Document YDy27GbZwweERzROw0vM6RQOO
Insulation Underground
H. W. Porter & Co.
INCORPORATED
Newark, New Jersey
Permanent Protection and Insulation for Underground Pipe Lines
BALTIMORE. MD.
CHARLOTTE, N. C.
RICHMOND, VA.
WASHINGTON, D. c.
3%6rm-0-7ifc
ACC uS-AArarr
STEAM
CONDUIT SYSTEMS
For Central Heating--Therm-O-Tile
is a complete conduit system for the per
manent support, protection, and insulation
of underground mains of a central heating
system.
--
Tile Envelope--
Arch tiles are made 6 in. to 24 in. in diame ter, and with 5 different size base tiles they produce 27 different conduit cross sections. Foundation--The base of the system is a thick concrete slab poured directly in the trench bottom, reinforced with steel when installed over a filled or boggy ground. See Figs. 1, 4, 6 and 7. Drainage--The drainage system of the conduit is entirely internal, open to in spection at manholes, and of ample ca pacity to keep the pipe space dry at all times without any possibility of becoming clogged with silt or vegetation. See Figs. 6 and 7.
Insulation--Either sectional pipe cov
ering or Thermobestos waterproof fibre
filling may be used for insulation, as the
insulation space is kept dry at all times
by the internal drain.
'
For single or double
pipe lines, sectional
insulation of econom-
ical thickness is
recommended;
for multiple
pipe lines, a
filler type of
insulation is Fig. ^Pipe Sadife, P,,mils
usually more economical in
full thickness of insulation between pipe and roller.
first cost. See Figs. 6 and 7.
Waterproofing-- Under normal soil
conditions, this conduit is waterproof. If
marshy ground or partially submerged
conditions are encountered, the conduit
may be made completely waterproof by
the use of membrane waterproofing applied
under the slab on a sub-base ana carried
completely over the tile envelope.
Fig. 6--A nchor Block. Fits directly in line with Base Tiles.
Efficiency--The degree of thermal
efficiency secured depends upon the type
and thickness of insulation used. This conduit, due to its sealed air chambers in
the tile and dry insulation space, adds to
the normal efficiency of the insulating material on the pipe lines.
Representatives--Therm-O-Tile is also
Fig. S--Pipe Support for Single Pipe.
Fig. S--Pipe Support for Three Pipes.
Pipe Support--AH pipes are supported
sold and installed locally by Johns-Manville Construction Units.
on cast-iron adjustable supports resting
directly on the concrete base independent
of the tile envelope. Figs. 2, 3, 4, 6 and 7.
Accessibility--All piping is installed before tile is placed, giving complete ac
cessibility for welding, testing and insu
lation. Pipe fitters work on concrete slab
"walkway." Figs. 1 and 4.
Strength--Due to immovable concrete
base and arch construction of extra heavy
tile members, conduit will sustain any roadway traffic load usually encountered without extra reinforcement.
Fig. 6--Single or Double Pipe Lines Using Sec-
tionol Pipe Insulation.
Fig. 7--Multiple Pipe Lines Using Filler Type
Insulation.
1056
Insulation Underground
The Ric-wiL Company
Agents in Principal Cities
<tce. u. e. pat. ore.
Established in 1910
CONDUIT SYSTEMS FOR UNDERGROUND STEAM PIPES
Union Commerce Bldg., Cleveland, Ohio
New York, Chicago, San Francisco
Ric-wiL Insulated Pipe Units--Pre fabricated, pre - sealed, ready - to - install units, ideal for speed and economy. Armco Iron Conduit is the foundation supporting heavy asphalt shell of any desired thickness--a permanent housing for the insulated pipe which is surrounded with a protective air-space. Ample struct ural strength, lightweight and watertight. Furnished in any lengths, for single or multiple pipes, with any kind of steam pipe or insulation, for underground or overhead steam lines. Welded couplings used if preferred. Write for latest Unit Bulletin.
Types of Sectional Conduit--Ric-wiL SuperTile Conduit, shown below, with DrypaC Insulation, is an extra weight, heavy duty system designed for use under high way traffic or in especially wide or deep trenches. Vitrified tile, split on the job, with Loc-liP Side Joints, interlocking con struction throughout. Same design also furnished in standard weight tile (Type F). Tile is bell and spigot design, lined or un lined, and comes in 24 in. sections, 4 in. to 27 in. inside diameter. For extra heavy duty under railways, Ric-wiL is made of cast iron in 2 or 4 foot sections. Where con tinuous concrete base, poured on job, is desired, and reduced labor cost not essen tial, Ric-wiL Universal Type System is recommended. Each system supplied complete with proper pipe supports, acces sories, and insulation as specified. Separate bulletin on any one of these Ric-wiL types supplied on request.
Base Drain--Standard Base Drain is vitrified salt glazed tile for tile conduit and extra heavy tile or cast iron for the cast iron conduit, in 24 in. lengths. Made in three sizes to support and drain properly all conduit sizes.
Insulation--Ric-wiL Dry-paC Water proof Insulation is high-grade long fibre asbestos, specially processed. Any grade of commercial hand packed insulation can be furnished, also sectional pipe covering. For lined conduit, diateomaceous earth mixture is molded and keyed inside the tile.
Engineering Service--Full coopera tion with architects and engineers. In stallation supervision if desired. Write for Catalog Bulletin with valuable under ground data.
1057