Document Xg4jqGkXJYwVjmoQNrvx5p2x

<i a.... I.io.'.'j/ii.'i o Cua/.SaiL Coij.sV.KY v/. c. timi; .r.r.iCti f i./.hv l ftc.or,aTory S'(WriDARD AA!-YTICA L Mr:vhod ' tIiwOKm1i'iNV2VV-j:i1jm'T7jrv-; 70 HLCni.ipbell ATT A CHMtiHT S I .1 :,F 10 A-lO'.ry ........"p.Vo viiti 'lv - - ^ [ HJJicrner *tnuc r Folycblorln.ated Biphenyls (PCB) irtr Determ!nation n Water, Sediment and A.'- Samples this rcm. I | sum. .uni s i u: i i.ou [_ J K2VISKI. l.'ISVr.UCTIOKS isnu^o 0:1 NEW SCOPE 'Phis method describes the preparation and subseo.uent gas chromatographic determination or trace amounts of polyc hi"-!listed biphenyls in ecological samples. For convenience it is virltten in three parts according to sai.io1 c type. . : ' EQUIPMENT j A. general a. Pas Chromatograph, Model 5750, with high temperature Ni*^ electron capture detectors (two) and required accessories. Hewlett Packard Co., Avondale, Penn. b. Syringe, 10 ul, Cat. No. 701, Hamilton Co., V.'hlttier, Calif. f* 0. Column (two). S'Ft x 6 mm glass, XE-60 on 80/100 mesh chromsorb-W, HP, AW-DMCS. precondition columns at 225C. for at least twenty-four hours with carrier gas flowing. Do not connect column to the detector during conditioning period'. d. Water bat!:, Thelco Model No. 8*1, Fisher Scientific Co., Sc louls, Mo. e. K".nderna-Danish Evaporative Concentrators, 500 ml capacity equipped with 3-ball Snyder columns and graduated 5 ml capacity receivers, Ca.t. No. 6707, Ace Glass Inc., Louisville, Ky. f. Llquiu ?hrenatographlc co.lu.ons, glass, 10 inch x 20 mm (on) ;ith 5 inch by 50 mr. (02) reservoir at the top and equipped with ' teflon stopcocks. Prepared by laboratory glassb'J.cv.er. g. Separatory funnels, 125.- p50, 500 and 1000 ini capacities equipped with ground glass stoppers and teflon stopcocks. :-.*r Scientific C; . h. Volumetric flasks, 25, 50, 100 arid 250 ml capacities. Fisher Scientific Co. . 1. Usual laboratory glassware and cqi'lpr.'r-vt. HONS 074682 Product: PCB Test: Determination in water, sediment and all- samples Method No. A-.1.005 Page 2 of 10 pages REAGENTS A. General a. Hexane, Pesticide grade. Cat. ho. H-300, Fisher Scientific , Co, b. Alcoholic Potassium Hydroxide, 2.5# (W/v), Dissolve 12.5 gramB of reagent grade KOII in 500 ml of Formula 2-B ethanol. c. Sulfuric Acid-water solution, 9/l (v/v). Carefully add 270 ml of reagent grade HaSO* acid to JO ml of distilled water in a 500 ml iced beaker, d. Sodium Sulfate, reagent' grade. Anhydrous granular. Cat. No. S-421, Fisher Scientific Co. e. Alumina, .chromatographic grade, 80/200 mesh de-activated. Fisher Scientific Co. Cat. No. A-540. Heat 190 grams at 4oo"C for a minimum period of *1 hours. Deactivate by adding 10 grama (5&(w/w)) of distilled water, shake well until lumps can no longer be observed. Let stand for two hours before using. f. Distilled water. Hexane washed. Extract 500 mis of . distilled water with several 50 ml portions of pesticide grade hexane to remove electron capturing impurities. g. PCB Standard Stock Solutions (Aroclor 1242, 1248, 1254 and 1260). Dissolve a known weight (20 to 25 mgs) of the appropriate Aroclor in 100 ml of Hexane In a volumetric flask. Mix thoroughly and store in a refrigerator. h. PCB Standard Solutions. . These solutions are prepared as needed. Dilute 0.5 ml of the PCB stock solution to 100 ml with hexane in a volumetric flask. The solutions should contain 1.0 to 1.25 nanograms (lO^gram) per microliter (ul) of the appropriate Aroclor. SAFlTPy Be' aware of the toxicity and corrosiveness of the reagents being used. Hexane is a highly flammable solvent. Keep away from hea1', "parks and open flame. Perform all solvent evaporations In a well vented hood. " "" HONS 074683 Product: POD Test: Determination in water, sediment and air samples Method Mo. A-1003 Page 5 of 10 pages instrumentation Temperatures: ~ /6S* Column oven: v.'S'ClC Detector: 275C Injection Port: ?00C Flow Hates: Helium carrier: *v60 ml/mln. . Argon-methane: purgeoO.20 mi/mln. Electrometer & Recorder: Pulse interval: 150 Range: 10 Attenuation: 16 . Recorder: 1 mv @0.25 or 0.5 inch/min. Note: Elution times for highly chlorinated PCD (Aroclors l?5*l & 1260) can be decreased by raising column oven tomperature^20C. The instrumentation described in this method utilizes an electron capture detection system which contains the radioisotope nickel 63. As a consequence its operation is subject to all rules, regulations and orders of the Atomic Energy Commission (AEC). Among the more important of these are the following: a. Operation of the instrument is restricted to trained personnel under the guidance of the licensee (H. L. Campbell and/or H J. Horner). b. Effluent grt met be piped to n fume hood, and leak tests performed by licensee at six month intervals. o. Repair, modification or removal of detectors is prohibited except by authorized personnel. Since abusa or failure to comply with all regulations can result in the loss of license; it is recommended that in case of instrument malfunction the licensee be notified and the instrument shut down Immediately. ' DETERMINATIONS Part A - Water Samples NONS 0 74684 Procedure 1. Transfer the entire aqueous sample or a 250 ml aliquot of very large samples into a graduated glass cylinder. Record IYoduct: FOB Teat: Determination In.,water, sediment and air samples Method Mo. A-1009 Page Jl of 10 pages the volume of the sample and quantitatively transfer it. to a separatory funnel with distilled water. 2. Rinse the graduated cylinder with two 50 ml portions of hexane and add each to the separatory funnel. 3. Stopper the separatory funnel and shake vigorously for at least 1 minute. Allow layers to separate and transfer the lower aqueous phase to a second separatory funnel. *1. Extract the water sample a second time with a 50 m.1 portion of hexane. After layer separation, add the initial hexane extract to the second funnel and transfer the water layer back to the original separatory funnel. 5. Repeat the extraction with a' third 50 ml portion of hexane. Discard the water layer and combine the hexane extract.3. 6. Milter the hexane extracts through a funnel plugged with glass wool covered with sodium sulfate. 7. Collect the filtrate in a Kunderna-Danish evaporative concentrator, add a boiling chip, put the Snyder column In place, and reduce the hexane volume to less than 5 ml by heating the apparatus in a 80-90C water bath (HOOD). 8. After cooling, remove the 5 ml graduated receiver and transfer the concentrate to a previously prepared alumina adsorption column, washing it in with ee"eral 5 ml portions of hexane. 9. Carefully add 100 ml of hexane to the column reservoir and collect the total eluent in a Kunderna-to.iish concentrator. Mote: If the sample is known to contain 1 ppm or more of PCB, concentration is r>.'t required it. hm m rw><nh. Instead collect the eluent in a 250 ml volumetric flask and dilute to volume with additional hexane. 10. If the column eluent has been collected in the evaporative concentrator, reduce solvent volume to less than 5 ml, cool, and dilute to s suitable volume in a volumetric flask with addli tcnal hexane. 11. Inject 1 to 10 ul of the hexane solution into the chromatograph operating at the prescribed conditions - see instrumentation. 32. Determine the type of PCB b" nomparinf-; w.e 'cmplo chromatogram to those of various Aroclor standards. 13. Once the FOB unknown has been identified, l..Ject 1, 2 and 3ul volumes of the appropriate Aroclor standard solutio.. Into the the chromatograph. MCNS 074685 Product: Polychlorinated Biphenyls (PCB) Test: Determination in water, sediment and air samples Method Mo. A.-100? Page 5 of lOpages l'l. From the sample chromatogram, select a pealc free from Interference and measure its height in millimeters (min). Record also the volume injected. 15. Locate the corresponding peak in the standard chromatograms and measure the peak heights at the various volumes Injected. Prepare a plot of peak height (in millimeters) vs. concentration (nanograms) from the volumes of standard solution injected. Note: t, In all cases, the response of the electron capture detector must be linear for quantitative analysis. With the Instrumentation and procedures described here, any response less than JO percent full scale at an attenuation of 16 x 10 falls within the linear response range at a pulse rate of 150,_q This corresponds to about 5 nanograms (5 x 10-yg) of PCB. Samples with greater response must be re-analyzed from a more dilute solution and/or "wTth a smaller injection volume. CALCULATION a. Determine the nanograms (ng) of PCB in the unknown by referring peak height to the standard curve. Divide this quantity by the volume injected to obtain nanograrns per microliter (ng/ul). b. To obtain total micrograms (ug) of PCB in the Chromatographic solution: PCB in ug - nanograms/micrOliter X volume of sample sol'n(r:ls) Note: . 1. The concentrations ng/ul and ug/ml are equivalent. -in'; of samp1'' rol-tior f.r ''htalned f":- ~ of the Procedure Section. ">0 c Amount of PCB in sample: i1. oPCrnB i1nr, ppm - SamPpCleB vinoluumge___o__r__n_e__ig__h Imls or gr )' 2. PCB in ppb rPn' of> PUB X 1000 Report results to nearest part per billion (ppb). Part B - Sediment o" Sell Samples K1UITHENT A. General HONS 074686 See Page 1. Product! Polychlorinated Biphenyls (PCB) 'Pest: Determination in water, sediment and air samples Method No. A-1005 Page 6 of 10 pages B. Specific a. Pyrex baking dishes, 0 x 12 x 2 inch (2 1/2 quart capacity), Fisher Scientific Co. b. Mortar and pestle, all glass, 32 oz. capacity, Fisher Scientific Co. o. Filter funnels, sintered glass, 600 ml capacity 90 mm IB, medium porosity, Fisher Scientific Co. d. Sieve, U. S. Standard No. 30, Fisher Scientific Co. e. Shaker, reciprocating, variable speed. Cat. No. l1t-260, Fisher Scientific Co. f. Fladcs, flat bottomed, Boiling, capacity 125 ml, Cat. No, 6896 (code-OA), Ace Glassware Co, g. Condenser, Liebig, 200 mm length, Cat. No. 5915 (code-12), Ace Glassware Co. REAGENTS A. General See page 2. B. Specific a. Acetonitrile, pesticide grade. Cat. He. A-999, Fisher Scientific Co. SAFETY Acetonitrile is a toxic and flammable solvent. Avoid inhalation or prolonged contact of the skin. Keep away from her.t, sparks tu,. --. Handle x.'. u 'i.-.,.l vented hu^.x. PROCEDURE 1. Decant any excess water and transfer the entire soil or sediment sample to a glass baking dish. Air dry at room fciaperflure. 2.' When dry, transfer the sample to a mortar ana pestle and grind. Sieve the ground material through a No. 30 mesh screen, 3. '.':iu'.- 5" u (to th~ .learest 1.1 g) of the s.\..ve<1 -...pie . into a 16 oz. narrow-ncck, screw cap (aluminum foil liner) glass bottle. . HONS 074687 Product: PCD Test: Determination In water sediment and air samples Method No, A-l009 PaGO 7 of 10 pages 4. MoiBten the sample with distilled water (ca 10 ml.) and add 150 ml of acetonitrile. Cap the bottle tightly, and mechanicstly shake for at least i hour, 5. Quantitatively transfer the acetonitrile extract Into a ; 600 ml sintered glass filter funnel containing a l/'tlnch layer of anhydrous sodium sulfate. Collect the filtrate in a 600 ml beaker. Note: Vacuum filtration may be necessary. In this case, collect the filtrate In a 500 ml suction flask. 6. After the acetonitrile has completely drained, wash the bottle twice with 50 ml portions of acetonitrile, adding each wash to the funnel after the previous has completely passed through the filter, 7. Quantitatively transfer the extract to a Kunderna-Danlsh evaporative concentrator, add a boiling chip, put the Snyder column In place and reduce the acetonitrile volume ; to about 5 ml by heating the apparatus In the water bath (HOOD). 8. After cooling, remove the 5 ml graduated receiver and transfer the concentrate to a 125 ml extraction flask, washing It with Beveral small portions of solvent. 9. Evaporate the extract Just to dryness with a gentle stream of dry nitrogen, and add 25 ml of 2.5# alcoholic KOH, 10. Add a boiling chip, attach the flask to a water cooled condenser and allow the solution to reflux for JI5 minutes. 11. After cooling, transfer the solution to a 250 ml separatory funnel with the aid of 25 ml 'ZrA.Smt. rf, fidd //saquE. or dtiostTilhlee. dSt/wWartAeTr.cry cl Viib7/:b FMifx. 12. Fxteao.i*, by shaking* . Con leas*' 0,-,* pi m'*--'- Allow the layers to separate and transfer the iower aqueous layer to a second 250 ml separatory funnel. 15. Extract the aqueous layer a second time with a 25 ml portion of fresh hexane. After layer separation, add the initial hexane extract to the second funnel and transfer tb aqu'r. s layer back to the original separatory funnel, l1!.' Repeat the extraction with a third 25 ml portion of hexane. Discard the aqueous layer and combine the hexane extracts. 15. , Carefully add 15 nO of ti.o 9*1 sulfuric acJd-water solution to the combined hexane in the separatory funnel. HONS 074688 Product: PCB Test: Determination In rater,, sediment and sir samples Method Ho. A-1009 Page 8 of 10pages 16. Extract bp shaking vigorously for at least 1 minute. Alio;: the layers to separate and discard the lower acid-water layer. Repeat this step until acid layer is colorless.' 17. Wash the hexane with 25 ml portion of distilled water and discard the water wash. 18. Kilter the hexane through a filter funnel plugged with glass wool covered with Bodium BUlfate. 19. Collect the filtrate in a Kunderna-Danish evaporative concentrator, add a boiling chip, put the Snyder column in place, and re-'uce the hexane volume to less than 5 ml by heating the apparatus in the water bath. 20. After cooling, remove the 5 ml receiver and transfer the concentrate to a previously prepared alumina adsorption column, washing it in with several 5 ml portions of hexene. 21. Proceed according to Part A. Procedure, beginning with Step No, 9. Part C - Air Scrubber Samples Equipment See Page 1. REAQEHTS A. General See Page 2 JU. ilpvujk. aC a. Toluene, pesticide grade. Cat. No. 8092, Mallinckrodt Chemical Works, St. Louis, Mo. SAFETY The scrubber solvent toluene is a toxic and flammable linuid. Avoid pi'olonged Inhalation and contact with the skin. Keep away from heat, spark and open flame. PROCEDUHE _ . The airborne PCB's have been absorbed in toluene by drawing a known quantity of air through gas a'rubbers filial with the solvent. SONS 074689 Product: PCB . 'Post: Determination in water, sediment and air samples Method No. A-1009 Pago 9 of 10 pages 1. Obtain and record the volume of air sampled. 2. Quantitatively filter the scrubber solvent through a sintered glass filter funnel containing a l/t inch layer of anhydrous sodium sulfate. Collect the filtrate in a round bottom flask. 3. Wash the scrubber with several Tresh volumes of toluene or hexane, adding each wash to the funnel after the previa: s has passed through the filter. 4. Reduce the, scrubbing solvent volume to about 2 ml by heating on' a steam bath and blowing with a gentle stream of dry nitrogen. 5. Dilute the concentrate with hexane to a suitable volume in a volumetric flask. 6. , Inject 1 to 10 ul of the solution into the chromatograph. If no Interferences are observed, proceed according to Part A, Procedure, beginning with Step No, 12. Note: If interferences are present proceed with the alumina column clean up procedure beginning with Step No. 8. CALCULATION ' . Report the results as micrograms (ug) of PCB per unit .volume of air sampled. ' DISCUSSION Almost all samples from an environmental source will require some type of clean-up procedure before anajysls by electron capture chromatography. Unless exoerience has shown otherwise, ail hexane solutions of the samples should be taken through the alumina column cleanup prior to Injection into the chromatograph. Interferences which remain after alumina column clean up can oftentimes be eliminated by chemical treatment-saponification with 2.5# alcoholic KOH. . Laboratory sources of co-itamfnat"'O ' can be a major probl 't, !.r> trace determinations by electron capture chromatography. The samples and extracts should never be allowed to come in contact with materials other than glass, teflon or metal. Laboratory glassware should be thoroughly washed with hot, soapy water, rinsed with distilled water, acetone, and then hexane. All equipment should also be rinsed again win. hexe"'* just pio.or to use and bra.-ms should be frequently carried through all stops of the procedure to insure against the possioility of PCB contamination.. HONS 074490 Product: PCB Tout: Determination in viator, sediment and air Bariiplea Method No. A-1009 Page 10 of 10 pages Column performance is the key to effective gas chromatographic analysis. Since all liquid substrates bleed to one degree or another and columns eventually degrade, continual observation of of the chromatograms for satisfactory oolumn performance is necessary. Signs of degradation are a loss in resolution and the tailing of peaks. When these conditions are observed, a new column should be prepared and put into use. REFERENCES a. Organic Research Analytical Method No. 69-13. i; i i i i i i MGNS 074691