Document XwvOVVMnONyqZxjxeXQ7a8Xd

Monsanto ' B2SH Cloning Paton i MU *.# Ootober 14, 1971 Status of PCBs MMMMCI TO : 1070 H. R. FORD 1010 R. A. GARCIA 1600 D. R. HANSEN 1650 P. L. SLAYTON "B2SL B2NK B2SJ W4A B2SH B2SH B2SH T. L, W. B, N. T. P. S, P. G, D. E, D. R, Oossage Papageorge Johnson Park Benignus Roush/j. J. Roder Pogue CONFIDENTIAL The following are the notes I used in the PCB "presentation" that must have held you enthralled at midnight after a 17- hour dayl Dielectrics 1. {ew?cwne- Produot Changes (a) Aroclor 1242 for capacitors changed to more bio- . degradable 1016. -- U. S / C/^At> * oj ^ * -JLj JS'TM"1* (bl Aroclor 1221 renamed Capaoitor 21. uuj* r- (0) In transformers no major changes planned. (d) Research under way on PCB replacements. (Don't expect results in under 3-5 years.)-- QoiO F. 2, Customers ()>a m tiTicf) Effective October 4, dielectric fluids must be ap proved prior to order entry by p. o. Benignus or C. Paton and W. B. Papageorge or T. L. Oossage. To prevent the need to approve all rders, a list of approved customers In both capacitors and trans formers has been compiled and will be circulated by October 18. Field sales should scrutinize HIP runs re customers and order size. Follow up on doubtful ones and alert Product Group and COP. Regional managers to add one line to their monthly report: Unapproved Fluid Sales; (No or Yes) ir yes, a separate report should be sent on this. Customer Notification it) A letter on the pollution aspects of PCBs will be sent to cus tomers. This is being cleared with the Legal Department. ANSI An S.I.B. has been written on the formation of Committee C107 MQNS 100055 -2- of ANSI. This committee will address Itself to the problems FCBs pose for the dielectric Industry. Pollution Control We are addressing ourselves to the pollution control or lack of It related to "service centers" for transformers or transformer users who buy only replacement fluid from Monsanto. Heat Transfer Fluids 1. Conversions Conversion of direct food-related users: completed, Conversion of curtain eoaters 80< complete). Conversion of film and foil producers D. E. Roush prepar Conversion of adhesive manufacturers ing list of target Conversion of resin manufacturers for accounts for conver paints and coatings. sion. 2. Restrictions No PR fluid sales for new applications will be strictly en- forfled. This will Include hospitals and off-shore gas plat forms . . 3. Customers (J>*-n,c.Tic) t (a) All orders are being approved by two people prior to order entry. (b) A list of approved PR users (top-up only) Is being prepared and will be circulated by October 25. (c) Field sales scrutiny of MIP runs Is requested (as per dielectrics). (d) Regional managers should report on unapproved fluid sales (as per dielectrics), (a) We still need field sales help in completing surveys on the applications of PR customers. 4. Customer Notification A mailing to all customers Is planned. This will Include: warning on PCBs; alternates to FR; non-fire retardance of T-55/ 56 and 77; conversion offer and procedure; positive approach to non-FR fluids; tighter maintenance guide for all fluids. 5. Labels New labels ore being printed. This will include a stronger statement on food and food-related uses. It will also HUNS 100056 -3- oover the return of used fluid for incineration. Process Fluids 1. Carbonless Carbon Paper No sales of chlorinated bi- or terphenyls. 2. Qye Carriers Aroelor 1221 replaced by Aroclor 1221B. (Aroclor 1221B is monoehlorobiphenyl whereas Aroclor 1221 did contain up to 25# PCB. We should males no big issue out of this with any customer. Currently Ciba-Qelgy is the only customer affected and this has been handled. Therefore any request for Aroclor 1221 will be filled with Apeelem cjiaMa*D without comment.) Cmu/n'l 6 3. No customer notification of Process Fluids l*s planned as a general mailing. Individual customer situations have been and will be handled separately. n*-'4 r In addition to the above, the following situations have arisen. 1. Requests by piper companies for information, help cn PCBs in recycled paper, We should refer companies to The American paper institute which is active in this area or to W. B. Papageorge. If any paper company wants methods for detecting PCB, Bill has a "Methodology Packet" that can be sent. 2. Requests from Monsanto customers that vie write letters stating vnetnor or net the products supplied by any of cur 01 visions are pOfl-l'ree. i Specialty Product Croup products: All products (except dielectric Ar )Clor/lnerteen/{>yranol; Aroclor 5400 and 500? series; Aroclor 1221B; Santovac 1 and 2; Pydrauls; Thermlnol FR series; and Turbinol 153) the regional manager should write the customer assuring him of the absence of PCBs. On product exceptions -- contact W. B. Papageorge. Products from other groups; Pass request to your counter part in tne region lor handling. 3. Pollution Control Procedures for Customers' Plants A draft of a bulletin cn this subject has been written and is being revised. MONS 100057 I have been Impressed by the efforts many of your men have put into turning this difficult situation around, if they have any suggestions where we can Improve on our procedures and policies or problems we are Ignoring we'll be only glad to hear from them. If they need specific help from anyone In St, Louis please let us know. I'll try to keep you as up to date as I can on future developments. Cummlng Paton os MQNS 10005b