Document YDbmrmZRejJw937n3X84KZQGN
COST OF RAFTO PHASE-OUT
ALL CHLORINATED
BIPHENYLS EXCEPT DIELECTRICS
1970
LOSS IN SALES
-
LOSS IN GROSS PROFIT -
$ 5.4 M $ 2.6 M
IN ADDITION COGS WOULD INCREASE CIVING TOTAL LOSS IN GROSS PROFIT OF - $ 2.75 M.
1971
LOSS IN SALES
- $ 12 M .
TOTAL LOSS IN GROSS PROFIT - $ 6.1 M
PLUS POSSIBLE WRITE-OFF OF SOME ? 2.6 H KRUMMRICH AROCLOR FACILITIES.
COMPANY CONFIDENTIAL
TRAN 089287
WATER PCB-SD0000044216
OBJECTIVE TO MAINTAIN A PROFITABLE BUSINESS SERVING THE NEEDS OF FUNCTIONAL FLUIDS USERS AND THE CARBONLESS DUPLICATING PAPER INDUSTRY WHILST MINIMIZING THE ESCAPE OF NON-BIODEGRADABLE BIPHENYLS INTO THE ENVIRONMENT.
COMPANY CONFIDENTIAL
TRAN 089288
WATER PCB-SD0000044217
3.
ACTION TO ACHIEVE OBJECTIVES
1) MARKET NON-BIODEGRADABLE CHLORINATED BIPHENYLS ONLY FOR CLOSED SYSTEM APPLICATIONS WHERE CONTROL IS POSSIBLE.
2) PHASE OUT OF ALL NON-CONTROLLABLE APPLICATIONS REPLACING WITH BIODEGRADABLE CHLORINATED BIPHENYLS OR OTHER SATISFACTORY PRODUCTS.
COMPANY CONFIDENTIAL
TRAN 089289
WATER PCB-SD0000044218
PCH1 B PRODUCTION
I Ji s. ka2 L 2 2
REGENERATION &
RECYCLE
5-
PCS* a USAGE
INCINERATE
ADSORPTION PROM
AIR & WATER
4v
BIODEGRADATION
COMPANY CONFIDENTIAL
TRAN 089290
WATER PCB-SD0000044219
5.
DO WE HAVE THE CAPABILITY TO CLOSE THE LOOP ?
(
COMPANY CONFIDENTIAL
TRAN 089291
WATER PCB-SD0000044220
6.
BIODEGRADATION
1) GOOD PROGRESS AT BOTH RUABON AND ST. LOUIS. 2) LOWER CHLORINATED ISOMERS RESPONDING WELL, BUT
5 & 6 CHLORINE ISOMERS EITHER NOT RESPONDING OR VERY SLOW. 3) CRITICAL PRODUCT IS 1242, CONTAINS SOME 50 ISOMERS -- GOOD RESPONSE ON 2, 3, & SOME 4 CHLORINE ISOMERS. 4) WORK IN HAND ON FRACTIONATED 1242 GOOD PROGRESS TO DATE.
COMPANY CONFIDENTIAL
TRAM 089292
WATER PCB-SD0000044221
REPLACEMENT
PRO DUCTS
1) 1242B SHOWS GOOD PROPERTIES AS CAPACITOR DIELECTRIC NOW MAKINC 500 GALS. AT DAYTON FOR CUSTOMER TRIALS. ALSO WORKING ON 1230B.
2) GOOD PROGRESS ON PHOSPHATE ESTER REPLACEMENTS FOR HYDRAULIC FLUID APPLICATIONS. -- TCP -- CDP -- TBP -- NONYL FHENYL/CUMYL PHENYL DIPHENYL PHOSPHATE.
3) HEAT TRANSFER FLUIDS -- USING MAINLY ESTABLISHED PRODUCTS, E.G. HB-40 -- EXAMINING POSSIBLE ENTRY INTO DIPHENYL OXIDE PRODUCTION EITHER OWN PROCESS OR LICENSING.
COMPANY CONFIDENTIAL
TRAN 089293
WATER PCB-SD0000044222
3.
TOXICITY
1) NO CHANGE SINCE LAST REPORT - HAVE DISCUSSED RESULTS WITH DR. BURGER, EXECUTIVE OFFICE OF THE PRESIDENT.
2) WE HAVE ANALYZED AROCLORS 1248 AND 1254 FOR OCTOCHLORO DIBENZO p-DIOXIN -- NONE FOUND.
3) CENTRAL INSTITUTE FOR NUTRITION AND FOOD RESEARCH, ZEIST, HOLLAND -- EXAMINED BAYER,PRODELAC AND MONSANTO CHLORINATED BIPHENYLS FOR DIBENZO FURANS -- NONE FOUND IN MONSANTO MATERIAL.
COMPANY CONFIDENTIAL
TRAN 089294
WATER PCB-SD0000044223
10.
INCINERATION
1) SUCCESSFUL TRIAL AT JOHN ZINC CO., TULSA. 1242, 1260, 1254 DESTROYED AT 2000 F. -- OFF GAS HC1. ENGINEERING WORK NOW IN HAND TO BUILD SUITABLE INCINERATOR. ESTIMATED COST $250,000 M.
2) INTEND TO CARRY OUT FURTHER TRIALS ON STILL BOTTOMS.
3) INCINERATOR PROBABLY LOCATED AT KRUMMRICH.
COMPANY CONFIDENTIAL
TRAN 039295
WATER PCB-SD0000044224
3,500 ppb
EMISSIONS
3,000 ppb
500 ppb
eaenc
Targets 1/71 9/71
5 Ibe./day
KRUHHRTCH -
ZOO lbs./day
1969 Present
Target
NEWPORT -0.5 lbs.
COMPANY CONFIDENTIAL
TRAN 039296
WATER PCB-SD0000044225
CLOSING
THE
LOOP
FOR
INDIVIDUAL
BUSINESSES.
COMPANY CONFIDENTIAL
TRAN 089297
WATER PCB-SD0000044226
L3.
TRANSFORMER & CAPACITOR DIELECTRICS 1) RESPONSIBLE INDUSTRIES USING 1254 AND 1242. 2) FIRE RESISTANCE EXTREMELY IMPORTANT. 3) COLLECTION AND RETURN OF SPENT AND ARCED FLUID. 4) REGENERATION AND RECYCLE. 5) TRIALS PLANNED FOR 1242B AND I230B IF SATISFACTORY. 6) LABELLING OF ASKAREL TRANSFORMERS.
COMPANY CONFIDENTIAL
TRAN 089298
WATER PCB-SD0000044227
14.
HEAT TRANSFER FLUIDS
1) EDUCATION OF USERS WHERE FIRE RESISTANCE IS OBLIGATORY -- MAJOR INDUSTRIAL CORPORATIONS -- E-G. GOODYEAR AND CHEMICAL COMPANIES.
2) PHASE OUT OF ALL FOOD APPLICATIONS -- LETTERS WILL BE SENT OUT MAY 15ch -- NO SALES AFTER AUGUST 15th -- WILL COLLECT AND DESTROY OLD FLUID.
3) INSTITUTION OF REGULAR COLLECTION REGENERATION OR INCINERATION SERVICE.
4) PHASINC IN NEW PRODUCTS WHERE CONTROL NOT POSSIBLE.
COMPANY CONFIDENTIAL
TRAN 089299
WATER PCB-SD0000044228
15 .
HYDRAULIC
FLUIDS
1) RECOGNIZE THAT CONTROL OF SPILLAGE AND PUHP LEAKAGE MAKES THE USE OF NON-BIODEGRADABLE CHLORINATED BIPHENYLS UNDESIRABLE-
2) ALREADY REFORMULATED PYDRAUL 625, ACWG, 280 and F9 -- REPLACEMENT COMPLETE BY AUGUST 1
3) OTHER PRODUCTS IN INTERIM STAGES (E.C. PYDRAUL AC FORMULATION ON COMPRESSOR TEST AT JFQ).
4) AIM TO COMPLETE 90Z PHASE-OUT BY DECEMBER, 1970.
COMPANY CONFIDENTIAL
TRAN 089300
WATER PCB-SD0000044229
W. C. R.
1) U.K. HAS 'APPROVED HB-40, NOW PLACED REGULAR ORDERS -- EXPECT COMPLETE PHASE-OUT BY 1st JULY.
2) U.S. RUNNING TRIALS ON M.I.B.P., EXPECT DECISION 22nd MAY -- PRELIMINARY INTERIUM PRODUCTION OF 40 M POUNDS PER MONTH TARGETED FOR 30th AUGUST -- PLANNING FULL SCALE PLANT 10 M LBS. PER ANNUM ON STREAM END JANUARY 1971 -- ESTIMATED NFC $1 - 1.2 M.
COMPANY CONFIDENTIAL
TRAN 089301
WATER PCB-SD0000044230
17.
PLASTICIZER & MISCELLANEOUS APPLICATIONS
1) DISTRIBUTORS ALREADY ADVISED NO MORE SALES AFTER 30th AUGUST. (ZOO CUSTOMERS)
2) LEXTERS TO 661 CUSTOMERS WILL BE SENT OUT 27th MAY ADVISING NO MORE SALES AFTER 30th AUGUST --
. DISPOSAL INSTRUCTIONS WILL BE GIVEN.
3) IH CONTACT WITH U.S.D.A. THROUGH AG DIVISION ON SILO PAINT PROBLEM.
4) BY 30th AUGUST ALL BUSINESS IN THIS AREA WILL BE
PHASED OUT.
-
COMPANY CONFIDENTIAL
TRAN 089302
WATER PCB-SD0000044231
K3-40 exfaxsio:; - a:e::sto:: saxto'.iax ' REFixr.w - axxistcx H3-40 CAPACITY - :~:?C3.T ,::z? capacity - a:c.::t::: ?
C'JKYL/XOYY
;cs?
./RSCLAI-.I-XC EQ TOTAL NTI-: FIXED CAFI
$ 27S.CC0 S 25C.CCO $ 1 , OvjD t uOC e? 1-i--o-r r* ,w-uoj
$ 575.CCQ
223,CCO $ 3,525 ,'CCO
COMPANY CONFIDENTIAL
TRAN 089303
WATER PCB-SD0000044232
PRESENT
PLAN
1) TERMINATE SALES OF ALL NON-BIODEGRADABLE CHLORINATED BIPHENYLS TO NON-CONTROLLABLE END USES. COMPLETE - AUGUST 30Ch, 1970.
2) DISCONTINUE SALE OF AROCLOR 1242 TO NCR AND REPLACE WITH HB-40 IN U.K., AND MIBP IN U.S.A. COMPLETE - U.K. ~ JULY 1st, 1970 COMPLETE - U.S. -- JANUARY 30th, 1971
3) CLOSE THE .LOOP ON HEAT TRANSFER APPLICATIONS WHERE F/R IS VITAL AND REPLACE WITH ALTERNATES IN OTHER CASES. COMPLETE - DECEMBER 30eh, 1970
COMPANY CONFIDENTIAL
TRAN 069304
WATER PCB-SD0000044233
4) REPLACE ALL NON-BIODEGRADABLE CHLORINATED BIPHENYLS IN HYDRAULIC APPLICATIONS. COMPLETE 2OX - AUGUST lac, 1970 " 40X - NOVEMBER lat, 1970 " 1007. - DECEMBER 30th, 1970
5) CLOSE THE LOOP ON ALL NON-BIODEGRADABLE CHLORINATED BIPHENYLS IN ..TRANSFORMER APPLICATIONS. COMPLETE - AUGUST lat, 1970
6) CLOSE THE LOOP ON CAPACITORS AS FAR AS POSSIBLE AND REPLACE 1242 WITH 1242B. - COMPLETE - DECEMBER 31st, 1970
COMPANY CONFIDENTIAL
TRAM 089305
WATER PCB-SD0000044234
FIGURE 1
WATER PCB-SD0000044235
'I
FIGURE 2
Seai-Concinuous Activated Sludge Biodegradation
4
Aroclor 1242
Mixed Liquor After feeding
COMPANY CONFIDENTIAL
TRAN 089307
1-------------------------1
i........
>
> .......i
0
a 4
a to . fss.
WATER PCB-SD0000044236
PICORK 3
COMPANY CONFIDENTIAL
TRAM 0S9308
WATER_PCB-SD0000044237
PP-OrirASIlITY rZTs.ZZ.KSX
1971
sxistt:- :.:.c:ica
ascclcrs i
SALTS
G. ?.
S.I.A.T. GROSS ISVSST53KI
R.O.I.
$ 22.0.?!
$ 3.5 ?! $ 2.9 M
$ 25.4 ?!
11.51
$ 20.0 v
$ s.o T: $ 2.7 ?!
$ 29.0 ?!
9.571
COMPANY CONFIDENTIAL
TRAN 089309
WATER PCB-SD0000044238