Document YG3GLVLzpqMQN23j2B6YbYv3y

'V frt K ASARCO PLAINTIFF'S EXHIBIT is Department of Environmental Sciences M. O. Varner Manager September 11, 1980 .Jt - 'LW .. <3? WCF .. & Mr. George Sidlo CAPCO Pipe Co. - Ragland Plant .L; A I have reviewed the results of the special asbestos sampling conducted at the Ragland Plant during June 17-18, 1980. These results were reported to you previously via telephone by Frank Burton. These results merit some comments. ' Considerable variation between results of samples taken at the same location or on the same worker are evident. The apparent magnitude of samples taken on the dust collector tender during shakedown of the baghouse are considerably lower than other results obtained during normal production conditions, opposite the results one would normally expect under these circumstances. In addition, it is quite puzzling to note that the results of the concommitant samples taken on Mr. Daffron (while wearing the Racal A-3 air-purifying system and helmet) would indicate the asbestos concentrations in the breathing zone inside the Racal helmet to be about 245 times that concentration apparent ly measured on the lapel outside the helmet. This is also completely opposite the results one would expect. Mr. Frank Burton has examined the filter cassettes, rechecked the labels, and recounted the fibers on another section of each of the following samples: Name Date Cassette No. Original Value (fibers/cc) Recount of 9/9/80 (fibers/cc) L. Daffron 6/17/80 R-5 6.02 5.23 L. Daffron 6/18/80 R-10 4.53 4.38 L. Daffron L. Daffron Batch Mix Area Batch Mix Area 6/18/80 6/18/80 6/17/80 6/17/80 R-12 R-13 R-9 R-7 <0.022 5.39 <0.015 6.92 <0.022 9.75 <0.015 5.35 Mr. Burton showed these cassettes to the undersigned and we noted some loose particulates (lint-like) in filter cassettes R-5_and R-13, but not in the other cassettes. This leads us to inquire if these samples were possibly inadvertently mis- ASARCO Incorporated 3422 South 700 West, Sal? Lake City. Utah 84119 (801) 262-2459 ASARCO ALV 0000579 2- - labelled or somehow contaminated. In summary, I am at a loss to definitively interpret or explain these results. I recognize, ^ as emphasized by Mr. Burton, that the NIOSH method used to count the fibers has many deficiencies, i.e., is not very reproducible or accurate (see repeat values above), the filters can be easily contaminated even during the analytical procedure, etc. The apparent anomalies observed in these results may be caused by several different factors which cannot be easily isolated. There fore, it is recommended that repeat sampling be given serious consideration. D.O.E.S. stands ready to assist -in any way we can In closing, I want to express my gratitude for the extraordinary southern hospitality shown me during the environmental survey in August at the Ragland Plant. I am impressed by the fine job you and your associates are doing and I look forward to a con tinued beneficial relationship. LDW/cah Attach. cc: SGLeyshock (w. attach.) KWNelson " MOVarner " Lowell D. White, Ph.D. Senior Environmental Scientist r J ASARCO ALV 0000580 HftME S.S. NUMBER ASARCO INC. RAGLAND PERSONAL MONITOR SAMPLING RESULTS < FOR COMPANY USE ONLY) JOB TITLE < RESP. TYPE) 1930 SAMPLING DATE Sc TIME ANAL- COHC'H. SHIFT <MIN.) YSIS Cfi/cc ) JONES 413560044 JONES 418560044 JONES 413560044 JONES 41S560044 DAFFP.ON 420540596 DAFFRON 420540596 DAFFRON 420540596 DAFFRON 420540596 DAFFRON 420540596 DAFFRON 420540596 A/C PRODUCTION .BATCH MIXER 7 6/1 7 D 24 A8B .50 .BATCH MIXER 7 6/17 D 62 ASB .24 .BATCH MIXER 2 6/17 D 67 ASB .72 BATCH MIXER 7 6/17 69 D Ho asbestos fibers found DUST COLLECTOR TEND 6/17 D7 1 56 ASB 6.02 DUST COLLECTOR TEND 7 6/17 57 D- No asbestos fibers found DUST COLLECTOR TEND 7 6/17 59 D Ho asbestos fibers found DUST COLLECTOR TEND 6/18 7D 37 ASB 4.53 DUST `COLLECTOR TEND 7 6/18 36 D No asbestos fibers found DUST COLLECTOR TEND 6/18 7D 30 ASB 5.39 M rI ASARCO ALV 0000581 ASARCO INC. RAGLAND STATIONARY SAMPLER RESULTS <FOR COMPANY USE ONLY) SAMPLE LOCATION I960 DATE SAMPLING TIME ANAL- CONC'N. <MIN.) YSIS <fi/cc ) A/C PRODUCTION BATCH MIX AREA<WHITE ROOM) 6/17 60 ASB 6.92 BATCH NIX AREA<WHITE AREA) 6/17 57 No asbestos fibers found DUST COLLECTOR AREA 6/18 39 ASB .22 DUST COLLECTOR AREA 6/18 57' I. No asbestos fibers found I ASARCO ALV 0000582 NAME S.S. NUMBER ASARCO INC. RAGLAND PERSONAL MONITOR SAMPLING RESULTS (FOR COMPANY USE ONLY) JOB TITLE (RESP. TYPE) 1930 SANPLIHG DATE & TIME ANAL- COHC'H. SHIFT (MIN.) YSIS (Fi/cc ) JONES 418560044 JONES 418560044 JONES 418560044 JONES 418560044 DAFFRON 420540595 DAFFRON 420540596 DAFFRON 420540596 DAFFRON 420540596 DAFr'TN 420540596 DAFFRDH 420540596 A/C PRODUCTION BATCH MIXER 7 6/1? D 24 ASB .50 BATCH MIXER ? 6/1? D 62 ASB .24 BATCH MIXER 2 6/1 67 D ASB .72 BATCH MIXER y 6/1? 69 D Ho asbestos Fibers Found DUST COLLECTOR TEND 6/17 7D 56 ASB 6.02 DUST COLLECTOR TEND 6/1? 5? ?D Ho asbestos Fibers Found DUST COLLECTOR TEND ? 6/17 59 D No asbestos Fibers Found DUST COLLECTOR TEND 6/13 7D 37 ASB 4.53 DUST`COLLECTOR TEND 7 6/13 36 D No asbestos Fibers Found DUST COLLECTOR TEND 6/18 7D 30 ASB 5 .'39 M i ASARCO ALV 0000584