Document Xz5JaqrLo3kwmq8z8oqk7M74w
3t. Louis - Oeneral Offices
Mack Nlohola - Cleveland
September 3. 1965
AltOCLOB 1242 -- Reliance electric * engineering Cnmpanr. Clave'end
Richard Davis RDAVI
Aa I told you on tba telephone Hr. Harodoa called mo earlier this week quite disturbed aa a reault of my letter of August 27. This letter apparently alerted him somewhat to the potential toxic hazards of the use of Aroelor 1242 at elevated temperatures. He told me that the Monsanto litera ture furnished him had been Mere reassuring In terms of what problems might arise In their application. I guess what really shook him was when 1 mentioned that with temperatures greater than 150 mechanical exhaust ventilation should be provided to remove vapors.
For the record Nr. Haredoa' application involves the use of Aroelor 1242 aa a coolant in electric motora. Two motors are mounted an mining equipment used at the face of a drift. Total volume of Aroelor for the two motors is approximately two-gallons. Haredoa estimates that four quarts per day of this quantity would be lost in the mine -- presumably all of it by volatilization. I told him I doubted that the ventilation provided In mines would be sufficient to keep this amount of Aroelor at the threshold limit value of 1.0 mg/ou. aster of air. He told me there had been same complaints in mines where the motors were being used. He wasn't specific but I understood that the complaints were of odor end Irritation. Whether or not the levels are actually irritating I don't know. It may be that the miners have Just recognized that there la some thing in the air now that wasn't there before. Mr. Haredoa went an to say that la his own plant hot Aroelor spills an the floor were c o m m a and that his own employees had complained of discomfort. I was brutally frank and told him that this had to stop before be killed somebody with liver or kidney damage -- not because of a single exposure necessarily but only to emphasize that 6-hour dally exposures of this type would be completely unsafe.
Haredos called a second time to Inquire about the decomposition products with specific reference to decomposition products resulting from elsctrlo arcing. I told him that we had Underwriters' Laboratories reports on heat transfer fluids which were pertinent. He recognized that the chief decomposition
HONS 097873
Richard Davis
Fags 2
9/3/63
product would likely be UC1. I emphasized that this In itsslf Is a good "warning agent" which ssrvsa to U n i t voluntary exposure to high concentrations or decomposition materials.
I told Nr. Harsdos further that the Nodical Department was skeptical about the use of Aroelora In mining operations because we had not seen data to show absence of toxlo levels.
I emphaslzsd and re-smphaalzsd that the Aroclors are
excellent products but must be used In closed s y s t e u if
they are to be heated. HI Implied In his second conversation
that his engineering grouf was looking at redesign to provide
a "sealed" system.
^
EPWimJb
Elmer P. Wheeler
P.S. Mr. Haredos pointed out that In his application the Aroclor could be heated up to nearer 400y than the 1 5 07 figure willoh I had mentioned.
EFW
HONS 097874