Monsanto Ghemical Gompany
Anniston, Alsbams
Plant Laboratory
STANDARD ANALYTICAL METHOD
Mttnoa no. i___------ u^z---------------------------------
AR0CL0R8 THERMAL-CHEMICAL STABILITY TEST
DATS ISSUID
5/23/61
WRITTIN BY
W.W.K.
PAOS
1 op 4
APPPOVIO BY
W.W.K.
This Mathod
I | Supsritds* Ixl Raylsst
Instruction* Issued On
4/27/61
LlI ln < LlI CL 35 S Z> LtC O O 1 CO
1
i
i
SCOPE
This method describes the procedure for measuring Thermal-Chemical Stability of Aroclors, The sample is exposed to heat la a sealed ampoule followed by chemical exposure to alcoholic sodium hydroxide and the resulting chlorides determined potentiometrically.
EQUIPMENT
1, J2 mm Pyrex tubing - This tubing is used for making ampoules tuba is sealed off at one end and drawn to ca, 8 mm diameter and at a point approximately 120-130 nan from the sealed end are thoroughly washed with 107. HN03, distilled water, and
and dried before use.
ast. The i other
ampoules ;rade Acetone
2. Blue M Oven, Model 0V-580C.
3. 50-ral glass syringe. Clean thoroughly with AR grade At'to* and dry.
4. 13 ga. x 3-1/2" hypodermic needles. Clean same as syringe
5. Support for ampoules while in oven and while drying.
6. 200-ml tall form beakers (Berzelius type).
7. Magnetic stirrer,
8. Teflon covered magnetic stirring bar ln long. This bar should be cylindrical and of one piece molded construction.
9. Microburet graduated ln 0.01 ml subdivisions.
10. Sliver billet electrode (Beckman Cat. No. 39261).
11. L & N glass electrode (Cat. No. 1199-30).
DSW 331761
12. L & N pH assembly (Cat. No. 7664-Al).
13. Crystallizing dish 75 x 150 tan - to be used as water bath.
STLCOPCB4078336
Standard Analytical Method O39 May 23, 1961
Page 2 of 4 pageB
14, Uaual laboratory glaaavare.
REAGENTS
1. Methanol (chloride free) - 5 liters of methanol are refluxed with 0.5 g Analyti cal Reagent Grade AgN03 for 1/2 hour. The methanol la then distilled from the AgN03, discarding the first 100 ml. to flush the apparatus. 907. of the charge Is distilled from the flask and the contents of the flask are discarded. The methanol should be checked to assure purity by titration. The chloride Ion concentration should be less than 0.02 ml, of 0.0025N AgN03 per 100 ml. of methanol.
2. Sodium Hydroxide Reagent - Analytical Reagent Grade NaOH la used to prepare this reagent, A 0.1N solution Is prepared by dissolving 4,0 grams of analytical reagent grade NaOH In 1 liter of chloride free methanol. (For Anniston, 8,0 g, of 50% plant NaOH may be uaed),
3. Sulfuric acid - Prepared by a 50:50 volumetric dilution of Analytical Reagent grade concentrated sulfuric acid with chloride free distilled water. The acid Is always poured Into the water with constant stirring to prevent any dangerous build-up of heat.
4. 0.0025N AgN03. Dissolve exactly 0.4247g. of AR grade AgN03 In 1 liter of chloride free distilled water containing 3.O ml of concentrated HN03< This solution should be standardized against a pure chloride standard. A sodium chloride crystal such as used in infrared spectrophotometer cells is a good source of pure NaCl. Store AgN03 in a dark bottle.
\
5. Acetone (chloride free) - Prepared by distillation from AgN03 as described above, for methanol and should also be checked by potentiometric titration to assure optimum purity. Normally a chloride content of less than 0,02 ml of 0.0025N AgN03 per 100 ml. is derived by this method, (Note: If the solvent per se gives no greater titration volume than 0.02 ml, then the distillation need not be carried out).
SAFETY
Aroclors are irritating to the skin. The vapors of hot materials are irritating to the eyes and upper respiratory system. If accidental contact Is made with the eyes, flush iimnediately with large quantities of water for at least 15 minutes and get immediate medical attention. This test is carried out at elevated temperatures. Be very careful of thermal burns. Also, on occasion, ampoules have broken when un stable material Is in them. When removing the ampoules from the oven after testing, a face shield must be worn in case of violent breakage.
DETERMINATION This test must be run in duplicate
: i DSW 331762
1. Remove a clean, dry ampoule from the drying oven.
2. Place it in a suitable holder and weigh on a beam balance to the nearest 0.1 g.
3. Add ca. 40 ml of Aroclor to a clean dry 50-ml syringe.
4. Without touching the side of the ampoule neck, carefully slip the needle in= side the ampoule.
STLCOPCB4078337
f ' i '*
4
Standard Analytical Mathod O39 May 23, 1961
Page 3 of 4 pages
5. Add 50 + l.Og. of Aroclor and ra-weigh accurately. Record the weight.
6. Carefully withdraw the needle so as to not wet the ampoule neck. Notei If any Aroclor gets on neck, discard ampoule and start over.
7. Using an oxygen-gas flame, seal off the neck of the ampoule. Extrema care must be taken not to expose the Aroclor to over heating. Also, care must be taken so that the glass is never heated to white heat during the sealing because this yields light so intense that the radiation might be detrimental to the Aroclor.
8. Place the two ampoules in the support and put in the oven regulated to 240 +
2C.
"
9. Leave in the oven for 2 hours + 2 minutes. Note: Do not open oven during this
period.
"
10, When the ampoule is removed, allow it to cool to room temperature. For 1254, cool only to 50 or 60C.
11. The ampoule is opened by scratching with a file and striking the neck sharply with a spatula blade.
12. Pour the contents into a 200-ml beaker.
13. Rinse the ampoule with 10 ml of chloride free Acetone, (If 1254 is transferred at 50 to 60C., cool this solution to R.T. before proceeding).
14. By pipet, add 25,0 ml of methanolic-NaOH.
15. Add 25 ml of chloride free Acetone.
16. Using a pair of clean tongs add a stirring bar to the beaker. (DO NOT TOUCH BAR WITH HANDS).
17. Cover the beaker with a watch glass.
' 18. Place beaker in the water bath containing ca, 1-1/4" of water at 40C. + 1C.
19. Stir the sample as fast as possible without pronounced splashing for 5+0.5 minutes.
20. Remove beaker from water bath and add 0,5 ml of 1-1 H2SO4.
qs\N 33^763
21. By graduate add 65 ml of chloride free Acetone.
22. The sample is titrated potentiometrically with 0.0025 N AgN03 to the biggest break using a silver-glass electrode system.
Note:
Normal samples require extremely small amounts of AgNO.,. For this reason the titration is run using 0.01 ml additions and allowing sufficient time for equilibrium to be established before recording the emf change. If a change of 1 mv or less is observed per 0.01 ml increment for 3 or 4 additions, then increase the additions to about 0.05 ml until a larger change is observed. Then proceed with 0.01 ml additions.
STLCOPCB4078338
Standard Analytical Method O39 May 23, 1961
Page 4 of 4 pages
23. Run a reagent blank as follows:
a. 25 ml alcoholic NaOH b. 35 1 Acetone c. Stir 5 minutes @ 40 ^ 1C. d. 0.5 ml 1-1 HaSO^ e. 65 ml Acetone f. Titrate as In Step 22.
-
CALCULATIONS
Gross ppm Cl = (ml AgNO* Step 22 - ml blk Step 23) x 0.0025 x 35460 sple. wt.
Thermal-Chemical Chlorides = gross ppm Cl - Free ppm Cl*
Item C 3 Thermal-Chemical Chlorides - Hydrolysis Stability Chlorides **
Report both Thermal-Chemical Chlorides and Item C to the nearest 0.01 ppm. If duplicates, do not check within 0.10 ppm, re-run.
* Free chlorides are determined In Method 014
** Hydrolysis Stability Chlorides are determined In Method 010
DISCUSSION
Temperatures and times are very critical in this test. The temperature at which
this test is run (240C.) Is very near the point where decomposition takes an
almost vertical swing up. Therefore, the oven used in this test must be very pre
cise and accurate.
;
This Thermal-Chemical test gives a combined thermal and chemical stability. "Item C", the difference between T-C and HST Cl" can be interpreted as an expression of thermal stability.
REFERENCE
1. General Electric Report CLTM No. 48, Thermal Chemical Stability Test for Incoming Shipments of 1499 Pyranol, by J. F. Tracy, dated 4/27/61.
2. P. G. Benignus' memo to W. W. Klemme on 4/6/61.