Document YDKNY66L6yk1q613xKyLjgpbE

uc 149-^ ^NIONK CARBIDE INTERNAL CORRESPONDENCE ------ H E C E i V ii J 0 197.-3 CHEMICALS AND PLASTICS V" BROOK, NEW JERSEY 08805 to (Nam*) otvMon Location Mr C. D. Nutter Chemicals and Plastics 511 h* Dlt< Originating DaeL Distribution Operations "* Mr. E. Bell Mr. A. E. Donaldson Mr. D. E. Gould Mr. R. L. Morgan Amwaring Uttar Oata SuWact Vinyl Chloride Sampling Central Region HEceiitj JUL 0 3 1975 8. H. WHEELED, Jg. Attached is a copy of the laboratory analysis of the samples you had taken at Memphis, Atlanta and Columbus warehouses: 873 - Peoples Cartage - Columbus, Ohio 305 - A&I - Memphis, Tenn. 336 - Kimbro - Atlanta, Georgia All results were less than 0.10 ppm. If you are going to furnish information to these varehouses, please put a "package" together Including employees, specific locations, handling actions, and specific resin identification. Send it to me to get legal approval before releasing it to the warehouses. JSN:sld Enclosure: ucc Corresponding Individual Organization Union Carbide h'CVAK Address P. 0. Box 670 Bound Brook New Jersey Telephone No, ( ) i- Ve have analyzed your Chemist-In-A-Can samples by flame ionization gas chromatography for the indicated components and have measured the following concentrations: Lm Sample l.D. 873-2 873-1 Date 4-1-75 3-27-75 Substances Checked For Vinyl Chloride i-ionomer tt Concentrations (PPM) OSHA TLV Found* Less than 1.0 * 0.5 0.1 It II 305-2 305-1 3-31-75 3-26-75 fl II II . - r-rn- twaA* II f II If 336-2 336-1___ 3-31-75 3-26-75___ II II 'II If II * *Limit,,nf"detection Analyst^ 1 PPM Date of Analysis ^"*4*75 Date of Report 4-14-75 ; 5flt * ' 5;4gg' Form 505 Please Note: We have moved to 80S Busse Highway, Park Ridge, 111. 60068