ABERDEEN CHEMICAL PLANT
A
INDUSTRIAL HYGIENE MONTHLY REPORT
I. Routine Chemical Dosimetry
Month: December* 1984 Date of Report: 1/29/85
All Sample Results
Chemical
VCM Lead Total Particulates
< PEL No. %
85 95.5 7 100.0 5 100.0
> PEL (OVEREXPOSURES) No. %
4 4.5 0 0.0 0 0.0
Overexposures
Job Class
Exposure
Source
Reactor Operator
1.9* ppm, VCM
Employee overexposed while washing out the new unit chemwash tank.
Yard Operator
2.0* ppm, VCM
Employee overexposed while unloading VCM railcars.
Reactor Operator
1.7* ppm, VCM
Employee overexposed while locating leaks at 903 recovery compressor* the new unit fresh VCM filter pack and atop 741 reactor.
Electrician
1.2** ppm, VCM
The employee was overexposed while greasing pump drive motors in the new unit. The specific cause is not known. However, an upset condition involving draining of the chemwash heater is suspect.
Respiratory protection was worn. Respiratory protection was not worn.
II. VCM Dosimet
Two major changes were made in the program:
Vinyl department shift workers are now being scheduled by job classifies tlon instead of by name as in the past. The scheme also results in a more random schedule with resnect to time of day and day of week.
B. Dosimetry equipment handling methods were simplified by reducing the num ber of people who handle each sample. All REAL badge carbon handling is now being done by lab personnel.
-
..................... --
....
------
.. ,, --
-- -
VAB.0001040184
t
4
Industrial Hygiene Monthly Report Page 2
IV. Ventilation Measurement The Anemotherm model 60 "hot-wire" velometer was returned to the factory for repair^
Jerald V. Uptain rah Distribution: JF, JWW, DWH, PJK, WFH, CRS, RAF, AHS, JRW
Tom Grumbles, J. R. Drumwright, M.D. - Houston
A
/
VAB.0001040185
ABERDEEN CHEMICAL PLANT CHEMICAL DOSIMETRY TRENDS
A
v9-
PEL
100
VCM
0
100
r . -- ............... 1 1B.UT _ ..J. .. f
Lead
*&
w
II ;
\
i .. ........ .
..
|
J p I 1 1
0 ..................
-..... ,.-,1.................... ....
V\\
/f 1
f'
\ i; M *
!\
/
1 I
*^
1
T'
|
' J1 h
|
- - --.... ._____
f'' lr
: t"__ 1
b
1i i;
l
1|
F-
i\
-\ ^
if \I
\ ^Sf
% \
4
*H
n
\ \
,
i b
T 11
... 1
-- *- | ,
--: ! ! 1 J
;;l_________________ ........ !. 1 'll it,
1 1 .... 1s i :i
J 1 ii
\ iI!
^ <;--------' '< |
X!
! J ....
' i--------------------------------
1---------
T.^4, --
j ___ ^ 1 1|
'I [
1
--------- !---- 11
ft '
ii1
T
ii s i 1 i t
\ rI !
!(;
; 1 ! I--------- 111!
--1 1i 1
'* * ______: - .
*
!---------- :--------- !
i+ j1 11 i1 l______: .._! : :----------
r
f!J
'!--------- ;--------- !--------1---------
-------- 4 -j--------- 1
1 " tl J
i t"
----------f---------
1 1 ' 1i 1 1 *i > i* --1> i !
--------- |--------- 1--------- --------- 1--------- !---------1
ii:
, --------- 1--------- j--------- 1--------- ;--------1--
' "t ______i______ 1_____
fl--,
| ,i1_______
:
i
100
Total Particulates
0
VAB.0001040186
mmm
MUM
ABERDEEN CHEMICAL PLANT INDUSTRIAL HYGIENE MONTHLY REPORT
Month: November Date of Report: 1/04/85
Routine Chemical Dosimetry
All Sample Results;
Chemical
VCM Lead Total Particulates
PEL No. %
92 97 18 95
6 100
Overexposures Job Class
Exposure
General Mechanic
1.1** ppm , VCM
General Mechanic
2.0** ppm, VCM
Yard Operator
4.6* ppm, VCM
Color Weigh Compounder 56.6* microgram lead/m
S
No.
3 1 0
PEL Overexposures
%
3 5 0
Source
Employee overexposed while welding cracks in the dry blend "gump" screener bowl. The specific cause of the overex posure has not been identified.
The employee spent his entire work period doing insulation work in the new Vinyl unit. The specific cause of his overexposure has not been identified.
Employee overexposed while hooking/unhooking VCM railcars.
Employee overexposed while weighing up micro quantities of Epistatic 112 and Epistatic 122 inside the color weigh room.
* Respiratory protection was worn, ** Respiratory protection was not worn.
VAB.0001040187
*
Industrial Hygiene Monthly Report ^Page 2
Area VCM Sampling
Seven, 8h hour area VCM samples were taken inside the V-10 building during
the reclaim of "pond" resin using REAL "minimonitor" badges. The results (below) demonstrate that while VCM levels exist during the operation, they are below the "Action Level" of 0.5 ppm, and well below the permissible exposure limit (PEL) which requires respiratory protection. However, the person observing pond resin pump-up should continue to wear a respirator while in V-10.
Sample Location
First floor of V-10, column between and just north of dryers
Sample Result, ppm, VCM 0.1
First floor of V-10, blower just north of east dryer
0.1
First floor of V-10, column between and just north of blend tanks
0.1
First floor of V-10, between 551 and 553 blend tanks
0.1
Above and between blend tanks, V-10
0.3
V-10 centrifuge deck at airline station just northwest of 550 blend tank
0.4
Just above V-10 east dryer line Sweco screener.
0.4
Equipment Calibration
The fourth quarter calibration of the precision rotameter used to measure
Bendix BDX 44 air pump flowrates was completed using a large "bubble tube" as a primary standard.
Area Ventilation Checks
The fourth quarter check of lab ventilation hood velocities and flow rates
was completed. The results were reported to the lab for correction of one deficiency found.
rah
cc: JF, JWW, DWH, PJK, WFH, CRS, RAF, AHS, JVU, JRW Tom Grumbles, J. R. Drumwright, M.D. - Houston
m
4
-
'
PEL VCM
ABERDEEN CHEMICAL PLANT
-- II--PM-- " I
Ml
I
CHEMICAL DOSIMETRY TRENDS
100
s b
Total Particulates
1 h
i ii *4 i iF 1 T
0\
i| i
i >
' 1: 1
!j !
b4 bP
-
b T\ J *
i
1!
li <-
ii [
f 1 i. 1 i':
" |
J
| -t J* -,
.T
!
-
"t>
; <
H \
j
! <i
' :! ;! ;\ ^ :f
p 1 T I 1. -4
?:i T\l !
1
41
h[
i*
i
:1 --. * k+ . j
ri
:
f if'
J
j
f \ ... 1 \
: "1 k
* f j
j
i t 1 i
;--------\ ^ ii
!j[i
: - i- !
!'ir
____ l__ . i____ J *[ "1{ f*
1. 4
ii
1 M1 -: :i
1 1
1
L 1 >
1
\:;
1 ------- ,------ 1----j--------
i! j ' i
i
';1 ' i
:1
4 !l
[l
J
11 i
i *^ , Lk
!1 1
i ..
L
i.
ib
11!
1
l i
j. 1
------- rI
_____ _____ i____
f i
--------- 1-- --- "p;----
i: ii -------r------ ---------*'------- ;*------- !i--
i =i !
1*
1
b < i
,' 1 P
L'
!
L----. ----1; 1
i;
ri
,
1
t!
j-
* TM` 'tf" 1 1
1 ,"1 "*
i1
'
VAB.0001040189
mm mmmmmm
*
ABERDEEN CHEMICAL PLANT INDUSTRIAL HYGIENE MONTHLY REPORT
Month: October Date of Report: 11/15/84
Routine Chemical Dosimetry All Sample Results:
Chemical VCM Lead Total Particulates Overexposures Job Class Reactor Operator
<
No.
88 32
3
PEL
%
95.7 100 100
Exposure 23.5* ppm. VCM
Reactor Operator
h 2.6* ppm. VCM
Reactor Operator
16.1* ppm. VCM
Instrument Technician
7.6** ppm, VCM
Respiratory protection was worn. Respiratory protection was not worn.
X PEL Overexposure
No. %
4 4.3 00 00
Source
Employee overexposed while changing VCM filters in the new unit.
Employee overexposed while rinsing out the chem wash tank.
Employee overexposed while changing VCM filters in the new unit.
Employee overexposed while changing a sightglass on the south knockout pot in the new unit recovery area.
mm mrnmmmrnmm
wmmmm
mmmmm
VAB.0001040190
Industrial Hygiene Monthly Report Page 2 OSHA Hazard Communication Ru1e An inventory of chemicals used in the plant was conducted. This will be the basis of the initial list of hazardous plant chemicals required under this OSHA standard. Respiratory Protection A report on the third quarter audit of the plant respiratory protection program was issued. The Aberdeen plant respirator training class outline was updated and copies made available for department use.
Ginny Belk, R.N. Plant Nurse cc: JF, JWW, DWH, PJK, WFH, CRS, RAF, AHS, JVU, ORW
Tom Grumbles - Houston J. R. Drumwright, M.D. - Houston
I * VAB.0001040191
l
*'
ALiEKDEEN CHEMICAL PLANT CHEMICAL DOSIMETRY TRENDS
Total Particulates
f S1
VAB. OOO1040192
'T- -
------------,,
.
ABERDEEN CHEMICAL PLANT
INDUSTRIAL HYGIENE MONTHLY REPORT
Month: September
Date of Report: 10/25/84
4
Routine Chemical Dosimetry
All Sample Results: --
Chemical
-
< No.
-
PEL %
-
> PEL Overexposures No. %
VCM . Lead, ` Total' Particulates .. _
- Qverexposures
86 95.6 8 80 5 100
^
4 2 0
4.4 20
0
Job Class
Exposure
Source
Lead Operator
.. -J
General Mechanic, .
2.2**ppm, VCM "
r 'V
1.5**ppm, VCM
Employee overexposed while. working in the vicinity of a VCM filter pak filter change in the new unit.
_
Employee overexposed.while changing 743 reactor chem wash sprayhead.
Yard Operator
1.3*ppm, VCM
Employee overexposed while
hooking/unhooking VCM railcars at the VCM tank farm..
Yard Operator
1.3*ppm, VCM --
Employee overexposed while
hooking/unhooking VCM. railcars
at' the VCM tank. farm.
"
Color Weigh Compounder , 68.8* microgram
Lead/m
^
......
Employee,.overexposed while doing his routine job of color weigh-up. No specific cause for the overexposure has been identified. The two lead materials handled were Epistatic 112 and Cyastab 988.
Line I Compounder
139.1* microgram Lead/m
Employee overexposed while charging Epistatic 112 into blends of 34431 Natural on Line I.
* Respiratory protection was worn. ** Respiratory protection was not worn.
%
jr
VAB.0001040193
>
- _ -Industrial Hygiene Monthly Report Page 2
I
Respiratory Protection
An audit of the plant respiratory protection program was conducted. A
report on the deficiencies found, along with the associated, corrective measures, will be issued during October.
Area Ventilation' Checks
The third quarter check of lab and compound ventilation hood velocities
and flow rates was completed. The results were reported to the two
departments for correction of the deficiencies found.
".+ r
T
Material Safety Data Sheets
Material Safety-/Data Sheets for compound were copied and issued to the
Compound Operations Supervisor. Three copies of each Material Safety Data
Sheet for the Vinyl Department were issued to the Vinyl Operations
Supervisor.; _
' -. -
nny k, R.N. Plant urse
rah
cc: JF, JWW, DWH, PJK, LPS, WFH, CRS, RAF, AHS, JVU
Tom Crumbles - Houston
.h
J. R. Drumwright, M.D., - Houston
VAB.0001040194
ABERDEEN CHEMICAL PLAHT CHEMICAL DOSIMETRY TRENDS
Total Particulates
VAB. OOO1040195
A
I
ABERDEEN CHEMICAL PLANT INDUSTRIAL HYGIENE MONTHLY REPORT
'ililili'
Routine Chemical Dosimetry All Sample Results:
Chemical VCM Lead Total Particulates
Month: August
1
Date of Report: 10/4/84
*
%
JL PEL No. %
85 91.4 24 96.0
6 100.0
> PEL OVEREXPOSURES No. %
8 8.6 1 4.0 0 0.0
Overexposures Job Class Chief Operator Reactor Operator
Reactor Operator Reactor Operator
-
Exposure 1.2* ppm, VCM 10.1** ppm, VCM
1.4* ppm, VCM 2.9** ppm, VCM
Source
--
Employee overexposed while changing VCM filter pack filters.
Employee overexposed while doing his regular job of reactor operator in the old unit. No specific cause for his overexposure has been determi n ed.
Employee overexposed while sampling 745 reactor.
Employee overexposed while training a fellow employee and a reactor operator in the old unit. No specific cause for the overexposure has been identified.
*
4 VAB.0001040196
ayiL
A
ABERDEEN CHEMICAL PLANT INDUSTRIAL HYGIENE MONTHLY REPORT
Month: August Date of Report: 10/4/84
Routine Chemical Dosimetry AH Sample Results:
Chemical VCM Lead Total Particulates
jL PEL No. %
93 91.4 24 96.0
6 100.0
7* PEL OVEREXPOSURES No. %
8 8.6 1 4.0 0 0.0
Overexposures Job Class Chief Operator
i*
Reactor Operator
*-
Reactor Operator
Reactor Operator
Exposure 1.2* ppm, VCM 10.1** ppm, VCM
1.4* ppm, VCM 2.9** ppm, VCM
Source
Employee overexposed while changing VCM filter pack filters.
Employee overexposed while doing his regular job of reactor operator in the old unit. No specific cause for his overexposure has been deter mined.
Employee overexposed while sampling 745 reactor.
Employee overexposed while training a fellow employee and a reactor operator in the old unit. No specific cause for the overexposure has been identified.
VAB.0001040197
Industrial Hygiene Report - August Page 2
Overexposures
Exposure
Source
Dryer Utility
1.1** ppm, VCM
Employee overexposed while being trained as a reactor operator in the old unit. No specific cause for the overexposure has been identified.
Yard Operator
2.6* ppm, VCM
The employee was overexposed while hooking/unhooking VCM railcars at the VCM tank farm.
Mechanic
1.9** ppm, VCM
Employee overexposed while blanking out D-300 reactor condenser prior to condenser drilling.
Mechanic
6.2* ppm, VCM
Employee overexposed while changing out two Corken compressors at the VCM tank farm.
Line Compounder
44.4* microgram Lead/m^
The product being produced during sampling time contained no lead.
The source of the overexposure is not clear; it may be related to housekeeping in the area.
Respiratory protection was worn. ** Repsiratory protection was not worn.
VCM Area Monitoring
Four, forty-minute VCM area samples were taken at the top of 502 blend tank during the transfer of 5385 resin slurry from D-700 reactors using REAL "Minimonitor" badges. Wind direction was from west to east, ranging between zero and five miles
per hour. The results indicate, as have previous studies, that VCM concentrations atop blend tanks may reach levels that require the use of respirators during slurry transfer, depending on a variety of variables including wind conditions. Because of this, respirators should continue to be used during work atop the tanks.
No. Location
Result (ppm, VCM)
1 Top and SW of 502 on Safety Railing 2 Top and NW of 502 on Safety Railing 3 Top and SE of 502 on Safety Railing 4 Top and NE of 502 on Safety Railing
0.1 < 0.1 < 0.1
3.3
VAB.0001040198
Industrial Hygiene Report - August Page 3
1
Plasticizer-in-Air Monitoring
The results of plasticizer-in-air samples taken at the mills on Compound Lines I and III during July appear below. Sampling equipment consisted of Bendix BDX 44 air pumps equipped with Gelman 37MM cellulose filters. Sample analysis involved solvent extraction, followed by liquid chromatography. The single high result occurred during a period in which the "belt" of compound near the sampler was "smoking" excessively (for no obvious reason). A similar sample (#3), taken two hours later and at the same location, showed a hundred-fold decrease.
Compound No. Li ne
Date (Time) Compound
Plast. Location
Result (mg/m3)
1
3 7/23/04 38601 Blk
610P
SW Corner, E Take Off Belt
22.7
> (1118)
3
3 7/23/84 38601 Blk
610P
SW Corner, E Take Off Belt
0.2
(1318)
4
3
7/25/84 3934-152-Blk
610P
SE Corner, W Take Off Belt
0.2
(1012)
5
3
7/25/84 3934-152-Blk
610P
SW Corner, E Take Off Belt
0.2
(1012)
2
1 7/23/84 34642 Nat
108P
Oper. Station at Mill "Face" 0.2
(1314)
*
6
1 7/25/84 34642 Nat
108P
Oper. Station at Mill "Face" 0.2
(1055)
Equipment Calibration
The third quarter calibration of the precision rotameter used to measure Bendix BDX 44 air pump flowrates was completed using a large "bubble tube" as a primary standard. No significant drift was seen.
Ginny^fJffik, R.N. Plant Nurse
rah
cc: JF, JWW, DWH, PJK, LPS, CRS, RAF, AHS, JVU Tom Grumbles, J. R. Drumwright, M.D. - Houston
VAB.0001040199
i
%
i
/
%C
PEL
I
ABERDEEN CHEMICAL PLANT
I I ! II' ~ - 1 -Ttf T --
---------- ----------------------- "--------------- ~ '
-------- ----
CHEMICAL DOSIMETRY TRENDS
hf
1
r'
' -I
Total Particulates
* +
-
*
T
r xi ro a>
_ OJ
.
t2 ^ C
M a^ > o
a. 4| 13 d 5
*;> *
19
32
k
i9 83
.
Jan.
Feb.
M ar. A pr. May ' June Ju ly Aug. S ept.
O ct. Nov. Dec. Jan. Feb. M ar.
A pr. M ay
June
Ju ly Aug.
S ept. O ct. Nov;
. Dec.
h
i
` 19 84
:
JW :
VAB. OOO1040200
*
r
ABERDEEN CHEMICAL PLANT
INDUSTRIAL HYGIENE MONTHLY REPORT
Month: July
Date of Report: Aug, 14, 1984
Routine Chemical Dosimetry
All Sample Results:
PEL y PEL Overexposures
No. % No.
%
Chemical
VCM Lead Total Particulates
90 97 25 100
4 100
3 0 0
3 0 0
Overexposures
Job Class
Exposure
Source
Lead Operator
1.3** ppm,VCM
1. The employee states that he spent his entire shift inside the vinyl control room. No reason for his overexposure has been identified.
Yard Operator
1.7* ppm, VCM
2. Employee overexposed while hooking/unhooking VCM railcars and Corken compressor for maintenance at the VCM tank farm.
Mechanic
50.3* ppm, VCM
3. Employee overexposed while changing out a valve in a VCM line in the old unit.
* Respiratory protection was worn.
** Respiratory protection was not worn.
J
VAB.0001040201
A
VCM Area Monitoring
One sample was taken at each of the ten large reactor condensers. using REAL minimontor badges. The elevated results in the new unit (741 -745) were
traced to leaks repaired on the same day of sampling.
Date
# Reactor
7/25/84 7/25/84 7/25/84 7/25/84 7/25/84 7/26/84 7/26/84 7/26/84 7/26/84 7/26/84
741 742 743 744 745 D300 D400 D500 D600 D700
Plasticizer-in-air Monitoring
Resin
5425 5425 5425 5425 5265 5385 5385 5385 5835 5385
Sample Time
8 Hrs., 17 Min. 8 Hrs., 17 Min. 8 Hrs., 17 Min. 8 Hrs. , 17 Min. 8 Hrs., 17 Min. 7 Hrs., 50 Min. 7 Hrs., 50 Min. 7 Hrs., 50 Min. 7 Hrs., 50 Min. 7 Hrs., 50 Min.
Result ppm, VCM
1.1 0.8 1.5 0.9 0.3 <0.1 <0.1 0.3 < 0.1 0.4
Six plasticizer-in-air samples were taken at the mills on Compound Lines I and III, using Bendix BDX44 air pumps and Gelman cellulose filters. The results will be reported following lab analysis of the samples.
Lead Dosimetry Analysis
The plant began using the services of CTEK, Inc., a Dallas, Texas based laboratory, for analysis of routine lead dosimetry samples. The benefits gained are reduced cost and reduced analysis turn-around time.
Noise Control Report and Plan
The annual Noise Contol Report and Plan was issued.
OSHA "Hazard Communication" Rule
Tentative plans were laid for achieving compliance with the OSHA "Hazard Communication" rule. The first step/ establishing a list of plant chemicals by manufacturer and tradename, is planned to commence during August.
Material Safety Data Sheets
A copy of nine Material Safety Data Sheets were issued to the Maintenance Department. Material Safety Data Sheets for Plasticizer and Dry Blend were copied and issued to the Compound Operations Supervisor.
Plant Nurse
rah
cc: JF, JWW, DWH, PJK, LPS, WFH, CRS, RAF, AHS, JVU
Tom Grumbles - Houston
J. R. Drumwright, M.D. - Houston
VAB.0001040202
*
*
)
%<
PEL
VCM
ABERDEEN CHEMICAL PLANT CHEMICAL DOSIMETRY TRENDS
A
~<-; xi
^
-`
p
'll ,,
.
n iz S3iz -- to c*_ -- > '.j c ^ * :- >* no q. *; ^ 'j
^j a* ^ j--
ua
t; co o jj cn
* ^^
cl
'**> ir n
->'
3
-
|1 Qa; i>
C> cj a- &
19
.82
19 _$3_
' ,9 84
i
a
VAB. OOO1040203
3"VU~
%
ABERDEEN CHEMICAL PLANT INDUSTRIAL HYGIENE MONTHLY REPORT
1. Routine Chemical Dosimetry All Sample Results:
Chemical VCM Lead Total Particulates
Month: June Date of Report: July 19, 1984
PEL No. %
PEL OVEREXPOSURES No. %
93 96 10 100
5 100
4 0 0
4 0 0
Overexposures
Job Class Chief Operator
Lead Operator Rx Operator Mechanic
Exposure 3.7*ppm, VCM
4.8*ppm, VCM 3.9*ppm, VCM 82.2*ppm, VCM
Respiratory protection was worn.
A
Respiratory protection was not worn.
Respiratory Protection
Source
Employee overexposed while blocking in a VCM transfer pump which had a blown seal.
Employee overexposed while pumping "pond" resin.
Employee overexposed while changing VCM filter pak filters.
Employee overexposed while removing the main VCM valve going to the recovery system in the new unit.
3M airhat battery charging was made more reliable when compound operations provided each airhat wall case with an internal 110V electrical outlet and battery charger.
Dosimetry Equipment
The lab evaluation of the passive monitor marketed by GMD Systems, Inc. was completed during June. Future use of the device will be reconciled following issue of the report on the evaluation July.
VAB.0001040204
4
Industrial Hygiene Report Page 2
Program Audits
Routine Dosimetry
The second quarter audit of dosimetry frequency versus plan was conducted. No deficiencies were found.
A
An audit of the plant respiratory protection program was conducted. Recommenda tions for improvement, based on the audit results, were made and discussed with each department that uses respirators.
Material Safety Data Sheets
MSDS were reviewed by the Compound Department. A copy of each MSDS that pertains to the Compound, Dry Blend, and Plasticizer Department will be issued to the Compound Operations Supervisor.
rah
cc: JF, CRM, DWH, PJK, LPS, WFH, CRS, RAF, RAM, AHS, JVU Tom Grumbles - Houston J. R. Drunwright, M.D. - Ponca City
VAB.0001040205
. * ABERDEEN CHEMICAL PLANT A
CHEMICAL DOSIMETRY TRENDS
%C
PEL
TOO
VCM
0 TOO
r
i
V
Lead
0
Tota.l Particulates
O
,h
(
0
n
*-
>4
- --
w
+
CO Q,
>o
O? <-> o o
< CO O 2 O
t-------
f ----
*%
*4
'A*
CO O>s
rT3
j>"
*V)
CL w
O) O
o rr
ij o> O
id iTJ CL
>* 00 CL
^U
O ^ Q3 ^3 a> U O . U <C CO
19
VAB.0001040206
J MU
A
ABERDEEN CHEMICAL PLANT INDUSTRIAL HYGIENE MONTHLY REPORT
Routine Chemical Dosimetry A11 Sample Results:.
Month of: May Date of Report: June 19, 1984
PEL PEL Overexposures
Chemical VCM Lead Total Particulates Overexposures Job Class Chief Operator
Reactor Operator
Reactor Operator
Reactor Operator
81 88 11
39
97.5
1
4 100.
0
12
2.5 0
Exposure 16.0** ppm, VCM
1.8* ppm, VCM 6.0** ppm, VCM
3.7** ppm, VCM
Source
Employee overexposed while disconnecting and unplugging a lip seal line on D-300 reactor seal.
Employee overexposed while changing VCM filter pack filters.
Employee1 performed his regular job of reactor operator. No specific cause of his over exposure has been identified.
The employee did not perform his regular job of reactor operator. Instead, he was assigned to the tasks of painting handrails at the east incincerator and assisting electronics with small breaker labeling in the V-ll dryer area. No specific cause for his over exposure has been identified.
VAB.0001040207
Overexposures - Continued
Job Class Dryer Utility
Exposure 10.7* ppm, VCM
Yard Operator
2.5* ppm, VCM
General Mechanic General Mechanic General Mechanic Maintenance Supervisor
2.5* ppm, VCM
2.2* ppm, VCM
1.3**
VCM
1.5** ppm, VCM
Maintenance Superintendent
1.4** ppm, VCM *
r*.-
Color Weigh Compounder
118.9* microgram Lead/m3
* Respiratory protection was worn. ** Respiratory protection was not worn.
Source
Employee overexposed while monitoring blend tank levels in V-10 during pond resin reclaim.
Employee overexposed while assisting two general mechanics who replaced two Corken compressors at the VCM tank farm.
Employee overexposed while repairing a Corken compressor at the VCM tank farm.
Employee overexposed while blanking out 904 VCM recovery compressor.
Employee overexposed while changing a seal on D-300.
The employee spent approximately five minutes working near the new vinyl unit dump Sweco and approximately two minutes near the old vinyl PVC tank. The specific cause of his over exposure has not been identified.
m
Employee performed his regular job of maintenance superintendent, which took him to all parts of the pihnt throughout the work period. No specific cause for his overexposure has been identified.
Employee performed his regular job of color weighup, handling Halbase 100EP and Cyastab 988. No specific cause of his over exposure has been identified.
VAB.0001040208
mm mmrnmmmmmMmmmmmmm
A
VCM Area Samplin
A second set of four VCM area samples were taken in the bio-disc water treatment area, using: REAL "Minimonitors", Wind velocity ranged from 0 to 5 miles per hour, direction being from north to south. Sampling time was eight hours.
This set of sample results agrees with the one in April, both demonstrating the effectiveness of the recently installed ventilation exhaust blowers in reducing VCM levels. Similar measurements taken during 1983 showed results averaging 19,9 ppm and ranging from 0,6 to 87.9 ppm, VCM,
Sample Location
Result - ppm, VCM___________________ 1st Set CApril, 1984) 2nd Set (May, 1984)
Just north of middle bio-disc hut
0.2
0.1
West side of middle bio-disc hut
*
Just south of middle bio-disc hut
0.1 0.2
0.2 0.1
West side of east bio-disc hut
0.1
0.1
Area Ventilation Checks
The second quarter check of lab and compound ventilation hood velocities and flow rates was completed. The results were reported using a new format, which shows the results of the previous check.
Respiratory Protection
Plant Breathing Air System v-
*
Several repairs of the breathing air system were made, including replacement of sections of split pipe and faulty pressure regulators. The system is now operating correctly.
VCM Cannister Gas Masks
Removal of VCM cannister gas masks from plant service was completed.
Noise
The report on the plant noise survey conducted on April 10-11, 1984, by the Medical Department was received from them during May. The annual Noise Control v Report and Plan was written, using the results from the Medical Department survey, and submitted for review.
VAB.0001040209
GMD Systems, Inc. Passive Monitor
The second phase of the evaluation of the passive, VCM monitor marketed by GMD Systems, Inc. was completed. The results of the lab-based reproducibility studies will be reported by D. S. Cox, Manufacturing Chemist. Changeover from use of the REAL "Minimonitor" to that of the GMD device is anticipated, pending the reported results.
*
Equipment Calibration
The second quarter calibration of the precision rotameter used to measure Bendix BDX 44 air pump flowrates was completed using a large "bubble tube1' as a primary standard. No significant drift was seen.
Material Safety Data Sheets
MSDS were reviewed by the Vinyl Department and the Maintenance Department. Three copies of each MSDS that pertain to the Vinyl Department will be issued to the Vinyl Operations Supervisor. The Maintenance Department will be issued a copy of nine MSDS to update their book.
Ik, R.N. urse
rah
cc: JF, CRM, DWH, PJK, LPS, WFH, CRS, RAF, RAM, AHS, JVU Tom Grumbles - Houston J. R. Drumwright, M.D. - Ponca City
\
44
VAB.0001040210
4J
I
ABERDEEN CHEMICAL PLANT CHEMICAL DOSIMETRY TRENDS
1
A
Tota.l Parti culates
i
.
j <WI I H1
wmmmmmmmfKmmmmmmrnmmmmmimmmmmmmmmmmmm
f
h4
, . VAB.0001040211
1*
t
ABERDEEN CHEMICAL PLANT INDUSTRIAL HYGIENE MONTHLY REPORT
Month of Date of Report
April S/9/84
ROUTINE CHEMICAL DOSIMETRY All Sample Results:
Chemical
VCM Lead Total Particulates
< PEL
No. %
> PEL (OVEREXPOSURES)
No.
101 94.4 8 88.9 5 1100.0
6 1 0
5.6 11.1
0.0
OVEREXPOSURES Job Class General Mechanic
General Mechanic
Exposure 5.4*ppm, VCM
2.4* ppm, VCM
General Mechanic
2.2* ppm, VCM
Instrument Technician
9.3** ppm, VCM
Rx Operator
1.4* ppm, VCM
Rx Operator
145.6* ppm, VCM
Line Compounder
39.8* micrograms Lead/m^
Respiratory protection was worn. Respiratory protection was not worn.
Source
Employee overexposed while changing safety discs on D-400 reactor.
Employee overexposed while changing a sightglass at the horizontal VCM storage tanks in the VCM tank farm.
Employee overexposed while cleaning a sightglass at the horizontal VCM storage tanks in the VCM tank farm.
Employee overexposed while repairing the batch water stripper tubing.
Employee overexposed while checking VCM leaks in the old unit.
Employee overexposed while changing VCM filter pack filters.
Employee overexposed while charging Halbase 100EP on compound line III.
VAB.0001040212
It
Industrial Hygiene Monthly Report Page 2
VCM AREA SAMPLING
Four VCM area samples were taken in the biodisc water treatment area, using REAL
minimom tors Wind velocity ranged from 0 to 5 miles per hour, direction being
from west to tj * s
Sampling time was seven hours and fifteen minutes.
9-1 ir S
The samples were taken to measure the effectiveness of recently installed venti
lation exhaust blowers in reducing area VCM levels. Similar measurements taken
during 1983 showed results averaging 19.9 ppm and ranging from 0.6 to 87.9 ppm,
VCM. The evident reduction in VCM levels will be checked again during May.
Sample Location
Just north of middle biodisc hut West side of middle biodisc hut Just south of middle biodisc hut West side of east biodisc hut
PLANT NOISE SURVEY
Result ppm, VCM
0.2 0.1 0.2 0.1
/
0' 0i
o] f\ t
c> !
Pat McCoombs and Bill Richards of the Medical Department conducted an extensive plant noise survey on April 10-11, 1984. The work included property line noise measurements, noise level "contouring" within the plant, and noise dosimetry. Their report is expected to be issued during May.
RESPIRATORY PROTECTION
Scott Sling Paks
The relatively short waist straps provided with the five, recently received Scott sling paks were replaced with longer ones made from materials provided by Scott Aviation.
Training of vinyl shift supervisors on bottle changeout procedures for the sling paks was completed.
VCM Cannister Gas Masks
All VCM cannister gas masks were removed from plant service except those located in the Vinyl Departments area.
A
inny tfjpik, R.N. Plant/mirs e
rah
cc: JF, CRM, PEM, PJK, LPS, WFH, CRS, RAF, RAM, AHS, JVU Tom Grumbles - Houston J. R. Drumwright, M.D. - Ponca City
VAB.0001040213
ABERDEEN CHEMICAL PLANT
A
"
CHEMICAL DOSIMETRY TRENDS
c
c
*Y
MM wmmtmm
mm
VAB. OOO1040214
*
ABERDEEN CHEMICAL PLANT ROUTINE CHEMICAL DOSIMETRY SUMMARY
Month of:
Date Of Report:
cc: JF, CRM, PEM, PJK, LPS, WFH, CRS, RAF,, RAM, AHS Tom Grumbles - Houston J. ft. Drumwright, M.D. - Ponca City
March, 1984 April 12, 1984
ALL SAMPLE RESULTS:
Chemical VCM Lead Total Particulates
4
< PEL
No. i
79 91.9 21 95.5 24 100.0
> PEL (OVEREXPOSURES) No. %
7 8.1
1 4.5
0 0.0
OVEREXPOSURES Job Class Chief Operator
Reactor Operator
Reactor Operator
General Mechanic
Exposure 454* ppm. VCM
3.7** ppm. VCM
3.8** ppm, VCM
n
1.3** ppm. VCM
Source
Employee overexposed while helping control an emergency
VCM release at the VCM tank
farm.
Employee performed routine duties of reactor operator in the new vinyl unit. No specific cause has been identified.
Employee performed routine work of reactor operator. No specific cause has been found.
Employee overexposed while
cfcngiif out a Corken con-
VAB.0001040215
*
Routine Chemical Dosimetry Summary Page 2
OVEREXPOSURES - Continued
Job Class
Exposure
Source
General Mechanic General Mechanic
1.5** ppm, VCM 1.7** ppm, VCM
Employee overexposed while tightening a leaking con denser lid on D-600 reactor.
Employee overexposed while repairing the dryer line #2 centrifuge while pond resin was being reclaimed on dryer Line I.
General Mechanic
14.8** ppm, VCM
Employee overexposed while changing 742 reactor slow vent line.
Line Compounder
87.6* micrograms Lead/m^
Employee overexposed while charging blenders on Com pound Line I.
* Respiratory protection was worn. ** Respiratory protection was not worn.
VCM Area Sampling
Three VCM area samples were taken on the Toof of the V-ll dryer building during roof repair on 3/16/84. The samples were taken using REAL mimimonitors. Kind velocity ranged from 0 to 5 miles per hour, direction being from northwest to southeast:
Sample Location
Sample Time
(Hrs.-Min.)
Result ppip, VCM
Comments
On safety railing east of 655 blend tank
7-10
0.4 Coarse 5385 resin in 655
On Safety railing east
*
of and between 653 and
651 blend tanks
7-8
2.1 5305 resin in 651 and 653
On safety railing north of 650 blend tank
7-6
0.7 5305 resin in 650
Area Ventilation Checks
The second quarter check of lab and compound ventilation hood velocities and flowrates was completed. No serious deficiencies were discovered.
VAB.0001040216
Routine Chemical Dosimetry Summary Page 3
Noise Final arrangements for a plant noise survey to be conducted by the Medical Department on April 10-12, 1984 were made.
h
Total Particulates Analysis A five-place analytical balance, suitable for performing total particulates analyses, was purchased and received by the laboratory. Plans are to do all such analysis at Aberdeen beginning in April, 1984. Equipment Calibration The second quarter calibration of the precision rotameter used to measure Bendix BDX 44 air pump flowrates was completed using a large ,fbubble tube" as a primary standard. No significant drift was seen. Program Plans Both the Respirator Program and the Work Environment Hazard Control Plan were updated and approved.
rah
VAB.0001040217
p. f'
ABERDEEN CHEMICAL PLANT'
CHEMICAL DOSIMETRY TRENDS
t
Tota.1
Particulates F
r*
i
>
r
f
II-
!
iniMmm
mmm
*t i
j
* *
t * i
i
i
I I,
b k
P
+
i
1
1
m mmmmmmmmmm
VAB. OOO1040218
t t r
ABERDEEN CHEMICAL PLANT
INDUSTRIAL HYGIENE
----------------------------------------------------------------------------------------------------------
MONTHLY REPORT
--
--
-_
-
-----
Month of: February Date of Report: April 3, 1984
1. ROUTINE CHEMICAL DOSIMETRY
All Sample Results:
Chemical
VCM Lead Total Particulates
Overexposures
< PEL No. %
25 96.2 32 97.0 12 100.0
> PEL (OVEREXPOSURE] No. %
1 3.8 1 3.0 0 0.0
Job Class Line Compounder
Exposure
61.1* Micrograms Lead/nH
Chief Operator
29.1* ppm, VCM
*Respiratory protection worn 2. NOISE CONTROL
Source
Employee overexposed while charging Line III blenders No specific cause has been identified.
Employee overexposed while helping change VCM filter pack filters.
Resin deboxing area noise was reduced during February by insulating the cone at the bottom of the Sweco screener feed hopper. Noise level measurements taken before and after the insulation, using a General Radio Model 1565-B sound level meter, were :
Location
1. 2 ft. from cone,
on mezzanine
2. 16 ft. from cone, at ground level
Noise
Before Insulation
------------------------------------ -
-----------------------------
-
-
Level,
dBA After
Insulation
110 98-103
95 92
3. Main traffic isle. at south door*
*
93
-
*84 dBA with hopper vibrator "off".
89
VAB.0001040219
Industrial Hygiene Report Page 2
3. GMD SYSTEMS, INC. PASSIVE MONITOR
The lab-based familiarization study of the passive, VCM monitor marketed by GMD Systems, Inc. was completed. The second phase of the evaluation, involving reproducibility studies, was begun.
A
R.N. y urse
r/
cc: JF, CRM, PEM, PJK, LPS, WFH, CRS, RAF, RAM, AHS Tom Grumbles - Houston J. R. Drumwright, M.D. - Ponca City
VAB.0001040220
V
*
( c
ABERDEEN CHEMICAL PLANT CHEMICAL DOSIMETRY TRENDS
100
Total *
Particulates
-- - - -*
t -* v
)
r
(0
ini
J
+
*i
f #+ * r f
m*m
m
VAB.0001040221
*
mm*
mmm
ABERDEEN CHEMICAL PLANT ROUTINE CHEMICAL DOSIMETRY SUMMARY
Month of: January, 1984
Date Of Report: February 16, 1984
cc: JF, CRM, PEM, PJK, LPS, WFH, CRS, RAF, RAM, AHS Tom Grumbles - Houston J. R. Drumwright, M.D. - Ponca City
ALL SAMPLE RESULTS:
Chemical VCM Lead Total Particulates
No. 86
4 4
PEL
t~
> PEL (OVEREXPOSURES)
w.--
--------------------------------------
89.6 80.0 100.0
10 1 0
10.4 20.0
0.0
OVEREXPOSURES Job Class Color Weigh Compounder
Reactor Operator
Reactor Operator
Vinyl Lead Operator
Exposure
Source
95.2*, Micrograms Lead/m3
Employee did routine job of color weighup, including Hal base 100EP and Cyastab 988.
1.2* ppm, VCM
Employee overexposed while changing VCM filter pack filters in the old unit.
1.4* ppm, VCM
Employee overexposed while conducting a VCM leak check in the old unit.
1.5 ppm, VCM ?
Employee worked inside the vinyl control room during a period in which the control room air supply system was inoperative due to failure of a blower during cold weather.
VAB.0001040222
OVEREXPOSURES - Continued Job Class Vinyl Shift Supervisor General Mechanic General Mechanic
Electrician
General Mechanic General Mechanic
General Mechanic *Respi ratory^Yotecti on Worn
A
Exposure 2.4* ppm, VCM 1.6 ppm, VCM 1.6 ppm, VCM
2.0 ppm, VCM
2.4* ppm, VCM 3.3 ppm, VCM
21.3* ppm, VCM
Source
Employee overexposed while checking VCM filter packs in both vinyl units.
Employee overexposed while performing several VCM leak repairs.
Employee overexposed while insulating piping at grade level on the west side of D-400, D-500, and D-600 reactors. The specific source of VCM has not been identified.
Employee repaired a dry blend boxing hopper dust collector and a roll-up, traffic door just north of the Compound Shift Supervisor's office. The source of VCM has not been identified.
Employee overexposed while removing a blank from the end of a VCM line next to D-300 reactor to check for pluggage.
Employee repaired the steam tracing on an alcohol transfer line from the P-1 building to the plasticizer tank farm. No specific source of VCM has been identified.
Employee overexposed while repairing a VCM recovery compressor leak.