A-C MOTOR CONTROL CENTERS-MNiTROL 3 Pole Combination Starters with Circuit Breakers
Ogu
0
WHEN ORDERING SPECIFY
I Class of construction I and type of wiring
[ Motor control center [ layout
CONTROL CENTER Layout
.... i'i
Catalog number, voltage
jj A convenient printed form for pre
frequency and horsepower !] paring motor control center layouts
of individual units
;; and presenting ordering informa
Heater coils for individual
jj tion may be obtained from your
units, see index page 281. j'> Cutler-Hammer office.
@
I 1 ouJir
1 ccujZ ! o os
tllf?'
W-fh
-
O 1-- z 8'. i >
2 o o
z :82
OS <
. z ivrj ooS^c* os h- -- O US cj o_
(For checking list, see page 248.)
SINGLE SPEED
Type and Cat. No.
Maximum H.P. Ratings 3 Phase, 60 Cycles
208/220 440-550
Volts
Volts
m 10
NEMA Size
1
Circuit Breaker
Type
CLASS 1
Type A
Type B
FULL VOLTAGE
F, FA or EH
$248.
$282.
Price
Type C
CLASS II
Type B
Type C
$327.
$310.
$355.
Extra Space
$80.
NonReversing
15 30
9818
50 . 100
200
V/z
25 50
100 200 400
10
2 3
a4 05 06
1
f F
JA or.KA LA
- MA F, FA or EH
308. 477.
911. 1846. 3177. $387.
344. 519.
987. 01926. 3323.
$431.
399. 594.
1062. 2001. 3443.
$506.
378. 571.
0 1086. 2119. Q 3655.
$474.
433. 646.
1161. 02194. 3775.
"$549.
80. 160.
160. 240: 400. $160.
Reversing ' 9828
15 30 50 100
NonReversing
9836
15 30 60 100
NonReversing
Closed Transition
9838
15
25 30
...
50 ...
75 100 ...
25 50 100 200
2 3 4 05
F
F JA or KA
LA
5Q9. 744. 1427. 2674.
555. _ 796. 1513.
02764.
640. 891. 1608.
2859.
611. 876! 1664.
3031.
696. 971. 01759.
3126.
160. 240. 320. 320.
REDUCED VOLTAGE--TWO STEP--PART WINDING--STAR CONNECTED MOTORS
20 50 100 200
1PW 2PW 3PW 4PW
F F JA or KA LA
$594. 788.
1166. 2096.
$654. 854.
1242. 02222.
$734. 954.
1362. 02342.
$719. 939.
1366. 02444.
$799. 1039. 1486. O 2564.
$160. 240. 320. 400.
REDUCED VOLTAGE--AUTO TRANSFORMER TYPE
25 ' ...
30 50 ... 100 ... ... 150 200
2 3 04
05
F F JA or KA
LA
$1027.
1127. 1170. 1194.
2029. 2053.
3184. 3340. 3256. 3534.
$1069.
1169. 1212. 1236.
2105. 2129. .
3264. 3420. 0 3336. 3614.
$1144.
1244. 1287. 1311.
Q 2180. 2204.
3339. 03495. 03411. 0 3689.
$1176.
1286. 1333. 1360. 2316.
2342.
3590. 3762. 0 3670.. 3975.
$1251.
1361. 1408. 1435.
0 2391. 2417.
3665. 3837. 3745. 4050.
$320.
320. 320. 320.
400. 400.
400. 400. 400. 400.
Dimensions in Inches
WH
Space Factor
20 m or 14
20 14 20 Wi or
Zo 20 28 20 42 30 70
20 18% or 28
20 28 20 42 20 42 20 70
1
1 2
2 3 5 2
2 3 3 5
20 28 20 28 20 42 20 56
2 2 3 4
20 42 20 56 20 70
3 4 5
30 70
5
8[<sS5s.
ce0O2 Qii^.;
LU U. < J-- C'-O
< >
O
TWO SPEED - FULL VOLTAGE NON-REVERSING
Max. H.P. Ratings 3 Ph. 60 Cy.
Type aqd Cat. trio.
Separate Winding
Type Motdrs
9857
Constant or Variable Torque
Constant Horsepower
208/220 440-550 208/220 440-550
Volts
Volts
Volts
Volts
m. 10 3
15 25 10
5 20
30 50 20 40
50 100 30 60
100 200
75 150
NEMA Size
1 2 3 4 05
Circuit Breaker
Type
F F. F JA or KA LA
Class 1
Type A
$464. 601. 826.
1593. 3107.
Type B
$524. 667. 902.
1719. 3241.
Reconnectable Winding
Type Motors
966
IVi
15 30
50 100
10 25 50 100 200
3 10 20 30 75
O Stationary units, not plug-in type.
Load terminal blocks not provided.
5i
20 2 40 3 60 4
150 05
F F F JA or KA LA
$506. 681. 934.
1957. 3496.
$566. 747.
1010. 2083. 3632.
Type EH circuit breaker in 480 volts max.; type FA circuit breaker magnetic trip only
Price
Class 11
Type C
$604. 767. 1022.
1839. 3361.
Type B
$576. 734. 992.
1891. 3564.
Type C
$656. 834. 1112.
2011. 3685.
$646. 847.
1130. 2203.
Q3752.
$623. 822.
1111. 2291.
3995.
$703. 922.
1231. 2411.
4115.
CUTLER-HAMMER
244
Extra Space
$160. 160. 240. 400. 400.
$160. 160. 240. 400. 400.
Dimensions in Inches
Space Factor
WH
20 28 20 28 20 42 20 42 20 70
2 2 3 3 5
20 28 20 28 20 42 20 56 30 70
2 2 3 4 5
DISCOUNT SCHEDULE ICD-2