Document YD81xNxDX9kxrL4gY7eGKgD3y
Heaters, Water
Thermal Appliance Company
/ /Incorporated
/ %/'
Sales Offices:
342 Madison Avenue, NEW YORK 332 S. Michigan Ave.. CHICAGO 7 East 42nd St.. NEW YORK
TACO WATER HEATER
For heating domestic water with the same fire that heats the home or building. There is a TACO for any steam, vapor, vacuum, hot water or hot air heating plant. Types for each heating system are classified below.
DOMESTIC TACO
Domestic TACOS and
Apartment TACOS are
connected below the water
line of steam, vapor or vacu
um heating boilers, capacity
30 to 960 gal.
Receive the heat from the
boiler at night as well as dur
ing the. day and in mild
weather, as no steam pres
sure is required. No benefit
is derived from the coal used
to bank the fire over night
unless a TACO is used.
Also recommended for heat
ing hot-water radiators in
connection with steam-heating boilers for bath
l> H rinsn\ ^'
rooms, garages, etc. Domestic TACO^--
Apartment Taco
Capacity 30 to 160
Boiler
gals.
No.
and
Coil on cover--1200
of Tank Water
tested connection.
fan- Size Con-
Apartment TACO---Capacitv 320 to 960 gals.
Hies nections
Copper U tubes expanded into Bronze tube plate. Easily removable for clean ing.
w12 320 2"
25 640 40 960 3"
Domestic Taco
List No. Capacity Price
30 30 $15.00
1 40 20.00
2 80 30.00
3 160
50.00
Patents Pending.
Amount of hot water used in an
apartment house varies. Capacity as stated is an average for a 4 or 5 room apartment having one bath and kitchen with usual fixtures, oc cupied by one family. For inter mediate or larger capacities, any number of TACOS may be installed
in a battery.
FLO-LINE TACO
Flo-Line TACO Heaters are for connection in the main outlet of steam or vapor heating boilers.
The steam, circulating about the coil which is connected directly with the range boiler or tank, thus heats the domestic water and main tains a full tank of hot water at a uniform temperature. Body of heater is sufficiently large so the pipe area is not restricted.
Water will be successfully heated at night or in mild weather from vapor from boiler when no steam is being generated in boiler.
No.
Capac ity
List Price
01 60 $25.00 02 120 35.00 03 240 55.00
Tank must be con nected above FloLine heater.
UNIVERSAL TACO
Recommended for use in the fire-pot of hot-water, heating boilers for attachment to thirty and sixty-gallon range boilers. The No. 9-30 and 9-60 are furnished with studs for round boilers having coil openings 9" c. toe.; 0-9-30, 6-9-60 without studs for round boilers having (coil openings) 6. 9 or more inches c. to c. The No. 3-30 and 3-60 for use with square boilers of any type. All types and sizes are malleable iron6--9--30 and 0-9-60 in Brass also.
9-30; 6-9-30; 3-30--...... 30 gal. 9-60; 6-9-60; 3-60........... 60 gal.
TACO TOOL
For use when tapping Boiler. Comes in three sizes: 1", \W and IW.
Where stocks are carried: TACO is carried in stock by all leading boiler and radiator manufacturers at their branch showrooms; and by leading jobbing supply houses.
268
l
Heating Systems
D. & T. Manufacturing Company
3001 La Salle Street
St. Louis, Mo.
ORIGINAL TANK IN BASEMENT SYSTEM
Placing the expansion tank in the basement on hot water installations is destined'to become the one general method. WHY NOT GET INTO THE GAME?
Eleven years' experience and up wards of 80,000 D. & T. Tank-in-theBasement Systems in successful opera tion throughout the United States and Canada, should be sufficient proof of the success of this system to the most skeptical heating engineer or contractor.
The D. & T. System is efficient, simple and foolproof.
Send for booklet entitled, "Pro gress in Hot Water Heating."
The Superior Air Sealed Pressure Controller is absolutely dependable, opening freely after long periods of inactivity. There is no danger of the con troller failing to relieve.
This Air Sealed Pressure Controller is different from all other relief devices. As you will note, by reference to the sectional view, the opening of the valve is effected by the pressure on the diaphragm.
This diaphragm being the well-known flexible type, has sufficient flexibility to allow the disc to raise up off the seat a full inch. This insures positive relief when the predetermined point is reached.
This disc is made of a composition which will stand a temperature of 300 deg. fahr. The seat is made of the well-known non-corrosion Monel metal, which is self-cleaning and assures proper action at all times. The disc is 1 in. in diameter and the bellows which lifts the disc from the seat is 2^ in. in diameter, there by giving a lifting power 6)^ times greater than the area of the disc.
269