. The data are from tests made at Mellon Institute.
nominal 6-in.steel pipe r, = 3.312, r, = 6.312 and r, = 8.312 then,
The frequent practice of omitting insulation on that portion of a pipe
g, 1200 - 140
' 6.312
8.312
8.312 log.
8.312 log.
3.312
6.312
1060 = 98.3 Btu.
6.2 + 4.58
which passes through a masonry wall, Or which may be in contact with other metals, should be avoided. Physical contact between the pipe surface and other structural materials of high thermal conductivity will result in heat transfer much greater than that shown in Tables 1 and 2
0.865
0.5
for transfer from bare pipe to air. The saving due to use of insulation on piping :is illustrated in Example 4.
The temperature drop from the outer surface of the insulation to the surrounding
air for a heat loss of 98.3 Btu is found from Fig. 4 to be 57 F for a l6-in. O.D. cylin
drical surface, or 57 + 80 F room temperature = 137 F surface temperature.;. Since a
surface temperature of 140 F was assumed, it' is evident that' a temperature closer to
137.F,or* for instance, 138.F should be used for recalculation:
- . .-
Example 4. If the steam line given in Examples t and S is covered with I in. thick 85 per cent magnesia, determine the resulting total annual loss through the insulation.
Also compute the monetary value of the annual saving and the percentage of saving over the heat loss from the bare pipe.
Solution. By referring to Fig. 1, the coefficient for 1 in. magnesia on a 2-in. pipe is
1200 - 138 98.4 Btu.
6.2 + 4.58
found to be 0.300 Btu per (hr) (linear ft-of pipe) (deg temperature difference) at a temperature difference of 169-4 F. The total hourly loss per linear foot of pipe will,
then be 0.300 X 169.4 =>-50.8 Btu. The total annual loss through the insulation =
50.8 X 165 (linear ft) X 4000 (hr) = 33,500 Mb. The annual bare pipe loss as deter
Since'the temperature'drop through each material isequal to the'heat flow times the
mined in the solution of Example 1 was found to be 181,600 Mb! The saving due to
actual resistance of each material, the temperature drop through the-diatomaceous
insulation is then 181,600 -- 33,500 = 148,100 Mb per year.
i silica is 98.4 X 6.2 = 610 F, or the temperature between the two insulating materials
From the solution of Example S, it was found that the heat supplied to the system