Document XwYB2d1revy4krzNqynY4oey

AROCIOR Is a registered trade mail 0^21602 | TOWOLDMON0026243 WATER_PCB-00010712 0221603 MONSAHTO HOUSE 10*18 VICTORIA STREET * LONDON SW1 TOWOLDMON0026244 WATER_PCB-00010713 INTRODUCTION The Advantages of Aroclor 3 8 PROPERTIES "--Composition .................. " ' Physical Properties Viscosity Vapour Pressure Chemical Properties Electrical Properties Permittivity Loss Tangent D.C. Resistivity 6 " ** - 6 8 5 6 8 6 6 ? 8 CONSTRUCTION OF AROCLOR CAPACITORS Paper Assembly of Capacitors 17 17 PRODUCTION OF AROCLORCAPACITORS Earth Treatment Impregnation PERFORMANCE OF AROCLORCAPACITORS A.C. Capaoltors D.C. Capaoltors is 18 18 20 ' 20 20 TOXICITY AND HANDLING PRECAUTIONS 21 APPENDIX A Laboratory Measurements on Aroclor . APPENDIX B .. . r ________ ______ Compatibility Testing Method v * - - . 22 22 022160* ...... * ` * 23 TOWOLDMON0026245 WATER_PCB-00010714 The Aroclor* dielectrics are a range of chlorinated diphenyls pro duced by Monsanto for the manufacture of impregnated paper capacitors. These products are generically known as `askarels', that is, synthetic fire resistant insulating liquids which, if decomposed by an electric arc, evolve only non-explosive gaseous mixtures. The Aroclor liquids were first used in the United States in 1931 and to-day they are extensively used in the capacitor industry through out the world. Monsanto has been producing Aroclor at ltB Newport plant since 1951. There are three grades of Aroclor, identified by their code numbers: Aroclor 1242 (Commercially known as Trichlorodiphenyl) the most economically attractive, is essential for outdoor capacitors in a low temperature environment, but is the most difficult to handle in production. Aroclor 1248 (Commercially known as Tetrachlorodiphenyl) is a compromise between the economic advantage^ of 1212 and the ease of handling of 1254. Aroclor 12S4 (Commercially known as Pentaohlorodiphenyl) is the easiest to handle in production and is sometimes chosen for capacitors to operate in exceptionally hot environments, hut does not gain the maximum economic advantage. Advantages of using Aroclor Reduced size capacitors are possible for a given rating; fluorescent lighting units are a particular application in Which this is (xtlllsed. Reduced raw material cost arising from the smaller quantity of paper and foil needed in manufacture. * Aroclor is a Registered Trade Mark. 0221605 I TOWOLDMON0026246 WATER_PCB-00010715 Reduced labour content because of the fewer windings required. Increased through-put from a given plant capacity with existing labour force. Higher stress operation of capacitors is possible because of a more uniform permittivity in the capacitor. Longer life capacitors are produced because of the high stability and resistance to oxidation of Aroclor. Small fire hazard because Aroclor is fire-resistant. ! TOWOLDMON0026247 WATER_PCB-00010716 Values for the most Important properties of the Aroclor dielectrics are given In the Table. Typical properties of the Aroclor dielectrics (These values do not constitute a specification> Property Aroclor 1242 Aroclor 1246 Aroclor 1254 Relative Density at 20/20*0 Pour Point ("C) Vlecosity at BO'C (cS) Coefficient of expansion *C Specific beat at 75C (Jig eC) Thermal conductivity at 75C (W/m BC) Evaporation loss (%) (2 h at 125*C) Flash Point (eC) ASTM D93/62 Fire Point Refractive Index n^ Inorganic chlorides (ppm) Add number (mgKOH/g) Water oontent (ppm) Permittivity at 20C and 60 c/a Permittivity at 100C and 50 c/s Doss tangent at 100'C and 50 c/s D.C. resistivity at 100*C and 500 V/mm after 1 min. electrification (TQ cm) Pielectrlo strength at 20C (kV) (B.S. 146:1959) 1-385 -19 35 0-00076 1-24 01039 012 154 (min) None 1-6240 0.1 (max) 0-01 (max) 85 (max) 6-97 4-83 0-016 1-456 -7 62 000074 11$ 01003 007 164 (min) None 1-6295 01 (max) 0-01 (max) 85 (max) 658 467 0-015 1-549 +10 102 0^X1069 i-iw OWI43 0 03 201 (min) None 1-4370 0-i (max) 0-(jl (max) 35 (max) S-M life 0010 60 60 (min) 7-0 60 (min) 6-0 70 (min) Composition Aroclor Is made by the chlorination of diphenyl to predetermined Chlorine contents which are Indicated as a percentage by the last two digits In the code number e.g. Aroclor 1248contains48% chlorine by weight. Each Aroclor contains a range of chlprodiphenyls with differing numbers of hydrogen atoms substituted py chlorine, and in each of these chlorodlphenyls there Is abundant Isomerism. Physical properties Viscosity Tho viscosity-temperature characteristics of the Aroclor liquids are shown in Figure 1. It can be seen that Aroclor 1254 (s the most viscous at all temperatures and Aroclor 1242 the least; The differences between the three grades are greatest at lower tempera- 0221607 6 TOWOLDMON0026248 WATER_PCB-00010717 ture and become less as the temperature Is raised. As previously explained, Aroolor consists of a number of homologues and conse quently each grade does not have a sharply defined melting point, but remains liquid over a wide temperature range. Instead, their Viscosities Increase smoothly but sharply as the temperature Is reduced. Aroclor 1242 has the lowest pour point of all three grades. Vapour Pressure It can be seen that Aroclor 1242 has the greatest vapour pressure at a given temperature and Aroolor 1254 the least, and this needs to be considered when deoldlng the temperature of Aroclor during degaslfloatlon and Impregnation. The vapour pres sure of Aroclor varies with absolute temperature according to the usual logarithmic law. The variation of the vapour pressures of the Aroolor dielectrics with temperature Is shown In Figure 2., Chemical properties The chemical Inertness of Aroclor Is outstanding. The liquids are not oxidised by exposure to air or oxygen even under extreme condi tions of temperature and pressure, nor do they react with moisture. When subjected to a bomb test at 1OT In oxygen at a pressure of 250 p.s.i.g. (17 kg/cm), there was no evidence of oxidation as Judged by development of acidity or formation of sludge. They can withstand many years of service in electrical equipment at high temperatures without oxidation. Aroclor Is manufactured to a rigid specification ensuring a low initial value for free acidity and free chlorides. Teste have shown that these low values are maintained even when the liquids are heated for prolonged periods In the presence of air and moisture at temperatures of 100C. Aroolor 1242 is slightly sensitive to ultra-violet light, which can result in the formation of traces of ionic contaminants. The other grades are relatively unaffected by exposure to light. Aroolor undergoes no decomposition at temperatures up to 175'C. At much higher temperatures, or when subjected to arcs, the prin cipal decomposition products are carbon and hydrogen chloride. Laboratory tests and practical experience hav( shown that phosgene, chlorine, or hydrocarbons are not formed as decomposition products of Aroclor. Electrical properties The laboratory methods used to measure the electrical properties of tbo Aroclor dielectrics are described In Appendix A. Permittivity (Dielectric `constant') The permittivity ofAroolor Is high er than that of mineral oil, which accounts for the size reduction 6 TOWOLDMON0026249 WATER_PCB-00010718 and Increase in stress that is possible. Stresses of 15 to 17 V/pm are common with Aroclor and higher values are reported. Since chlorinated diphenyls are polar compounds, their permittivi ties are highly temperature-dependent. This Is illustrates in the upper part of Figure 4, which shows the variation with temperature of the permittivity of each of the three grades of Aroclor. These reading; were taken at a frequency of60 c/s and an electrio stress of lV/pm. At the lowest temperatures, all three grades have a permittivity of about 28, since, because of the very high viscosity, there is no con tribution from dipole orientation polarizability. As the temperature is Increased, the permittivity begins to increase when the Viscosity becomes sufficiently reduced to allow the moleoular dipoles to orientate themselves in the alternating electric field. The tempera ture at which this Increase in permittivity begins is dependent upon both the grade of Aroclor, being lowest for Aroclor 1242, and the frequency of the applied field. As the temperature is further increased, the permittivity passes through a maximum, and then decreases. This decrease in permit tivity with increase of temperature is due mainly to the disturbance of the alignment of the dipoles by thermal agitation. The maximum permittivities attained vary with the grade of Aroclor, being great est for Aroclor 1242 and least for Aroclor 1254. With Aroclor 1242 the permittivity of this series reaches a maximum, and a further reduc tion in chlorine content causes a reduction in permittivity, as Bhown in Figure 3. Although the permittivity ofAroclor 1242 is of ajilgh order,continued research on these products has revealed the possibility of obtaining even higher permittivities with this class of material. It is likely therefore, that tbe final word has not been written on this Subject and that improved products will become available in this field in the course of the next few years. Loss Tangent The loss tangent, or power factor, of Aroclor is also highly temperature dependent. This is Illustrated in the lower part of Figure 4, which shows how the loss tangents plotted here on a logarithmic scale of each of the three grades of Aroclor vary with temperature. The curve for each grade of Aroclor consists of a peak due to absorp tion associated with the transition In pormlttlvlty, followed by a region where the loss tangent steadily Increasos with temperature. In this latter region, the loss tangent follows the Increaso in fluidity with increasing temperature and Is highly dependent u(>on the purity of tho Aroclor. The temperature at which the peak occurs is about 19* below the pour point. 0221609 1 | TOWOLDMON0026250 WATER_PCB-00010719 The loss tangent of Aroclor Is greater than that offresh mineral oil, hut by selection of a paper of lower density the loss tangent of the Impregnated capacitor can be minimised without sacrificing the economic advantages. Furthermore, the Internal temperature does not rise beyond acceptable values. D.C. Resistivity The values quoted in the table are typical for Aroclor as produced, but they can be Improved by vacuum dehydration and values of 20 to 50 T fl cm at 100C are oomipon. The values for Aroclor 1242 and 1248 are lower than 1254 because a given amount of contamination reduces the d.c. resistivity mere with a liquid of lower viscosity and higher permittivity. The variation of the d.c. resistivity of the 3 grades of Aroclor with temperature Is shown In Figure 6. TOWOLDMON0026251 WATER_PCB-00010720 8000-I 7000-1 6000-1 KINEMATIC VISCOSITY (S) , I I I I I I----------1----------1----------1 |----------1----- ' | | 0 10 20 20 40 SO 60 70 80 90 100 110 120 TEMPERATURE (C) Figure 1 The viscosity-temperature characteristics of the Aroclor dielectrics oe?u>ii 9 TOWOLDMON0026252 WATER_PCB-00010721 T rO O * UtESSBOE (ton-) WATER_PCB-00010722 TOWOLDMON0026255 WATER_PCB-00010724 - ** >X nmX -/ >' I--------------------1--------------------1------------------- 1-------------------- 1------------------- 1--------------------1--------------------1--------------------1--------------------1--------------------1 -SO -60 -SO --20 0 20 <0 60 SO 100 120 TEMEERATURE("C) 0221615 Figure 4 The variation of the permittivity and dielectric loss angle of Broclor with temperature TOWOLDMON0026256 WATER_PCB-00010725 Y 919NC RESISTIVITY I Figures The variation of the DC resistivity of the Aroclor dielectrics with temperature I I TOWOLDMON0026257 WATER_PCB-00010726 Figure 8 The permittivity of paper Impregnated with Aroclor 0221617 , "I TOWOLDMON0026258 WATER_PCB-00010727 figure 7 The Monsanto dielectric test cell IB TOWOLDMON0026259 WATER PCB-00010728 CONSTRUCTION OF AROCLOR CAPACITORS Paper Krart paper is strongly recommended since It has nearly 6 times the acid neutralising properties of rag tissue. The permittivity of Impregnated paper depends upon the density of the paper as well as the permittivity of the Impregnant. This rela tionship is shown in Figure 6 for the S grades of Aroclor and for mineral oil, the values being calculated at a temperature of 20C. Since paper impregnated with Aroclor 1242 has the highest per mittivity, the least area of windings Is needed to obtajn a given value of capacitance and the greatest economy Is obtained. It Is advantageous to use low density paper since It has bgen shown both theoretically and practically that such paper gives the least dlelectrlo loss In a capacitor. This effect arises from the distribution of electrical stress between the cellulose fibres and the impregnant and Is In addition to, and Independent of, any losses In the Impreg nant Itself. Most manufacturers of capacitor tissue are familiar with Aroclor and have developed suitable grades for use with It. Assembly of capacitors It cannot be emphasised too strongly that every material that comes into contact with Aroclor must be carefully checked foi[ compati bility. Aroclor Is a good solvent for many thermoplastics and elastomers and the resulting solution has a high dielectric loss tangent. Materials which must be considered Include the major Insulation, the lead-through Insulators, any means of scaling the container and the residues from the manufacturing process e.g. fluxes left after soldering. The windings should be sealed with a suitable adhesive suoh as gum arable or Gloy. Connection tags If of copper should be tinned, other wise stainless steel can be used. Soldering should be kept to a minimum and where possible the special cored solders which have been developed by manufacturers for use With Aroclor should be employed. Opaque bushings must be used booause of the slight light sensitivity of some grades of Aroclor, particularly Aroclor 1242. 022161* 17 TOWOLDMON0026260 WATER_PCB-00010729 PRODUCTION OF AROCLOR CAPACITORS Although the production of Aroclor Impregnated capacitors Is generally similar to that of oil Impregnated units, and similar plant , may be used, there are several differences In detail and these are described in the following sections. If an oil plant is to be changed to Aroclor, no special cleaning is neoessary, although it is advisable to rinse the plant first with Aroclor which is subsequently discarded. It must be noted at this point and always borne in mind that Aroclor has a very considerable detergent effect. That is to say that since the density is neatly twice that of oil, any dirt existing in the system will be washed out due to the greater density effect of the Aroclor. Earth treatment The main difference between Aroclor and oil capacitor impregnation plant is the earth treatment section. Aroclor, as received in drums, is suitable for filling into capacitors after vacuum treatment but it is generally advisable to have an earth treating facility available to treat any Aroclor which could become contaminated during the process cycle. For example if capacitors are filled by a flooding technique, then Aroclor which is unused and which is returned to the system will be found to be Blightly contaminated and earth treatment is advised. For this to be fully appreciated, it must be realised that the Aroclor liquids are more susceptible to contamina tion than their mineral oil counterpart. Because of their higher solvent action and higher permittivity, the contamination level which would be acceptable in mineral oil and which is commonly encountered in an impregnation plant will be unacceptable for Aroolor. The earth treatment can be carried out in two principal ways. In the first place the earth is contained in a column and the liquid is circulated until the contamination is removed. Alternatively, activated earth is added to the liquid in a container and it is stirred to ensure Intimate mixing and then the earth is filtered through a normal paper filter. In both cases either Fullers' Earth or activated alumina may be used and eaoh must be thoroughly dried. It has been found by experience in laboratory tests that the earth may be pacified by heating to excessive temperatures, and the optimum treatment is about 150'C for 6 hours. The activated . J8 02nt>2 TOWOLDMON0026261 WATER_PCB-00010730 .. , ; i .. :. ,. _ , ;, :' .. .; . . ;, |, ' , . j : , ' 1| :; . : ;j .; I material is then added to the Aroolor to bo treated at a level of .2% - 2V. by weight. The use of freshly activated earth gives a con trolled high quality of material from the treatment stage, However, there still exists the problem of separating the oarth and here the column technique has a considerable advantage, since circulation through the column does not necessitate further filtration. This method has the disadvantage that the column gradually becomes less aotive during its life and there is net always the same degree of control over the treatment process. Impregnation It is customary to store the capacitor liquid in a large tank the size of which depends on whether the material is delivered in drums or tankers. It is strongly recommended that these storage tanks be lagged and heated since at low temperatures difficulty would be encountered in pumping the Aroclor 1254 and ]n certain extremes of temperature even Aroclor 1242 can become unpumpablc. After transfer from the storage tank the liquid is first earth treated and mixed with any unused liquid drawn back from the Capacitor impregnation tank, if applicable. The treated liquid is then sub Jected to vacuum drying and de-gassing in exactly the same way as with mineral oil and after this process it is passed to the final storage vessel where it is held before being passed to the impregnatlon section. Aroclor capacitors may be vacuum impregnated by a manifold technique in which the liquid is piped Individually to each capacitor can and this is perhaps more suitable for the larger power factor correction capacitors. Alternatively, they may be filled by a flooding technique which is more applicable to the smaller fluorescent lighting capacitors. Here the capacitors can be loaded in wire cages and completely Immersed in the liquid in the same way as with mineral oil. For the actual Impregnation cycle the following temperatures are recommended: Aroclor 1242 70- 80*0 Aroclor 1248/1254 00-100'C The lower impregnation temperatures are recommended for Aroclor 1242 since as this process is carried out under vacuum the losses will be greater with a liquid which is more volatile. After the impregnation cycle has been completed the vessel should be cooled to below 50C before being opened ahd this is to avoid the unpleasant fumes of Aroclor escaping into the work-shop, The capacitors should then be sealed a3 quickly as possible and degreased before final painting and testing. . Toxicity precautions and the handling or Aroclor is dealt With in a separate section but workers handling the liquid, or capacitors coated with it, are advlBed to wear rubber gloves or use barrier cream. 19 TOWOLDMON0026262 WATER_PCB-00010731 PERFORMANCE OF AROCLOR CAPACITORS A.C. capacitors at If a capacitor is continuously energised before and whilst subjected low ambient temperatures to a low temperature environment it operates satisfactorily because the heat produced in the dielectric balances the heat lost from the case. A self-compensating process exists such that if the tempera ture of the dielectric falls the losses Increase, and more {heat is generated to establish a new equilibrium. Tests have shown that a capacitor Impregnated with Aroclor 1254 can operate continuously energised in ambient temperatures down to -60*0, and it was found that such capacitors satisfactorily survived Whilst installed out doors during the winter 1962-3. If, however, a capacitor is subjected to a low temperature environ ment first and then energised It may be damaged by discharges occurring in voids formed by the contraction of the dielectric before it has time to heat up sufficiently. Cases when this might occur are in street lighting capacitors during winter, or capacitors installed in a plant that has been shut down during winter holiday periods. For this reason, the following minimum ambient temperatures are suggested for the 3 grades: Aroclor 1254 - 7C Aroclor 1248 -28"C Aroclor 1242 ~45C For operation at still lower temperatures a blend of Aroclor 1251 and trichlorobenzene has been used. D.C. capacitors Aroclor is also used in d.c. capacitors but it hps been found that at the high stresses used the service life of the capacitor tends to be reduced if the working temperature is raised above 400. This can be . overcome by using stabilisers in the Aroclor to overcome tpe slight electrochemical degradation which tends to take place, (generally the effect is proportional to the quantity of stabiliser useS and up to 1 per cent of anthraqulnone, or 1,8 dlchloroanthraquinone, and 2 per cent of azobenzene have been used. 20 0221622 | TOWOLDMON0026263 WATER_PCB-00010732 TOXICITY AND HANDLING PRECAUTIONS Aroolor made by Monsanto has been need for over S3 years without causing any toxic effects, but It must be handled with care. These precautions should be observed: 1 Avoid shin contact. Protect the hands, preferably by oil-resistant gloves. 2 If shin contact should occur, wash off with soap and water. 3 If hot Aroclor must be handled In a closed or confined area provide exhaust ventilation or wear an approved respirator. 4 If Aroclor gets in the eyes, flush with large amounts Of water. In the event that Irritation persists refer the patient to a Physician. 6 Infrequent exposure to Aroclor vapour will not cause any 111 effect, but prolonged exposure to a high vapov)r concentration Bhould be avoided. If these precautions are neglected acne may develop and excessive exposure may cause liver damage. OZ21623 21 J TOWOLDMON0026264 WATER_PCB-00010733 LABORATORY MEASUREMENTS ON AROCLOR The Monsanto There ere many test cells available for measuring the electric dielectric test cell properties of liquid dielectrics, but since most of these were de signed for use with mineral oil, Monsanto has designed a test cell especially for use with Aroclor. This design or cell is used In our laboratories and Is available for sale to customers. It is essentially a three terminal cell with cylindrical stainless steel electrodes separated by a 1 mm gap. Figure 7 shows details of the construction of this cell. The procedure for Great care must be taken to ensure careful cleaning for Aroclor cleaning and tilling the cell measurements with this or any other cell. The Monsanto cell is designed for easy cleaning and accurate assembly. The Monsanto cell is first cleaned by a series of thorough washings as follows: 1 A wash with benzene 2 A thorough washing with detergent and hot tap water 3 Repeated rinsing with hot tap water 4 6 rinses In distilled water 6 2 rinses In analytical grade acetone During the wash with the powder detergent a soft hair brush is used and all parts of the electrodes are thoroughly brushed. The cell Is then dried In an air oven at 130"C for 30 minutes. Finally It Isrlnsed twice with the Aroclor to be measured before filling a third time, when the electrical measurements are taken. Measurements The temperature at which the electrical properties are made is measured by a thermometer resting in the central well of the cell. For routine tests a temperature of 10O"C is used. Permittivity and loss tangent are measured firt with a transformer bridge at a stress of 1 V/|im and at mains frequency of SO c/s. D.C. resistivity is then measured with an electronic megohmeter one minute after the application of a stress of 0 5 V/|im. If repeatod readings of d.c. resistivity are performed on the Bame quantity of Aroclor in the cell, a gradual increase is noted. It Is therefore recommended that If a repeat measurement of resistivity Is re quired, the cell be emptied, thoroughly cleaned, and then refilled. 22 0221620 iI IJ TOWOLDMON0026265 WATER_PCB-00010734 Process control measurement* For operating an Impregnation plant, It Is convenient to be able to measure the electrical properties of the Aroclor without the neces sity of taking samples, and a cell can be Incorporated in the system e.g. In a flow line. It should be arranged that there Is a turbulent flow of Aroclor through the gap between the electrodes except when a measurement is being taken so that adequate cleaning of the electrode surfaces occurs. To Obtain the same value of d.c. resis tivity with a plant cell and with a laboratory cell it Is necessary for the Aroclor to be (1) stationary whilst the measurement Is made, (2) subjected to the electric field for one minute, and (3) at the same temperature. COMPATIBILITY TESTING METHOD Procedure If the material is available in a laminar form or is a surface Coating, apiece 25 mm square is cut from a sheet. Other materials are selected so that the sample taken Is present at the samp concentration as in the finished article. The sample Is put into a glass jar that has previously been cleaned and dried in the following sequence *. 1 Wash in benzene 2 Wash with hot water and detergent 3 Six rinses with distilled water 4 Rinse twice with analytical grade acetone 6 Dry in an oven at 130O for 1 hour To this jar, and to a similar one without a specimen within It, are added 60 ml of Aroclor. The jars are then closed with ground glass lids and aged in an oven at 1000 for 7 days. After ageing, the jars are removed from the oven and the electrical properties of the Aroclor in both the specimen Jar and the control Jar are measured at 100"C according to the method described in Appendix A. The specimens are examined for swelling or other signs ofdeterioration, and any colour change of the Aroclor Is noted. Results The Aroclor In which the sample has been immersed must not ex perience a decrease In resistivity below 10 terohm cm. Information on materials which have been tested Is available on request. 0221625 23 J TOWOLDMON0026266 WATER_PCB-00010735 on Monsanto 000033$ CM _M_ fH30Fv SC- 02216Z6 TOWOLDMON0026267 WATER_PCB-00010736