Document YDj8YRpnqapGBv2baNbDGdkzO
PLAINTIFF'S EXHIBIT
FIREPROOFING THERMAL INSULATION CONDENSATION CONTROL ACOUSTICAL ABSORPTION HIGH TEMPERATURE INSULATION SOUND ATTENUATION
GP045 0113
'prayIron products
SPRAYDON products ore designed to fill modern needs for .... economical .... light weight .... efficient .... fireproofing, acoustical treatments and thermal insulation requirements. SPRAYDON products are scientifically formulated blends of virgin asbestos fiber, mineral wool and proprietary binders. Research advances in material formulation, coupled with advances in design of application equipment, have created the new SproyDon finishes which produce .... harder .... firmer .... more abrasion resistant surfaces.
L
2
HIGH FIRE RESISTANCE
Tests by Underwriters Laboratories prove SPRAYDON firetest fiber as a fireproofing material of the highest efficiency.
RAPID APPLICATION
SPRAYDON is quickly applied by machine to many
surfaces in one pass using one trade..........................
no delays for multiple coats .... speeds job sched
ules .... reduces costs.
v-
HIGH PERCENTAGE OF BINDERS
SPRAYDON STANDARD fiber has been formulated with a high content of binders which produce a hard er, firmer surface with a superior resistance to abra sion and damage.
DUST FREE APPLICATION
Improved SPRAYDON formulations eliminate ap plication dustiness generally associated with con ventional sprayed fiber products.
LIGHT WEIGHT
SPRAYDON standard fiber weighs an average of one pound per board foot and result in substantial sav ings in dead load.
CORROSION PREVENTION
SPRAYDON standard has been tested in accordance with ASTM BT17 and Military Specification E-5272C for 240 hours. Results show that the application of SPRAYDON fiber to shop coated steel, galvanized steel or plain steel prevents corrosion and thereby the need for field painting of steel is eliminated.
COMPLIES WITH G.S.A. STANDARDS
SPRAYDON standard has been tested in accordance with standards set up by the General Services Ad ministration and has equalled or surpassed all re quirements. Withstands high air erosion-SPRAYDON standard has been tested and proved to withstand high air erosion-details on request.
------------------ PRODUCT GUIDE----------------
SPRAYDON "STANDARD"
: q>ecrfy for fireproofing of steel beams, girders, columns and metal deck and roof assemblies... .tested by both Underwriter's Laboratories, Inc., and Under writer's Laboratories of Canada ... .manufacturing controls, procedures and formulations regularly in spected by Underwriter's representatives. (Refer to pages 4 & 5).
: specify for acoustical installations___ used either alone or in combination with SPRAYDON TYPE No. I (Refer to page 3.)
: specify for condensation control in problem areas (Refer to pages 6 & 7.)
SPRAYDON "TYPE No. I"
: specify for harder finish . . . .light weight . . . .abrasion resistant .... acoustical installations__ .may be used alone or in combination . with SPRAYDON STANDARD. (Refer to pages 3 & a)
SPRAYDON "TYPE No. HI"
: specify for acoustical ceilings where only the hardness of a wet mot material will suffice. NRC ranging as high as .85. (Refer to page 3J
SPRAYDON "SPRAY-TEMP"
: specify for high temperature insulation or thermal insulation of high temperature processing equipment in the fields of power generating, refineries, steel process ing, paper, textiles and chemicals. (Refer to page 7.)
SPRAYDON "S A - 48"
: specify to reduce the transmission of sound through walls........highly efficient and low in cost. (Refer to page 3.)
SPRAYDON "ADHESIVE"
: used where required, is an incombustible latex type emulsion, applied prior to the spraying of the fiber mat to insure improved adhesion and bond strength.
SPRAYDON 'TYPE No.II"
: specify for insulation requirements... .special formulations make SPRAYDON TYPE No. II a superior, incombustible, insulating material. (Refer to page 6.)
SPRAYDON "SEALER"
: used where required, is a dear latex type finish coat used to provide additional protection for the fiber mat.
*110
ipreu/^on ACOUSTICAL TREATMENT
SPRAYDON fiber* offer the architect complete design flexibility. SPRAYDON may be applied directly to poured concrete shapes, plaster, sheet rock or metal lath. SPRAYDON produces a monolithic surface following the contour of the base, thus eliminating design restrictions on ceiling configuration.
The desired level of acoustical control is easily achieved through varied material thicknesses, proper choice of type or SPRAYDON fiber, and selection of either a solid or metal lath becking.
The finished SPRAYDON surface may be textured to suit the objective of the designer. Textures may be varied from fine to coarse travertine.
The color specifications of the decorator are easily achieved because SPRAYDON may be treated with latex type paints without reduction in sound absorption.
Sound Absorption Characteristics
inch**
noiso mounting cooffioont of sound absorption cit cps roductioa
125 250 500 1000 2000 4000 cooffiaoM
r
s *
olid .08 .19 .37 .41 .79 .78
R *** solid .38 .20 57 73 75 74
A 14* Y
motol lath
.44
.45
.75 .81 .89
J7
D
*
motal loth
.49
.45
.88
.93
.90
ST
O
N
olid .59 JO .71 .91 .91
58
J0 .40 .80
.85 75
The use of SPRAYDON provides the installation with a fire retardant surface which has a flame spread rating of 15 or less as tested by Underwriter's Laboratories (Refer to page 4.)
SUGGESTED USES
... .for finishing of formed concrete surfaces ... .thicknesses varied to eliminate or minimize base irregularities. ... .for a skim coat over gypsum board or plaster base for a low cost ceiling finish with acoustical properties. ... .for a finish coat for desired texture in areas where a higher level of acoustical control is required.
SPRAYDON TYPE No. 1
... .for acoustical control or correction in easily accessible
locations, where hardness, resistance to abrasion and damage are
important considerations. (Ex. low ceiling areas and side wall
applications.)
V
------for a harder finish coat (1/4" - 3/8") over STANDARD
fiber in areas where the higher sound absorption values or
insulation qualities of STANDARD fiber are desired.
SPRAYDON STANDARD
__ .for treatment of acoustical problems in areas requiring the utmost in noise control or reduction. (Ex. high ceiling areas, vaulted ceilings, auditoriums, theaters, etc.) __ .for treatment of condensation problems.
____for fireproofing of steel. __ .in combinetion with TYPE No. I at outlined above.
SPRAYDON TYPE No. m
... .the wet mix sprayed fiber which dries to a fine, white, granular finish with an NRC range as high as .85 whan applied to a type 7 mounting.
SPRAYDON "S A 48"
SPRAYDON "SA 48" fiber has been specially designed and
formulated to be a highly efficient and low cost sound barrier to the transmission of sound through walls. Tests conducted in accordance with ASTM E90-66T show that when applied to the
inside face of a gypsumboard wall erected on 2-1/2" metal studs (24" o.c.) the resulting STC value is:
1/2" gypsumboard -1/2" SPRAYDON - 45 5/8" gypsumboard 3/4" SPRAYDON - 48
HZ 126 160 200 250 315 400 500 630
s Transmission
p Loss, DB
R A
1/2" 1 22 26 33 37 37 41 44 44
3/4" 1 26 31
35 29 38 40 43 46
Y D HZ 800 1000 1260 1600 2000 2600 3150 4000
Transmission O Loss, OB
N 1/2" 1 45 46 48 49 60 48 48 49
3/4" | 49 51 51 62 53 53 54 55
. Santa Monica Library, Santa Monica, California
m Architect: Mathew Leizer - Thomas J. Russell ^ General Contractor: Parr Contracting
GP045 0115
3
iprai/M^on FIREPROOFING
FIRE HAZARD CLASSIFICATION OF UNDERWRITERS' LABORATORIES
SprayDon has been tested by the Underwriters' Labora tories, Ine.--for application to both combustible and non combustible surfaces. In all cases, SprayDon achieved a flame spread of 15 or less.
tUckMM
foal
tiriil in. bad** tpraod loafribotioo
aaaaka
dpi lath 10-13
10-13
0
* cart 13
20
0
* catltflaM 13 board
10-13
ref: R3655, 53C3636, R3656, 53C3635
0
General Motors: 769 Fifth Ave., N. Y. C. General Contractor: George A. Fuller Co., Inc. Architects: Emery Roth & Sons--Edward Durell Stone
Sprayon Contractor: Metropolitan Spray Division of Giamboi Brothers, New York City
Equitable Life Bldg., 3435 Wilshire Blvd., Los Angeles, Calif. Architect: Welton Becket & Associates General Contractor: Turner Construction Company
typical installations
Federal Office Building No. 7: United States Court of Claims & Patent Appeals -- Washington D.C. General Contractor: Blake Construction Co. Architect: John Carl Warnake Associates
Bell Telephone Data Center, Dorval, Que., Canada Architects:Webb, Zerafa Menkes Contractor:Inspiration, Ltd. Applicator: Oonalco Services Ltd.
The Life of Georgia Building, Atlanta, Georgia Architects: Bodin & Lamberson, Atlanta, Georgia General Contractor: Daniel Construction Co., Atlanta, Georgia American Tobacco Co., 245 Park Ave., N.Y.C. Owner Builder: Uris Construction Corp. Architect:Shreve, Lamb & Harmon Associates
Federal Office Building, West Los Angeles, California Architects:Charles Luckman and Associates, Los Angeles, Calif. Contractor: C.H. Leavell and Co., Los Angeles, Calif.
Atlanta Gas & Light Tower Bldg., Atalnta, Georgia Architect: Edwards & Portman, Atlanta, Georgia General Contractor: J. A. Jones, Atlanta, Georgia
bbiiiiiiiiijijijjiuiiiiiiiiiiiiiiiiiiiibwk'
Muiniiii imauuUII
First National Bank, Atlanta, Georgia Architect: Emory Roth and Sons, New York City Finch, Alexander, Barnes, Rothchild and Paschal,Atlanta General Contractor: Henry C. Beck Co., Atlanta Sprayon Contractor: E. L. Thompson & Son, Inc., Atlanta
A
GP045 0116
J
iprai/wn FIRE RETARDANT RATINGS
construction
SprayDon thickness
rating
authority
1.
w 2. o0 ad * cOo
3.
4.
2VS"
iwar-j--r-*-
Sul od
W
2V4" r^T j.
1V4" flat* plots
1/2*' 1 _ 1/16" in Flute
1/2" 1 - 1/16" in Flute
1/2"
1/2"
2V4"
IFSt,o'Vw1 .Im-.* -y.-*Vr.n-Ur= 1
Mended*
3"
' colli i.lQf
ji 12J4"
S3S3
J| 0%
columns
1/2" 7/8" in Flute
3/8*' 5/8** in Flute
1/2*' 1 -- 1/16** in Flute
1/2"
1 - 1/16" in Flute
1+ Small
2+ Med
3+ Larga
2-6/16" 1-1/2"
1-3/8"
1-7/8"
1"
1"
1-7/16" 3/4"
3/4"
3/8" **
;
3 hr.
U.L.C. 265-2
2 hr. 3 hr. 2 hr. 3 hr. 2 hr. 3 hr. 2 hr.
U.L.C. 265-2
U.L.C. 265-2
U.L.C. 265-2 ___ sJ_______________
U.L.I. R3655-3
U.L.I. R3655-7
U.L.C. 265-2 U.L.C. 265-2
4 hr. 3 hr. 21*.' 4 hr.
U.L.I. R3655-5 & 6 R3365-10 & 11
U.L.I. R3655-7
columns
Ul
3/8"
3 hr.
U.L.I. R3655-7
I Miaou* irdors -
3/8"
' 21*. , U.L.I. R3655-7
suioeq
/b'5U37~t- r . ,
m $3 '4"
ftj pond!
-*y- rod
h
ml 3-4
1 - 1/4"
/4 hr. -
U.L.C. 265-2
Wl W
GP045 0117
imppid biMi ? *
tjst,
Trench headers require V additional for 3 hr. rating. H" for 2 hr. rating "Both composite and non-composite construction Beam thicknesses are based on normal load method. Information on time-
temperature method at 1.000, 1,100, and 1,200 degrees F. avg. available on request. Spray don Standard Fiber may be Tamped or left Untamped at the thickness shown. Surfaces do not require either Adhesive or Sealer to meet U.L. requirements.
Column Notes on Sizes 1. Smaller than 14WF228 2. From 14WF228 to 14WF237 3. 14WF237 or larger
5
'praif^on
INSULATION AND CONDENSATION CONTROL
SPRAYDON TYPE NO. II fiber, with o k factor of 0.26 BTU/hr./sq. ft./inch of thickness, provides highly efficient thermal insulation as illustrated in the accompanying table.
SPRAYDON installations in areas such os boiler roams, metal buildings and to masonry surfaces perform three functions with a single application... thermal insulation... acoustical correction ... and condensation control.
In ceiling applications for swimming pool areas SPRAYDON serves four functions .... insulates an area which must be maintained at elevated tempers tures .... solves an extremely difficult acoustical
problem .... helps solve condensation problems .... and minimises corrosion caused by the presence of moisture and chlorine.
In any area where extreme temperature variations occur on the opposite sides of the same moterial, wall or ceiling, the application of the proper thick ness of SPRAYDON will provide the required insula tion and reduce heating or cooling costs. (Ex. metal building walls and roofs, metal roof systems, above and below grade concrete ceilings and walls)
Type No. I SPRAYDON with a k factor of .41 may be sprayed directly to masonry walls to receive direct plaster application, eliminating furring and lathing.
Heat Loss Characteristics Expressed in "U" Values
CONSTRUCTION
concrete
not
slab, inches insulated
SPRAYDON THICKNESS, INCHES 1 lh
2
built-up roofing on concrete roof slab
.V.'.vv*
4 6
.72 .30 .19 .14 .64 .28 .17 .13
.11 .10
metal deck with H inch Hwnrtj
roof insulation and
None
.40
.23
.16
.12
.10
built-up roofing
11
corrugated metal or tronslte wall
V
V
None
1.18
.36
.21
.15 '
.12
New Service Premises Quigg Motors Limited St. John, New Brunswick Applicator: Nova Spray Services Ltd*
j
6
'prayiron "SPRAY-TEMP" -- HIGH TEMPERATURE THERMAL INSULATION
r
SPRAYOON SPRAY-TEMP is a spray applied formulation of Inorganic mineral fiber combined with special binders for high temperature processing equipment. Spray-Temp may be applied directly to irregular sections and contours in a joint free blanket. Some typical uses are: boilers, ovens, steam pipes, turbines, precipitators, heaters, flues, spray booths,
PHYSICAL PROPERTIES*
General
Resistance: To Corrosion -- Good
To Solvents -- Excellent To Alkalies -- Good To Acids -- Poor
To Fungus -- Excellent Average values from accepted teat
Specific Heat - .20 Heat Capacity - .2 BTU/bd.ft/*F
Lots on Ignition -- 5.6% Volume Shrinkage -- 3.6% Linear Shrinkage -- 0.37%
COMPRESSIVE STRENGTH
. rtnriTutlnn11 Ih. dnltv15 ItH. UtlUilY 5 196 pif 10 300 pif 25 920 pf
625 pif 942 p*f 1910 pt
TEMPERATURE LIMITATIONS
Maximum Service Temperstars........................................................... Maximum Application ftmparatun.................................................... SiAtanncPomt................................................................................... Meltm* Point......................................................................................... Flesb-name point
I600*F 600*r
1700-1900*F 2200-2600*f
coverage
* Strength
90-120 board (Mt per CWT (av|. 100) .9-1.25* /board foot (av|. 1.00)
Density -- IMS pcf favf. 12 pcf)
Specific Gravity -- 2.29
Bond -- 100-300 psl (art ISO psf) Shear -- 150-275 psl (av|. 200 psf)
THERMAL CONDUCTIVITY
fh factor)
BTU /inch /hr. /sq.ft /F*
Mean TBmp^ratur^ F
50 75 100 200 300 400
k Factor
.240 .260 .275 .345 .405 .460
Maan Temperature F
500 600 700 800 900 1000
k Factor
.520 .585 .645 .700 .760 .835
TYPICAL APPLICATION THICKNESSES STEAM TURBINES
Steam Temp.
*F
below 250
2SO-349 350-449 450-549 $50-649 650-749 750-849 BSO-949 950-1049 1050-11*9 1150-1250
Max. Surface Temp. (90* ambient)
IX 110 115 120 12S 125 130 135 135 140 145
Intut. Cement
2 2H 3tt 4 5 6 6 6* 7 6 9
Thickness Cticium Silicate
m 2 2V* 3 3% 3H 4
4* 4fc 5 5H
Spray Don
Sprev-Yemp
IV* 2 2 2H 3 3H 4 4 4* 5 5Vi
On outdoor installations an addition*! H" thickness Is often used on srees which are exposed to weether.
heat exchangers, tanks, breechings, dryers, ducts, kilns, condensers,
digesters, furnaces, pipes, and enclosures.
advantages
ECONOMICAL APPLICATION Applied by SprayDon-trained, licensed contractors employing special equipment, Spray-Temp may be installed to
"on line" equipment, eliminating expensive down time. JOINT-FREE APPLICATION Spray-Temp's monolithic coating eliminates
critical heat loss at the seams and between layers of laminated insulations, Cutting and fitting are eliminated, scrap costs are eliminated and what is
left Is a one piece contour fitting blanket. DUST-FREE APPLICATION SPRAYDON Spray-Temp has been
formulated for the utmost in clean, fast, dust-free applications within critical areas; no respiratory hazards or dust contamination. PERMANENCE Spray-Temp will not putrefy and is mildew and rot proof. The monolithic application moves with normal expansion and contraction
of processing equipment without cracking or spalling.
GENERAL TECHNIQUES OF APPLICATION
In order to insure good adhesion, surfaces of the equipment to be sprayed must be dean and free of grease, rust, oil, or loose paint. All pins and/or studs shall be securely placed. The surface of the equipment is first wet with water end then SPRAY--TEMP is applied to a maximum of four inches thick per application. If heavier thicknesses are required,
SPRAY--TEMP is then tamped, reinforcing is secured end subsequent layers ere applied and tamped. Special additives permit the finish coat to be wetted slightly and troweled to a smooth texture. After the SPRAY--TEMP has been applied, the^pfoduct may be finished with any number of products including asbestos finishing cements, weatherproof mastics, industrial paint or metal lagging, but only after SPRAY--TEMP has thoroughly dried. In some cases protection from the elements is desirable immediately; in which case, a coating should be chosen which will permit the release of moisture during the initial 60-90 day period, and thereafter provide excellent resistance to moisture and vapor.
SPECIFIC APPLICATIONS Steam Turbines: The lower half of the casing shall be reinforced with either split welding pins or drilled and tapped 18" o.c. Apply SPRAY--TEMP to the desired thickness, tamp and apply t" hexagonal 20 gauge wire to pins or studs. Wire may be either Stainless steel or Monel and shall be stretched tightly and secured by bending the pins or by speed washers on the studs. If the surface is to be metal clad, the fiber shall be allowed to dry thoroughly and (aft in the tamped finish. If metal cladding is not used, then a coat of finishing cement shall be troweled on 1/4" thick and scored on 4' centers.
Vessels, Ducts, Fans, Flesh Tanks, Boilers, Steam Drum Haads and Stage Hesters: The same instructions shall be followed as for Steam Turbines except that the entire area shall be covered with welded pins 12 - 18" o.c. If a more finished surface is desired 6 or 8 oz. canvas may be laio over the cement finish lapping the seems about 3" and applying sizing.
Flue and Chimney Ducts: Steel pins welded on-staggered centers shall be applied to the outer surface of the stack. After the application and tamping of SPRAY--TEMP the surface shall be wrapped- with 1" hejfagonal 20-gauge galvanized or Monel wire mesh reinforcement and securely laced. Apply asbestos cement to a thickness of 1/4" and provide expansion joints or score 4' to 6' o.c.
Outside Storage Tanks, Heat Exchangers and Vertical Storage Tanks: Weld steel channels or angles on to the surface to be treated which extend 1/2" beyond the insulation thickness. Apply and temp the SPRAY--TEMP to the desired thickness. Wrap and lace 1" hexagonal 20 gauge galvanized or Monel wire mesh over the surface and apply two coats of mastic finish. The first shall be flush with the wire mesh followed immediately with a second coat of about 1/8" in thicknass. Furnace Housing, Air Heaters, Induced Draft Ducts and Fans, Hot Air Ducts, Precipitators, and Gas Ducts: Weld on 10 gauge studs to the surface 24" o.c. on top, 18" o.c. on the sides, and 12" o.c. on the bottom. After the application and tamping of SPRAY--TEMP, wrap the surface with 1" hexagonal 20 gauge galvanized or Monel wire mesh and depress the mesh into the surface of the fiber. Hold in piece with speed washers on the studs. A coat of finishing cement shell be troweled over the surface 1/4" thick (with or without corner beads) and scored 4' on centers.
HEAT TRANSMISSION CHART FOR FLAT AND LARGE OIAM. SURFACES
100* |
200*
ST H.L ST H.L
Tn 10B SO *T^ra 101 30
300* ST H.L. 138 100 120 70
400* ST H.L.
148 122
SOO* ST H.L.
000* 8T H.L.
700* ST H.L
800*
000* ! 1000*
1100* 1 1200* ! 1300*
ST H.L. ST- H.L. ST H.L. ST H.L ST H.L ST H.L.
a b 2 3 81 2
07 31 02 22 00 17
110 SO 100 42 90 33
130 120 100
00 68 82
182 138 130 08 120 76
178 147 130
170 128 08
168 160 148 124
183 160
180 187
1 2
07 13 00 27 103 42 112 80 120 78 138 102 180 129 180 131 100 38 107 80 110 88 128 86 136 108 140 112 180 162
bimh
BM ^BBft MUM
_____________ i
100 42
108 84 100 48
120 116 110
78 88 88
130 128 120 IIS 110
84 83 74 S8 SO
130 129 120 118 110
07 84 78 88 SO
180 140 136 130 126 120
132 lie 108 88 84 74
160 146 140 138 130 128 120
132 122 116 102 94 08 80
188 168 168 141 180 130 140 112 130 08 128 88 120 '80
160 160 146 140 138 130 128
147 134 122 113 100 03 84
NOTE: H.L.* Heet Loss (BTU/sq. ft./mr.) S.T.- Surface Temp.tF AM Calculations ara based on 80*F ambient still air.
"Spray-Temp" embodies a new formulation and manufacturing technique which yield the improved results over our former product "Power-Kote." In order to eliminate any confusion with the old formulation or any competitive formulations, we have changed the name to "SPRAY-TEMP."
7
GP045 0119
iprai/*on architectural specifications guidi
FIREPROOFING. . . ACOUSTICAL TREATMENT. . . INSULATION
It is suggested that these specifications be made a separate section to eliminate a double mark-up. -1
SPRAYED MINERAL FIBER
GENERAL CONDITIONS:
The General Conditions of the Specifications form a part of this section and the conditions contained therein shall apply to work performed under this section.
SCOPE OF WORK:
A. Work Included The work to be performed under this section shall include all materials, equipment, labor and services required to install the sprayed mineral fiber in accordance with this specification and as indicated on the drawings. B. Work Not Included: Surfaces to which the sprayed fiber is to be applied, as well as all clips, hangers, clamps, supports, sleeves, stops and other attachments to the base surface, shall be installed by others prior to start of work covered by this section.
SCHEDULING WORK WITH OTHER TRADES:
A. It shall be the responsibility of the General Contractor to coordinate all Sub-Contractors so that: 1. all items mentioned under "Scope of Work" paragraph "B," are installed prior to the installation of the sprayed fiber. 2. the installation of all ductwork, piping, fixtures, suspended ceilings, partitions, etc., shall follow the work covered by this section. B. It shall be the responsibility of this Sub-Contractor to provide the General Contractor with accurate production schedules , so that the General Contractor may coordinate the work covered under this section with the work of other trades, in order to speed up the progress of the job.
MATERIAL QUALIFICATIONS:
A. All sprayed mineral fiber shall conform to the applicable requirements of the local building code and have the approval of the pertinent municipal building authorities, for the required fire rating. B. The fiber shall have a thermal conductivity (k) of not greater than 0.26 BTU/hr./sq. ft./inch of thickness.
CONTRACTOR QUALIFICATIONS:
The Sub-Contractor shall be franchised by the manufacturer of the materials approved for use and shall use materials and application equipment approved by this manufacturer. All work shall be performed in strict accordance with the manufacturer's printed specifications and instructions, under the supervision of a manufacturer trained and approved foreman.
MATERIALS:
A. The sprayed mineral fiber shall be SPRAYDON as
manufactured for Sprayon Research Corporation by United
States Gypsum Co., or approved equal, and consisting
primarily of inorganic virgin asbestos fibers and mineral
wool fibers blended with proprietary binders. The Sprayed
Mineral Fiber shall be delivered to the job site in sealed
paper bags, properly identified, and labeled to show the
approval of Underwriter's Laboratories. (The last sentence
for fireproofing only.)
,
B. Adhesive, where required, shall''- be SPRAYDON
ADHESIVE or approved equal, consisting of a latex type
emulsion which, after setting, is unaffected by moisture,
freezing, or aging, (optional--Not required for fireproofing).
C. The sealer, where required, shall be SPRAYDON
SEALER, or an approved equal, (optional)
APPLICATION:
A. Inspection: This Sub-Contractor shall carefully examine all surfaces which will receive sprayed fireproofing and report in writing to the General Contractor, listing all unsatisfactory conditions. Sprayed fireproofing work shall not proceed until unsatisfactory conditions are corrected. B. Surface Preparation Surfaces which are to receive sprayed fireproofing shall be reasonably free of dirt, grease, oil, loose paint, excessive rust scale or other foreign material which would prevent adequate adhesion. C. Procedure: The application of sprayed mineral fiber shall be in accordance with the manufacturer's printed specifications and instructions. Thickness shall be sufficient to achieve the following ratings. (Architect indicate surfaces and hourly ratings). Where required, all surfaces to be treated shall be primed with SPRAYDON ADHESIVE. Sprayed fiber shall be applied while the adhesive remains tacky, tamped or left untamped to the required thickness and, where required, oversprayed with SPRAYDON SEALER, or water. (Tamping, adhesive and sealer NOT required for U.L. approval when fireproofing.)
NOTE: Tf,, above specification is intended for sprayed
fireproofing work. Where acoustical or thermal insulation specifications are to be written, select appropriate
paragraphs. Thermal Insulation or Acoustical Treatment: Add following
paragraphs: Under Materials: A. (1) Specify type SPRAYDON desired, STANDARD, TYPE No.
I. TYPE No. IX, SPRAY-TEMP, TYPE No. JO. SA-48 or any combination. (2) Specify thickness. (3) Insulation Treatment: Specify thickness required or Insulation value desired.__________________________________
GP045 0120
PAN AMERICAN PftlWTltS -- 7BUW
SPRAYON RESEARCH CORPORATION
and subsidiary SPRAYON INSULATION AND ACOUSTICS, INC.
1101 N.E. 110th Street, Miami, Florida 33161 Telephone: Area Cede 305*757-2312
PiintEd in USJL 7-6