Document XzZ02Xd1mqjZNaVMjKDgMnYKG
Insulation
The Upson. Company
|j^|
Lockport, New York
S UPSON Insulating BOARD
SvZ.
and
33Z.
UPSON Insulating LATH
Upson Insulating Board
Upson Insulating Board is a structural, rigid board form of-Insulation, made from -wheat straw, for use in walls, floors, ceilings and partitions. It quiets sound, saves fuel and adds comfort in all seasons.
Upson Insulating Board may be used as a. sheathing under wood shingles, wood siding, masonry or stucco veneer.
Tests
Upson Insulating Board, in its com mercial thickness, has a Resistance or Insulating Value of 1.36.
Conductivity per 1 in. of Thickness-- .324.
Conductance of Commercial Thickness --1.74 B.t.u. per square foot per hour per degree Fahrenheit Temperature Difference.
Tension 1 in. wide Commercial Thick ness--163J4 lbs.
Tension, pounds per square inch-- 362 lbs.
Mullen Test Commercial Thickness-- 433^ lbs. Modulus of Rupture--923 lbs.
Application
Upson Insulating Board is furnished
48 in. wide for application directly to studs,
joists or rafters spaced 12, 16 and 24 in. on
centers. Panels to be applied parallel to
studs and joists.
t
Upson Insulating Lath
Upson Insulating Lath is a structural insulating plaster base. It is scientiflcally designed to meet the exacting needs and requirements for obtaining better plastered walls and ceilings.
The exclusive nail slot, and enclosed feathered edge spaces at all edges provide room for the expansion of the lath. These permanent expansion spaces protect the plaster from strains arid stresses set up in the framing members, due to shrinkage.
The ship-lapped edges exclude infiltra tion of air at the joints, thus preventing unsightly streaks of dust deposits at these points.
Application
Upson Insulating Lath is furnished in panels 18x48 in. and is applied horizontally to studs and joists so that all vertical joints are staggered or broken. Only gypsum or other quick drying plaster should be used.
Sizes
Upson Insulating Board is supplied in panels Yv o in. in thickness--48 in. wide and lengths of 6, 7, 8, 9, 10 and 12 ft;
Average weight is approximately 70 lbs. per 100 sq. ft.
Sizes
Upson Insulating Lath is furnished in Ye >n. thickness, in individual lath 18x48 in; They are packed 15 lath to the bundle, each bundle containing 90 sq. ft. and weighing approximately 59 lbs. per bundle.
716
Insulation
MO. U. 8. PAT: Off.
The RIC-WIL Company
Union Trust Bldg. Cleveland, Ohio
CONDUIT SYSTEMS FOR UNDERGROUND STEAM PIPES
NEW YORK--CHICAGO--SAN FRANCISCO Agents In Principal Cities Established 1910
Conduit--Standard conduit is vitrified salt glazed tile or cast-iron with Loc-HP Side Joints, bell and spigot type, unlined or lined. Tile in 24 in. sections and cast-iron in 48 in. sections, sizes 4 to 27 in. inside diameter. Fully described in Bulletin No. 32. A special light weight cast-iron con duit with flanges, bolts and gaskets for bad water conditions and a heavy weight castiron conduit for extra heavy duty are also available. Send for A & E Sheets Nos. 14 and 23 for details of these special cast-iron conduits.
Base Drain--Standard Base Drain is vitrified salt glazed tile for tile conduit and extra heavy tile or cast-iron for the castiron conduit, in 24 in. lengths. Special U-Type Base Drain to hold return line and Support Blocks for use with round tile construction also available.
Pipe Supports--Standard Pipe Sup ports are of the externally supported type with rollers for single or multiple pipes. Load is carried entirely on side shoulders of Base Drain. Pedestal Pipe Supports are shaped like the Base Drain and set be tween Base Drain sections embedded in a concrete pier. I nternal Pipe Supports also available. All Pipe Supports are rustproofed. Details of Ric-wiL Pipe Align ment Guides and Anchors furnished upon request.
Insulation--Dry-paC Waterproofed Insulation, non-settling and non-corrosive --packed into the conduit becomes a solid mass'without cracks, joints.br openings-- positively non-capillary and water-repellant. Has low conductivity and insures highest thermal efficiency--non-waterproof kind also furnished. Lined conduit insula tion is a moulded diatomaceous earth mix-
Rie-wiL Cast Iron conduit has ample strength tcith minimum weight for use under roadways, railroad tracks, or other places subject to ex-. Irene loads and vibration. It is installed without delays and with out added con struction or engi neering.
Cutaway view at pipe support showing how Ric-toiL parts interlock. Note Loc-liP Side Joints and how pipe assembly i independent of the conduit. Cut shows Type DF System, lined conduit, with Dry-paC Waterproofed Insulation.
ture. Sectional pipe covering, sponge felt, 85% magnesia, etc., can also be furnished.
Accessories--Conduit fittings, with Loc-liP Side Joints for all types up to 15 in. are carried in stock--45 and 90 elbows, tee branches and reducers. Tee branches and reducers made to order for larger sizes. Mitred Base Drain fittings made for all conduit fittings. Shutter sleeves of galvanized iron, with asbestos rope for encircling pipes to provide a form upon which to cement or brick in ends of con duit lines. Filter Cloth to prevent sand, etc., from sifting thru broken stone into drainage area of Base Drain. Special asphalt cements for sealing all joints and waterproofing compounds for cement joints. Manhole covers, with non-rattling double lidded covers, furnished in 22 in. and 30 in. sizes.
Engineering Service--Cooperation in preparing preliminary surveys, plans and layouts or complete plans with full con struction details. Also installation super vision.
Technical Data--Tabulated Steam Heating Rates, Test Report Bulletins, Service Detail Bulletins, Catalog Bul letins, Central Heating Bulletins and Architects and Engineers Detail Sheets available upon request.
717