Document XRygwJrrkwodr2aRznQ2gX1XJ
70
CHAPTER 5
1962 Guide And Data Book
Table 6.... Heating Capacities and Cfm of Branch Ducts in Extended-Plenum Perimeter Systems (Continued)
Section C. Sid* Take-Off to 6-fcid band Pip* for Baseboard Oiffnm Ody
Extended-Plenum Pressure O.IS in. Static of 160 F
Furnace-Plenum Pressure 0.15 in. Static at 170 P
No. of Show*
| Aefwcrf Length from ExhaM-fftnn fo Diffmer--feet 5 10 15 20 25 30 35 40 45 50 55 60
0
Btuh
9800 9100 8430 7820 7230 6700 6200 5730
5320 4920 4550 4210
Cfm
106.6 104.4 102.3 100.3 98.5 96.8 95.0 93.1
91.7 90.0 88.6 87.2
1
Btuh'
9230 8550
7930
7360
6800. 6300
5830
5400
5000
4620
4280
3960
Cfm
100.4 98.7 97.0 95.3 93.7 92.0 90.4 88.9 87,6 86.2 84,9 83.8
2
Btuh
8740 8100 7500 6960 6420 5960 5510 5110 4730 4390 4050 3750
Cfm
95.5
93.8
92.2
90.6
89.4
88.0
86.5
85.2
84.0
82.8
81.6
80.6
3
Btab
8300 7690 7130 6600 6110 5680 5240 4850 4500 4170 3840 3560
Cfm
91.0
89.5
880
86.7
85.5
84.2
83.0
82.0
80.9
79.8
78.8
77.9
4
Btuh
7930 7350 6800 6290 5830
5400 5000 4620
4270 3940 3630 3370 .
Cfm
88.8 85.5 84.2 83.3
82.0
81.0
80.0 79.1
78.0
77.0
76.1* 75.3
5
Btuh
7600 7020 6500 6020 5580 5160 4770 4410 4080 3770 3470
3190
Cfm
83.6 82.5
81.3
80.2
79.1
78.1
77.1
76.4
75.3
74.4
73.5
72.8
6
Btuh
7300 6760 6260 5780 5350 4950 4560 4200 3900 3580 3300
3040.
Cfm
80.4 79.5
78.4
77.5
76.3
75.3
74.4
73.5
72.8- 72.0
71.2
70.6
Note: When ear ed the first thits root into tie sctended-plcanm rrrr.ed to ft end S elbows, ooust i extre elbows for tbtt ran. Tbe Eqarvslent Length Vsloes isad sod included in --l---I-*!-* this table ere: Diffaser end Boot -- 100 ft; Etch Elbow * 14 ft; Side Teke-cff Bft. Thpcred Extended-Flenum Starting Coilax.
Section D. Top Take-Off to d-lndt Sound Pip* for Baseboard Diffuser* Oaty
Extended-Plenum Pressure O.lt in. Static at 160 P
Furnace-Plenum Pressure 0.15 in. Static at 170 F
No. of Shew*
Advaf length from Cxfended-Pfeouui fo Diffmer -Feel 5 10 15 20 25 30 35 40 45 50 55 60 .
0
Btuh
8700 8050 7450 6900 6400 5910
5470 5160 4670 4300 4000 3720
Cfm
95.0 93.2 91-7 90.0 88.6 87.3 86.0 84.7 83.5 82.4 81.3 80.2
1
Btuh
8280 7640 7090 6560 6080 5630 5200 4820 4470 4140 3830 3530
Cfm
90.2 .88.8
87.5
86.2
85.0
83.7
82.6
81.7
80.4
79.4
78.4
77.5
2
Btuh
7880 7290 6750 6250 5800 5380 4980 4590 4260 3940 3620 3340
Cfm
86.3
85.0
84.0
82.9
81.7
80.5
79.6
78.7
77.6
76.7
75.8
74.9
3
Btab
7560
7000
6470
5980
5540
5130
4740
4380
4060
3730
3430
3170
Cfm
83.0 82.0 81.0 79.8 79.0 78.0 76.9 76.0 75.1 74.2 73.3 72.5
4
Btuh
7260 6700
6200
6740
5290
4900
4510
4160
3850
3560
3290
3020
Cfm
80.0
79.1
78.1
77.2
76.2, 75.2
74.3
73.5
72.7
71.9
71.0
70.2
5
Btuh
7000 6470 5970 5490 070 4700 4320 3990 3600 3400 3120 2870
Cfm i 77.3 76.3 75.4 74.5 73.6 72.8 71.9 71.2 70.2 69.3 68.7 68.1
6
Btuh
6770
6230
5740
5290
4890
4500
4140
3820
3520
3240
2980
2760
Cfm
74.6 73.8 73.0 72.2 71.3 70.5 . 69.8 69.0 68-3 67.5 66.9 66.1
Note: Where any of tbe first three ran* from the extended-plenum exceeds 10 It and S elbow*, coast 1 extra elbow* for that ran. Tbe Equivalent length Velure uaod and included is --1--this table are: Difiusw and Boot 100 ft; Each Elbow 11 ft; Top Take-aS 80 ft. Tapered Ertendad-Plenora Starting Collar.
taken from basements and crawl spaces, but should not be taken from confined spaces in which the furnace is located.
The following simplified procedure* may be used:
2. Lay out the return-air duct system. Measure tbe length and count the number of 90 deg turns in each return duct.
2. Total tbe heat los of the area served by each return duct. 3. Determine the required duct free area from the length
of duct, the number of 90 deg turns, and the heat loss using Table 8. Also determine the free area of the return grille from Table 8.
Other Perimeter Systems
Each of the foregoing procedures can be used with ap proved furnaces that are capable of delivering their rated cfm air volume against a total pressure of 0.20 in. water
Warm Air Heating Systems
71
Table 6.... Heating Capacities and Cfm of Branch Ducts In Extended-Plenum Perimeter Systems (Concluded)
Section E. Side Take-Off to Sbd) Bowed Pip* for Side-wcD and Boor Diffwxer*
gstended-Plenum Pressure 0.16 in. Static at 160 F
Furnace-Plenum Pressure 0J5 in. Sialic at 170 F
Actual length from fjdeoM-Nonve fo Diffuse*--Feet
5 10 15 20 25 30 35 40- 45 50 55 50
0 Btab Cfm
8600 123.2
7930 120.0
7310 116.8
6740 114.0
6230 111.4
1 Btuh Cfm
8560 117.4
7900 114.5
7290 112.1
6720 109.2
6200 107.0
5740 104.8
2 Btuh Cfm
8510 112.7
7890 110.0
7300 107.6
6740 105.3
6230 103.1
5750 101.0
5310 99.0
3 Btuh Cfm
8540 7900 7300 6780 108.2 105.8 103.6 101.5
6270 99.6
5800 97.8
5360 95.9
4960 94.0
4 Btuh Cfm
8580 104.0
7970 101.9
7370 99.8
6820 97.8
6330 96.0
5850 94.5
5410 92.8
5000 91.1
4620 89.7
5 Btuh Cfm
8720 100.2
8080 98.3
7490 96.7
6940 94.8
6440 93.0
5960 91.4
5490 90.0
5080 88.7
4690 87.2
4320 85.0
6
Btuh
8900
8240
7630
7060
6550
6070
5600
5190
4800
4430
4100
Cfm
97.0
95.1
93.4
91.9
90.2
88.8
87.3
86.2
85.0
83.8
82.6
Note: Where eoy of the firet three mo* from the octended-pleaom exceed* >0 ft end 3 elbow*, count 8 extn elbow* for that run. The Equivalent Length Value* and and included in calculating thij table are; Diffaser aad Boat m 40 ft; Each Elbow -- 14ft; Side Takn-oS 30 ft. Tapered Extended-Pleaam Starting Collar.
5800 109.1
5340 102.8
4960 97.4
4610 92.5
4300 88.3
4020 84.7
3810 81.5
Section F. Top Toke-Off to 6-tncb Rowad Pipe for SMe-wofl and Floor Biffwort
Extended-Plenum Pressure O.lt in. Static at 160 F
Furnace-Plenum Pressure 0.15 in. Static at 170 F
Ho. of Show*
Actual length from fxhaM-FJetM fo Difftnor--feet 5 10 15 20 25 30 35 40 45 50 55 40
0 Btuh Cfm
8430 111.2
7800 1088
7210 106.3
6660 104.4
6170 102.2
5700 100.2
5270 98.4
1'
Btuh Cfm
8450 107.2
7840 105.0
7250 102.8
6700 100.7
6210 98.9
5730 97.0
5300 95.1
4900 93.4
2 . Btuh Cfm
8530 103.2
7900 101.1
7320 99.0
6800 97.2
6280 95.4
5790 93.8
5350 92.1
4960 90.6
4590 89.0
3 Btuh Cfm
8660 99.7
8020 97.8
7430 96.0
6900 94.2
6370 92.4
5900 90.8
6450 89.4
5030 88.0
4650 86.7
4300 85.3
4
Btuh
8810 8180 7580 7010 6500 6000 5550 5150 4750. 4400 4070
Cfm
96.0 94.4 92.8 91.2 89.7 88.0 86.8 85.7 84.3 83 1 82.0
5
Btuh
8390 7770 7200 6650 6160 5700 5280 4890 4500 . 4170 3840
Cfm
91-4
90.0
88.5
87.2
85.8
84.5
83.2
82.4
81.0
80.0
79.0
6
Btuh
7980 7380 6840 6340 5880 5430 6020 4650 4290 3970 3660
Cfm
87.5 86.2 85.0 83.8 82.5 81.4 80.2 79.4 78-3 77.3 76.3
Note: Where any of tbe firn three ran* from the extended-plenum exceed* 30 H aad 3 elbow* count 8 extra elbow* for that rua. The Equivalent Length Value* need aad Included in eaieulating thi* table are: DifftMx aad Boot 40 ft; Each Elbow 14 ft; Top Take-off -> SO (tTapered Riteaded-Renum Starting Collar.
4910 96.7
4560 91.9
4250 87.8
3990 84.2
3780' 81.1
3580 78.3
3400 75.6
eternal to the furnace. This available pressure is usually dis tributed on the basis of three-fourths (0.15 in. water) on tbe
supply side and one-fourth (0.05 in. water) on the return side. Other systems, such as perimeter crawl-space plenum
systems, may be designed by procedures outlined in Manual .4- In addition, procedures for designing 4-in. dtnmptftr duet
systems are contained* in Manual 10 of the National Warm Air Heating and Air Conditioning Association.
Other systems of a proprietary nature but utilising the perimeter concept of diffuser placement are in common use. These systems should be designed and installed in^strict accordance with tbe manufacturer's recommendations. Such systems usually utilize smaller ducts (4 in. or less) and higher pressures (above 0.20 in. water). They also may re quire special streamlined, low resistance fittings and special diffusers. Some systems also employ higher boiwet tempera-