Document Y99v2vaxajGZv8KE8GojXq4KE
A s b e s t o s Information A s s o ciatio n /N o rth America
22 East 40th Street New York, N. Y. 10016 (212} ,664=5296
GST SVl*
July 5, 1972
TO: AIA/NA MEMBER COMPANIES
AIA/NA ENVIRONMENTAL CONTROL SUB-COMMITTEE
' AIA/NA LEGAL COUNSEL
James Armstrong
- Bendix Corporation
E. C. Bratt
- H. K. Porter Company, Inc.
G. G. Gabrielson, Jr. - Nicolet" Industries, Inc.
Bernard Gross
- American Bilt Rite Rubber Company
J . Hall
- GAF Corporation
H. M. Jackson
- Johns-Manville Corporation
W. N. Johnson
- Union Carbide Corporation
A. R. Hooker
- The Flintkote Company
C. A. Neumann
- Kentile Floors Incorporated
G. W. Nickel
- Armstrong Cork Company
Clifford Seymour
- The Carborundum Company
J. R. Stetson
- Congoleum Industries, Inc..
Philip Weinstein
- Evertex Incorporated
G. W. Wright, M.D.
- St. Luke's Hospital
Gentlemen:
A meeting was held in Washington last Thursday between the
AIA/NA and representatives of the OSHA standards development
and compliance sections. Attending on behalf of the AIA
were John Marsh, Raybestos-Manhattan; Paul Weiner, GAF;
Hugh Jackson, Johns-Manville; Frank Zimmerman, National Gypsum;
Bradley Walls, AIA/NA Legal Counsel, and M. M. Swetonic,
AIA/NA Executive Secretary. OSHA was represented by
John O'Neill and Harry Gilbert of Standards Development;
and Ray McClure of Compliance.
-
The purpose of the meeting, as was discussed at the Association meeting on June 22, was to clarify a number of points with regard to the interpretation and enforcement of the asbestos standards. Because the standards are to go into effect this week, we considered it imperative to provide you with the basic points of interpretation and compliance established at the meeting. A more complete report on the meeting will be forthcoming in the near future.
ALLSTATE
Sponsored by Atlas Asbestos Co.. Cement Asbesloa Products Co.. C ertain tccd Products C orp.. Flinlbote Co . GAF C o rp ,. J o h n s -M a n v ille C o rp,. NalloiWJf G ypsum C o.. Panacon C o rp and fla y b c s lo s M a n lio lto n , Inc.
The-following are the main areas discussed and the decisions reached;
1, LABELING: The AIA/NA is applying for a temporary industry-wide variance on the exact wording of the labeling requirements of the standards, in order that existing supplies of boxes, cartons, bags, etc. containing a label with wording somewhat different than that called for in the standards will be permitted until they are used up. As long as the label currently being used contains basically the same information as the required one, it will be acceptable to OSIIA until stocks are used up.
Products to be labeled should follow the list ing submitted by Dr. Fred Pundsack of Johns-Manville to OSHA following the March hearings. A copy of Dr. P u n d s a c k 's list, with minor alterations, is attached for your information.
No product which requires labeling will be. permitted to be used without any label until existing stocks of non-labeled bags, etc. are used up. A stick-on label of some type would be satisfactory.
The size, color, placement, etc. of the label is left to the discretion of the employer, as long as the label is "readily visible and * legible." A good rule to follow would be: if you are trying to hide the label, OSHA will probably not accept it.
2. CLOTHES LOCKERS: Separate clothes lockers are required only for employees working at levels in excess of the five fiber TWA.
3. It was the intention of OSHA to require Type "C" supplied-air respirators and protective clothing only for insulation and fireproofing spray applications. AIA/NA will apply for a modification of the law to exclude other types of asbestos-spray applications from these requirements.
-More-
FMSI 06568
. -3 -
4. RESPIRATORS: There is a mistake in the standards in paragraph (d)(2)(ii) "Powered Air Purifying
Respirators." The first sentence of that paragraph now reads:
i
"A full facepiece powered air purifying
respirator, or a powered air purifying
respirator, or a respirator etc."
.
The sentence should'read:
"A full facepiece powered air purifying respirator, or a respirator etc."
The phrase "or a powered air purifying respirator" should be deleted.
5. MONITORING AND PHYSICAL EXAMINATIONS: Company monitoring and physical examinations should be conducted on all employees who regularly work with asbestos and are exposed to airborne fiber, as well as on maintenance men, company industrial
hygienists and other employees that the company feels require monitoring and physical examination because of the nature of their work or because of their close proximity to dusty asbestos operations. This would exclude office personnel, most people working in non-asbestos using sections of an asbestos manufacturing operation, etc.
6. CITATIONS: A company's own monitoring or other records will not be used as evidence to issure citations, nor will they be used to give a plant a clean bill of health.
7. OSHA INSPECTIONS: OSHA industrial hygienists will take dust samples. If at all possible, for a full eight hours, perhaps divided into two four hour samples. In addition, samples will be taken on more than one day, so that a more accurate count can be produced. Ceiling sampling periods will be at the discretion of the OSHA hygienist. Ceiling samples as short as five minutes may be taken if deemed appropriate. Under some circumstances
-More-
FMSI 06569
(an obviously very heavy dust concentration),
only ceiling samples may be taken, but this
would not be normal practice. Employers will
be given specific dust counts only if they
are in excess of the standard. Counts taken
by NIOSH hygienists will be reported to OSHA,
but will not be used by OSHA for purposes of
issuing citations.
.
8. EMPLOYEE NOTIFICATION: On the question of notifying employees if they are found to be working in dust concentrations above the limit, neither O'Neill or McClure would make a decision whether the notification clause in the standard would be satisfied by the posting on a plant bulletin board of stations above TWA, or whether a more individualized approach, such as sending the employee a registered letter, would be required. To answer this question, we were asked to write to the solicitors office in OSHA for a ruling. Unfortunately, a prior informal conversation between Paul Weiner of GAF and a member of the legal staff of OSHA indicated that the answer to such a question would be in favor of the registered letter approach. As a result, we have decided not to submit this question for a ruling, but will leave it up to each company in the industry to decide in what manner it wishes to abide by this requirement, and wait to see if bulletin board notification will be challenged by OSHA regional inspectors.
In general, the concensus of the AIA. group that attended the Washington meeting was that the industry could expect reasonable, treatment from OSHA as long as the industry did not try to circumvent the intent of the regulations. For example, the various requirements in the standard for protective clothing, change rooms, separate lockers, etc. have as their purpose
the preventing of excessive amounts of asbestos dust being carried home on an employee's clothes from work. As long as this purpose is achieved, the industry will be given wide latitude as to the types of protective clothing, footwear and headgear required; the location and size of change rooms;
-More-
FMSl 06570
-5 -
the distance between separate lockers, etc. In short, the industry is free to interpret many sections of the regulations as it sees fit, as long as the spirit and intent of the law is observed.
Sincerely,
Matthew M. Swetonic Executive Secretary
NOTE: The following is the new address and telephone number of the AtA/NA effective immediately.