Document Xz9b2K4zx1N43G5v1732XbD9d
578
CHAPTER 27
1950 Guide
Table 5. Area op Flanged Fittings, Square Feet*
Nominal Pips Size (Inches)
1
2H 3 3H 4 4M 5 6 8 10 12
Flanged Coupling
Standard
Extra Heavy
0.320 0.383 0.477
0.672 0.841
0.945 1.122
1.344 1.474 1.622 1.82 2.41
3.43
4.41
0.438 0.510
0.727 0.84S 1.107
1.484 1.644
1.914 2.04
2.18 2.78 .3.77 5.20
6.71
90 Deg Ell
Standard
Extra Heavy
0.795 . 0.957
1.174 1.65
2.09 2.38 2.98
3.53 3.95 4.44
5.13 6.98 10.18
13.08
1.015
1.098 1.332 2.01 2.57
3.49
3.96 4.64 5.02 5.47 6.99 9.76
13.58 17.73
Long Radius Ell
Standard
Extra Heavy
0.892 1.084
1.337 1.84 2.32
2.68
3.28 3.96 4.43 5.00
5.09 8.56 . 12.35 16.35
1.083 1.340
1.874 2.16 2.76
3.74 4.28 4.99
5.46 6.02
7.76 11.09 15.60 18.76
Tee
Standard
Extra Heavy
1.235
1.481 1.815 2.54 3.21
3.66 4.48 5.41
6.07 6.81 7.84 10.55 15.41
19.67
1.575 1.925
2.68 3.09
4.05 5.33
6.04 7.07 7.72
8.52 10.64 14.74 20.41
26.65
. Cross
Standard
Extra Heavy
1.622
1.943 2.38 3.32
4.19 4.77 5.83
7.03 7.87 ` 8.82
10.08 13.44
19.58 24.87
2.07
2.53 '3.54 4.06 5.17
6.95
7.89 9.24 10.07 10.97
13.75 18.97
26.26 34.11
* Including areas of accompanying flanges bolted to the fitting.
Standard thicknesses of 85 per cent magnesia pipe covering are not exactly 1 in. However, the loss through any given thickness of insulation can be obtained by interpolation. Also, the losses through any of the insulations given in Table 6 can be obtained by multiplying the losses obtained from Figs. 1, 2, or 3 by the factors given in Table 7.
Pipes operating at high temperatures are frequently insulated to the
Table 6. Thermal Conductivity (k) of Various Type Pipe Insulations for Medium and High Temperature Pipe*
Expressed in Btu per (hour) (square foot) (Fahrenheit degree temperature difference per inch)
Types op Insulating Materials
Density Lb/Cu Ft
Temp. Range op Accepted
Use
Mean Temperature, F Deo 100 200 300- 400 500
Corrugated Asbestos--Type
Laminated Asbestos--Type Mineral Wool--Type....... ......... ......................
12-14
11-13
30-35 10-15 25-30 13-15
Up to 600 F
Up to 300 F Up to 300 F Up to 300 F
Up to 700 F Up to 800 F Up to 1900 F Up to 1200 F
0.39
0 15
0*51
0.51
0.39 0.40 0.63 0.34
n*rn 0 67
0.44 0.45 0.66 0.39
065
0.49
0.69 0.44
0-72 0.13
0.75
* Average values from laboratories for insulating materials of Various manufacturers!
Table 7. Pipe Covering Factors
Types op Inbulatino Materials
Temperature Dipperence, Pipe to Air. F Deg 100 200 300 400 500
Corrugated Asbestos--Type'
Laminated Asbestos--Type............................... Mineral Wool--Type... .................................................. Diatomaceous Silica--Type................................................... Brown Asbestos Fiber--Type........................
1.30 1.19 1.15 0.96 0.98 1.37
0.86
1.36 1.23 1.19
0.9S 1.00 1.36 0.88
1.42 1.27 -1.23 J
1.00 1.02 - 1.35 0.91
L02
1.05 1.35
0.93
i.M
1.07 1.34 0.96
Pipe: Insulation
579
best; advantage by combining a high temperature inflation''.near;-the pipe with a moderate or low temperature insulation around it ,as an outer layer. By this method an efficient material may be used for each of the two temperature ranges encountered. In calculating the heat loss
Fig. 1. Heat Loss Through 1 In. Thick 85 per cent Magnesia Type Covering
.through such a combination the mean temperature of each layef must be determined along with the thickness of each. This is readily done in three or four calculations performed as a series of approximations,, in which assumptions of thickness and mean temperature are adjusted, .as indicated1 in the discussion which follow?.
In'the cSse of a single thickness of pipe covering, the quantity, bf^heah