Document YG1nv6Dp1bdLjBrBv0pjo8r4V

74 7(130 PLAINTIFF'S EXHIBIT ANALYTICAL REPORT M'D LAND ANALYTICAL LABORATORIES DOW CHEMICAL U.S.A. D. R. Beaman, 574 R. S. Kolafc, 1602 ACC T. SUMOEB ISUB FUNCTION H. W. TO K. A. Chagnard, Louisiana Div. F. C. Leavitt, 574 B. Crummett, 574 J. J. Leddy, 474 W. Guebert, 52 D. P. Sheetz, 47 LAI. NO. IPROBICM NUMBER G. L. Jewett, 1602 F. P. VanRemoortere,574 C.R.I. - 5 copies 12-19-74 tp-Te--DETERMINATION OF"ASBESTOS IN CELL EFFLUENT USING ATOMIC ABSORPTION ____SPECTROSCOPY---------------------------------------------------------------------------------------------------------------------------------- Introduction Asbestos levels in our chlor-alkali process are being determined by a time consuming electron microscopic technique. H. A. Chagnard, Louisi ana Division, has reported that an elemental analysis for magnesium by atomic absorption spectroscopy can be used to determine asbestos levels in cell effluent. Since a rapid analysis would be desirable for evaluating filtration experiments for asbestos removal from cell efflu ent, we have evaluated this atomic absorption procedure. Safety Cell effluent is a corrosive alkali and hydrochloric and hydrofluoric are corrosive acids. Handling of these materials require the use of eye goggles and protective clothing. Hydrofluoric acid is especially corrosive to tissue and contact with the skin should definitely be avoided at all times. ST028L87U Experimental Three samples each of unfiltered and filtered cell effluent were ob tained from the Analytical Laboratories Microscopy Group. Asbestos contents of all had been determined using an electron microscope coupled with an X-ray fluorescence analyzer. The apparent asbestos content of these samples was then determined with slight modification of the atomic absorption method developed by Chagnard. A detailed description of the method used is as follows. Determination of Asbestos in Cell Effluent 1. Shake sample vigorously, and immediately filter a 100 ml portion of sample through a 47 mm Metricel* 0.45 micron filter. A Millipore* membrane cell filter holder may be used for these filtraitions. This holder or a similar filter holder must be used with a vacuum flask to speed up acid washes. Larger portions are recommended for samples of low asbestos content to increase sensitivity. 2. Wash filter rapidly with 3, 50 ml portions of 0.1 N HC1. (Each portion of acid should pass through the filter in less than ten sec onds to minimize asbestos losses.) SIGNATURE F OR'* M.SOnM'/ * PHONE OUILDING DATE FINISHED HOURS PRHEOSUNLETDS REVIEWED IV ^ o /C .i l Ai/j u/tv 2 ' ST0284875 3. Place the filter disc in the bottom of a 150 ml polyethylene beaker and add 1.0 ml of 48% reagent grade or 55% technical grade hydrofluoric acid. Allow the filter to stand for 30 minutes to dissolve the silica compounds. 4. Add 25 ml of 5% boric acid to the beaker. Swirl the beaker and place it into a shallow water bath about 50C. Allow to stand 15 minutes to inactivate the excess hydrofluoric acid. 5. Add 74 ml of distilled water to the beaker. 6. Repeat above procedure without a sample to obtain a reagent blank. 7. Obtain atomic absorption data using a Perkin Elmer 303 atomic absorption unit (or equivalent) using the 285 my magnesium wave length and an air-acetylene flame. A standard curve should be produced with 0, 0.5, 1.0 and 2.0 micrograms Mg per milliliter standard solutions. This curve will deviate slightly from lin earity above 2.0 yg Mg/ml. The standards should contain the same amount of boric acid and hydrofluoric acid as the samples. 8. Calculate ppm asbestos by multiplying yg Mg/ml in sample by 3.83 (factor for chrysotile asbestos with molecular formula 3MgO-2Si02* 2H20). Results Table I compares the data obtained by the microscopic method with those obtained by atomic absorption. For the microscopic data, the micrograms/milliliter (yg/ml) values were calculated from the million fibers/liter data (MFL). These yg/ml data should be used only for comparison purposes since they are based on an average length-average diameter-known density calculation. Table I - Comparison of Microscopic and Atomic Absorption Measurements of Asbestos in Cell Effluent Sample Unfiltered Asbestos -Microscopy MFL yg/ml Asbestos-Atomic Absorption (a) yg/ml 10/23/74 10/24/74 10/29/74 46,000 35,000 >50,000 0.66 0.60 >1.15 4.4 4.1 2.3 Filtered 10/22/74 10/24/74 10/29/74 96 260 351 0.0005 0.0004 0.0031 0.015 0.007 k <0.02 <0.04 8- u V QJ -<-> a o i--0)t O <u s a S a (U d c d *8 0) 3 T3 01 0) u a> JS *8 E 3 tH 4J o aj CaO a 0ti) 3 ta. CJ JS El eo 3 U S> 3 ST0284876 (Footnotes to Table I) ^Calculated from magnesium content using the formula 3Mg0'2Si02'2H20 for chrysotile asbestos. ^Different sensitivities were obtained for the three filtered cell effluents because 500, 250 and 100 ml sample volumes were used for the different determinations. It can be seen from Table I that samples having higher fiber counts also gave higher magnesium values. Also, the atomic absorption method appears to be a good tool for the determin ation of the efficiency of filtering systems for cell effluents. The time required for the determinations is of the order of 30 minutes per sample when batches of six or more are analyzed. The sensitivity of the atomic absorption method is limited to 0.005 yg/ml of asbestos on a one liter sample due to the mag nesium content of the Metricel* filter pad. The higher asbestos values obtained by atomic absorption are expected since one calculates all acid insoluble magnesium in the sample as chrysotile asbestos. It is known from the microscopy work that many particles present in cell effluent contain magnesium but are not chrysotile. Silicon was determined in the above samples to see if a relation ship existed between silicon content and asbestos. Table II - Asbestos Levels in Cell Effluent As Calculated From Silicon Content Unfiltered 10/23/74 10/24/74 10/29/74 Filtered 10/22/74 10/24/74 10/29/74 Asbestos- uq/ml 21.2 90.7 32.5 <0.05 <0.05 <0.05 Table II demonstrates that there are other forms of silicon other than asbestos in the samples since lower asbestos levels are cal culated from the magnesium data. This is not surprising since sand filters are used in the chlor-alkali process and the electroly sis cells are made of concrete. While a silicon determination could be used to evaluate the efficiency of a filtering operation, it is not as sensitive as the magnesium analysis and is more time consuming. 4 In addition to the six samples of cell effluent, a sample of salt brine from the wells prior to the brine treatment plant was also analyzed and found to contain the equivalent of 0.023 yg/ml of asbestos. Referring back to Table I, it is seen that filtering the cell effluent will reduce the apparent asbestos content to less than that in the incoming brine. Reference H. A. Chagnard, Determination of Asbestos in Aqueous Samples by Atomic Absorption, LAD-AR-74.01. T. A. Hiller Inorganic Analysis Group 1602 Building ' ST0284877