Document YDgZwmOD8wq3LBxZNEJMJ1oan

FRICTION MATERIALS STANDARDS INSTITUTE, INC., E-210 ROUTE 4, PARAUUS, N,, J. 07652 . BULLETIN N 0. 5 8 1 October 12, 1976 RECEIVED OCT 181976 P. RKELTON CONTROL OF AIRBORNE..ASBTffQS CCf'CEWTRATIONS IN THE WORKPLACE - IV1XJSTRIAL TYPE VACUIM CLEANERS Over the past many months, without do-nmphasia on problsms In th fsctory area, l ho so In favor of stringent regulations-on the use of asbestos have targeted friction materials servicing--particularly brake lining service-- ss a potentially hazardous area. Technical papers in this area have not basod observations on the OSHA standard's 8 hour time weighted average for fibers greater than 5 microns in length. Most papers have emphasized peak concentrations (as blowing brake lining dust from a used brake awaiting roline) and ths fibers shorter than 5 microns in length. Based on discussions at the 'Asbostos Information Association meeting in September, efficient vacuum cleaning systems should be of holp not only in tho factory but in tho brako sorviee area. I have, therofora, enclosed solos literature from two manufacturers, along with the NIOSH (National Institute of Occupational Safety and Health) recommended procedures for asbestos brake and clutch r.orvicing, Bofore distributing this information, I rovlowed this data with Mr. I. H. i/naver, anting Chairman of our Acbnntos Study Conmlttos, to bo suro this Information was worthwhils. He concurred that tho following information wns worthy of distribution to the membershipi 1. NIOSH Recommended (Interim) Procedures for Asbestos Brako and Clutch Servicing 2. NILFISK literature 2.1 NILFISK abrsluta filter 2.2 NILFICK mano-ctor 2.3 Ikist free disposal 3. TCMPO Brako and Clutch Service Vacuum This literature is being enclosed (one copy to each mombar) with tho mailing toi Ur. F. C. Skelton Maremont Corporation Grizzly Friction Products 700 Vest Caroline Street Paulding, Ohio 45879 J.L .WlCUOMj EWD/erc E. n. Drislane Executive Director cc-Active lAombers Regional Members (Active Dues Level) Asbostos Study Committee ( smmsummm r MAR 000626 J KKC<-JC'...:m; n riioci.nURns for ASOKvro:; hr..'.: and cum.ii srnvicisc The National iMtltvif fur Occupation..! i.-.fcty and Health (KI05H) haa n'l.ivf-'h underway concerning duet exposurro during brake end clutch nervjrlng. Pm1 to pirllaitt.-iry data Jaaonnirating significant asbrttoe rxior.ur.'* during presently used brake and clutch servicing technique#, lUOSlI he# reviewed alternate techniques whereby aabcatoa exposures arc reduced. The fallowing arc inter!* procedure# recoaoended by NICSU ca laislea duxe exposure*. 1* If peasibln, an area ah.ill ba designated for all braka and dutch repair*. Entrance* Into thla area ahall ba poattd with a* aabactoa axpoaura warning sign at fallow#i Aabcatoa Dune Hatard Avoid Drenching Dust Wrnr Assigned Protective Equipment Do Not Ri.iiln In Arca Unlrao Your Work Require* le Breathing Aabeaeo# Puot Kay Causa Aebcatonla and Cancar 2* Curing brake servicing, an air purifying reap!rotor, cither single uaa er with repHn-eM* particulate tllier(e), ar. approved by the Klntr.g Enlorccacnt and Safety Administration (torarrly Bureau of Mines) or hI0r.lt, shell be worn during oil procedure* starting with the reeoval of the wheels and including rcusscnbly. During eanual dutch servicing, such a reeplrator ahall be worr. during reeoval and cleaning of the clutch, pressuro plate and houelng a*c*bly and during Instal lation of thu new dutch assembly. 2. Diet shall first be cleaned lrna brqVe drues, hrakt backing platea, brake assemblies and clutch assemblies using an industrial type vacuum rlxH-ct equipped with a high efficiency filter system (*992 efficiency for 0.3 w* dlaoctcr aerosols). After vacum cleaning, any reoalnlng dut shall ba reaoved using a rag snaked In water and wrung until nearly dry. Under no clreuitacancra ahall eoapreeacd air or dry brushing ba weed for cleaning. 4. During arcing and riveting operation#, #n approved respirator, aa described in (2) above, ahall ba von. Crindlng (arcing) sechinas dhall ba provided with local exhaust ventilation auch that worker exposures are aainrsined at lcaat below tho 1974 OSKA aabaatoo Standard (29 CPR 1910.1001).* AC a lnlau*t the dust beg of the arcing aochlna shall ba removed and replaced with tho boss of the. high efficiency Industrial vacuua described In (3) above. 7T /*!> MAR 000627 I yi mM 5# Industrial vacuum elconcr bar.* containing aobcetoe du*t and doth*' weed for wiping brake and clutch asscbblico ahall b* sealed In plaetle bag* end labeled with the following warning label printed In lettara of sufficient else ani contrast to be readily visible and laglbla; Caution Contains Asbestos Fibers AvofJ Breathing Dust Breathing Aabeatoa* Oust May Cause Asbestosis and Cancer All asbestos waste shall be disposed of In accordance with the OSKA asbestos regulation, 29 CFR 1910.1001(h). During reooval of vacuus bags, an approved respirator, as described In (2) sbove, shall bo vorn, 4, All floor cleaning In areas where brakce and elutches ore repaired shall be done with the high efficiency Industrial vacuus cleaner as described In (3) above. Crlndlng (arcing) saehlnes shall also bo cleaned with such a vacu-ta cleaner and.any regaining dust wiped with o danp cloth. An approved respirator, as described in (2) sbove, shell bu used during this elcanlng. 7, Although adherence to the above procedures ^should mlnlalee any contamination of work clothing, lc Is req'.ilrd that the appropriate portions of tho OSKA regulations on asbestos (29 CFK 1910.1001(d), (3 and 4)) concerning speelel clothing, ehango roo**, etc. bo followed. K0TE: Strict odherenc# to tho sbove procedures should elnleits exposures to sechanlca during brake end clutch servicing. These ere interim recom mendation* end ere subject to revision pending results sf ongoing W10SK research. * Section 1910.1001 of the Code of Federal Regulations was formerly Section 1910.93a. This change wes noted in the redexal Register, Key 24. 1973, Prepared By Dlvleion of flald Studios and Clinical Investigations Vationel Institute for Occupational Safety end Health Cincinnati, Ohio 11Ill'll ; Mil Ill) n i l MAR 000628 ySSILFISK absolute filter - where absolute clean air is a necessity The Nilfisk absolute filter la used when the air from the vacuum cleanar needs to be as pure as possible. This Is particularly Important in the chemical, pharmaceutical, ce ramic. asbestos, lead, electronic, food and enamelling In dustries. As well as other areas such as laboratories, white rooms*, computer rooms, institutions and hospi tals. Special versions of the Niltisk QA 72 and GA 73 have been approved by the -Staubforschungsinstitut*. Bonn, Ger many for use In areas where It Is essential to prevent the spread of health hazardous dust such as asbestos. Both these machines include absolute fillers, a shakable main filter and are provided with a manometer which Indicates when the filter needs to be shaken. 1 Nilfisk offer 3 and 4 stage filter systems a .a. *- et * iimi turface a*a m ttandard ThU allow* the sif to pan through at t towar speed. ensuring better MAR 000629 I uA NILFISK absolute filter fc* 'mproves safety standards in industries at risk from dangerous dust and fumes Pharmaceutical Induatrf Br uwng IM Nittuk aotoluia ima. tht oparitor it pfotactad againat danftfovt dual wfuia extning down aquipmant. Lead Industry Datpda ma nrf tincl pttcautiont <1 Itxca in mt load mduttiy lo protact iltlt't naaith, K it not peiiiWt to pravant dull panwlaa tailing on lo tno lloo< whtn eompontntt trt trantpoflad. To antura Uiat mu dual it not raiaad Into m almotpftara tnd mtitM. vacuuming witn a Nittiat machma ttttad wtm abaoiwta (matt it ma moit anactaw aotutian. MAR 000630 r.!QEL,C=,BBC . o. SOX 143. TW BUNCOMBt IT, aXIINVILLI. I. C. Mfl. (Ml) 1-3ni ALU OtMCtt 3344 MOVICT ITXIIT N. M, NABHINOTON. O. C *0007 . GA 73 OUST FREE DISPOSAL Nilfisk announces the introduction of a revolutionary dust* free disposal system! No more tilting and spilling; no more pouring collected materials into larger receptacles; no more dust clouds at the waste disposal point. Instead, line your Nilfisk model GA 73 vacuum cleaner, and/ or your cyclone separator, with heavy gauge (5 mil) poly ethylene liners. Insert the anti-collapse frame (which keeps the liner from being sucked up into the main filter.) Slide the container in under, the vacuum cleaner, step down on the pedal to close the machine, and you are ready to 90 to work. When the cleaner is full, turn off the motors, shake the filter thoroughly, lift the container release pedal, and remove the container. Your collected debris is now in the polyethylene liner bag. Simpler remove the anti-collapse frame, tie up the bag and dispose of it in completely DUST-FREE fashion! When ordering, be sure to specify correct part numbers; 017101 Container anti-collapse frame, GA 73 017301 Frame, 30 gallon separator 017201 Frame, SS gallon separator 017102 Polyliners, GA 73 (100 per case) 017202 Folyliners, SS gallon separator (50 per case) September 1976 7^/0/ MAR 000631 MAR 000632 d Jm CZZh TEMPO D BRAKE & CLUTCH SERVICE VACUUM* ^ _J / WITH AN APPROVED SPECIAL FILTERING SYSTEM "X ' FOR FAST COLLECTION & DISPOSAL OF ASBESTOS FIBERS During Service Work ... ... . . . Us* the procedure* recommended by NIOSH (National Institute tor Occupational Safety and Health) lor cleaning brake drum*, brake backing plates, brake and clutch assembllea. '*For employee safety In handling asbeetos, NIOSH specifies: 0 "Use an industrial.type vacuum cleaner etimppcd with a high efficiency -- litter system " 0 "Under no circumstances shall comprcs:d air or dry brushing be used for cleaning " 0 Grinding (arcing) machines shall also be cleaned with such a vacuum cleaner." 0 "All floor cleaning, where brakes and y clutches are repaired, shall be done with the high efficiency industrial vacuum cleaner as described above." 0 "Alt asbestos waste shall be disposed of in accordance with the OSHA regulation. Z9CFR 19101001 (h*.~ -i Model A8*7515 Oeeler Net $499.80 4 fdm *# $ tat# * | riN a**** OwJ--d *atO>H Reta"ii wwon ^Sie<rw w Tnmpo't AB-7S1S Orake/Ciutch Ssrvlce Vacuum and f illnr system paisod indopondant Envlionmental Lab Tests and it certified to comply with current OSHA regulations covering asbestos dust collection, filtration and disposal whan used according to instructions. k| S e iSiMOt BP MAR 000633