Document XVwRy5xOd5Ja631yjMjeOxQR

Monsanto FtCM NAM{ & lOCATlONI SC Mark Riddle. LP&S, Texas City 0-22 Ext. 3236 fttfEteNct March 9, 1983 PMSB SHAC Minutes of Hourly Safety Committee Meeting February 22, 1983 TO Manuel Perez 51D Duffey O'Briant SS-9 Allen Tovrea 33D Pervis Cotton, Jr. LD W.% A. Lowrey J. W. Hughes Lee Derrick Albert Solis SS-10 SS-13 AB-1 2PD 12409 ALL MEMBERS WERE PRESENT! Manuel Perez, Chairman, introduced Bob Hammann as the guest speaker. Bob discussed the Loss Prevention and Safety Department's functions, personnel, and their respective responsibilities. Mark Riddle discussed the revision to P-0123, "Bypassing and Testing Protective Devices", and announced that the Dnit/Craft safety training at Danforth Campus would be March 10 and 11. He also announced that the STOP training program for Chiefs/Leadmen was proceeding on schedule and STOP cards would be brought to the next meeting for the HSC members to review. UNFINISHED BUSINESS Cooling Tower Fan Hazard In January the Carpenter representative to the committee stated that a safety hazard existed on all but one of the cooling towers. Even though the fan drive motors are locked-out prior to entering the fan area, the fans turn naturally because of the wind drafts created in the tower. Attempting to stop the heavy fan blades, which sometimes turn at a high speed, is hazardous. CT-8 has brakes on the shaft which can be applied. Although this doesn't give 100% protection, it does give considerably more protection than having nothing. Action: There was considerable discussion on this problem again. The committee was told that it was brought up in the PMSB meeting, and that Plant Engineering (Hammond/McClanahan) was actively pursuing this. Removing Bolts from 51D4 Manway Covers Prior to Decontamination A committee member reported that during the last AN shutdown all but four bolts were removed from each manway cover prior to blinding the column. Action: There was also much discussion on this topic and the committee was told that this was also considerably discussed at the PMSB meeting. The PMSB has asked SHAC to canvass the plant to see what the different practices/procedures are and then to go to SAC to determine a plantwide policy. LAM013603 Page 2 NEW BUSINESS A number of concerns were surfaced by various members of the committee. After discussing the individual concerns it was decided that most should be taken to the appropriate unit/craft safety committee for actions. There were two concerns, however, that can impact the entire plant. They are discussed below: 1. Extension Ladders An extension ladder was found put up backwards in Zone 1--much discussion about correct installation of ladders followed. Proposed Action: A memo will be written to supervision requesting emphasis in this area. 2. Barricade Tape A concern was voiced about barricade tape--tape is being left up after need no longer exists. Therefore, many times tape is ignored. Proposed Action: A memo will be written to supervision requesting emphasis in this area. Chairman's Comments The Chairman asked that a copy of these minutes be posted in the control rooms and given wider spread distribution so that people will know that their concerns are being brought to the HSC's attention, and also to aid in communication. Proposed Action: This request will be discussed further at the next meeting. Mauk Mark Riddle MAR/es 12410 SC LAM013604 Mark Riddle, LP&S, Texas City 0-22 Ext. 3236 March 1, 1983 Hawc. Hourly Safety Committee Meeting February 22, 1983 A. H. Conrad 0-6A R. T. Hammann 0-22 X USTED AM. ColX&UiS TAlKCD AJWT - MowEV6K | PlrJA-C 5HoyLD PfiOftAgPC MOT OWTAl/J ALL op TtttftA . ALL MEMBERS WERE PRESENT! Manual Perez, Chairman, introduced Bob Hammann as the guest speaker. Bob discussed the Loss Prevention and Safety Department's functions, personnel, and their respective responsibilities. Mark Riddle discussed the revision to P-0123, "Bypassing and Testing Protective Devices", and announced that the Unit/Craft safety training at Danforth Campus would be March 10 and 11. He also announced that the STOP training program for Chiefs/Leadmen was proceeding on schedule and STOP cards would be brought to the next meeting for the HSC members to review. UNFINISHED BUSINESS Cooling Tower Fan Hazard In January the Carpenter representative to the committee stated that a safety hazard existed on all but one of the cooling towers. Even though the fan drive motors are locked-out prior to entering the fan area, the fans turn naturally because of the wind drafts created in the tower. Attempting to stop the heavy fan blades, which sometimes turn at a high speed, is hazardous. CT-8 has brakes on the shaft which can be applied. Although this doesn't give 100% protection, it does give considerably more protection than having nothing. Action: There was considerable discussion on this problem again. The committee was told that it was brought up in the PMSB meeting, and that Plant Engineering (Hammond/McClanahan) was actively pursuing this. Removing Bolts from 51D4 Manway Covers Prior to Decontamination A committee member reported that during the last AN shutdown all but four bolts were removed from each manway cover prior to blinding the column. Action: There was also much discussion on this topic and the committee was told that this was also considerably discussed at the PMSB meeting. The PMSB has asked SHAC to canvass the plant to see what the different practices/procedures are and then to go to SAC to determine a plantwide policy. SC 12411 LAA/1013605 Page 2 NEW BUSINESS Hughes: 1. Voiced a concern with the scaffold racks presenting a "head knocker' hazard. Proposed Action: Bob Hammann to get with Bob Bohmler to take care of this problem. 2. Found an extension ladder put up backward in Zone 1--much discussion about correct installation of ladders. Proposed Action: Memo should be written to supervision requesting emphasis in these areas. 0'Briant: 1. Voiced a concern about barricade tape--tape is being left up after need no longer exists. Therefore, many times tape is ignored. Proposed Action: Memo should be written to supervision requesting emphasis in these areas. McKee (for Lowrey): 1. 600 psi steam hot stopple job, a l/i" bleed came off. Proposed Action: Bob Hammann to investigate. 2. a) Lighting out in Power House, top bulbs are out. b) Power 2 maintenance shop, upper deck without a toeboard, and "head knocker" hazards that need to be highlighted. Proposed Action: These items will be taken to the Power 2 supervision by Albert Solis, the Hourly Safety Committee member present. Perez, Chairman: 1. Asked that a copy of these minutes be posted in the control rooms and given wider spread distribution so that people will know that their concerns are being brought to the HSC's attention, and also to aid in communication. Proposed Action: Let's discuss. AW Mark Riddle MAR/es 124^2 SC LAM013606