Document YDbmrmZRejJw937n3X84KZQGN

COST OF RAFTO PHASE-OUT ALL CHLORINATED BIPHENYLS EXCEPT DIELECTRICS 1970 LOSS IN SALES - LOSS IN GROSS PROFIT - $ 5.4 M $ 2.6 M IN ADDITION COGS WOULD INCREASE CIVING TOTAL LOSS IN GROSS PROFIT OF - $ 2.75 M. 1971 LOSS IN SALES - $ 12 M . TOTAL LOSS IN GROSS PROFIT - $ 6.1 M PLUS POSSIBLE WRITE-OFF OF SOME ? 2.6 H KRUMMRICH AROCLOR FACILITIES. COMPANY CONFIDENTIAL TRAN 089287 WATER PCB-SD0000044216 OBJECTIVE TO MAINTAIN A PROFITABLE BUSINESS SERVING THE NEEDS OF FUNCTIONAL FLUIDS USERS AND THE CARBONLESS DUPLICATING PAPER INDUSTRY WHILST MINIMIZING THE ESCAPE OF NON-BIODEGRADABLE BIPHENYLS INTO THE ENVIRONMENT. COMPANY CONFIDENTIAL TRAN 089288 WATER PCB-SD0000044217 3. ACTION TO ACHIEVE OBJECTIVES 1) MARKET NON-BIODEGRADABLE CHLORINATED BIPHENYLS ONLY FOR CLOSED SYSTEM APPLICATIONS WHERE CONTROL IS POSSIBLE. 2) PHASE OUT OF ALL NON-CONTROLLABLE APPLICATIONS REPLACING WITH BIODEGRADABLE CHLORINATED BIPHENYLS OR OTHER SATISFACTORY PRODUCTS. COMPANY CONFIDENTIAL TRAN 089289 WATER PCB-SD0000044218 PCH1 B PRODUCTION I Ji s. ka2 L 2 2 REGENERATION & RECYCLE 5- PCS* a USAGE INCINERATE ADSORPTION PROM AIR & WATER 4v BIODEGRADATION COMPANY CONFIDENTIAL TRAN 089290 WATER PCB-SD0000044219 5. DO WE HAVE THE CAPABILITY TO CLOSE THE LOOP ? ( COMPANY CONFIDENTIAL TRAN 089291 WATER PCB-SD0000044220 6. BIODEGRADATION 1) GOOD PROGRESS AT BOTH RUABON AND ST. LOUIS. 2) LOWER CHLORINATED ISOMERS RESPONDING WELL, BUT 5 & 6 CHLORINE ISOMERS EITHER NOT RESPONDING OR VERY SLOW. 3) CRITICAL PRODUCT IS 1242, CONTAINS SOME 50 ISOMERS -- GOOD RESPONSE ON 2, 3, & SOME 4 CHLORINE ISOMERS. 4) WORK IN HAND ON FRACTIONATED 1242 GOOD PROGRESS TO DATE. COMPANY CONFIDENTIAL TRAM 089292 WATER PCB-SD0000044221 REPLACEMENT PRO DUCTS 1) 1242B SHOWS GOOD PROPERTIES AS CAPACITOR DIELECTRIC NOW MAKINC 500 GALS. AT DAYTON FOR CUSTOMER TRIALS. ALSO WORKING ON 1230B. 2) GOOD PROGRESS ON PHOSPHATE ESTER REPLACEMENTS FOR HYDRAULIC FLUID APPLICATIONS. -- TCP -- CDP -- TBP -- NONYL FHENYL/CUMYL PHENYL DIPHENYL PHOSPHATE. 3) HEAT TRANSFER FLUIDS -- USING MAINLY ESTABLISHED PRODUCTS, E.G. HB-40 -- EXAMINING POSSIBLE ENTRY INTO DIPHENYL OXIDE PRODUCTION EITHER OWN PROCESS OR LICENSING. COMPANY CONFIDENTIAL TRAN 089293 WATER PCB-SD0000044222 3. TOXICITY 1) NO CHANGE SINCE LAST REPORT - HAVE DISCUSSED RESULTS WITH DR. BURGER, EXECUTIVE OFFICE OF THE PRESIDENT. 2) WE HAVE ANALYZED AROCLORS 1248 AND 1254 FOR OCTOCHLORO DIBENZO p-DIOXIN -- NONE FOUND. 3) CENTRAL INSTITUTE FOR NUTRITION AND FOOD RESEARCH, ZEIST, HOLLAND -- EXAMINED BAYER,PRODELAC AND MONSANTO CHLORINATED BIPHENYLS FOR DIBENZO FURANS -- NONE FOUND IN MONSANTO MATERIAL. COMPANY CONFIDENTIAL TRAN 089294 WATER PCB-SD0000044223 10. INCINERATION 1) SUCCESSFUL TRIAL AT JOHN ZINC CO., TULSA. 1242, 1260, 1254 DESTROYED AT 2000 F. -- OFF GAS HC1. ENGINEERING WORK NOW IN HAND TO BUILD SUITABLE INCINERATOR. ESTIMATED COST $250,000 M. 2) INTEND TO CARRY OUT FURTHER TRIALS ON STILL BOTTOMS. 3) INCINERATOR PROBABLY LOCATED AT KRUMMRICH. COMPANY CONFIDENTIAL TRAN 039295 WATER PCB-SD0000044224 3,500 ppb EMISSIONS 3,000 ppb 500 ppb eaenc Targets 1/71 9/71 5 Ibe./day KRUHHRTCH - ZOO lbs./day 1969 Present Target NEWPORT -0.5 lbs. COMPANY CONFIDENTIAL TRAN 039296 WATER PCB-SD0000044225 CLOSING THE LOOP FOR INDIVIDUAL BUSINESSES. COMPANY CONFIDENTIAL TRAN 089297 WATER PCB-SD0000044226 L3. TRANSFORMER & CAPACITOR DIELECTRICS 1) RESPONSIBLE INDUSTRIES USING 1254 AND 1242. 2) FIRE RESISTANCE EXTREMELY IMPORTANT. 3) COLLECTION AND RETURN OF SPENT AND ARCED FLUID. 4) REGENERATION AND RECYCLE. 5) TRIALS PLANNED FOR 1242B AND I230B IF SATISFACTORY. 6) LABELLING OF ASKAREL TRANSFORMERS. COMPANY CONFIDENTIAL TRAN 089298 WATER PCB-SD0000044227 14. HEAT TRANSFER FLUIDS 1) EDUCATION OF USERS WHERE FIRE RESISTANCE IS OBLIGATORY -- MAJOR INDUSTRIAL CORPORATIONS -- E-G. GOODYEAR AND CHEMICAL COMPANIES. 2) PHASE OUT OF ALL FOOD APPLICATIONS -- LETTERS WILL BE SENT OUT MAY 15ch -- NO SALES AFTER AUGUST 15th -- WILL COLLECT AND DESTROY OLD FLUID. 3) INSTITUTION OF REGULAR COLLECTION REGENERATION OR INCINERATION SERVICE. 4) PHASINC IN NEW PRODUCTS WHERE CONTROL NOT POSSIBLE. COMPANY CONFIDENTIAL TRAN 089299 WATER PCB-SD0000044228 15 . HYDRAULIC FLUIDS 1) RECOGNIZE THAT CONTROL OF SPILLAGE AND PUHP LEAKAGE MAKES THE USE OF NON-BIODEGRADABLE CHLORINATED BIPHENYLS UNDESIRABLE- 2) ALREADY REFORMULATED PYDRAUL 625, ACWG, 280 and F9 -- REPLACEMENT COMPLETE BY AUGUST 1 3) OTHER PRODUCTS IN INTERIM STAGES (E.C. PYDRAUL AC FORMULATION ON COMPRESSOR TEST AT JFQ). 4) AIM TO COMPLETE 90Z PHASE-OUT BY DECEMBER, 1970. COMPANY CONFIDENTIAL TRAN 089300 WATER PCB-SD0000044229 W. C. R. 1) U.K. HAS 'APPROVED HB-40, NOW PLACED REGULAR ORDERS -- EXPECT COMPLETE PHASE-OUT BY 1st JULY. 2) U.S. RUNNING TRIALS ON M.I.B.P., EXPECT DECISION 22nd MAY -- PRELIMINARY INTERIUM PRODUCTION OF 40 M POUNDS PER MONTH TARGETED FOR 30th AUGUST -- PLANNING FULL SCALE PLANT 10 M LBS. PER ANNUM ON STREAM END JANUARY 1971 -- ESTIMATED NFC $1 - 1.2 M. COMPANY CONFIDENTIAL TRAN 089301 WATER PCB-SD0000044230 17. PLASTICIZER & MISCELLANEOUS APPLICATIONS 1) DISTRIBUTORS ALREADY ADVISED NO MORE SALES AFTER 30th AUGUST. (ZOO CUSTOMERS) 2) LEXTERS TO 661 CUSTOMERS WILL BE SENT OUT 27th MAY ADVISING NO MORE SALES AFTER 30th AUGUST -- . DISPOSAL INSTRUCTIONS WILL BE GIVEN. 3) IH CONTACT WITH U.S.D.A. THROUGH AG DIVISION ON SILO PAINT PROBLEM. 4) BY 30th AUGUST ALL BUSINESS IN THIS AREA WILL BE PHASED OUT. - COMPANY CONFIDENTIAL TRAN 089302 WATER PCB-SD0000044231 K3-40 exfaxsio:; - a:e::sto:: saxto'.iax ' REFixr.w - axxistcx H3-40 CAPACITY - :~:?C3.T ,::z? capacity - a:c.::t::: ? C'JKYL/XOYY ;cs? ./RSCLAI-.I-XC EQ TOTAL NTI-: FIXED CAFI $ 27S.CC0 S 25C.CCO $ 1 , OvjD t uOC e? 1-i--o-r r* ,w-uoj $ 575.CCQ 223,CCO $ 3,525 ,'CCO COMPANY CONFIDENTIAL TRAN 089303 WATER PCB-SD0000044232 PRESENT PLAN 1) TERMINATE SALES OF ALL NON-BIODEGRADABLE CHLORINATED BIPHENYLS TO NON-CONTROLLABLE END USES. COMPLETE - AUGUST 30Ch, 1970. 2) DISCONTINUE SALE OF AROCLOR 1242 TO NCR AND REPLACE WITH HB-40 IN U.K., AND MIBP IN U.S.A. COMPLETE - U.K. ~ JULY 1st, 1970 COMPLETE - U.S. -- JANUARY 30th, 1971 3) CLOSE THE .LOOP ON HEAT TRANSFER APPLICATIONS WHERE F/R IS VITAL AND REPLACE WITH ALTERNATES IN OTHER CASES. COMPLETE - DECEMBER 30eh, 1970 COMPANY CONFIDENTIAL TRAN 069304 WATER PCB-SD0000044233 4) REPLACE ALL NON-BIODEGRADABLE CHLORINATED BIPHENYLS IN HYDRAULIC APPLICATIONS. COMPLETE 2OX - AUGUST lac, 1970 " 40X - NOVEMBER lat, 1970 " 1007. - DECEMBER 30th, 1970 5) CLOSE THE LOOP ON ALL NON-BIODEGRADABLE CHLORINATED BIPHENYLS IN ..TRANSFORMER APPLICATIONS. COMPLETE - AUGUST lat, 1970 6) CLOSE THE LOOP ON CAPACITORS AS FAR AS POSSIBLE AND REPLACE 1242 WITH 1242B. - COMPLETE - DECEMBER 31st, 1970 COMPANY CONFIDENTIAL TRAM 089305 WATER PCB-SD0000044234 FIGURE 1 WATER PCB-SD0000044235 'I FIGURE 2 Seai-Concinuous Activated Sludge Biodegradation 4 Aroclor 1242 Mixed Liquor After feeding COMPANY CONFIDENTIAL TRAN 089307 1-------------------------1 i........ > > .......i 0 a 4 a to . fss. WATER PCB-SD0000044236 PICORK 3 COMPANY CONFIDENTIAL TRAM 0S9308 WATER_PCB-SD0000044237 PP-OrirASIlITY rZTs.ZZ.KSX 1971 sxistt:- :.:.c:ica ascclcrs i SALTS G. ?. S.I.A.T. GROSS ISVSST53KI R.O.I. $ 22.0.?! $ 3.5 ?! $ 2.9 M $ 25.4 ?! 11.51 $ 20.0 v $ s.o T: $ 2.7 ?! $ 29.0 ?! 9.571 COMPANY CONFIDENTIAL TRAN 089309 WATER PCB-SD0000044238