Document Y9vwRyxvZw4z8MdwnjJqLOX2y
19--Personal Protective Equipment
Fic 19-37 --Compressed oxygen (cylinder) rebreathing apparatus
as an autoignition source to gases with an autoignition temperature of 600 F or less The apparatus produces more oxygen than the user requires, so venting must be done periodically Some models do this automat ically but with others it must be done by hand The apparatus and canister should nor mally be stored at above-freezing tempeiatures and be completely started before being worn and used at subzero temperatures Quick-start canisters are available, these con tain chemicals that quicklv heat the canister to permit the apparatus to start quickly under low-temperature conditions
A new canister should be used each time the apparatus is woin, for it is dangerous to enter a hazardous atmosphere (or even engage m a drill) with a previously opened canister Used canisters should be promptly disposed of m accordance with instructions printed on
them- Used canisters should be kept away from combustibles so that residual oxygen will not have a chance to activate them. Only copious amounts of clean water should be used to destroy a canister
It is important that no one wear selfcontained breathing apparatus unless he is physically fit and well trained Physical fit ness and training are essential because poor physical condition of users and lack of proper training have been responsible for injuries and deaths After the initial training, men should receive refresher training at least every six months in order to maintain efficiency
The facepiece or mouthpiece and nose clip of a self-contained breathing apparatus should be carefully fitted to the wearer to ensure leak-proof protection against the hazardous atmosphere the man is to enter.
Half-hour and three-quarter hour apparatus are limited by the Bureau of Mmes for use only as auxiliary equipment m mine rescue and recovery work (See the U S Bureau of Mmes, Approval of Newly Developed SelfContained Breathing Apparatus, Instruction in tts Care and Use, and Training Procedure, In formation Circular No 7413 See also Na tional Safety Council, Respiratory Protective Equipment, Industrial Data Sheet 444 )
Because of the extreme hazard no one wear ing self-contained breathing apparatus should work in an irrespirable atmosphere unless other persons similarly equipped are tn at tendance, ready to give assistance
The compressed or liquid oxygen (cylinder) recirculating apparatus (Fig 19-37) This equipment is supplied with either a full facepiece or a mouthpiece and nose clip The seal around the facepiece must be kept abso lutely tight
Such equipment consists, essentially, of a high-pressure oxygen cylinder with reducing and regulating valves, a lung-govemed ad mission valve which supplies oxygen from the cylinder only during inhalation, a carbon di oxide scrubber and cooler, and a reservoir breathing bag connected by tubes to the mouthpiece or facepiece Check valves di rect the flow through the circuit so that the exhaled oxygen is purified of carbon dioxide, and rebreathed from the bag, with replenish ment from the cylinder as required The
504