Document Xnm3Z3OXM7pOMYmwQvq6bwXK

' co e. *x. crr^ SC-DP-00052 DUP 0 9 0 9 1 9 2 .0 0 1 Asbestos Issues Comittee Function To: Recognize emerging asbestos (and other respirable fiber) issues and see that those with hide impact are ADDRESSED In a Way That: * Considers health, regulatory, liability and cost CONCERNS Is coordinated with the Corporate Asbestos Program Involves participation from Medical, Industrial Hygiene, Legal, Public Affairs, Employee Relations, Workmans Compensation, Manufacturing and other PERTINENT PERSPECTIVES So That: Employee health, regulatory, liability and other concerns are addressed in a cost effective manner DUP 0909314 Asbestos Issues Cowittee S. VI. Dixon - S&OH - CHAIR A. S. Berg - S&OH/Polymers J. 6. Gleich - Consol R. E. Kasch - Human Resources L. A. Legendre - Conoco J. F. McAllister - External Affairs C. P. Mihal - Fibers W. J. Mottel - S&OH L. J. Natale - Automotive Products - TIMS R. S. Price - Environmental J. L. Riddle - N. E. Region/Asbestos Program Manager J. D. Shomper - Legal - Litigation R. R. Strocko, M) - Medical P. M. Truax - Workers Compensation J. T. Williamson - Legal - Compliance DUP 0909315 Asbestos Issues Cowittee - Recent Activity EQC? Guideline II-I issued "Management of Materials which Contain Asbestos or other Respirable Fibers" Global asbestos Engineering Standard (revised S4T) prepared Global NARF S&OH Guideline (9.10)/Engineering Standard (S15T) PREPARED S&OH Bulletins issued on OSHA Compliance (smoking, excursion limit) and EPA NESHAP revision Submitted comments on OSHA Remand Issues Rulemaking Medical Guideline 5 Revised Standard ARC terminology and diagnosis wording Use of CT scan to obtain accurate diagnosis - borderline ARC Clarify DuPont requirements versus OSHA requirements Provide clearer guidance on who needs DuPont or OSHA Program Asbestos Issue Manager (s) established to blitz management issues Much valuable work begun - closure needed DUP 0909316 "ASBESTOS"STAKE IN DU PONT Employee Health Removal Cost Liability Management DUP 0909346 3L.fi- PROPOSAL | "Asbestos" is an issue for which ERC should have value. Form Asbestos Focus Group (utilizing Asbestos Issues Committee and ERC Liaison). Review "Asbestos" issues outlined by A.I.C. and determine: - if issues outlined are the right ones to work on. - If groups identified to lead particular issue are right groups. DUP 0909347 V ASBESTOS ACTIVITIES! CORPORATE (ERC/A1C) Develop policies, practices, etc. for Du Pont. Q Develop inspection/assessment guidelines for comprehensive program (document practices and options for EPA Neshaps compliance). Maintain network of resources throughout the Company. Redefine and continue lab QA/QC program. Maintain Corporate Respirable Fibers System. Update businesses/regions/sites on changes in regulations and best practices. MLS Q Develop removal/contracting best practices - administration guideline. Q Develop integrated quality/cost abatement supplies program. Review and resolve contractor liability insurance issue. BUSINESS Provide consultation and on-site inspection/management assistance to sites (options: Fibers, TIMS, MLS/vendors). SUE Manage their own own asbestos program and coordinate training specific to their site. DUP 0909348 PLANNING FOR THE INSPECTION REVIEW OF PREVIOUS INSPECTION RECORDS AND BUILDING DRAWINGS 1. Scheduling of the Inspection 2. Obtaining Access 3. Building Record Review 4. Probable Homogeneous Areas According to Drawings 5. Consultation with Maintenance and Operations Personnel 6. Previous Inspection and Sampling Reports 7. Previous Abatement Records 8. Maintenance Records 9. Exclusions for Previously Performed Inspections (763.99) 10. General Planning Comments OUP 0909465 1. SCHEDULING THE INSPECTION Nights Weekends Business hours School hours Contract DtJP 0909466 2. OBTAINING ACCESS Locks (keys) Ladders/Lifts (Safety!!) "Unused" or "Unimportant" spaces Inaccessible spaces Unknown spaces (dimensional accountability) Contract DUP 0909467 3. BUILDING RECORD REVIEW Drawings Specs Construction contract Bid documents (alternates) Change orders Pay requests (dates) Construction field reports Maintenance records Original construction Additions/Renovations DU? 0909468 4. PROBABLE HOMOGENEOUS AREAS ACCORDING TO DRAWINGS Design drawings Contract document drawings As-Built drawings Shop drawings (Hyatt disaster) Floor plans Sections Finish schedule Mechanical/Plumbing/Electrical Structural OUP 0909469 5. CONSULTATION WITH MAINTE NANCE & OPERATIONS PERSONNEL Maintenance procedures Maintenance schedules Operations procedures Operations schedules M/P/E design/iocation/operation "Unused" or "Unknown" spaces Passed ACM disturbance Current ACM procedures O & M procedures? Management sophistication Employee sophistication DUP 0909470 6. PREVIOUS INSPECTION AND SAMPLING REPORTS Location and pattern of samples? Number of samples? Composition of samples? Condition of ACM? Type and use of ACM? Other data applicable to AHERA Assessment categories and your assessment methodology? Must be field verified Do exclusions apply? Are some samples applicable? Must the entire survey be redone? How was nonfriable ACM addressed? Was any suspect ACM indicated? DUP 0909471 7. PREVIOUS ABATEMENT RECORDS Location Methods Disposal Clearance criteria Worker training Residual contamination? Urgent response action needed? Special cleaning needed? DUP 0909472 8. MAINTENANCE RECORDS HVAC filter changes TSI disturbance - V. *t' . ' " O & M procedures? Schedules Routines Emergency . DUP 0909473 9. EXCLUSIONS FOR PREVIOUSLY PER FORMED INSPECTIONS (763.99) For homogeneous areas or sampling areas Friable ACBM was identified Nonfriable ACBM was identified No ACBM is present (inspector) No ACBM is present (lead agency) Suspect ACBM is assumed ACM All ACBM has been properly removed No ACBM specified or used Must assess friable Has nonfriable become friable? Must assess newly friable READ THIS SECTION !! DU? 0909474 10. GENERAL PLANNING COMMENTS 2 major divisions of suspect ACBM Accessible Space Inaccessible Space Assumptions Building conditions Survey Conditions DU* 0909475