70 CHAPTER 5 1962 Guide And Data Book Table 6.... Heating Capacities and Cfm of Branch Ducts in Extended-Plenum Perimeter Systems (Continued) Section C. Sid* Take-Off to 6-fcid band Pip* for Baseboard Oiffnm Ody Extended-Plenum Pressure O.IS in. Static of 160 F Furnace-Plenum Pressure 0.15 in. Static at 170 P No. of Show* | Aefwcrf Length from ExhaM-fftnn fo Diffmer--feet 5 10 15 20 25 30 35 40 45 50 55 60 0 Btuh 9800 9100 8430 7820 7230 6700 6200 5730 5320 4920 4550 4210 Cfm 106.6 104.4 102.3 100.3 98.5 96.8 95.0 93.1 91.7 90.0 88.6 87.2 1 Btuh' 9230 8550 7930 7360 6800. 6300 5830 5400 5000 4620 4280 3960 Cfm 100.4 98.7 97.0 95.3 93.7 92.0 90.4 88.9 87,6 86.2 84,9 83.8 2 Btuh 8740 8100 7500 6960 6420 5960 5510 5110 4730 4390 4050 3750 Cfm 95.5 93.8 92.2 90.6 89.4 88.0 86.5 85.2 84.0 82.8 81.6 80.6 3 Btab 8300 7690 7130 6600 6110 5680 5240 4850 4500 4170 3840 3560 Cfm 91.0 89.5 880 86.7 85.5 84.2 83.0 82.0 80.9 79.8 78.8 77.9 4 Btuh 7930 7350 6800 6290 5830 5400 5000 4620 4270 3940 3630 3370 . Cfm 88.8 85.5 84.2 83.3 82.0 81.0 80.0 79.1 78.0 77.0 76.1* 75.3 5 Btuh 7600 7020 6500 6020 5580 5160 4770 4410 4080 3770 3470 3190 Cfm 83.6 82.5 81.3 80.2 79.1 78.1 77.1 76.4 75.3 74.4 73.5 72.8 6 Btuh 7300 6760 6260 5780 5350 4950 4560 4200 3900 3580 3300 3040. Cfm 80.4 79.5 78.4 77.5 76.3 75.3 74.4 73.5 72.8- 72.0 71.2 70.6 Note: When ear ed the first thits root into tie sctended-plcanm rrrr.ed to ft end S elbows, ooust i extre elbows for tbtt ran. Tbe Eqarvslent Length Vsloes isad sod included in --l---I-*!-* this table ere: Diffaser end Boot -- 100 ft; Etch Elbow * 14 ft; Side Teke-cff Bft. Thpcred Extended-Flenum Starting Coilax. Section D. Top Take-Off to d-lndt Sound Pip* for Baseboard Diffuser* Oaty Extended-Plenum Pressure O.lt in. Static at 160 P Furnace-Plenum Pressure 0.15 in. Static at 170 F No. of Shew* Advaf length from Cxfended-Pfeouui fo Diffmer -Feel 5 10 15 20 25 30 35 40 45 50 55 60 . 0 Btuh 8700 8050 7450 6900 6400 5910 5470 5160 4670 4300 4000 3720 Cfm 95.0 93.2 91-7 90.0 88.6 87.3 86.0 84.7 83.5 82.4 81.3 80.2 1 Btuh 8280 7640 7090 6560 6080 5630 5200 4820 4470 4140 3830 3530 Cfm 90.2 .88.8 87.5 86.2 85.0 83.7 82.6 81.7 80.4 79.4 78.4 77.5 2 Btuh 7880 7290 6750 6250 5800 5380 4980 4590 4260 3940 3620 3340 Cfm 86.3 85.0 84.0 82.9 81.7 80.5 79.6 78.7 77.6 76.7 75.8 74.9 3 Btab 7560 7000 6470 5980 5540 5130 4740 4380 4060 3730 3430 3170 Cfm 83.0 82.0 81.0 79.8 79.0 78.0 76.9 76.0 75.1 74.2 73.3 72.5 4 Btuh 7260 6700 6200 6740 5290 4900 4510 4160 3850 3560 3290 3020 Cfm 80.0 79.1 78.1 77.2 76.2, 75.2 74.3 73.5 72.7 71.9 71.0 70.2 5 Btuh 7000 6470 5970 5490 070 4700 4320 3990 3600 3400 3120 2870 Cfm i 77.3 76.3 75.4 74.5 73.6 72.8 71.9 71.2 70.2 69.3 68.7 68.1 6 Btuh 6770 6230 5740 5290 4890 4500 4140 3820 3520 3240 2980 2760 Cfm 74.6 73.8 73.0 72.2 71.3 70.5 . 69.8 69.0 68-3 67.5 66.9 66.1 Note: Where any of tbe first three ran* from the extended-plenum exceeds 10 It and S elbow*, coast 1 extra elbow* for that ran. Tbe Equivalent length Velure uaod and included is --1--this table are: Difiusw and Boot 100 ft; Each Elbow 11 ft; Top Take-aS 80 ft. Tapered Ertendad-Plenora Starting Collar. taken from basements and crawl spaces, but should not be taken from confined spaces in which the furnace is located. The following simplified procedure* may be used: 2. Lay out the return-air duct system. Measure tbe length and count the number of 90 deg turns in each return duct. 2. Total tbe heat los of the area served by each return duct. 3. Determine the required duct free area from the length of duct, the number of 90 deg turns, and the heat loss using Table 8. Also determine the free area of the return grille from Table 8. Other Perimeter Systems Each of the foregoing procedures can be used with ap proved furnaces that are capable of delivering their rated cfm air volume against a total pressure of 0.20 in. water Warm Air Heating Systems 71 Table 6.... Heating Capacities and Cfm of Branch Ducts In Extended-Plenum Perimeter Systems (Concluded) Section E. Side Take-Off to Sbd) Bowed Pip* for Side-wcD and Boor Diffwxer* gstended-Plenum Pressure 0.16 in. Static at 160 F Furnace-Plenum Pressure 0J5 in. Sialic at 170 F Actual length from fjdeoM-Nonve fo Diffuse*--Feet 5 10 15 20 25 30 35 40- 45 50 55 50 0 Btab Cfm 8600 123.2 7930 120.0 7310 116.8 6740 114.0 6230 111.4 1 Btuh Cfm 8560 117.4 7900 114.5 7290 112.1 6720 109.2 6200 107.0 5740 104.8 2 Btuh Cfm 8510 112.7 7890 110.0 7300 107.6 6740 105.3 6230 103.1 5750 101.0 5310 99.0 3 Btuh Cfm 8540 7900 7300 6780 108.2 105.8 103.6 101.5 6270 99.6 5800 97.8 5360 95.9 4960 94.0 4 Btuh Cfm 8580 104.0 7970 101.9 7370 99.8 6820 97.8 6330 96.0 5850 94.5 5410 92.8 5000 91.1 4620 89.7 5 Btuh Cfm 8720 100.2 8080 98.3 7490 96.7 6940 94.8 6440 93.0 5960 91.4 5490 90.0 5080 88.7 4690 87.2 4320 85.0 6 Btuh 8900 8240 7630 7060 6550 6070 5600 5190 4800 4430 4100 Cfm 97.0 95.1 93.4 91.9 90.2 88.8 87.3 86.2 85.0 83.8 82.6 Note: Where eoy of the firet three mo* from the octended-pleaom exceed* >0 ft end 3 elbow*, count 8 extn elbow* for that run. The Equivalent Length Value* and and included in calculating thij table are; Diffaser aad Boat m 40 ft; Each Elbow -- 14ft; Side Takn-oS 30 ft. Tapered Extended-Pleaam Starting Collar. 5800 109.1 5340 102.8 4960 97.4 4610 92.5 4300 88.3 4020 84.7 3810 81.5 Section F. Top Toke-Off to 6-tncb Rowad Pipe for SMe-wofl and Floor Biffwort Extended-Plenum Pressure O.lt in. Static at 160 F Furnace-Plenum Pressure 0.15 in. Static at 170 F Ho. of Show* Actual length from fxhaM-FJetM fo Difftnor--feet 5 10 15 20 25 30 35 40 45 50 55 40 0 Btuh Cfm 8430 111.2 7800 1088 7210 106.3 6660 104.4 6170 102.2 5700 100.2 5270 98.4 1' Btuh Cfm 8450 107.2 7840 105.0 7250 102.8 6700 100.7 6210 98.9 5730 97.0 5300 95.1 4900 93.4 2 . Btuh Cfm 8530 103.2 7900 101.1 7320 99.0 6800 97.2 6280 95.4 5790 93.8 5350 92.1 4960 90.6 4590 89.0 3 Btuh Cfm 8660 99.7 8020 97.8 7430 96.0 6900 94.2 6370 92.4 5900 90.8 6450 89.4 5030 88.0 4650 86.7 4300 85.3 4 Btuh 8810 8180 7580 7010 6500 6000 5550 5150 4750. 4400 4070 Cfm 96.0 94.4 92.8 91.2 89.7 88.0 86.8 85.7 84.3 83 1 82.0 5 Btuh 8390 7770 7200 6650 6160 5700 5280 4890 4500 . 4170 3840 Cfm 91-4 90.0 88.5 87.2 85.8 84.5 83.2 82.4 81.0 80.0 79.0 6 Btuh 7980 7380 6840 6340 5880 5430 6020 4650 4290 3970 3660 Cfm 87.5 86.2 85.0 83.8 82.5 81.4 80.2 79.4 78-3 77.3 76.3 Note: Where any of tbe firn three ran* from the extended-plenum exceed* 30 H aad 3 elbow* count 8 extra elbow* for that rua. The Equivalent Length Value* need aad Included in eaieulating thi* table are: DifftMx aad Boot 40 ft; Each Elbow 14 ft; Top Take-off -> SO (tTapered Riteaded-Renum Starting Collar. 4910 96.7 4560 91.9 4250 87.8 3990 84.2 3780' 81.1 3580 78.3 3400 75.6 eternal to the furnace. This available pressure is usually dis tributed on the basis of three-fourths (0.15 in. water) on tbe supply side and one-fourth (0.05 in. water) on the return side. Other systems, such as perimeter crawl-space plenum systems, may be designed by procedures outlined in Manual .4- In addition, procedures for designing 4-in. dtnmptftr duet systems are contained* in Manual 10 of the National Warm Air Heating and Air Conditioning Association. Other systems of a proprietary nature but utilising the perimeter concept of diffuser placement are in common use. These systems should be designed and installed in^strict accordance with tbe manufacturer's recommendations. Such systems usually utilize smaller ducts (4 in. or less) and higher pressures (above 0.20 in. water). They also may re quire special streamlined, low resistance fittings and special diffusers. Some systems also employ higher boiwet tempera-