Document YD8MdvKEYOv8Y5Dz0ma9Xxapn

ABERDEEN CHEMICAL PLANT *' 11 * "j- % ROUTINE CHEMICAL DOSIMETRY SUMMARY Month of i> b Date of Report December, 1981 January 15, 1982 JF, CRM, PEM, PJK, RDJ, WFH, SJV, RAF, RAM,C4Hs) T. G. Grumbles - Houston, E. L. DeWhitt - Ponca City ALL SAMPLE RESULTS: - Chemical VCM Lead Ant imony Total Particulates OVEREXPOSURES: < PEL No. % 64 90 6 100 6 100 6 100 > PEL (Overexposure s) No. % 7 10 00 00 i 00 Job Class Exposure Source Maint. Supervisor Reactor Operator 1.2 ppm VCM 1.4 ppm VCM Specific cause unknown vt tl If General Mechanic General Mechanic Chief Operator General Mechanic Reactor Operator 3.6*ppm VCM 6.4*ppm VCM 6.5 ppm VCM 12.6*ppm VCM 17. l*ppm VCM Employee repaired recovery compressor in old vinyl unit. Employee pulled and cleaned vacuum pump. Specific Cause Not Found Employee repaired emission recovery system. Employee sampled PVC reactor * Respiratory protection worn. i * tap 1' mm m VAB.0001073498 b 2< PEL ; ABERDEEN CHEMICAL PLANT CHEMICAL DOSIMETRY TRENDS 4* - T wmmmmmm 4