Document YDw36MrEOox2OOXoNZm06yroy
/
fldnsanto ( industrial' ..iemicals co.
* r . - T7F
Qecember 3 1974
: FDA OETECTIOH OF CHLORI MATE0 Dl8EN20FURANS IN AROCLOR
(
ee. R , . Ke I I ft r - 7 t g R.H. Munch - TI 9 V. R. Richard - r 3 A
TO : V. 9. Papageorge 82 S K
Per your recent request, I have talked by telephone with John
Roach of FOA regarding his paper at the national meeting of
the Association of Officia 1 Analytical Chemists reporting
detection of chlorinated dIbenzofurans (COF) in.Aroclors. This
memo documents our converse tion.
'
According to Hr. Roach, he and his co-workers have isolated
and Identified COF in Aroclors 1016, 1242 and 1254 but not in
Aroclor 1221. These reference Aroc1ors were provided by
Monsanto. The concentrations were 1n the 1ow (prnbab1y I - I 0)
ppm range. 3ichlorodibenzofurans were found in Aroclor 1016,
d I -tetra homologs in Aroclor 1242 and tetra and penta homo i.ogs
in Aroclor 1254. He estimates their 1ower limit of detection,
at less than 3.1 ppm.
'
The analytical method was similar, but not identical, to that used to detsrmine COF In Kanechlor 400 (see attached reference) . Isolation 0 * the COF was accomplished by column chroma tograony followed a v i iencif1 cat ion by GC/MS . 1 raised the question whether other aotential impurities such as chlorinated methyl biphenyls ;nich have similar mass spectra) could have been mistakenly sentified as COF. Roach 1 s response was negative, followed av a soohisticated and technically correct explanation that they - a ve ootained and characterized several chlorinated methyl 3ijnenyIs as reference materials to eliminate this possibility. They are currently attempting to identify some of Che in diy13 u a I isomers which have been isolated.
Roach agreed AOAC meeting completed in findings.
to send me a copy of Che paper he presented at t as we I I as a preprint of their entire study when about two months. They p1 an to publish their
e
Their methodology is similar to that first reoorted by Vos and duplicated in our laboratories during a 1971 survey of our ArocIor p-bducts for COF. This survey did not detect any COF with' a lower detection limit of <3.5 ppm for each isomer. (Several vomers at lower concen t ra Cions total ing >1 ppm could have been jrasent). Roach indicated their current technique gives better ;bu C not comp Ie C e) recoveries Chan the method c f Vos. FOA also -as a more sensitive MS than our current model, although we will nave a superior instrument i^t a few weeks
J . P. MIeuJr
KAINTrrS ex:**jit
l
906646 STR 006667
S0000074
y- 757
WATER_PCB-00052543