Document Y9VOaJ1yb4E6NJjdqEoK7dKen
ABD00306489
\
1' '
ABERDEEN CHEMICAL PLANT
INDUSTRIAL HYGIENE MONTHLY REPORT
Month: June, 1986 Date of Report: July 28, 1986
I. ROUTINE CHEMICAL DOSIMETRY
All Sample Results CHEMICAL
PEL NO. %
> PEL (OVEREXPOSURES) NO. %
VCM Lead Total Particulates
80 97.6 15 93.7
6 100.0
2 1 0
2.4 6.3 0.0
Overexposures
JOB CLASS Chief Operator
EXPOSURE
**
2.9 ppm, VCM
Instrument Technician
1.8* ppm, VCM
SOURCE
Employee overexposed while preparing 742 reactor for a cooling jacket repair.
Employee overexposed calibrating the old fresh VCM receiver indicator.
while unit
level
Color Weigh Compounder
169.6 Mi^rograms Lead/MJ
Employee overexposed while weighing up small quantities
of Cyastab 988 and Tribase EXL for Compound Line V in the Color Weigh Room. At writing, the source of the employee's recent overexpo sures has been investigated and related to work practice changes caused by Line V startup. Corrective measures are being taken.
* Respiratory protection was worn. ** Respiratory protection was not worn.
II. HAZARD COMMUNICATION PROGRAM
- A Hazard Communication Program makeup class was held for six people.
- The Hazardous Material Reference Books were improved by adding index tabs and hi-lighting the product names on all MSDSs.
A
ABD00306490
In&istrial Hygiene Monthly Report Page 2
III. LAB VENTILATION
Lab ventilation hood airflows were checked. found.
No abnormalities were
IV. SHORT-TERM VCM EXPOSURES
Two short-term VCM exposure measurements were made during the blanking of the 745 reactor condenser. The measurements were made using REAL "Minimonitors" worn by two mechanics as they performed the work. Conclusions about the need for respirator protection during this job are being deferred until additional samples have been taken.
Mechanic
Sample Time
(Min.)
TWF Result (ppm, VCM)
A 145 ^0.1
B 166
0.2
A
c: JF, JWW, DWH, PJK, WFH, TFL, VEM, RAF, AHS, CWT Tom Grumbles, J. R. Drumwright, M.D. - Houston