Document YGBONmYpJ9vYepp5xdwpGrgBy
DATE: SUBJECT: FROM: THRU: TO:
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGIONS
77 WEST JACKSON BOULEYARD CHICAGO, ILLINOIS 60604
DEC 17 2.ll18
CLEAN AIR ACT INSPECTION REPORT Three Brothers Laundry, Chicago, Illinois
Scott Connolly, Environmental Engineer AECAB (IL/IN)
Nathan Frank, Section Chief AECAB (IL/IN)
File
BASIC INFORMATION
Facility Name: Three Brothers Laundry
Facility Location: 2643 West 19th Street, Chicago, Illinois
Date of Inspection: December 11, 2018
EPA Inspector: 1. Scott Connolly, Environmental Engineer
Other Attendees 1. Nick Patel, Manager/Owner, Three Brothers Laundry 2. Nathan Frank, Section Chief, EPA
Contact Email Address: threebrotherslaundry@gmail.com
Purpose of Inspection: To determine compliance with the Clean Air Act and to address citizen complaints.
Facility Type: Dry cleaning and laundry services
Regulations Central to Inspection: 40 C.F.R. Part 63, Subpart M-National Perchloroethylene Air Emissions Standards for Dry Cleaning Facilities
Arrival Time: 9:10 am Departure Time: 9:50 am
Inspection Type: IZI Unannounced Inspection Announced Inspection
OPENING CONFERENCE
IZI Credentials Presented IZI CBI warning to facility provided
The following information was obtained verbally from Nick Patel unless otherwise noted.
Process Description: The facility operates as an industrial laundromat that processes mostly hotel laundry. The facility operates up to 12 hours per day, 7 days per week, depending on customer orders. Pillows cases, clothing and smaller items are washed in one of three single load washers. Sheets, towels and other linens are washed in a multi-stage washing machine that can process up to 30,000 pounds of laundry a day. Cleaning soaps and chemicals are withdrawn directly from storage by a system of pumps and are added to the machine in premeasured amounts. The multi-stage washing machine has two vents that vent directly out the roof. Washed linens exit the multi-stage washer and are automatically pressed to remove water before entering one of four Milnor, natural gaspowered industrial dryers. Each dryer has two stacks, one exhaust and one intake. A fabric filter bag is used to capture lint from the dryers. Dried linens are ironed and folded in automatic machines that use a heating oil system to heat press any wrinkles out. Ironed and folded linens are sent by truck back to customers. The facility operates one perchloroethylene dry cleaning machine that was installed in May 20 I8.
Staff Interview: Mr. Patel stated that the roll iron machines use a wax to maintain consistent products and that the towels and sheet are partially wet when fed into the heated rolls. Mr. Patel stated that ventilation stacks were added to the tunnel washing machine at the request of City of Chicago inspectors because the machine diagrams indicate ventilation location and that the manufacturer typically recommends capping the outlets during normal operations. The facility recently switched to new washing products, manufactured by Ecolab. In July 2018, the facility started operating its relocated a dry-cleaning machine and began dry cleaning operations. The dry-cleaning machine uses perchloroethylene, but Mr. Patel stated that he had no knowledge of any compliance submittals.
TOUR INFORMATION
EPA toured the facility: Yes
Page 2 of 4
Data Collected and Observations: The room containing the ironing machines was visibly hazy at the time of the inspection. The tunnel washing machine and industrial driers were not operating at the time of the inspection. Photos and/or Videos: were taken during the inspection.
A digital image log is contained in Appendix A. Field Measurements: were not taken during this inspection.
RECORDS REVIEW
1. No records were reviewed on site
CLOSING CONFERENCE
Requested documents: I. Safety data sheets for all cleaning materials used at the facility, including the Ecolab products 2. Perchloroethylene (PCE) usage at the facility since dry cleaning operations began. 3. Monthly and/or weekly checks for vapor leaks on the dry-cleaning machine since operations began 4. Specify whether a refrigerated condenser or carbon adsorber is used to control emissions of PCE from the dry-cleaning machine. 5. Notification of Compliance Status
Compliance Assistance: Facility staff were informed that by using perchloroethylene the facility was subject to the National Perchloroethylene Air Emissions Standards for Dry Cleaning Facilities and that the regulations require the facility to submit a notification of compliance to the state.
SIGNATURES
Page 3 of 4
Facility Name: Three Brothers Laundry Facility Location: 2643 West 19th Street, Chicago, Illinois Date of Inspection: December 11, 2018
APPENDICES AND ATTACHMENTS
I.
Appendix A: Digital Image Log
Page 4 of 4
Facility Name: Three Brothers Laundry Facility Location: 2643 West 19th Street, Chicago, Illinois Date of Inspection: December 11, 2018
APPENDIX A: DIGITAL IMAGE LOG
1. Inspector Name: Scott Connolly
3. Company/Facility Name: Three Brothers Laundry
5. Number oflmages:
4
2. Date of Inspection:
December 11, 2018
4. Street Address, City, State:
2643 West 19th Street, Chicago, Illinois
6. Archival Record Location:
https://usepamy.sharepoint.com/:f:/g/personal/connolly_scott_epa_gov/El lXl ZzKgKpEi-73dcTal i8B8tIZKqcOxb41EFa8pCcqZw?e=kFf924
Image Number 1 2 3
File Name
PCl 10001.JPG PCl 10002.JPG PC 110003 .JPG
4
PCl 10004.JPG
Date and Time
12/11/2018 9:25 12/11/2018 9:26 12/11/2018 9:30
12/11/2018 9:30
Latitude and Longitude Description of Image
Data Not Available Data Not Available Data Not Available
Data Not Available
Dry cleaning machine (front) Dry cleaning machine (back) Out of range valve on dry cleaning machine Control Panel on front of dry cleaning machine
Appendices Page 1 of 1