Document YD0XyYNx8ekNm0Ny7bwd81pBk

projaot No* 141 R. ; v'-- : ' RESEARCH LABORATORY Swann Researoh, Incorporated Anniston, Alabama* SUMMARY REPORT t;,v, O,. METHODS OP TESTING AROOLORS : . . ;... r ' v. ' By - . H, B* Glass April 20, I93I v X ND BX ' Resistivity of Aroolors, Determination of. Dieleotrio Constant of Aroolors, Determination of* Power Factor of Aroolors, Determination of* Yisoosity of Aroolors, Determination of* Distillation Range of Aroolors, Determination of. Color of Aroolors, Determination of* Flash, and Flame Point of Aroolors, Determination of. Six ooples were made of this report and distributed as follows: No. 1 - File No. 2 - JT, N* Carothere No* 3 * R W* 0Sward (G*IF*) No. i - F. A. Lidbury V* jt;-./f :|fo, o - a* B. Gerber : ' DSW 331878 STLCOPCB4078453 OBJECTI To describe In detail methods used In testing Aroelors which are to be put to electrical uses. SUMMARY: . ; . . "; '......' ' ............... ' Test methods are given for resistivity, dielectric constant, power factor, viscosity, distillation range, and oolor. -^AA-ya ,.*A a CONCLUSIONSI - These methods are the ones used at present* They may be changed, or modified, later as warranted* INTRODUCTION t rr . This report serves to put on record methods of testing which have been developed and used during the study of elec* trical properties of Aroelors* DSW 331879 STLCOPCB4078454 STLCOPCB4078455 MIDGET CONDENSERS HEAD PHONES STLCOPCB4078456 rmi The circuit used tor this measurement la shown in Diagram A* A working drawing ot the test terminals Is shown* CALIBRATION OF APPARATUS ;- ;l<1- ' 'S-; >v: V . Kieotrode constant* The Figure is obtained by oalculat- lug the mean average area' of the two eyllnderleal electrodes. For the eleotrodes (test terminal*) shown In the drawing, this constant is 73* This figure mead* that the electrodes are equivalent to two flat plates 75* dm* epaoed 1 om. apart* CURRENT LEAKAGE IN CIRCUIT! Leakage within the test elrouit must be tested for at frequent Intervals* This is done by opening the circuit at the teat eleotrodes, (switch S also open), setting the shunt on unity and closing switch ?, The deflection of the galvanometer, after 3O-6O sec., must not be more than 2 mm. scale reading. If the deflection Is greater than this all insulating surfaces (switches, shunt, etc.) must be carefully cleaned. PREPARATION OF ELECTRODES! Before use, the eleotrodes glass plate and beaker must be very carefully cleaned and dried. This is best accomplished by cleaning them first with a small brush and benzene to remove grime. They should then be washed with hot distilled water, dried and washed in carbon tetrachloride* For cleaning after use in Aroolor a benzene wash should be used to remove all Aroolor. They should then be washed thoroughly with clean carbon tetrachloride and dried at 1000 for at least one hour* Care must be used not to touch any surfaoe of the electrode, plate, or beaker (which Is to come In eontact with the liquid to be tested) with the fingers, after the last washing* ...... .. FILLING OF ELEOTRODES! ; v v .. After drying for at least one hour at 100C. and with the beaker and electrode still hot, the liquid to be tested Is poured In* Care must be used to make sure that the lip of the contain-' er, from whioh the liquid is poured, Is olean. MEASUREMENT OF RES 1STIVIITI As soon as the liquid to be tested has reaohed the desired temperature, resistance measurements may be made. It is present practice to make these measurements exactly four hours after the liquid is poured over the eleotrodes*! The oell Is connected In, : by means of the screw dips, ten to fifteen minutes before measure ments are to be made. The center electrode Is then carefully pl&oed so that the spaoe between It and the outer eleotrode is DSW 331882 STLCOPCB4078457 equal at all points* With switch "S" open the shunt is set on the lowest ratio (.001) and switoh "P" dosed, Unless the approximate resistivity of the material being tested is known great ears must be used here to prevent too great a deflection of the galvanometer. The short ratio is then decreased until the galvanometer scale reading is^greater than 10 mm. but less than 20Q mm* Switch P is thenlnpenedP and switches/ closed,^ The voltage from the battery its then set at exactly 500 by * means of the variable resistance. The voltmeter must not be kept in the circuit during measurements* At the end of the four hour perold switoh s Is opened and P closed to either side* Exactly sixty seconds after closing P the deflecti^anef. the galvanometer is read, p opened and S closed* Three minutes later S is opened end P closed to the other side and a reading taken after sixty seconds. Pour such readings are taken, the average of which is used to calculate the resistivity* EXAMPLE! - 71 Deflection? Right left 4.8,30, Average 5P* Shunt setting? 0.01 Voltage? : SpQ Cell constant? yxu , Calvonometer sensitivity? 1 X 10**^ emps/mm (scale 1 meter distant)* Using Ohms* law R w X/l R * ^00 X 0*01 X 7^6 50 X 10-10 75*6 X lO10 ohms Bynconvention resistivity is reported as ohms resistance times 10 per om.5 (two plates 1 cm41 spaced 1 cm apart)* By this the above result becomes 7?o X IQb* CAUTION) MAKE SURE THAT SWITCH S IS OPEN BEFORE CLOSING slnM-f F, otherwise a direct short oirouit Is made. Also, if the inner eleotrode should touoh the outer eleotrode the shunt, or galvanometer, or both, will be burned out. POWER FACTOR AND DIELECTRIC CONSTANT? Diagram B shows the details of the oirouit used for these measurements* A two-stage amplifier is used now, however, In place of the single-stage one shown. The Instruction sheet which oomes with an amplifier tube will show such a circuit. DSW 331883 STLCOPCB4078458 The Aroolor condenser, 0* In diagram, of about 250 m.m.f. capacitance is carefully cleaned and dried and oonneo- ted la* With its plates full ih (la air), the precision air condenser, Ci, is set at any desired point and Its oapaotanoe recorded* A~aim. consisting of c. and 0X are now balanced by 0* and Oj, (midget condenser for fine adjustment) of B~axm. This point Is reached when the head-phone# become silent. With all Condensers filled with air the decade resistance should not be required* The plates of c* are now turned completely out and silence obtained in the pnones by adjusting G,. Curing this adjustment 0* and 0. must not be changed. The difference in oapaotanoe of 0. before and after change of setting of C, gives the capacitance Of Oj# * QAlIBRATXQK OF AROCLOR CONDENSSR (Ot) 0^ 3oale jReading ' ' maf (from Table I ) Hates In (air) Plates out 1800.0 2I92.4 Capacitance of 0 Plates out f\ ; . - Plates In (air) 1200.0 8IO.O Plates in (air) Plates out ' 14^0 1 - *79#$ Plates In (air) Plates out 4 1000.0 1390.5 - Plates in (air) " ' : . . hi- Plates out ,, h- v v- --r ~\ ;=: 200.0 Average 234.3 m.m.f* This value is that of the total change of oapacitanoe of C in air* 0y Is now filled with the liquid to be measured and the same procedure repeated. The ratio of the change of oapacitanoe of C* in air to its change of oapaoitanoc in Aroolor gives the dieleotrio constant. .. DSW 331884 STLCOPCB4078459 Plates in Plates out DIELECTRIC CONSTANT OF AROCLOR 1254 (Research Reserve Sample) '-v^. Soale Reading Capacitance '^>..-0 200 : 2208,3 - -. 110.0 Plates In Plates out -* \ - -' Hates in Plates out k'W5,u 200 2205 X 1196.6 - 5.11 w 110. 2226.0 X - 1208.3 * 5.15 110.0 1306.6 ' 1196,6"" 11. 1318.3 ~im;y Average K > 5*12 Condenser 0, must not be used below scale reading 200 or above soale reading 2400 as its oallbratlon curve is not a straight line below and above these points. It will be found that the decade resistance must be used when C* is filled with Aroelor in order to obtain silence in the phones. This added resistance, however, oan be negleotsd in the calculation of the dielectric constant, Great care must be used to remove all air from between the plates of c** Measurement of the dleleo- trio constant of Aroelor 1242 requires a smaller condenser at Cg than that required for Aroelor 1254* Measurements of dielectric constant are now made at 100C. After filling condenser C* with Aroelor to be tested it should be left in an oven at 100 for four hours. DSW 331885 STLCOPCB4078460 flaw*# STLCOPCB4078461 POWER FACTOR* This property of a dielectric varies very markedly with temperature and with frequency of the current* It is determined with the apparatus in Diagram B by removing condenser Ci and, balancing C (with plate in) against C (Be sure that midget C4 is turned completely out.), using the deoade resis tance* ' V-.:.: - '. Power factor (C R 2 W F) 1<T10 , Where C is the capacitance of C* (read from curve given in__ -^v /. . Table II), R the resistance read from the deoade and F the V^frequenoy of the A. C* Supply* This expression gives the power factor In percentage* PART III ' VISCOSITY* This measurement Is made at 212F using a Saybolt Standard Viscosimeter. Set the instrument level on a work benoh or table with the three legs of the jacket stand touohing the outside edge of the base block* .Fill the bath vessel with pale engine oil (of about 55O to 400F flash) so that the bath vessel will be full after this oil is heated end the turn-table cover adjus ted* Place the turn-table cover in position* Place perforated braes disc in position by means of rod with threaded end, being sure that the convex side of the diso is towards the bottom of the tube* Insert the bath thermometer into the holes of the Tees to which the stirring paddles are attached* The bulb of the thermometer should rest in the lower Tee, Insert the electric heater into the reoeptaole* \ Connect the attachment plug of the extension cord to a lamp sooket. Be sure that button switch is off when heater is out of bath* The heater will burn out in a few minutes if not covered by liquid when current is on* Heat the bath slowly, gradually approaching the temperature speoified for the test. To obtain this gradual heating, alternately conneet and discon nect the heater by means of the two-button switch. Do not alternately immerse and remove the heater from the bath, because with the heater removed and the ourrent on the heater will burn out. Keep the temperature uniform throughout the bath by means of a small stirrer. Do not raise the temperature of bath above highest graduation on bath thermometer. DSW 331887 STLCOPCB4078462 Clean the Inner tube with some of the oil to be tested by means of plunger* The perforated dlso above referr* ed to may be left in during this cleaning* Plaoe the small cork-stopper Into the lover outlet of the ell tube, just enough to make an air-tight el sure, but not so aa to touch the small orifice of the oil tube, Strain the oil to be tested from cup, through strainer| Into the oil tube until it overflows into the overflow cup, up to and above the upper edge of the oil tube. See that the bath is at the proper temperature to maintain the desired test temperature in the oil-tube and keep this bath temperature constant during test. Bring the oil in the tube to the desired test temperature using the oil-tube thermometer as a stirrer. This temperature should be uniform throughout the tube during the test. Remove the thermometer from the oil tube, " ... " . .' ., - - . Draw off the oil from the overflow cup down to and below upper edge of the oil tube by means of the pipette. By this procedure the oil-tube is exactly filled. Place the receiving flask in the center hole of the base block so that it touches the block at one point, thus permitting the oil to strike the neck of the flask when the cork-stopper is withdrawn. This procedure prevents foaming, which tends to obsoure the 60 cc mark on the receiving flask. How with the oil and bath at the proper temperatures, snap the cork-stopper from th orifice with one hand and simultaneously start the watch with the other. Stop the watch when the bottom of the meniscus of the oil reaches the 60 oo mark on the reoelving flask. The time in seconds required for the delivery of 60 oo is the Saybolt Viscosity of the oil at the test temperature, Seep the oil tube covered when not in use* Clean the electric heater of the non-oonduoting blaok carbonaceous matter that collects on its surface, by using the heater to boll water and then rubbing with a cloth, when the current is off. Steam or hot water for heating or old water for cooling the bath, may be Introduced through the U-tubc. Gas may also be used for ..heating* . . 4.4: 4 . . i .:i, 4 . ,, . . . . ? ` " ' part xv , : ' ' - '' ' FLASH AND FLAME POINTSt . test, The A.S.TsM Cleveland Open Cup is used for this PROCEDURE: The thermometer shall be suspended or held in a vertical position by the wire support. The bottom of the bulb shall be 1/4 in. from the bottom of the cup, and above a point half way between the center and back of the eup. DSW 331888 STLCOPCB4078463 The oup shall he filled with the oil to he tested in suoh a manner that, the top of the men 1 sous is exactly at the filling line at foam temperature. The surfaoe of the oil shall he free from bubbles. There shall he no oil above the filling line or on the outside of the apparatus* The test flame shall he approximately 5/3 2 in. In diameter, the same size as the head. ' The device for applying the flame may he of any suitable type hut it is suggested that the tip he approximately 1/16 in. in diameter at the end and that the or!fioe he 1/J2 in, in diameter. If the device for operating the test flame he mounted In suoh a manner as to permit automatic duplication of the sweep of the test flame the radius ofswing shall he not less than 6 in. The test flame shall ha applied as the temperature read on the thermometer reaches eaoh successive y F mark. The flame shall pass in a straight line (or on the circumference of a circle having a radius of at least 6 In.) aoross the center of the cup and at right angles to the diameter passing through the thermometer. The test flame shall, while passing aoross the surface of the oil* he in the plane of the upper edge of the cup. The time for the passage of the test flame aoross the cup shall he approximately one second# ; 1 ' .;i * ' ' ' '' The jute of heating of the oil shall be such that the temperature read on the thermometer Increases not less than 9 nor more than 11F per minute# PUSH POINTS ' The flash point shall he taken as the temperature read on the thermometer when a flash appears at any point on the surface of the oil. The true flash must not he confused with a bluish halo that sometimes surrounds the test flame. fum points 'v After determining the flash point the heating diall be continued at the specified rate, and application of the test flame shall be made at the specified intervals until the oil ignites and continues to burn for a period of at least five seconds. The temperature read when this ooours shall be taken as the flame point. DSW 331889 STLCOPCB4078464 PRECAUTIONS! .. .. . The flash point and flame point tests shall be made in a room or compartment free from air drafts. The pperator shall avoid breathing over the surface of the oil. It is desirable that the room dr compartment he darkened sufficiently so that the flash may be readily discernible. ,,7^ ' , v'. ' . ;... ?.... . . : r part . DISTILLATION RANGE! ^ (Applicable only to Aroolors that may be distilled at atmos* V pherie pressure,) -v-;; >_; . v . . . . ; ^^. 4 This method is a modification of that standardized by the A,S,T,M, References -- "Tenative Method of Test for Distillation of Bituminous Materials Suitable for Road Treat ment* (D20-28 T), A*S.T.M. Tenatire standards* 1929*47? ls Asphalts and Allied Substances by Abraham, 3rd Edition, Page 712, APPARATUS! The apparatus consists of a flask, condenser tube, shield, receivers and thermometers as specified, FLASK* The distillation flask, Fig, 213* shall be a side neck distilling flask, having the following dimensions! Diameter of bulb, outside 86 ram.*1.5 mm. Diameter of neck, inside 22 mm,|l,0 mm. Diameter of tubulature, inside 10,0 mui 0,5 ram. Length of neck 43 b1?-1** ram. Distance, top of neck to tubulature 2 rami 1,0 ram. Length of tubulature 220 mm.15.0 mm. ^ Angle of tubulature 73 deg,*l deg, "%(^ITOENSER TUBE! The condenser tube shall be a suitable form of tapered glass tubing of the following dimension Outside diameter ofsmall end Outside diameter of largeend Length Length of tapered part 12,5 B*m. 28*5 bbb* jJ^O.O mm. 100,0 ram. permissible variationfl.5 m permissible variation^,0 m permissible variation4*0 m permissible varIation+5.0 k SHIELD* A galvanized iron shield, lined with 1/8 in. asbestos, of the form and dimensions shown in Figure 214 shall be used to protect the flask from air currents end prevent radiation. The oover (top) may be of transite board made in two parts, or it may be of galvanized iron lined with 1/8 in, asbestos. DSW 331890 STLCOPCB4078465 ............. RECEIVER: The distillates shall he oolleeted In 100 oo glass graduates* THERMOMETER: The thermometer shall he graduated In degrees eentigra&e* . ' . y^. ;-y' \> -y y -v y.-.;. > .y, . , SAMPLE: The sample as received shall he thoroughly Stirred and agitated, warming if necessary* to Insure a complete mixture before the portion for analysis Is removed* PROCEDURE: (a) The flask shall he supported on a tripod or rings over two sheets of 20 mesh gauze, 150 mm* square, as shown in Figure 215. it shall he connected to the condenser tubs by a tight oork Joint* The thermometer shall be inserted through a oork In the neok with the top of the bulb level with the lowest point of juncture of the tubulature and neok of the flask* - y \ ;- y ".-.-.V / '- ' ib) The axis of the flask through the neok shall be vertical. - ' \. . . - '.7 - _ (0) One hundred ee of the sample shall he measured into the flask using the same graduate to he used for collecting the distillate* The apparatus shall then he assembled and heat applied so that the first drop comes over in from five to fifteen minutes* The distillation shall he conducted at a rate of three to five cubic centimeters per ainuts* The condenser tube shall be warmed whenever necessary to prevent accumulation of solid distillates* Temperature readings shall he made at the following points -- 1st drop 5 os -- 10 ee and then ever 10 eo up to the end point* (d) During the progress of the distillation the thermometer shall remain in its original position/ Correction shall he made for the emergent stem of the thermometer* / 7 *: . PART YI ; color: ' v \"i:;. - ' This determination is made by comparison method* An oil sample bottle is filled with the Aroolor to he tested and matched with the standards to the nearest one-half* crs: 4 24 31 COFY/pw 5-25-31 DSW 331891 STLCOPCB4078466 Inside Diem. 32 ram.43-l_inI , p^*. . '.:-. j\q up. Insl de. < , - ; .8 to 1*2 ram.,Wall \* A- i5?j 86 raou/ . \ "V v * >" S , - - J k Figure 213* -- Distillation Flask ##v*; /- few w f * * ^ .iijf pv^. ^ _ t1 1 ~|gf- L_;136 ram.--J l~k +.3 am. " 1 105 ram." >* 2 ramri It C-V* ^ ^ , ) * * , wmmm ^ * 1. '1 i f l 1 27 ram. ^l.O^ttm.1' / 1 \- U- 136 ram.-*3 0.5mm.' * - .or +, 3 ag--n= t. - , . ^ ^ ' . *. -. t ,,v J6 1 yjj if "T #Q *6 + m* 2`rara. J`* '*- . Cover In Two Farts ... ;" \* ir v ' * * . -- ram. .x+ *3,,rJa_m. w!j. | J ' ' ' 'J -';>- i /.'L.,*i' )'f,i t<* . 3f= lTi l7i6,ra9m-..S'>' B3 Km.I "'Shield ' Flatbed 6pen-end cylinder Made f *' 22 gage Galvenized'lron with l/8M Asbestos Lining Rivited to Metal. V*-'> - xV' * - < rt \v; ^V,,,, -" . -` ^' - , *Tl$,r 214. ^distillation.:- x v JtS-'* -h - - "- Shield ' Thermometer^ Shielc Re tort- Bunsen Burner- dork 88,5 ps. +_ 3 ass. Itopper,, *" ;sK; rf ,-12.5 ram. + 1*5 ran. am. ` ' Condenser ilmney A ram. ~x, i; 2 Sheets Wire 1; Gauze, 20 Mesh 1 -100-co Graduate Fig. 215;' -- Diet! 11ation Apparatus Assembly DSW 331891.01 STLCOPCB4078467 IV' A .,-1 * ' '........... ' - ' v- ....................... ; DIRECTIONS FOR TEST NO. SUBJECT: Color * "Kater White" Aroolors METHOD: Comparison against A.P.H.A. Soala Si'?-I- v, 'V - ' The method is applicable to Aroolors 1254, 1250, or others har- lug color less than K,P.A *1 ("Water"}* , - 1 ' -\ > . ;.V;. -r/: . ' : ' .V \' A.P.g.A. Standards - , These color standards are acid solutions of potassium chloro-- platinate and oohaltous ohlorlde, The unit of color is that produced 1>7 1 mg, of platinum per liter. The ratio of cobalt to platinum may be aried If necessary to match the hue. Because the hue of Aroclor : 1254 and i860 seems best matched without cobalt, this has been omitted in the preparation described, . Dissolve 1,245 g. of potassium ohloroplatlnate (XSPtOl*) containlng 0,5 g. of platinum In water with 100 ml* of concentrated hydro-- chloric acid, and dilute to 1 liter with distilled water. This solu tion has a color of 500. Prepare standards from 10 to 100 in steps of 10 by diluting 1, 2, 3 ml. etc, of the above solution with distilled water to 50 ml. in standard high form Kessler tubes, Protect the tubes from evaporation. Refer to page 13 of "Standard Methods for the Examination of Water . and Sewage" eighth edition {1935} for details of standards containing cobalt. Published by American Public Health Association, 1790 Broad way, Kew York, . L ' : : -- '' I procedqhe ' - x \;; / Pill a matching Kessler tube with Aroclor to a height equal to that In the standard tubes. Compare with standards by looking vertical ly downward through the tubas upon a white or mirrored surface placed at such an angle that light is reflected upward through the column of liquid, A color tube mupport (Fisher "7-065, 50 ml,) is convenient, Inasmuch as the proportions of the standard color solution in the ca parison tubes are suoh as to represent an aliquot part of a liter, the readings are direct as parts per million. Colors up to 100 are recorded to the nearest 5. Dlreot coaparisona are satisfactory up to 100. Above this the sample should be diluted with carbon tetrachloride (maximum A.P.H. color -- 5), and the color obtained -- to nearest 10 -- by multi plying by the dilution ratio, ABO-p 9/25/41 DSW 331892 STLCOPCB4078468